Advertisement for orthosearch.org.uk
Results 1 - 20 of 199
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 45 - 45
1 Nov 2021
Sugano N Hamada H Takao M Ando W Uemura K Nakamura N
Full Access

The purposes of this study were to evaluate the accuracy and feasibility of a robotic preparation for acetabular metal augments in patients with developmental dysplasia of the hip (DDH). Mako robotic arm reaming was used in 7 DDH to prepare the bony cavities for both Trident PSL cups and Tritanium acetabular wedge augments in six hips with Crowe 2 or 3 DDH. In CT-based planning, a properly sized cup was placed in the original acetabulum, and the same sized cup was also placed to fit the superolateral acetabular defect. The coordinates of the planned positions of cup and augment were recorded to manage the robotic arm reaming. After registration of the patient's pelvis, robotic reaming was performed first for the augment, then, for the cup by changing the target position of reaming as planned. The accuracy of the cup and augment placement was assessed on postoperative CT. To evaluate the feasibility of the robotic procedure, the OR time and blood loss were compared with those of 13 patients who received the same cup and augment systems with a conventional technique. All procedures were done without fracture or fixation failure. There were no differences in OR time or blood loss between the two procedures. Postoperative CT measurements of the distance between the cup center and the augment sphere center showed less than 2mm difference from the Mako preoperative planning. Although a longer time of follow up evaluation is mandatory, our robotic acetabular augment preparation technique is accurate and feasible


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims. Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. Methods. We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. Results. Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. Conclusion. Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation. Cite this article: Bone Jt Open 2022;3(12):991–997


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 52 - 56
1 Jul 2020
Elkins JM Dennis DA Kleeman-Forsthuber L Yang CC Miner TM Jennings JM

Aims. Of growing concern in arthroplasty is the emergence of atypical infections, particularly Cutibacterium (formerly Propionibacterium) sp. infections. Currently, the dermal colonization rate of Cutibacterium about the hip is unknown. Therefore, the aim of this study was to investigate colonization rates of Cutibacterium sp. at locations approximating anterior and posterolateral approaches to the hip joint. Methods. For this non-randomized non-blinded study, 101 adult patients scheduled for hip or knee surgery were recruited. For each, four 3 mm dermal punch biopsies were collected after administration of anaesthesia, but prior to antibiotics. Prebiopsy skin preparation consisted of a standardized preoperative 2% chlorhexidine skin cleansing protocol and an additional 70% isopropyl alcohol mechanical skin scrub immediately prior to biopsy collection. Two skin samples 10 cm apart were collected from a location approximating a standard direct anterior skin incision, and two samples 10 cm apart were collected from a lateral skin incision (suitable for posterior, direct-lateral, or anterolateral approaches). Samples were cultured for two weeks using a protocol optimized for Cutibacterium. Results. A total of 23 out of 404 cultures (collected from 101 patients) were positive for a microorganism, with a total of 22 patients having a positive culture (22%). Overall, 15 of the cultures in 14 patients were positive for Cutibacterium sp. (65%), of which Cutibacterium acnes comprised the majority (n = 13; 87%). Other isolated microorganisms include coagulase-negative Staphylococcus (n = 6), Clostridium (n = 1), and Corynebacterium (n = 1). Of all positive cultures, 15 were obtained from the anterior location (65%), of which seven (60%) were from the most proximal biopsy location. However, these findings were not statistically significant (anterior vs lateral, p = 0.076; proximal vs distal, p =0.238). Conclusion. Approximately 14% (14/101) of the patients demonstrated a positive Cutibacterium colonization about the hip, the majority anteriorly. Given the high colonization rate of Cutibacterium, alternative skin preparations for total hip arthroplasty should be considered. Cite this article: Bone Joint J 2020;102-B(7 Supple B):52–56


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 58 - 58
19 Aug 2024
Karachalios T Hasan Y Aqeel M
Full Access

Total hip arthroplasty (THA) has proved to be an effective treatment modality for sickle-cell hip arthropathy (mosaic-like dense bone due to infarcts). However, mode of failure, survival rates and challenges associated with revision hip arthroplasty in sickle-cell disease patients are mostly unknown. We retrospectively evaluated prospectively collected data from all patients with sickle-cell disease who underwent revision hip arthroplasty from 2016. Patient, surgery, medical and surgical complications related data were collected. The pinnacle and reclaim revision system with gription augments (JJ) was used in all patients. Pre-op and post-op clinical outcome data (both objective and subjective, HOOS Jr and OHS) were recorded. Cumulative success rates were recorded with re-revision surgery as an end point. We performed fifteen revision THAs on 13 patients (mean follow up of 6.6 years). The mean age of the patients was 48 years (range, 30–59). At final follow-up, a statistically significant improvement of mean OHS and HOOS JR scores eas found in all patients. reported (OHS: 34.0 and HOOS JR: 77.7). Cumulative success rate was 100% for re-revision for all reasons at 6 years. Five intensive care unit (ITU) admissions, two vaso-occlusive sickle cell crises, one transfusion-related complication and one acute chest syndrome (ACS) were recorded. On admission, the mean percentage of HbS was 75.25% (64.6–86.4%). Revision arthroplasty in sickle-cell disease patients poses increased risks, with medical and surgical challenges. However, with careful preparation, planning and a multi-disciplinary team approach, revision arthroplasty can result in excellent clinical outcomes and excellent functional scores in the majority of patients in the short and mid-term


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1035 - 1042
1 Dec 2021
Okowinski M Hjorth MH Mosegaard SB Jürgens-Lahnstein JH Storgaard Jakobsen S Hedevang Christensen P Kold S Stilling M

Aims. Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes. Methods. A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications. Results. Over a mean follow-up period of 10.6 years, the mean stem subsidence was similar between groups, with a mean of -1.20 mm (95% confidence interval (CI) -2.28 to -0.12) in the broaching group and a mean of -0.73 mm (95% CI -1.65 to 0.20) in the compaction group (p = 0.07). The long-term migration patterns of all stems were similar. The clinical and radiological outcomes were similar between groups. There were two intraoperative fractures in the compaction group that were fixed with cable wire and healed without complications. No stems were revised. Conclusion. Similar stem subsidence and radiological and clinical outcomes were identified after the use of compaction and broaching techniques of the femur at long-term follow-up. Only the compaction group had intraoperative periprosthetic femur fractures, but there were no long-term consequences of these. Cite this article: Bone Jt Open 2021;2(12):1035–1042


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 19 - 19
1 Apr 2022
Lim A Zhu J Khanduja V
Full Access

There are a number of patients in whom hip preservation surgery is not indicated as they have developed signs of early osteoarthritis, and nor can they have a hip replacement as they are too early in the disease process. The use of PRP in OA of the hip has not been studied systematically and this study concisely collates all the available data in the use of PRP in Hip OA. This systematic review and meta-analysis aimed to assess intra-articular platelet-rich plasma as a therapeutic intervention for hip osteoarthritis, including the duration of efficacy, influence of dose and composition of PRP, and the incidence of adverse effects. We performed literature searches on the MEDLINE, EMBASE, CINHAL, WEB OF SCIENCE, COCHRANE and SCOPUS databases, and PRSIMA guidelines were followed. Data was pooled using random effects meta-analysis. We assessed quality of the included studies using the Methodological Index for Non-Randomised Studies (MINORS) instrument, with an additional assessment for Randomised Controlled Trials with the Revised Cochrane risk-of-bias tool for randomized trials (RoB 2). Eight studies were included in the analysis, with data from a total of 331 patients. PRP significantly reduced pain compared to baseline at multiple timepoints, with the greatest effect at 1–2mo follow-up. PRP only significantly improved function at the 1–2mo follow-up. A significantly larger reduction in pain was achieved with a single injection or PRP compared to multiple injections, a total injected dose of PRP <15mL compared to ≥15mL or using a leukocyte-poor PRP preparation compared to leukocyte-rich PRP. There were no lasting adverse effects. Low and moderate quality evidence suggests that PRP reduces pain and improves function at endpoint compared to baseline. Moderate quality evidence suggests a larger reduction in pain is achieved with a single injection of PRP compared to multiple injections, and low quality evidence attributes a larger reduction of pain with a total injected dose of PRP <15mL compared to ≥15mL or using leukocyte-poor PRP compared to leukocyte-rich PRP


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 55 - 55
1 Oct 2020
Barnes CL
Full Access

Introduction. Recent literature has sought to quantify pre-operative work associated with total joint arthroplasty. These studies have utilized surveys or self-reported time logs to estimate the Pre-op Optimization Work (POW) completed by the surgical team. The purpose of this study was to objectively quantify POW associated with total hip arthroplasty (THA) using electronic medical record (EMR) activity audit logs. Methods. Retrospective analysis of EMR activity for 4 arthroplasty surgeons and their clinical staff was collected for 100 consecutive THA cases (25 per surgeon). Clinical informatics data was generated using EMR activity audit logs for pre-THA activity. Every action and mouse-click within a patient's chart was recorded for each team member. The time between mouse-clicks was calculated and summed for each user. Times exceeding five minutes without activity were assumed to reflect inactivity and excluded. Descriptive statistics were used to estimate the POW associated with THA preparation. Results. The mean number of days for pre-THA time period was70.7 (SD43.9; range: 8–175days). During this period, the mean time spent in each patient's chart was 75.5 minutes (SD50.75) minutes. Surgeon's POW in the medical record accounted for 7.3(SD6.7) of these minutes. Much of the work was conducted by nurses (47.0 minutes, SD43.4), physician extenders (10.8 minutes, SD 13.1), and qualified office staff/technicians (10.4 minutes, SD14.9). The majority of work captured in the EMR activity log was associated with medication review, patient optimization, documentation of necessary medical clearances, ordersets, patient communication, and prior authorization requests. Conclusion. A considerable amount of preoperative work is required between the clinic date a patient decides to pursue THA and the day prior to surgery. These retrospective electronic time stamp measurements should represent the absolute minimum time required for surgical preparation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 27 - 27
1 May 2019
Logishetty K Rudran B Gofton W Beaule P Cobb J
Full Access

Background. Virtual Reality (VR) uses headsets and motion-tracked controllers so surgeons can perform simulated total hip arthroplasty (THA) in a fully-immersive, interactive 3D operating theatre. The aim of this study was to investigate the effect of laboratory-based VR training on the ability of surgical trainees to perform direct anterior approach THA on cadavers. Methods. Eighteen surgical trainees (CT1-ST4) with no prior experience of direct anterior approach (DAA) THA completed an intensive 1-day course (lectures, dry-bone workshops and technique demonstrations). They were randomised to either a 5-week protocol of VR simulator training or conventional preparation (operation manuals and observation of real surgery). Trainees performed DAA-THA on cadaveric hips, assisted by a passive scrub nurse and surgical assistant. Performance was measured on the Intercollegiate Surgical Curriculum Project (ISCP) procedure-based assessment (PBA), on a 9-point global summary score (Table 1). This was independently assessed by 2 hip surgeons blinded to group allocation. The secondary outcome measure was error in cup orientation from a predefined target (40° inclination and 20° anteversion). Results. Surgeons trained using VR performed a cadaveric DAA-THA significantly better than those using conventional preparation, as assessed by acetabular cup orientation (p<0.001) and using the ISCP-PBA. Two VR surgeons achieved Level 3b, 6 were graded at Level 3a, and 1 was graded at Level 2b. Six non-VR surgeons achieved Level 2a and 3 were graded at Level 1b. Discussion. These data demonstrate transfer of procedural knowledge and psychomotor skills learnt from VR to a real-world setting. Conventional preparation had limited value for novice surgeons learning arthroplasty. VR training advanced them further up the learning curve. Implications. Virtual reality can augment surgical training for open procedures in orthopaedics curve, so opportunities in real surgery can be maximised. This has implications for how surgical training is delivered for surgeons learning a new, complex procedure. For any figures or tables, please contact the authors directly


Bone & Joint Open
Vol. 1, Issue 9 | Pages 530 - 540
4 Sep 2020
Arafa M Nesar S Abu-Jabeh H Jayme MOR Kalairajah Y

Aims. The coronavirus disease (COVID)-19 pandemic forced an unprecedented period of challenge to the NHS in the UK where hip fractures in the elderly population are a major public health concern. There are approximately 76,000 hip fractures in the UK each year which make up a substantial proportion of the trauma workload of an average orthopaedic unit. This study aims to assess the impact of the COVID-19 pandemic on hip fracture care service and the emerging lessons to withstand any future outbreaks. Methods. Data were collected retrospectively on 157 hip fractures admitted from March to May 2019 and 2020. The 2020 group was further subdivided into COVID-positive and COVID-negative. Data including the four-hour target, timing to imaging, hours to operation, anaesthetic and operative details, intraoperative complications, postoperative reviews, COVID status, Key Performance Indicators (KPIs), length of stay, postoperative complications, and the 30-day mortality were compiled from computer records and our local National Hip Fracture Database (NHFD) export data. Results. Hip fractures and inpatient falls significantly increased by 61.7% and 7.2% respectively in the 2020 group. A significant difference was found among the three groups regarding anaesthetic preparation time, anaesthetic time, and recovery time. The mortality rate in the 2020 COVID-positive group (36.8%) was significantly higher than both the 2020 COVID-negative and 2019 groups (11.5% and 11.7% respectively). The hospital stay was significantly higher in the COVID-positive group (mean of 24.21 days (SD 19.29)). Conclusion. COVID-19 has had notable effects on the hip fracture care service: hip fracture rates increased significantly. There were inefficiencies in theatre processes for which we have recommended the use of alternate theatres. COVID-19 infection increased the 30-day mortality and hospital stay in hip fractures. More research needs to be done to reduce this risk. Cite this article: Bone Joint Open 2020;1-9:530–540


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 71 - 77
1 Jul 2020
Gonzalez Della Valle A Shanaghan KA Nguyen J Liu J Memtsoudis S Sharrock NE Salvati EA

Aims. We studied the safety and efficacy of multimodal thromboprophylaxis in patients with a history of venous thromboembolism (VTE) who undergo total hip arthroplasty (THA) within the first 120 postoperative days, and the mortality during the first year. Multimodal prophylaxis includes discontinuation of procoagulant medications, VTE risk stratification, regional anaesthesia, an intravenous bolus of unfractionated heparin prior to femoral preparation, rapid mobilization, the use of pneumatic compression devices, and chemoprophylaxis tailored to the patient’s risk of VTE. Methods. Between 2004 to 2018, 257 patients with a proven history of VTE underwent 277 primary elective THA procedures by two surgeons at a single institution. The patients had a history of deep vein thrombosis (DVT) (186, 67%), pulmonary embolism (PE) (43, 15.5%), or both (48, 17.5%). Chemoprophylaxis included aspirin (38 patients), anticoagulation (215 patients), or a combination of aspirin and anticoagulation (24 patients). A total of 50 patients (18%) had a vena cava filter in situ at the time of surgery. Patients were followed for 120 days to record complications, and for one year to record mortality. Results. Postoperative VTE was diagnosed in seven patients (2.5%): DVT in five, and PE with and without DVT in one patient each. After hospitalization, three patients required readmiss-ion for evacuation of a haematoma, one for wound drainage, and one for monitoring of an elevated international normalized ratio (INR). Seven patients died (2.5%). One patient died five months postoperatively of a PE during open thrombectomy. She had discontinued anticoagulation. One patient died of a haemorrhagic stroke while receiving Coumadin. PE or bleeding was not suspected in the remaining five fatalities. Conclusion. Multimodal prophylaxis is safe and effective in patients with a history of VTE. Postoperative anticoagulation should be prudent as very few patients developed VTE (2.5%) or died of suspected or confirmed PE. Mortality during the first year was mostly unrelated to either VTE or bleeding. Cite this article: Bone Joint J 2020;102-B(7 Supple B):71–77


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 299 - 304
1 Feb 2021
Goto E Umeda H Otsubo M Teranishi T

Aims. Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck. Methods. A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using bone graft from the femoral neck between 1979 and 2000. A Charnley cemented acetabular component was placed at the level of the true acetabulum after preparation with bone grafting. All patients were female with a mean age at the time of surgery of 54 years (35 to 68). A total of 18 patients (21 THAs) were followed for a mean of 27.2 years (20 to 33) after the operation. Results. Radiographs immediately after surgery showed a mean vertical distance from the centre of the hip to the teardrop line of 21.5 mm (SD 3.3; 14.5 to 30.7) and a mean cover of the acetabular component by bone graft of 46% (SD 6%; 32% to 60%). All bone grafts united without collapse, and only three acetabular components loosened. The rate of survival of the acetabular component with mechanical loosening or revision as the endpoint was 86.4% at 25 years after surgery. Conclusion. The technique of using autologous bone graft from the femoral neck and placing a cemented acetabular component in the true acetabulum can provide good long-term outcomes in patients with Crowe type III dislocated hips. Cite this article: Bone Joint J 2021;103-B(2):299–304


Bone & Joint Research
Vol. 8, Issue 6 | Pages 246 - 252
1 Jun 2019
Liddle A Webb M Clement N Green S Liddle J German M Holland J

Objectives. Previous studies have evidenced cement-in-cement techniques as reliable in revision arthroplasty. Commonly, the original cement mantle is reshaped, aiding accurate placement of the new stem. Ultrasonic devices selectively remove cement, preserve host bone, and have lower cortical perforation rates than other techniques. As far as the authors are aware, the impact of ultrasonic devices on final cement-in-cement bonds has not been investigated. This study assessed the impact of cement removal using the Orthosonics System for Cemented Arthroplasty Revision (OSCAR; Orthosonics) on final cement-in-cement bonds. Methods. A total of 24 specimens were manufactured by pouring cement (Simplex P Bone Cement; Stryker) into stainless steel moulds, with a central rod polished to Stryker Exeter V40 specifications. After cement curing, the rods were removed and eight specimens were allocated to each of three internal surface preparation groups: 1) burr; 2) OSCAR; and 3) no treatment. Internal holes were recemented, and each specimen was cut into 5 mm discs. Shear testing of discs was completed by a technician blinded to the original grouping, recording ultimate shear strengths. Scanning electron microscopy (SEM) was completed, inspecting surfaces of shear-tested specimens. Results. The mean shear strength for OSCAR-prepared specimens (33.6 MPa) was significantly lower than for the control (46.3 MPa) and burr (45.8 MPa) groups (p < 0.001; one-way analysis of variance (ANOVA) with Tukey’s post hoc analysis). There was no significant difference in shear strengths between control and burr groups (p = 0.57). Scanning electron microscopy of OSCAR specimens revealed evidence of porosity undiscovered in previous studies. Conclusion. Results show that the cement removal technique impacts on final cement-in-cement bonds. This in vitro study demonstrates significantly weaker bonds when using OSCAR prior to recementation into an old cement mantle compared with cement prepared with a burr or no treatment. This infers that care must be taken in surgical decision-making regarding cement removal techniques used during cement-in-cement revision arthroplasty, suggesting that the risks and benefits of ultrasonic cement removal need consideration. Cite this article: A. Liddle, M. Webb, N. Clement, S. Green, J. Liddle, M. German, J. Holland. Ultrasonic cement removal in cement-in-cement revision total hip arthroplasty: What is the effect on the final cement-in-cement bond? Bone Joint Res 2019;8:246–252. DOI: 10.1302/2046-3758.86.BJR-2018-0313.R1


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1585 - 1592
1 Dec 2019
Logishetty K Rudran B Cobb JP

Aims. Arthroplasty skills need to be acquired safely during training, yet operative experience is increasingly hard to acquire by trainees. Virtual reality (VR) training using headsets and motion-tracked controllers can simulate complex open procedures in a fully immersive operating theatre. The present study aimed to determine if trainees trained using VR perform better than those using conventional preparation for performing total hip arthroplasty (THA). Patients and Methods. A total of 24 surgical trainees (seven female, 17 male; mean age 29 years (28 to 31)) volunteered to participate in this observer-blinded 1:1 randomized controlled trial. They had no prior experience of anterior approach THA. Of these 24 trainees, 12 completed a six-week VR training programme in a simulation laboratory, while the other 12 received only conventional preparatory materials for learning THA. All trainees then performed a cadaveric THA, assessed independently by two hip surgeons. The primary outcome was technical and non-technical surgical performance measured by a THA-specific procedure-based assessment (PBA). Secondary outcomes were step completion measured by a task-specific checklist, error in acetabular component orientation, and procedure duration. Results. VR-trained surgeons performed at a higher level than controls, with a median PBA of Level 3a (procedure performed with minimal guidance or intervention) versus Level 2a (guidance required for most/all of the procedure or part performed). VR-trained surgeons completed 33% more key steps than controls (mean 22 (. sd. 3) vs 12 (. sd. 3)), were 12° more accurate in component orientation (mean error 4° (. sd. 6°) vs 16° (. sd. 17°)), and were 18% faster (mean 42 minutes (. sd. 7) vs 51 minutes (. sd. 9)). Conclusion. Procedural knowledge and psychomotor skills for THA learned in VR were transferred to cadaveric performance. Basic preparatory materials had limited value for trainees learning a new technique. VR training advanced trainees further up the learning curve, enabling highly precise component orientation and more efficient surgery. VR could augment traditional surgical training to improve how surgeons learn complex open procedures. Cite this article: Bone Joint J 2019;101-B:1585–1592


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 57 - 57
1 Jan 2018
Sugano N Hamada H Takao M Sakai T Nakamura N
Full Access

The purposes of this study were to review retrospectively the 10-year outcome of cementless total hip arthroplasty (THA) using an active robot system in the femoral canal preparation for an anatomic short stem and navigation in the cup placement through a mini incision posterior approach. We reviewed all patients who underwent THA with this procedure in 53 hips between 2004 and 2007. There were no intraoperative fracture nor navigation- or robotic-related complications. All implant sizes were same as planned ones. All cases were followed up at least two years and all implants showed bone ingrowth stable according to the Engh's criteria. After then, six patients died of unrelated causes. Two patients (three hips) could not come to the 10-year follow-up examination. The remaining 44 hips were followed for 10 to 12 years (11 years on average). There is no dislocation. The average JOA hip score improved from 48 preoperatively to 96 at the final examination. On the postoperative x-ray measurements, the average cup radiographic inclination was 39° and the radiographic anteversion was 14°. There was no stem which showed more than 2° of varus or valgus alignment. There was no case who showed more than 5mm of limb length discrepancy. Postoperative CT images of 38 hips were obtained at 2 weeks. After matching the coordinates of the pelvis and femur with the preoperative planning, we got very small differences in alignment parameters between the measured values and the planed ones. The difference differences between the plan and measured values were −0.1° in cup inclination, −1.4° in cup anteversion, stem 0.5° in coronal alignment, 0.6° in stem sagittal alignment, and −1.6° in stem anteversion, respectively. We conclude that our robotic femoral preparation for a short anatomical stem and navigated cup placement thru a mini-posterior approach was safe and feasible without affecting the accuracy of the procedure. There were no long term adverse effect of the procedure


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 898 - 906
1 Sep 2024
Kayani B Wazir MUK Mancino F Plastow R Haddad FS

Aims

The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system.

Methods

This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 21 - 21
1 Oct 2020
Amstutz HC Le Duff MJ
Full Access

Background. Hip resurfacing arthoplasty (HRA) showed promising early and mid-terms results at the beginning of the new millennium. Adverse local tissue reactions associated with metal debris considerably slowed down the implantation of HRA which use is now limited to a few specialized centers. The long term success of this procedure, however, is still largely unknown. This study aimed to provide the clinical results of a series of 400 consecutive HRA with a minimum follow-up of 20 years. Methods. All patients treated with Conserve. ®. Plus HRA between November 1996 and November 2000 were retrospectively selected and 355 patients (400 hips) were included. The clinical results of this series was previously reported in 2004 at a follow up of 2 to 6 years[1]. There were 96 women (27%) and 259 men (73%). Mean age at surgery was 48.2 ± 10.9 years. Long-term survivorship was assessed with Kaplan-Meier survival estimates. UCLA hip scores and SF-12 quality of life scores were collected at follow-up visits. Radiographic positioning of the acetabular component was assessed with the computation of the contact patch to rim (CPR) distance. Radiolucencies about the metaphyseal stem and around the acetabular component were recorded to assess the quality of the component fixation. Results. The mean time of follow up was 16.3 ± 5.5 years including 183 hips beyond 20 yrs. Nine hips were lost to follow up (2.2%) Thirty-three patients (35 hips,8.8%) died of causes unrelated to the surgery at a mean 11.9 ± 5.3 years after surgery The mean UCLA hip scores at last follow-up were 9.3 ± 1.0, 9.1 ± 1.4, 9.0 ± 1.8, and 6.9 ± 1.7 for pain, walking, function, and activity, respectively. Post-operative SF-12 scores were 48.4 ± 10.3 for the physical component and 48.5 ± 15.5 for the mental component and did not differ from those of the general US population. Fifty-five patients (60 hips) underwent revision surgery at a mean time of 9.3 ± 5.8 years. Indications for revision surgery included acetabular component loosening (12 hips), femoral component loosening (31 hips), femoral neck fracture (6 hips), wear (6 hips), sepsis (2 hips), recurrent dislocations (1 hip), acetabular component protrusion after over-reaming (1 hip) and unknown (1 hip which was revised in another center). Using any revision as an endpoint, the Kaplan-Meier survivorship was 95.2% at 5 years, 91.2% at 10 years, 87.3% at 15 years, and 83.2% at 20 years. A multivariate model for risk factor analysis showed a diagnosis of developmental dysplasia (p=0.020) and a low body mass index (typically associated with higher levels of activity) (p=0.032), to be significantly related to revision for any reason. Female sex was not a risk factor after adjustment for hip dysplasia and component size was made (Table 1). There was only 1 femoral failure (a late neck fracture 19 years after surgery) among the hips reconstructed with a cemented metaphyseal stem (n=59). Five of the 6 hips (1.5%) with wear-related failures all had mal-positioned sockets (CPR distance <10mm) and were therefore preventable. There were no cases with a high score of aseptic lymphocytic vasculitis-associated lesions (ALVAL)[2], suggesting metal sensitivity. X-ray analysis showed excellent persisting fixation in all but one hip. Conclusions. In this group of patients operated over 20 years ago, HRA keeps providing excellent pain relief and quality of life to the patients. Subsequent progress in the preparation of the femoral head has considerably reduced the failure rate on the femoral side which was the main mode of failure in this initial series[3, 4]. The 83.1% 20 year survivorship of this initial series surpasses that of total hip arthroplasties in use 20 years ago in this young patient population[5]. Life-long durability of the device is anticipated for most of the remaining patients. The established benefits of this procedure, such as a low dislocation rate, an anatomic reconstruction with physiologic loading of the proximal femur, the absence of taper corrosion, and an easy conversion if ever necessary, make HRA a preferable alternative to THA in young and active patients. For any figures, tables, or references, please contact the authors directly


Bone & Joint Open
Vol. 5, Issue 8 | Pages 688 - 696
22 Aug 2024
Hanusrichter Y Gebert C Steinbeck M Dudda M Hardes J Frieler S Jeys LM Wessling M

Aims

Custom-made partial pelvis replacements (PPRs) are increasingly used in the reconstruction of large acetabular defects and have mainly been designed using a triflange approach, requiring extensive soft-tissue dissection. The monoflange design, where primary intramedullary fixation within the ilium combined with a monoflange for rotational stability, was anticipated to overcome this obstacle. The aim of this study was to evaluate the design with regard to functional outcome, complications, and acetabular reconstruction.

Methods

Between 2014 and 2023, 79 patients with a mean follow-up of 33 months (SD 22; 9 to 103) were included. Functional outcome was measured using the Harris Hip Score and EuroQol five-dimension questionnaire (EQ-5D). PPR revisions were defined as an endpoint, and subgroups were analyzed to determine risk factors.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 60 - 60
1 Oct 2019
Dennis DA Elkins J Kleeman-Forsthuber LT Miner T Yang CC Jennings JM
Full Access

Introduction. Cutibacterium acnes (C. acnes) is now recognized as a clinical entity in periprosthetic joint infections (PJI) of the shoulder and spine. However, the colonization rate of C. acnes in the adult hip is currently unknown. Therefore, the purpose of this study was to investigate the rate of C. acnes colonization from the skin of healthy subjects from various anatomic locations corresponding to direct anterior and lateral/posterolateral surgical approaches. Methods. 90 patients scheduled for hip or knee surgery were recruited for cultured biopsies. Four 3-mm dermal punch biopsies were collected after administration of anesthesia, but prior to delivery of perioperative antibiotics. Pre-biopsy skin prep consisted of a standardized pre-operative 2% chlorhexidine skin cleanse and an additional 70% isopropyl alcohol mechanical skin scrub immediately prior to biopsy collection. Two culture samples 10-cm apart were collected from a location approximating a standard direct anterior skin incision, and two samples 10-cm apart were collected from a location approximating a lateral skin incision (suitable for a posterior, direct-lateral or anterolateral surgical approach). Samples were cultured for two weeks. Results. 22 of the 90 (24%) patients had a positive culture biopsy, fourteen of which (16% of all patients) were positive for C. acnes. Ten (71%) of the culture positive biopsies for C. acnes were obtained from the anterior location with 50% of those obtained from the most proximal sample site. Conclusions. Approximately 16% of the patients in the study demonstrated positive C. acnes colonization about the hip, the majority of which occurred from an anterior location. C. acnes should be considered in the diagnosis of PJI after THA. Given the high rate of skin colonization, particularly as regards the direct anterior approach to the hip, these results have stimulated consideration for different skin preparations for the THA patient. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 51 - 51
1 Jun 2016
Frew N Nichol T Smith T Stockley I
Full Access

Introduction. Vancomycin is commonly added to acrylic bone cement during revision arthroplasty surgery. Proprietary cement preparations containing vancomycin are available but significantly more expensive. We investigated whether the antibiotic elution and mechanical strength of ‘home-made’ vancomycin containing bone cement was comparable to commercial vancomycin-impregnated cement. Methods. A total of 18 cement discs of constant size, containing either proprietary CopalG+V. ®. ; or ‘home-made’ CopalR+G. ®. with vancomycin added by hand, were made. Each disc contained the same antibiotic quantities (0.5g gentamycin, 2g vancomycin) and was immersed in ammonium acetate buffer in a sealed container. Fluid from each container was sampled at eight time points over a two week period. The concentration of gentamicin and vancomycin in the fluid was analysed using high performance liquid chromatography mass spectrometry. The impact strength of each PMMA cement preparation was measured using a Charpy-type impact tester. Results. Highest peak antibiotic concentrations were observed from the ‘home-made’ vancomycin containing cement, added as in the operating theatre. Overall antibiotic elution was, five-fold (vancomycin) and two-fold (gentamicin), greater from the ‘home-made’ mix compared to commercially mixed cement. However the ‘home-made’ cements showed greater variation in elution kinetics compared to the commercial mix. Use of a vacuum during mixing had no significant effect on antibiotic elution in any of the samples. Impact strength testing showed no significant differences between the groups. Discussion. Our findings suggest the addition of 2g vancomycin powder to gentamicin-impregnated bone cement in theatre, significantly increases elution of both antibiotics, with no significant loss of strength, compared to commercially prepared cement. Conclusion. We have found no significant advantages of expensive off-the-shelf vancomycin-impregnated bone cement and recommend the addition of vancomycin powder by hand when making cement beads and spacers


Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims

Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design.

Methods

Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m2 (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds.