Advertisement for orthosearch.org.uk
Results 1 - 20 of 37
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 536 - 536
1 Sep 2012
Park IS Jung KA Ong A Hwang SH Nam CH Lee DW
Full Access

Background. Adequate rotation of femoral component in total knee arthroplasty(TKR) is mandatory for preventing numerous adverse sequelae. The transepicondylar axis has been a well-accepted reference for femoral component rotation in the measured resection technique. In this technique, measured resection is performed referenced off the tibial cut - perpendicular to the tibial mechanical axis with the knee in 90 ° of flexion. However, to the best of our knowledge, it is not known whether this technique apply well to a knee with tibia vara. This study evaluates the reliability of the transepicondylar axis as a rotational landmark in knees with tibia vara. Methods. We selected 101 osteoarthritis knees in 84 symptomatic patients(mean age: 69.24 ± 5.68) with proximal tibia vara (Group A). Group A was compared with 150 osteoarthritic knees without tibia vara in 122 symptomatic patients (mean age: 69.51 ± 6.01) (Group B). The guide line for selection of all these knees were based on the degree of tibia vara angle (TVA) which was formed by line perpendicular to epiphysis and by anatomical axis of the tibia - all measured in radiographs of the entire lower limb. Magnetic resonance imaging (MRI) axial images with most prominent part of both femoral condyles were used for measurement of transepicondylar axis(TE), anteroposterior axis(AP) and posterior condylar axis(PC). Results. The mean TVA of group A was 8.94° ± 3.11 and group B was 1.24° ± 0.85. The TE line in Group A showed 6.09 ° ± 1.43 of external rotation, relative to PC. This did not show statistical difference compared with 5.95 ° ± 1.58 in Group B (p=0.4717). The AP line in Group A showed 6.06 ° ± 1.93 of external rotation, relative to the line perpendicular to PC. This was statistically significant when compared to 5.44 ° ± 2.13 in Group B (p=0.020). Conclusion. There is no difference between knees without tibia vara compared those with tibia vara with regards to transepicondylar axis. In addition, both groups have almost identical external rotation of approximately 6 °. The AP axis was only approximately 0.5 ° difference between the two groups. The distal femoral geometry was not affected by tibia vara deformity, that is, there were no hypoplastic or hyperplastic deformities of medial femoral condyle in osteoarthritic knees with tibia vara. The use of transepicondylar axes in determining femoral rotation may produce flexion asymmetry in knees with proximal tibia vara. So, It should be pointed out that more attention should be paid on femoral component rotation and flexion gap balancing in knees with proximal tibial vara


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 15 - 15
1 Apr 2013
Kim J Oh CW Oh JK Lee HJ Kyung HS
Full Access

Background

To establish relative fixation strengths of a single lateral locking plate, a double locking plate, and a tibial nail in treatment of proximal tibial extra-articular fractures.

Methods

Three groups of composite tibial synthetic bones consisting of 5 specimens per group were included; lateral plating (LP) using a LCP-PLT (locking compression plate-proximal lateral tibia), double plating (DP) using a LCP-PLT and a LCP-MPT (locking compression plate-medial proximal tibia), and intramedullary nailing (IN) using an ETN (expert tibial nail). To simulate a comminuted fracture model, a gap osteotomy measuring 1 cm was cut 8 cm below the joint. For each tibia, a minimal preload of 100N was applied before loading to failure. A vertical load was applied at 25mm/min until tibia failure.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 6 - 6
1 May 2018
Abdelhaq A Walker E Sanghrajka A
Full Access

Background. Disruption of the normal relationship between the proximal tibia and fibula is seen in a number of different conditions such as skeletal dysplasias and post-infective deformity, as well as the consequence of lengthening procedures. Radiographic indices for the tibio-fibular relationship at the ankle have been described, but no similar measures have been reported for the proximal articulation. Aim. The purpose of this study was to investigate the normal radiographic relationship between the proximal tibia and fibula in children to determine the normal range and variation. Methods. Our radiology database was used to identify a sample of 500 normal anteroposterior radiographs of paediatric knees. All radiographs were reviewed by a single observer. The distance from the corner of the lateral tibial plateau to both the proximal tibial (PT) and fibular physes (PF) were measured, and a ratio of the two calculated (PF/PT). The process was repeated with a sample of 100 radiographs by the same observer, and a second independent observer in order to calculate intra-and inter-observer reliability. Results. The age range of patients in this study was 4–16 years, with mean age 12.7. The mean PF/PT ratio was 1.7 (standard deviation 0.2, range 1.3–2.0). Intra-observer reliability was 100% and inter-observer reliability was 97.8%. Conclusion. The results of this study demonstrate that in the normal paediatric knee, there is a consistent relationship between the position of the proximal tibial and fibular physes, with a small range of variation. The PF/PT ratio is a simple and reliable way of assessing the relationship between the proximal tibia and fibula in children, using a standard anteroposterior radiograph. This ratio could be very useful in the diagnosis and planning of surgical management of a number of different causes of tibial and fibular deformities in children


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 40 - 40
1 Apr 2013
Paetzold R Spiegl U Wurster M Augat P Gutsfeld P Gonschorek O Buehren V
Full Access

Alpine ski sports changed rapidly in the last decade. Complex fractures of the proximal tibia, typically seen in high energy trauma, has been seen more frequently and more often related to alpine skiing. The aim of our study was to identify reasons for proximal tibia fracture in alpine skiing and observe the outcome. All patients with proximal tibia fractures related to alpine skiing, which were treated in our two trauma centers were included. The patients received a questionnaire at the emergency department, dealing with accident details and the skiing habits. The fractures were classified according to the AO fracture classification scheme. The follow up was performed at least one year after trauma with the Lysholm, the Tegner activity, as well as the WOMAC VAS Score. Between 2007 and 2010 a total of 188 patients with proximal tibia fractures caused by alpine skiing were treated. 43 patients had a type A, 96 patients a type B and 49 a type C injury. The incidence was increasing over the period continuously. The main trauma mechanism was an accident without a third party involvement with an increased rotational and axial compression impact. All outcome scores were related to fracture severity with significant worse results for the type C fractures. In conclusion, proximal tibia fractures are an increasing and serious injury during alpine skiing. Further technical progress in skiing material should focus on these knee injuries in future


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 18 - 18
1 May 2018
Williamson M Iliopoulos E Jain A Ebied W Trompeter A
Full Access

Background. There exists no consensus opinion as to the most suitable post-operative rehabilitation and weight bearing status for proximal tibia articular fractures treated with internal fixation using plates and screws. Objectives. The aim of this study is to investigate whether the post-operative weight bearing status is associated with loss of reduction and articular collapse. Study Design and Methods. Data was retrospectively analysed from our prospective database in a major trauma centre. Group I were non-weight bearing for the first six weeks post-operation and Group II were instructed to weight bear fully immediately post-operation. Radiographs were taken day one post-operation, at six weeks and at three months and analysed for fracture displacement and joint depression or loss of fixation. Results. 90 patients were included in the study. The follow up radiographs demonstrated no failure of fixation in either study group. One patient from the weight bearing group had >1mm joint depression (4mm) identified at the first follow up, which did not worsen by the second. Conclusions. This study shows immediate post-operative full weight bearing does not affect the fixation or cause articular collapse up to three months after surgery. We propose that patients should be encouraged to weight bear immediately post-operation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 449 - 449
1 Sep 2012
Teixidor Serra J Tomas Hernandez J Barrera S Pacha Vicente D Batalla Gurrea L Collado Gastalver D Molero Garcia V Arias Baile A Selga J Nardi Vilardaga J Caceres E
Full Access

Introduction and objectives. Intramedullary nailing is indicated to stabilization of tibia shaft fractures. Intramedullary nailing through an infra-patellar incision is commonly the technique of choice. While intramedullary nailing of simple diaphyseal fracture patterns is relatively easy, proximal tibia fractures, extremely comminuted/segmental tibia fractures, politrauma with multiple fractures in both extremities and reconstruction of bone loss segment with stiffness of the knee joint can be very challenging to treat. A novel technique for intramedullary tibia nailing through the patella-femoral joint is described. This technique allow extension tibia during intervention time and it supplies easier reduction of the pattern of fracture above. The purpose of our investigation was to evaluate the use of this new technique in described above pattern fracture and patient situation; because we have thought that new technique can perform better outcomes in this situations. Materials and Methods. An observational study of tibia fractures or bone defect was performed for consecutive patients who presented: proximal tibia fractures, extremely comminuted/segmental tibia fractures, politrauma with multiple fractures in both extremities and reconstruction of bone loss segment in the Trauma unit of our institution from September 2009 to August 2010. A total of 32 were included in our study, which performed surgery intervention with Trigen tibia nail (Smith & Nephew, Memphis) with suprapatelar device. Demographic data, mechanism of injury, fracture classification, ROM (2 and 6 weeks, and 3 months), consolidation rate, reduction fracture quality and knee pain at 3 months were recorded. Results. Male was the gender most frequent (64%), the average age was 39,5 years and the main mechanism of injury was motor vehicle injury (30,6%). There were 7 proximal fractures, 1 bifocal fracture, 6 politrauma and 2 reconstruction bone loss segment, the others were comminuted and segmental tibia fracture. In all the patients, the fracture was consolidated between 8 to 14 weeks with average of 10,6 weeks. The quality of reduction was correct in all patients in different axis. The average of ROM at 2 weeks was (−2°/95°) at 3 months was (−0,4°/133°). The knee pain (VAS) average was 0,6 only in 2 patients were (4). Poller screw was used in 7 patients. Conclusion. The suprapatelar nailing is optimal technique to resolve complex fracture of the tibia (proximal, segmental conminution, politrauma) that perform correct consolidation rate without misalignment in the patients. Concerns about knee pain (VAS) from the technique not appear in our data. Prospective and clinical trials are needed to validate this approach


Bone & Joint Open
Vol. 4, Issue 2 | Pages 104 - 109
20 Feb 2023
Aslam AM Kennedy J Seghol H Khisty N Nicols TA Adie S

Aims

Patient decision aids have previously demonstrated an improvement in the quality of the informed consent process. This study assessed the effectiveness of detailed written patient information, compared to standard verbal consent, in improving postoperative recall in adult orthopaedic trauma patients.

Methods

This randomized controlled feasibility trial was conducted at two teaching hospitals within the South Eastern Sydney Local Health District. Adult patients (age ≥ 18 years) pending orthopaedic trauma surgery between March 2021 and September 2021 were recruited and randomized to detailed or standard methods of informed consent using a random sequence concealed in sealed, opaque envelopes. The detailed group received procedure-specific written information in addition to the standard verbal consent. The primary outcome was total recall, using a seven-point interview-administered recall questionnaire at 72 hours postoperatively. Points were awarded if the participant correctly recalled details of potential complications (maximum three points), implants used (maximum three points), and postoperative instructions (maximum one point). Secondary outcomes included the anxiety subscale of the Hospital and Anxiety Depression Scale (HADS-A) and visual analogue scale (VAS) for pain collected at 24 hours preoperatively and 72 hours postoperatively. Additionally, the Patient Satisfaction Questionnaire Short Form (PSQ-18) measured satisfaction at 72 hours postoperatively.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 516 - 522
10 Jul 2023
Mereddy P Nallamilli SR Gowda VP Kasha S Godey SK Nallamilli RR GPRK R Meda VGR

Aims

Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections.

Methods

Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30).


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 257 - 257
1 Sep 2012
Maric M Bergovec M Viskovic A Kolundzic R Smerdelj M Orlic D
Full Access

AIM. To present our experience in patients treated under primary diagnosis giant cell tumor of bone at Department Orthopaedic Surgery Zagreb University School of Medicine in a 15-year period from 1995 to 2009. METHODS. We performed a retrospective study of all patients treated in our Department because of giant cell tumor of bone (GCT) from 1995 to 2009. The mean age of our patients was 29,9 years (range: 14 to 70 years). Sex distribution showed prevalence in female (F:M=23:12=66%:34%). All together, 39 patients were operated under primary diagnosis of GCT. Four patients were lost in follow-up. In total, 35 patients were included in study. Diagnosis of GCT was made according to clinical, imaging and histological findings, and distributed by Campanacci's classification. RESULTS. Not including diagnostic biopsy, 84 operations were performed on 35 patients. Fourteen patients (40%) had GCT grade 1, fourteen (40%) had GCT grade 2, and seven (20%) had GCT grade 3. From the first symptoms to diagnosis there was an average duration of 7 months (range: 0 to 24 months), where the main symptoms were pain and swelling of affected bone and/or joint. GCT was localized in distal femur (n=12, 34%), proximal tibia (n=10, 29%), distal tibia (n=4, 11%), distal radius (n=3, 9%), and other locations (n=6, 17%). Patients with less aggressive GCT (grades 1 and 2) were treated with marginal excision: excochleation and reconstruction with bone transplant (n=12, 34%). In patients with locally more aggressive tumor (grades 2 and 3), “en bloc” resection and reconstruction with tumor endoprosthesis or bone transplant was performed (n=22, 63%). Due to localization of tumor, one patient was treated with radiation (3%). Complications were recorded in 12 patients (34%), and are shown as total number and percentage of all complications. Complications were the most common in knee region, proximal tibia (n=4, 33%) and distal femur (n=3, 25%). Also, the complications occured more frequently after “en bloc” resection (n=7, 58%). GCT classified as gradus 2 had most complications (n=5, 42%) till GCT classified as gradus 3 had least (n=3, 25% of complications, 9% of all). We recorded and treated local recurrence of tumor (n=6, 50%), infection (n=2, 17%), and mehanical complications of endoprosthesis (n=2, 17%). Due to local recurrences, in 2 patients underlying osteosarcoma was revealed, and they were treated with amputation. CONCLUSION. Each patient with GCT should be treated individually. Regardless non-malignant attribute, local behaviour of tumor determines treatment approach according to treatment principles of malignant tumor of bone. Number of complications in our patients is relatively high, recorded in one third of our patients, which matches the literature in announced studies


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 9 - 9
1 Jun 2017
Wright J Calder P
Full Access

Background. Severe infantile Blount's disease can result in a multiplanar deformity of the proximal tibia with both intra-articular and metaphyseal components. Correction can represent a significant surgical challenge. We describe our results using the Taylor spatial frame for acute tibial hemiplateau elevation combined with gradual metaphyseal correction in patients with severe infantile blounts with an associated physeal bony bar. Methods. Eight patients (10 knees) underwent tibial hemiplateau elevation and metaphyseal correction with use of the Taylor Spatial Frame between 2012–2016. We undertook a retrospective case note and radiographic review of all patients to assess clinical and radiographic outcomes. Mean age at the time of surgery of was 11.7 years and mean length of follow up was 16.8 months. Results. At time of latest follow up all patients reported no hip, knee or ankle pain. All knees were clinically stable without lateral thrust during gait. Improvement in radiographic parameters was seen in all patients. The mean tibiofemoral angle improved from −28.3 to 5.9 degrees post operatively. The angle between femoral condyles and the tibial shaft improved from a mean of 56.3 degrees to 90.3 degrees. The joint depression angle was also seen to improve from mean 47.4 degrees to 9.8 degrees. No significant complications were seen. Conclusion. This technique has been shown to be an effective method of correction of the complex deformity encountered in severe infantile Blount's disease. Use of the Taylor spatial frame may provide certain advantages in comparison to previously described approaches. Level of Evidence: Level IV (Case Series)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_12 | Pages 10 - 10
1 Jun 2016
Scott C Eaton M Nutton R Wade F Evans S Pankaj P
Full Access

25–40% of unicompartmental knee replacement (UKR) revisions are performed for unexplained pain possibly secondary to elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on cancellous bone strain in a finite element model (FEM) of a cemented fixed bearing medial UKR, validated using previously published acoustic emission data (AE). FEMs of composite tibiae implanted with an all-polyethylene tibial component (AP) and a metal backed one (MB) were created. Polyethylene of thickness 6–10mm in 2mm increments was loaded to a medial load of 2500N. The volume of cancellous bone exposed to <−3000 (pathological overloading) and <−7000 (failure limit) minimum principal (compressive) microstrain (µ∊) and >3000 and >7000 maximum principal (tensile) microstrain was measured. Linear regression analysis showed good correlation between measured AE hits and volume of cancellous bone elements with compressive strain <−3000µ∊: correlation coefficients (R= 0.947, R2 = 0.847), standard error of the estimate (12.6 AE hits) and percentage error (12.5%) (p<0.001). AP implants displayed greater cancellous bone strains than MB implants for all strain variables at all loads. Patterns of strain differed between implants: MB concentrations at the lateral edge; AP concentrations at the keel, peg and at the region of load application. AP implants had 2.2 (10mm) to 3.2 (6mm) times the volume of cancellous bone compressively strained <−7000µ∊ than the MB implants. Altering MB polyethylene insert thickness had no effect. We advocate using caution with all-polyethylene UKR implants especially in large or active patients where loads are higher


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_4 | Pages 11 - 11
1 May 2015
Clement N Keenan G Marsh D Nayagam D Atkins R Simpson A
Full Access

We conducted a multicentre two arm double blind randomised controlled trial to assess efficacy of pulsed ultrasound for accelerating the rate of bone healing. Sixty-two skeletally mature adults undergoing limb lengthening, of between 2.5cm to 10cm by distraction osteogenesis, at the proximal tibia using an Ilizarov frame were randomised to either an active or a placebo (control) ultrasound device. Primary outcome measure was time ready for removal of frame after adjusting for distraction length (days/cm) for both intension to treat (ITT) and per protocol (PP) patients. The time at which the frame was removed was determined by the maturation of the regenerate bone. Secondary outcomes were return to weight bearing and covariates affecting time to frame removal. The baseline characteristics of the two groups were well balanced, and 90% of patients were managed and followed up as PP. There was no difference in the time to frame removal between the two groups for the ITT (5.0days/cm, p=0.23) or the PP (10.1days/cm, p=0.054). There was no difference in return to weight bearing between the two groups, after adjusting for distraction length, for the ITT or PP patients (p>0.5). Smoking was the only covariate identified to increase the frame removal time (hazard ratio 0.46, 95% confidence interval 0.22 to 0.96; p=0.04). This trial demonstrated no difference in bone healing between those who underwent pulsed ultrasound and those who did not. Smoking was observed to have a significant inhibitory effect on bone healing


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 11 - 11
1 May 2015
Simpson A Clement N Keenan G Nayagam S Atkins R Marsh D
Full Access

Objective:. To assess efficacy of pulsed ultrasound for accelerating regenerate consolidation. Design:. A multicentre two arm patient and assessor double blind RCT. Setting:. Four UK centres (Edinburgh, Belfast, Liverpool, Bristol). Participants:. 62 skeletally mature adults undergoing distraction osteogenesis of 2.5–10cm at the proximal tibia. Patients with metabolic bone disorders were excluded. Interventions:. A metaphysial corticotomy was created and an Ilizarov frame applied. After 7 days, distraction was performed (0.75mm/day). After 1cm of distraction, an ‘ultrasound’ device was used for 20 minutes/day. Patients were randomised to either an active or a placebo (control) ultrasound device. Main outcome measures:. Primary outcome measure: time ready for removal of frame for both intension to treat (ITT) and per protocol (PP). Secondary outcomes: covariates affecting time to frame removal, return to weight bearing (>50% body weight), and compliance with device usage. Results:. 90% patients were managed as PP. There was no difference in time to frame removal for ITT (difference . in favour of control. group- 5.0days/cm, 95% CI −8.2 to18.21; p=0.23) or PP (difference . in favour of control. group-10.1days/cm, 95% CI −3.2 to 23.4; p=0.054). Smoking was the only covariate to increase frame removal time (hazard ratio 0.46, 95% CI 0.22 to 0.96; p=0.04). There was no difference in weight bearing between the two groups, after adjusting for distraction length, for the ITT cohort (p>0.5). The compliance was 78.8% & 81.6% in the PP group and 70.0 & 72.3% in the ITT group for active & control devices respectively. Conclusions:. Contrary to the existing literature, including NICE guidelines, this trial found no difference in bone healing between those who underwent low intensity pulsed ultrasound and those who did not. The trial was sufficiently powerful to demonstrate that smoking had a significantly deleterious effect on bone healing; approximately doubling the healing time


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 170 - 170
1 Sep 2012
Scott C Bhattacharya R Macdonald D Wade F Nutton R
Full Access

Unicompartmental knee replacements (UKRs) have inconsistent and variable survivorships reported in the literature. It has been suggested that many are revised for ongoing pain with no other mode of failure identified. Using a medial UKR with an all-polyethylene non-congruent tibial component from 2004–7, we noted a revision rate of 9/98 cases (9.2%) at a mean of 39 months. Subchondral sclerosis was noted under the tibial component in 3/9 revisions with well fixed implants, and the aim of this study was to investigate this as a mode of failure. 89 UKRs in 77 patients were investigated radiographically (at mean 50 months) and with SF-12 and Oxford Knee scores at mean follow up 55 months. Subjectively 23/89 cases (25%) had sclerosis under the tibial component. We describe a method of quantifying this sclerosis as a greyscale ratio (GSR), which was significantly correlated with presence/absence of sclerosis (p<0.001). Significant predictors of elevated GSR (increasing sclerosis) were female sex (p<0.001) and elevated BMI (P=0.010) on both univariate and multivariate analysis. In turn, elevated GSR was significantly associated with poorer improvement in OKS (p<0.05) at the time of final follow up. We hypothesise that this sclerosis results from repetitive microfracture and adaptive remodelling in the proximal tibia due to increased strain. Finite element analysis is required to investigate this further, but we suggest caution should be employed when considering all polyethylene UKR implants in older women and in those with BMI >35


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 261 - 261
1 Sep 2012
Espandar R Mortazavi SMJ Kaseb MH Haghpanah B Yazdanian S
Full Access

Background. Medial opening-wedge high tibial osteotomy is one of the common surgical procedures in treatment of knee deformities. Many methods have been proposed to fill the medial side osseous gap. The results of using allograft as void filler compared to iliac crest autograft has not been subject to a randomized clinical trial. The purpose of this study was to examine the results of medial opening-wedge high tibial osteotomy using iliac crest allograft as compared to iliac crest autograft. Materials & Methods. Forty-six patients with genovarum deformity were enrolled based on specific inclusion and exclusion criteria and were randomly assigned into two groups. Medial opening-wedge high tibial osteotomy was done using iliac crest allograft (23 patients) or autograft (23 patients) and the osteotomy site was internally fixed using proximal tibial T-plate. All patients were followed-up to 12 months after surgery. Anatomical indices of proximal tibia, complications of treatment, and functional outcome (using WOMAC osteoarthritis index) were assessed for both groups. Results. The amount of correction (degrees), recurrence of the deformity and loss of correction and time to clinical or radiologic union were similar in both groups with no statistically significant difference. Duration of operation was significantly less in allograft group (66.6±3.6 versus 52.9±5.3 minutes, p<0.001). Incidence of surgical site infection did not significantly differ in two groups. No nonunion or delayed union was encountered in either group. Some patients reported more intense postoperative pain in iliac graft harvest site than tibial osteotomy site. Patients in both groups had statistically significant improvement in WOMAC index postoperatively (with no statistically significant difference between groups). Conclusions. According to the results of this study, iliac crest allograft may be safely used in medial opening-wedge high tibial osteotomy with comparable efficacy to iliac crest autograft in patients who do not accept the morbidity of autograft harvest


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 153 - 153
1 Sep 2012
De Biase P Capanna R Campanacci D Beltrami G Scoccianti G Piccioli A
Full Access

The reconstruction of lower limb defects after oncological reconstructions is still a problem in limb salvage surgery. Large bony defects need to be treated with sound and durable reconstructions. During recent decades, the life expectancy of patients affected with cancer has improved considerably because of advances in chemotherapy, immunotherapy, hormonal treatment and radiotherapy. This improvement requires greater reliability in the reconstructive procedure in order to avoid mechanical failure during prolonged survival of the patient. The author experience with modular megaprosthesis by Link (megasystem C) allowed us to present a rapid, effective and functional solution. From June 2001 to December 2007 225 patients have been operated with a megaprosthesis C for tumoral resection. The new megaprosthesis C by Link represents a wide-ranging system that can afford a large variety of reconstructions in the inferior limb, from very short replacement of 5 cm in proximal femur, to a total femur and proximal tibia replacement. Modularity is represented by 1 cm increase in length. The different options of cemented and not cemented stem may be used with intraoperative decision. In cemented stem a rough collar seals the osteotomy and prevents polyethylene debris from entering the femoral canal by inducing a scar tissue around the stem entrance (so-called purse-string effect). Moreover in patients with solitary lesions and very good prognosis an allograft-prosthesis composite can be performed with improved clinical results on walking and function. Of the 225 patients that underwent tumoral resection and reconstruction with a modular megaprosthesis approximately 43% (97 cases) were operated for metastatic disease. Among these cases 55 cases were proximal femoral recontructions, 39 cases were distal femoral reconstructions and 3 cases were proximal tibial reconstructions. All cases were performed with cemented stems. We experienced a 7% of postoperative infections, 2% of dislocations of proximal femoral prosthesis and 3% of mechanical failures. While infections and dislocation rates were in the average for this surgery, mechanical failures were relatively high. We should consider that in patients with relatively long resections and muscle deficiency the mechanical stress exerted on the prosthesis can explain this kind of mechanical failure. However the new design of morse tapers have annulled these problems


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 497 - 503
1 May 2002
Hedström M åström K Sjöberg H Dalén N Sjöberg K Brosjö E

A total of 63 women who had an operation for a fracture of the hip was randomly allocated to one year of treatment either with anabolic steroids, vitamin D and calcium (anabolic group) or with calcium only (control group). The thigh muscle volume was measured by quantitative CT. The bone mineral density of the hip, femur and tibia was assessed by quantitative CT and dual-energy x-ray absorptiometry and of the heel by quantitative ultrasound. Quantitative CT showed that the anabolic group did not lose muscle volume during the first 12 months whereas the control group did (p< 0.01). There was less bone loss in the proximal tibia in the anabolic group than in the control group. The speed of gait and the Harris hip score were significantly better in the anabolic group after six and 12 months. Anabolic steroids, even in this moderate dose, given in combination with vitamin D and calcium had a beneficial effect on muscle volume, bone mineral density and clinical function in this group of elderly women


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 370 - 370
1 Sep 2012
Schlegel U Siewe J Püschel K Gebert De Uhlenbrock A Eysel P Morlock M
Full Access

Despite proven advantages, pulsatile lavage seems to be used infrequently during preparation in cemented total knee arthroplasty. This remains irritating, as the technique has been suggested to improve radiological survival in cemented TKA, where aseptic loosening of the tibial component represents the main reason for revision. Furthermore, there may be a potential improvement of fixation strength for the tibial tray achieved by increased cement penetration. In this study, the influence of pulsed lavage on mechanical stability of the tibial component and bone cement penetration was analyzed in a cadaveric setting. Six pairs of cadaveric, proximal tibia specimen underwent computed tomography (CT) for assessment of bone mineral density (BMD) and exclusion of osseous lesions. Following surgical preparation, in one side of a pair, the tibial surface was irrigated using 1800ml normal saline and pulsatile lavage, while in the other side syringe lavage using the identical amount of fluid was applied. After careful drying, bone cement was hand-pressurized on the bone surface, tibial components were inserted and impacted in an identical way. After curing of cement, specimen underwent a postimplantation CT analysis). Cement distrubution was then assessed using a three-dimenionsional visualization software. Trabecular bone, cement and implant were segmented based on an automatic thresholding algorithm, which had been validated in a previous study. This allowed to determine median cement penetration for the entire cemented area. Furthermore, fixation strength of the tibial trays was determined by a vertical pull-out test using a servohydraulic material testing machine. Testing was performed under displacement control at a rate of 0,5mm/sec until implant failure. Data was described by median and range. Results were compared by a Wilcoxon matched pairs signed rank test with a type 1 error probability of 5 %. Median pull-out forces in the pulsed lavage group were 1275N (range 864–1391) and 568N (range 243–683) in the syringe lavage group (p=0.031). Cement penetration was likewise increased (p=0.031) in the pulsed lavage group (1.32mm; range 0.86–1.94), when compared to the syringe irrigated group (0.79mm; range 0.51–1.66). Failure occurred in the pulsatile lavage group at the implant-cement interface and in the syringe lavage group at the bone-cement interface, which indicates the weakness of the latter. Altogether, improved mechanical stability of the tibial implant and likewise increased bone cement interdigitation could be demonstrated in the current study, when pulsed lavage is implemented. Enhanced fixation strength was suggested being a key to improved survival of the implant. If this is the case, pulsatile lavage should be considered being a mandatory preparation step when cementing tibial components in TKA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 158 - 158
1 Sep 2012
Funovics P Rois S Kotz R Dominkus M Windhager R
Full Access

Background. Modular endoprostheses today represent a standard treatment option in the management of musculoskeletal tumors of the lower extremities. Long-term results of these reconstructions, however, are often limited by the course of the underlying disease. We therefore report our experiences in cancer patients with megaprostheses of the lower limb after a minimum of 15 years. Materials and Methods. 62 patients, 34 men and 28 women, with a mean age of 26 years (median, 20; range, 6–83) were included in this investigation with a mean follow-up of 230 months (median, 228; range, 180–342). Endoprosthetic reconstructions of the proximal femur (11), the distal femur (28), the total femur (2) or the proximal tibia (21) were indicated for osteosarcoma (43), chondrosarcoma (5), malignant fibrous histiocytoma (3) or other tumors (11). All patients have received either a KMFTR (22) or a HMRS (40) modular prosthesis; 23 patients had a muscle flap, 14 had a fibular transposition osteotomy and 4 have received an artificial LARS ligament for soft-tissue reconstruction. Results. 7 patients (11.3%) died throughout the follow-up period, but none succumbed to primary disease. One patient (1.6%) developed a local recurrence after 31 months that was resected. Overall, 56 patients (90.3%) underwent revision of their prosthesis; 50 (80.7%) had multiple revisions up to a maximum of 12 operations (mean, 3 per patient). The median overall prosthetic survival to first revision was 40 months; the corresponding 5-, 10- and 15-year survival rates were 35.5%, 14.5% and 12.9%, respectively. 3 patients (5.4%) had an infection, 8 (14.3%) had a soft-tissue related failure, 30 (53.6%) had a mechanical or structural failure and 15 (26.8%) had an aseptic loosening. The 15-year survival rates of these respective endpoints were 87.1% for infection, 79.0% for soft-tissue related failure, 32.3% for mechanical or structural failure and 56.5% for aseptic loosening. 59 patients (95.2%) have retained their prosthesis; 2 patients (3.2%) underwent secondary amputation due to an irresolvable complication, another one (1.6%) for a second malignancy. Conclusion. Modular prosthetic reconstructions of the lower extremities have a high revision rate in the long-term, primarily due to mechanical failures. Given that patients survive their malignant disease the rate of secondary implant removal, however, tends to be low, providing satisfactory function and body integrity. Further advances in implant design, soft tissue management and infection prophylaxis are required to reduce revision rates