Advertisement for orthosearch.org.uk
Results 1 - 20 of 623
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 249 - 259
1 Feb 2016
Sabharwal S Carter AW Rashid A Darzi A Reilly P Gupte CM

Aims. The aims of this study were to estimate the cost of surgical treatment of fractures of the proximal humerus using a micro-costing methodology, contrast this cost with the national reimbursement tariff and establish the major determinants of cost. Methods. A detailed inpatient treatment pathway was constructed using semi-structured interviews with 32 members of hospital staff. Its content validity was established through a Delphi panel evaluation. Costs were calculated using time-driven activity-based costing (TDABC) and sensitivity analysis was performed to evaluate the determinants of cost. Results. The mean cost of the different surgical treatments was estimated to be £3282. Although this represented a profit of £1138 against the national tariff, hemiarthroplasty as a treatment choice resulted in a net loss of £952. Choice of implant and theatre staffing were the largest cost drivers. Operating theatre delays of more than one hour resulted in a loss of income. Discussion. Our findings indicate that the national tariff does not accurately represent the cost of treatment for this condition. Effective use of the operating theatre and implant discounting are likely to be more effective cost containment approaches than control of bed-day costs. Take home message: This cost analysis of fractures of the proximal humerus reinforces the limitations of the national tariff within the English National Health Service, and underlines the importance of effective use of the operating theatre, as well as appropriate implant procurement where controlling costs of treatment is concerned. Cite this article: Bone Joint J 2016;98-B:249–59


Bone & Joint Research
Vol. 6, Issue 10 | Pages 584 - 589
1 Oct 2017
den Teuling J Pauwels B Janssen L Wyers C Janzing HMJ van den Bergh J Morrenhof JW

Objectives. The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma. Methods. A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on plain anteroposterior radiographs of the proximal humerus. Results. No significant differences were found between simple and complex fractures of the proximal humerus in the BMD of the hip, FN or LS (all p > 0.3) or in the CI (p = 0.14). Only the body mass index was significantly higher in patients with a complex fracture compared with those with a simple fracture (26.9 vs 25.2; p = 0.05). Conclusion. There was no difference in BMD of the hip, FN, LS or CI of the proximal humerus in simple compared with complex fractures of the proximal humerus after a low-energy trauma. Factors other than the BMD and CI, for example body mass index, may play a more important role in the complexity of this fracture. Cite this article: J.W.A.M. den Teuling, B.S. Pauwels, L. Janssen, C.E. Wyers, H. M. J. Janzing, J.P.W. van den Bergh, J. W. Morrenhof. The Influence of bone mineral density and cortical index on the complexity of fractures of the proximal humerus. Bone Joint Res 2017;6:584–589. DOI: 10.1302/2046-3758.610.BJR-2017-0080


Abstract. Reverse shoulder arthroplasty (RSA) is being increasingly used for complex, displaced fractures of the proximal humerus. The main goal of the current study was to evaluate the functional and radiographic results after primary RSA of three or four-part fractures of the proximal humerus in elderly patients. Between 2012 and 2020, 70 consecutive patients with a recent three- or four-part fracture of the proximal humerus were treated with an RSA. There were 41 women and 29 men, with a mean age of 76 years. The dominant arm was involved in 42 patients (60%). All surgeries were carried out within 21 days. Displaced three-part fracture sustained in 16 patients, 24 had fracture dislocation and 30 sustained a four-part fracture of the proximal humerus. Patients were followed up for a mean of 26 months. The mean postoperative OSS at the end of the follow-up period was 32.4. The mean DASH score was 44.3. Tuberosity non-union occurred in 18 patients (12.6%), malunion in 7 patients (4.9%), heterotopic ossification in 4 patients (2.8%) and scapular notching in one patient. Anatomical reconstruction was achieved in 25 patients (17.5%), the influence of greater tuberosity healing on shoulder function could not be demonstrated. Heterotopic ossification seems to affect OSS and QDASH, we found statistically significant relation between HO and clinical outcomes. Patients with heterotopic ossification had significantly lower postoperative scores on DASH and OSS (P = .0527). Despite expecting good functional outcome with low complication rate after RSA, the functional outcome was irrespective of healing of the tuberosities


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 91 - 91
1 Mar 2008
Guy P Stone J McCormack R O’Brien P
Full Access

We reviewed the results of sixteen patients with three and four part proximal humerus fractures treated with the Locking Proximal Humerus Plate (LPHP) in two trauma centres. All fractures were radiographically healed by six weeks. We found a high rate of fixation failure 4/16 cases within two weeks of surgery and range of motion results similar to previously reported techniques. This device has not demonstrated its clear superiority when used in trauma centres which commonly treat proximal humerus fractures. A randomised control trial comparing it to classical techniques and using outcome-based measures would seem appropriate. Proximal humerus fractures with poor functional outcomes are expected to increase in frequency owing to an active ageing population. New angle stable devices have been developed to address the frequently associated osteoporosis and loss of fixation. This study reviews the early experience of fixation with an angle stable device, the LPHP (Synthes Canada). Three and four part fractures treated with the LPHP were identified from the database of two trauma centres. Demographics, patient activity level, mechanism of injury, fracture type were collected. Early complications, maintenance of reduction, and ROM were reviewed. Sixteen fractures treated with the LPHP. Male to female ratio was 1.3:1. Mean age was 51.5 (29–77) Activity: 12/16 sedentary, 4/16 manual labourers. Mechanism: four Low and twelve High-energy injuries. Fracture classification: Five three part, and Eleven four part fractures. Early complications: one wound haematoma,one re-operation for intra-articular hardware, and four of sixteen pts pulled off the greater tuberosity fixation within two weeks of surgery. Union was achieved in all sixteen by six weeks. The mean forward elevation was 60° at six weeks and 80° at three months. This review of the early experience with the LPHP shows a significant rate of fixation failure (4/16 cases) and functional ROM results similar to other previously described techniques. Although a “learning curve effect” is possible, this device has not demonstrated clear superiority with surgeons who commonly treat proximal humerus fractures. A randomised control trial comparing it to classical techniques would seem appropriate


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 318 - 323
1 Mar 2018
Raiss P Alami G Bruckner T Magosch P Habermeyer P Boileau P Walch G

Aims. The aim of this study was to analyze the results of reverse shoulder arthroplasty (RSA) in patients with type 1 sequelae of a fracture of the proximal humerus in association with rotator cuff deficiency or severe stiffness of the shoulder. Patients and Methods. A total of 38 patients were included: 28 women and ten men. Their mean age at the time of arthroplasty was 73 years (54 to 91). Before the RSA, 18 patients had been treated with open reduction and internal fixation following a fracture. A total of 22 patients had a rotator cuff tear and 11 had severe stiffness of the shoulder with < 0° of external rotation. The mean follow-up was 4.3 years (1.5 to 10). The Constant score and the range of movement of the shoulder were recorded preoperatively and at final follow-up. Preoperatively, radiographs in two planes were performed, as well as CT or arthro-CT scans; radiographs were also performed at final follow-up. Results. The mean Constant score improved from 25 points (5 to 47) preoperatively to 57 points (15 to 81) postoperatively. The mean forward elevation of the shoulder increased from 73° (10° to 130°) preoperatively to 117° (15° to 170°) postoperatively. Previous surgery did not influence the outcome. Patients with rotator cuff tears had lower Constant scores than patients without (p = 0.037). Those with preoperative stiffness of the shoulder had lower postoperative external rotation compared with patients without stiffness (p = 0.046). There was no radiographic evidence of loosening. Three complications occurred, leading to revision surgery in two patients. In all, 17 patients rated their result as very good (45%), another 17 as good (45%), two as satisfactory (5%), and two as unsatisfactory (5%). Discussion. RSA is an effective form of treatment for patients with type 1 sequelae of a fracture of the proximal humerus associated with rotator cuff deficiency or stiffness of the shoulder, with high rates of satisfaction. Rotator cuff tears and stiffness of the shoulder had an adverse effect on the clinical outcome. Cite this article: Bone Joint J 2018;100-B:318–23


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 387 - 392
1 Mar 2011
Robinson CM Murray IR

Fractures and nonunions of the proximal humerus are increasingly treated by open reduction and internal fixation. The extended deltopectoral approach remains the most widely used for this purpose. However, it provides only limited exposure of the lateral and posterior aspects of the proximal humerus. We have previously described the alternative extended deltoid-splitting approach. In this paper we outline variations and extensions of this technique that we have developed in the management of further patients with these fractures


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1244 - 1249
1 Sep 2017
Cladière-Nassif V Bourdet C Audard V Babinet A Anract P Biau D

Aims. Resection of the proximal humerus for the primary malignant bone tumour sometimes requires en bloc resection of the deltoid. However, there is no information in the literature which helps a surgeon decide whether to preserve the deltoid or not. The aim of this study was to determine whether retaining the deltoid at the time of resection would increase the rate of local recurrence. We also sought to identify the variables that persuade expert surgeons to choose a deltoid sparing rather than deltoid resecting procedure. Patients and Methods. We reviewed 45 patients who had undergone resection of a primary malignant tumour of the proximal humerus. There were 29 in the deltoid sparing group and 16 in the deltoid resecting group. Imaging studies were reviewed to assess tumour extension and soft-tissue involvement. The presence of a fat rim separating the tumour from the deltoid on MRI was particularly noted. The cumulative probability of local recurrence was calculated in a competing risk scenario. Results. There was no significant difference (adjusted p = 0.89) in the cumulative probability of local recurrence between the deltoid sparing (7%, 95% confidence interval (CI) 1 to 20) and the deltoid resecting group (26%, 95% CI 8 to 50). Patients were more likely to be selected for a deltoid sparing procedure if they presented with a small tumour (p = 0.0064) with less bone involvement (p = 0.032) and a continuous fat rim on MRI (p = 0.002) and if the axillary nerve could be identified (p = 0.037). Conclusion. A deltoid sparing procedure can provide good local control after resection of the proximal humerus for a primary malignant bone tumour. A smaller tumour, the presence of a continuous fat rim and the identification of the axillary nerve on pre-operative MRI will persuade surgeons to opt for a deltoid resecting procedure. Cite this article: Bone Joint J 2017;99-B:1244–9


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 927 - 933
1 Jul 2017
Poltaretskyi S Chaoui J Mayya M Hamitouche C Bercik MJ Boileau P Walch G

Aims. Restoring the pre-morbid anatomy of the proximal humerus is a goal of anatomical shoulder arthroplasty, but reliance is placed on the surgeon’s experience and on anatomical estimations. The purpose of this study was to present a novel method, ‘Statistical Shape Modelling’, which accurately predicts the pre-morbid proximal humeral anatomy and calculates the 3D geometric parameters needed to restore normal anatomy in patients with severe degenerative osteoarthritis or a fracture of the proximal humerus. Materials and Methods. From a database of 57 humeral CT scans 3D humeral reconstructions were manually created. The reconstructions were used to construct a statistical shape model (SSM), which was then tested on a second set of 52 scans. For each humerus in the second set, 3D reconstructions of four diaphyseal segments of varying lengths were created. These reconstructions were chosen to mimic severe osteoarthritis, a fracture of the surgical neck of the humerus and a proximal humeral fracture with diaphyseal extension. The SSM was then applied to the diaphyseal segments to see how well it predicted proximal morphology, using the actual proximal humeral morphology for comparison. Results. With the metaphysis included, mimicking osteoarthritis, the errors of prediction for retroversion, inclination, height, radius of curvature and posterior and medial offset of the head of the humerus were 2.9° (± 2.3°), 4.0° (± 3.3°), 1.0 mm (± 0.8 mm), 0.8 mm (± 0.6 mm), 0.7 mm (± 0.5 mm) and 1.0 mm (± 0.7 mm), respectively. With the metaphysis excluded, mimicking a fracture of the surgical neck, the errors of prediction for retroversion, inclination, height, radius of curvature and posterior and medial offset of the head of the humerus were 3.8° (± 2.9°), 3.9° (± 3.4°), 2.4 mm (± 1.9 mm), 1.3 mm (± 0.9 mm), 0.8 mm (± 0.5 mm) and 0.9 mm (± 0.6 mm), respectively. Conclusion. This study reports a novel, computerised method that accurately predicts the pre-morbid proximal humeral anatomy even in challenging situations. This information can be used in the surgical planning and operative reconstruction of patients with severe degenerative osteoarthritis or with a fracture of the proximal humerus. Cite this article: Bone Joint J 2017;99-B:927–33


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 4 - 4
1 Nov 2022
Adapa A Shetty S Kumar A Pai S
Full Access

Abstract. Background. Fractures Proximal humerus account for nearly 10 % of geriatric fractures. The treatment options varies. There is no consensus regarding the optimal treatment, with almost all modalities giving functionally poor outcomes. Hence literature recommends conservative management over surgical options. MULTILOC nail with its design seems to be a promising tool in treating these fractures. We hereby report our early experience in the treatment of 37 elderly patients. Objectives. To evaluate the radiological outcome with regards to union, collapse, screw back out/cut through, implant failures, Greater tuberosity migration. To evaluate the functional outcome at the end of 6 months using Constant score. Study Design & Methods. All patients aged >65 years who underwent surgery for 3,4-part fracture proximal humerus using the MULTILOC nail were included in the study after consent. Pre – existing rotator cuff disease were excluded. Within the time frame, a total of 39 patients underwent the said surgery. 2 patients were lost to follow up. All the measurements were taken at the end of 6 months and results tabulated and analysed. Results. Union was achieved in all the 37 patients. There were no varus collapse or screw backout/cut through seen in any of the patients. There was Greater tuberosity migration in 1 patient who underwent revision surgery at 6 weeks. All the patients got a minimum of 70 degrees of abduction and forward flexion. We had 29 excellent, 6 good, 2 fair and none poor results as per Constant scoring system. Study done in Tejasvini Hospital & SSIOT Mangaluru India


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 707 - 712
1 May 2010
Siegel HJ Lopez-Ben R Mann JP Ponce BA

Bone loss secondary to primary or metastatic lesions of the proximal humerus remains a challenging surgical problem. Options include preservation of the joint with stabilisation using internal fixation or resection of the tumour with prosthetic replacement. Resection of the proximal humerus often includes the greater tuberosity and adjacent diaphysis, which may result in poor function secondary to loss of the rotator cuff and/or deltoid function. Preservation of the joint with internal fixation may reduce the time in hospital and peri-operative morbidity compared with joint replacement, and result in a better functional outcome. We included 32 patients with pathological fractures of the proximal humerus in this study. Functional and radiological assessments were performed. At a mean follow-up of 17.6 months (8 to 61) there was no radiological evidence of failure of fixation. The mean revised musculoskeletal Tumour Society functional score was 94.6% (86% to 99%). There was recurrent tumour requiring further surgery in four patients (12.5%). Of the 22 patients who were employed prior to presentation all returned to work without restrictions. The use of a locking plate combined with augmentation with cement extends the indications for salvage of the proximal humerus with good function in patients with pathological and impending pathological fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1403 - 1409
1 Oct 2010
Pape G Zeifang F Bruckner T Raiss P Rickert M Loew M

Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option. A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score. According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p < 0.039). Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 23 - 23
1 Jan 2017
Inyang A Dey R Mutsvangwa T Roche S Sivarasu S
Full Access

The morphology of the proximal part of the humerus varies largely. Morphometric features characterizing the three-dimensional geometry of the proximal humerus have revealed a wide difference within individuals. These parameters include head size, radius of curvature, inclination angle, retroversion angle, offsets and neck-shaft angle. Different implant designs have been adapted so as to make provision for these anatomical variations. However, the optimal design criteria are yet to be established. Implant design is one of the main factors determining the success of Total Shoulder Arthroplasty (TSA) since slight modifications in the implant anatomy could have significant biomechanical effects. Therefore, this study investigates the three-dimensional morphometric parameters of the South African proximal humerus which will serve as a basis for designing a new Total Shoulder Prosthesis for the South African population. Sixteen South African (SA) fresh cadaveric humeri (8 left, 8 right; 8 paired) were used in this study. The data consisted of 6 men and 2 women with ages ranging from 32 to 55 years (43.13 ±8.51). The humeri were scanned using a Computer Tomography (CT) scanner. The Digital Imaging and Communications in Medicine (DICOM) files from the CT data were imported into medical modelling software, MIMICS for reconstruction. The 3D reconstructed model of the humeri as an STL file was used for further processing. The STL data were generated as a cloud of points in a CAD software, SolidWorks. These were then remodeled by defining the detailed Referential Geometric Entities (RGEs) describing the anatomical characteristics. Anatomical reference points were defined for the anatomical neck plane, the epiphyseal sphere and the metaphyseal cylinder. Also, axes were defined which comprises of the humeral head axis and the metaphyseal axis. Thereafter, the posterior offsets medial offsets and the inclination angles were measured based on the RGEs. The posterior offset varied from 0.07 mm to 2.87 mm (mean 1.20 mm), the medial offset varied from 4.40 mm to 8.45 mm (mean 6.50 mm) while the inclination angle varied from 114.00º to 133.87º (mean 121.05º). The outcome of the study showed that the shape and dimensions of the proximal humerus varies distinctively. The articular surface is not a perfect sphere and differs independently with respect to the inclination angles. In addition, variations were noticeable in the medial and lateral offsets. The morphometric data on the African shoulder is very limited and this study will significantly contribute to the shoulder data repository for the SA population. The morphometric parameters measured in this study will be useful in designing a South African shoulder prosthesis that mimics the native shoulder hence eliminating post-surgical complications


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 380 - 380
1 Sep 2005
Volpin G Shtarker H Kaushanski A Shachar R Daniel M
Full Access

Introduction: The treatment of fractures of the proximal humerus is still controversial. Conservative treatment may result in severe disability due to malunion and shoulder stiffness. Open reduction and rigid fixation requires extensive soft tissue exposure, which may results in a high incidence of avascular necrosis of the proximal humerus. We present our experience with “minimal invasive” surgical techniques of such fractures. Materials & Methods: This study consists of 128 Pts. (52 M, 76 F, 18–84 year old, mean 53.5Y) followed for 2–7 years (mean 3.5Y), treated by closed reduction and percutaneous pinning (55), by ORIF and minimal osteosynthesis by screws (27), by ORIF with rigid plates (7), and by hemiarthroplasty of the proximal humerus (39). Patients were evaluated by the Neer’s shoulder grading score and radiographs. Results: Overall results were excellent and good in 85% of patients with 2, and 3 parts fractures of the proximal humerus treated by “minimal invasive” fixation techniques, with some better results in less comminuted fractures. 9/14 young patients with 4 part fractures had good functional results. The other 5 patients had poor results and 3 of them developed AVN of the humeral head. 75% of the patients treated by hemiarthroplasty had satisfactory results. They were almost free of pain, but most of them had only a moderate improvement in shoulder motion. Discussion: Based on this study it seems that “minimal osteosynthesis” by K.W. techniques, lag screws or rush pins, by closed or open reduction, remains as the first optional treatment of complex fractures of the shoulder, even in young patients with a 4 part fracture. In the elderly, hemiarthroplasty should be considered in such pathology as the treatment of choice


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 221 - 221
1 Mar 2010
Rosenfeldt M French J Gray D Flint M
Full Access

The proximal humerus is the third most common site for primary sarcoma of bone. Since the 1970’s the treatment of primary bone sarcoma has changed from amputation to limb salvage. This has been due to advances in chemotherapy, imaging and surgical techniques. The literature has shown that the survival after limb salvage is similar to that of amputation. The optimum method of reconstruction of the shoulder remains controversial. The aim of our study was to review the cases of primary bone sarcoma of the proximal humerus treated at Middlemore Hospital. The New Zealand Bone Tumour Registry was searched for all lesions of the proximal humerus, with the diagnosis of chondrosarcoma, Ewing’s sarcoma or osteosarcoma. These records were reviewed for presentation status, biopsy, and type of reconstruct ion, chemotherapy, complications and recurrence. Outcomes measured in months of disease free survival and overall survival. The Bone Tumour Registry identified 29 patients who were treated at Middlemore Hospital with the primary diagnosis of Ewing’s sarcoma, chondrosarcoma or osteosarcoma of the proximal humerus. Results were available for 26 of the 29 patients (90% follow-up). Of these 29 patients six had chondrosarcoma, four Ewing’s sarcoma and 19 osteosarcoma. The patients with chondrosarcoma had an average age of 50 years. three patients were treated with endoprosthesis (mean survival 48 months) and one with vascularised fibula reconstruction (status 27 months ANED). Of the four patients with Ewing’s sarcoma, two had surgical reconstruction, one with intercalary allograft reconstruction (status 96 months ANED) and one with endoprosthesis (status 84 months ANED). The 19 patients with osteosarcoma had an average age 27 years, 15 patients were treated surgically. Three had endoprosthetic reconstruction (mean survival 29 months), two allograft prosthetic composite reconstruction (mean survival 23 months), three vascularised fibula reconstruction (mean survival 217 months), one total shoulder replacement and proximal humeral autograft (status 68 months ANED), one hemiarthroplasty (status 21 months DOD) and one proximal humeral allograft (status 31 months ANED). 4 patients were treated with primary amputation (mean survival 55.25 months). The mean overall survival for limb salvage surgery in our institution is 74 months compared to 55.25 months for amputation; this is consistent with the published literature. Function of a salvaged upper limb is superior to amputation. A salvaged limb is socially and emotionally more acceptable for patients than amputation. Limb salvage remains the priority in the treatment of primary bone tumours of the proximal humerus


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 857 - 865
1 Sep 1997
Boileau P Walch G

We have studied the three-dimensional geometry of the proximal humerus on human cadaver specimens using a digitised measuring device linked to a computer. Our findings demonstrated the variable shape of the proximal humerus as well as its variable dimensions. The articular surface, which is part of a sphere varies individually in its orientation as regards inclination and retroversion, and it has variable medial and posterior offsets. These variations cannot be accommodated by the designs of most contemporary humeral components. Although good clinical results can be achieved with current modular and non-modular components their relatively fixed geometry prevents truly anatomical restoration in many cases. To try to restore the original three-dimensional geometry of the proximal humerus, we have developed a new type of humeral component which is modular and adaptable to the individual anatomy. Such adaptability allows correct positioning of the prosthetic head in relation to an individual anatomical neck, after removal of the marginal osteophytes. The design of this third-generation prosthesis respects the four geometrical variations which have been demonstrated in the present study. These are inclination, retroversion, medial offset and posterior offset


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 34 - 34
1 Apr 2012
Lehner B Depeweg D Egermann M Raiss P
Full Access

Aim. The aim of this study was to analyze our results using a modular endoprosthetic replacement system (MUTARS) for bone tumours of the proximal humerus. Methods. Thirty-nine patients were treated with a MUTARS endoprosthesis of the proximal humerus. Mean follow-up was 38 months (3-138 months). Most operations were necessitated by metastasis (n=30); surgery for a primary tumour (n=9) was less frequent. The Enneking score and the active ranges of motion for shoulder flexion, abduction, and external rotation were recorded. Complete refixation of the rotator cuff was possible in 23 cases. Radiographs also were obtained. Results. Patient survival was 77% at 2 years and 45% at 11.5 years after surgery. The survival rate of the limb was 90% at 11.5 years. The mean Enneking score was 19 points (range 7-27 points). The mean shoulder flexion was 34 degrees (range 0-90 degrees), abduction 33 degrees (range 0-90 degrees), and external rotation 12 degrees (range 10-50 degrees). Patients with a complete rotator cuff repair showed a significant better range of motion compared to patients with a partial or no repair (p<0.015). No signs of implant loosening were observed on postoperative radiographs. Seven complications occurred, five of them leading to implant revision. At 11.5 years after surgery, the survival rate for the whole cohort without complications was 72%, without revision of the implant 70%. Conclusion. Replacement of the proximal humerus with MUTARS endoprosthesis is a viable treatment option for bone tumours with satisfying results


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 106 - 106
1 Mar 2008
Laflamme G Berry G Gagnon S Beaumont P
Full Access

Although new locking plates allows for secure fixation of osteoporotic fractures in the proximal humerus, extensive soft tissue dissection is needed for their insertion. We report on a prospective clinical trial of the first thirty patients treated with plating of the proximal humerus though a minimally invasive percutaneous approach. All fractures healed within the first 6 months with no avascular necrosis or axillary nerve injury. At the latest follow-up, the median Constant score was sixty-eight and the mean DASH score was twenty-seven. This study suggests that percutaneous plating can be a safe and effective method of fixation. To evaluate the safety and efficacy of minimally invasive plating of the proximal humerus using validated disease-specific measures. Percutaneous insertion of a locking proximal humerus plate is safe and produces good early functional and radiologic outcomes. Plate fixation of the proximal humerus fractures may now be more desirable with the use of a biological approach by limiting surgical insult and allowing accelerated rehabilitation. All fractures healed within the first six months with no loss of correction. Two reoperations were needed to remove intra-articular screws placed too long. No infection or avascular necrosis were seen. At the lastest follow-up, the median Constant score was sixty-eight points, with an age ajusted score of seventy-six. The mean DASH score was twenty-seven points. Only age was independantly predictive of both the Constant and DASH functional scores. During a period of one year, thirty patients were operated with use of the LCP proximal humerus plate (Synthes) through a 3cm lateral deltoid splitting approach and a second 2 cm incision at the deltoid insertion. The axillary nerve was palped and easily protected during insertion. Only two-part (N=22) and three-part impacted valgus type (N=8) were included in this study since they can be reduced indirectly thru this percutaneous technique. The average follow-up was thirteen months (eight to twenty months). All patients had the Constant and DASH evaluations


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 152 - 159
1 Feb 2016
Corbacho B Duarte A Keding A Handoll H Chuang LH Torgerson D Brealey S Jefferson L Hewitt C Rangan A

Aims. A pragmatic multicentre randomised controlled trial (PROFHER) was conducted in United Kingdom National Health Service (NHS) hospitals to evaluate the clinical effectiveness and cost effectiveness of surgery compared with non-surgical treatment for displaced fractures of the proximal humerus involving the surgical neck in adults. . Methods. A cost utility analysis from the NHS perspective was performed. Differences between surgical and non-surgical treatment groups in costs and quality adjusted life years (QALYs) at two years were used to derive an estimate of the cost effectiveness of surgery using regression methods. . Results. Patients randomised to receive surgical intervention accumulated mean greater costs and marginally lower QALYs than patients randomised to non-surgery. The surgical intervention cost a mean of £1758 more per patient (95% confidence intervals (CI) £1126 to £2389). Total QALYs for the surgical group were smaller than those for non-surgery -0.0101 (95% CI -0.13 to 0.11). The probability of surgery being cost effective was less than 10% given the current NICE willingness to pay at a threshold of £20 000 for an additional QALY. The results were robust to sensitivity analyses. Discussion. The results suggest that current surgical treatment is not cost effective for the majority of displaced fractures of the proximal humerus involving the surgical neck in the United Kingdom’s NHS. Take home message: The results of this trial do not support the trend of increased surgical treatment for patients with displaced fractures of the proximal humerus involving the surgical neck within the United Kingdom NHS. Cite this article: Bone Joint J 2016;98-B:152–9


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 40 - 40
1 Mar 2009
Farron A Cikes A Brenn S Wettstein M Chevalley F
Full Access

Introduction: Locking plates and screws have been developed to increase stability of internal fixation in osteoporotic bone. The anatomic design should also facilitate the fracture’s reduction in complex cases. The aim of this study was analyse the results of locking plates used for fractures of the proximal humerus and to look for specific complications. Method: Forty four patients (mean age 60; 28 males and 16 females) were treated with a locking plate (Philos, Synthes-Sratec Medical, Switzerland) for trauma of the proximal humerus. There were fourteen 2-part (32%), ten 3-part (23%), ten valgus impacted 4-part (23%), 3 classical 4-part (7%) fractures and 7 non-unions (15%). Five patients presented an associated gleno-humeral dislocation. Patients were reviewed clinically and radiologically at a mean follow-up of 21 months (6–42). A particular attention was paid to the occurrence of specific complications. Results: A deep infection occurred in two patients (4,5%); two others lost the reduction (4,5%), and one broke his plate (2,3%). We observed 9 cases (20,5%) of avascular necrosis. Six patients (13,6%) had an impaction of the fracture with secondary intraarticular protrusion of the locked screws, which induced a secondary glenoid wear. The impaction sometimes occurred even without any evidence of AVN. Protrusion of screws were more frequent in elderly patients or in cases of non-union. Revision surgery (18 operations) was performed in 16 patients (36%) : 9 isolated material removal; 3 revisions for loss of reduction and malposition of the plate; 2 debridement including implantation of a cement spacer with antibiotics; 4 arthroplasties (2 hemi and 2 total shoulder prostheses). Conclusions: Proximal humerus locking plates and screws, designed to improve stability in osteoporotic bone, may have specific complications. They do not prevent fracture’s impaction, resulting in an intraarticular protrusion of the locked screws, which may induce a severe secondary wear of the glenoid. This phenomenon could be due to the direction of the forces and stresses applied on the humeral head, which is mainly parallel to the screws and not perpendicular to them. Accordingly, patients operated on with proximal humerus locking plates should be regularly controlled. In case of progressive humeral head impaction, the material should be removed before it damages the glenoid


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1521 - 1523
1 Nov 2006
Wera GD Friess DM Getty PO Armstrong DG Lacey SH Baele HR

Fractures of the proximal humerus with concomitant vascular injury are rare in children. We describe the presentation, diagnosis, and treatment of a fracture of the proximal humerus in association with an axillary artery injury in a child