Advertisement for orthosearch.org.uk
Results 1 - 20 of 146
Results per page:
Bone & Joint Open
Vol. 1, Issue 9 | Pages 594 - 604
24 Sep 2020
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases. Results. In total, 327 DHS and 248 hemiarthroplasty procedures were performed by 28 postgraduate year (PGY) 3 to 5 orthopaedic trainees during the 2014 to 2015 surgical training year at nine NHS hospitals in the West Midlands, UK. Overall, 109 PBAs were completed for DHS and 80 for hemiarthroplasty. Expert consensus identified four ‘final product analysis’ (FPA) radiological parameters of technical success for DHS: tip-apex distance (TAD); lag screw position in the femoral head; flushness of the plate against the lateral femoral cortex; and eight-cortex hold of the plate screws. Three parameters were identified for hemiarthroplasty: leg length discrepancy; femoral stem alignment; and femoral offset. Face validity, content validity, and feasibility were excellent. For all measurements, performance was better in the intermediate compared with the novice group, and this was statistically significant for TAD (p < 0.001) and femoral stem alignment (p = 0.023). Concurrent validity was poor when measured against global PBA score. This may be explained by the fact that they are measuring difference facets of competence. Intra-and inter-rater reliability were excellent for TAD, moderate for lag screw position (DHS), and moderate for leg length discrepancy (hemiarthroplasty). Use of a large multicentre dataset suggests good generalizability of the results to other settings. Assessment using FPA was time- and cost-effective compared with PBA. Conclusion. Final product analysis using post-implantation radiographs to measure technical skill in hip fracture surgery is feasible, valid, reliable, and cost-effective. It can complement traditional workplace-based assessment for measuring performance in the real-world operating room . It may have particular utility in competency-based training frameworks and for assessing skill transfer from the simulated to live operating theatre. Cite this article: Bone Joint Open 2020;1-9:594–604


Bone & Joint Open
Vol. 4, Issue 12 | Pages 964 - 969
19 Dec 2023
Berwin JT Duffy SDX Gargan MF Barnes JR

Aims. We assessed the long-term outcomes of a large cohort of patients who have undergone a periacetabular osteotomy (PAO), and sought to validate a patient satisfaction questionnaire for use in a PAO cohort. Methods. All patients who had undergone a PAO from July 1998 to February 2013 were surveyed, with several patient-reported outcome measures (PROMs) and radiological measurements of preoperative acetabular dysplasia and postoperative correction also recorded. Patients were asked to rate their level of satisfaction with their operation in achieving pain relief, restoration of activities of daily living, ability to perform recreational activity, and their overall level of satisfaction with the procedure. Results. A total of 143 PAOs were performed between 1998 and 2013. Of those, 90 postoperative surveys were returned. Only 65 patients (73 hips) had both pre- and postoperative radiographs available for measurement. The mean time to follow-up was 15 years (6.5 to 20). Most patients were female (91%), with a mean age of 26.4 years (14.9 to 48.3) at the time of their surgery. A statistically significant improvement in radiological correction was detected in all hips (p < 0.001). A total of 67 patients (92.3%) remained either very satisfied or satisfied with their PAO. The internal consistency of the patient satisfaction questionnaire, measured using Cronbach’s α, ranged from 0.89 to 0.94 indicating ‘good’ to ‘excellent’ reliability. Conclusion. Outcomes of importance to patients undergoing a PAO include several key domains: pain relief, improve activities of daily living, and improve recreational ability. Our study demonstrates high rates of long-term patient satisfaction in all domains, and found the patient satisfaction questionnaire to be a valid and reliable instrument for use in this cohort. Cite this article: Bone Jt Open 2023;4(12):964–969


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims. To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia. Methods. We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure. Results. A total of 64 patients (76 hips) were included in this study. The median follow-up period was ten years (interquartile range (IQR) five to 14). The median mHHS improved from 67 (IQR 56 to 80) preoperatively to 96 (IQR 85 to 97) at the latest follow-up (p < 0.001). The radiological parameters improved postoperatively (p < 0.001), with the resulting parameters falling within the normal range in 42% to 95% of hips. The survival rate was 95% at ten years and 80% at 15 years. Preoperative Tönnis grade 2 was an independent risk factor for TOA failure. Conclusion. Our findings suggest that TOA with structural bone allografting is a viable surgical option for correcting severely dysplastic acetabulum in adolescents and young adults without advanced osteoarthritis, with favourable mid-term outcomes. Cite this article: Bone Joint J 2023;105-B(7):743–750


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 435 - 441
1 May 2024
Angelomenos V Mohaddes M Kärrholm J Malchau H Shareghi B Itayem R

Aims. Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures. Methods. Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected. Results. Median distal migration (y-axis) at two years for the Refobacin-Optivac system was -0.79 mm (-2.01 to -0.09), for the Refobacin-Optipac system was -0.75 mm (-2.16 to 0.20), and for the Palacos-Optivac system was -1.01 mm (-4.31 to -0.29). No statistically significant differences were found between the groups. Secondary outcomes did not differ statistically between the groups at the two-year follow-up. Conclusion. At two years, we found no significant differences in distal migration or clinical outcomes between the three groups. Our data indicate that Refobacin Bone Cement R and Palacos R + G are comparable in terms of stable fixation and early clinical outcomes. Cite this article: Bone Joint J 2024;106-B(5):435–441


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 783 - 791
1 Aug 2024
Tanaka S Fujii M Kawano S Ueno M Nagamine S Mawatari M

Aims. The aim of this study was to determine the clinical outcomes and factors contributing to failure of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, for advanced osteoarthritis secondary to hip dysplasia. Methods. We reviewed patients with Tönnis grade 2 osteoarthritis secondary to hip dysplasia who underwent TOA between November 1998 and December 2019. Patient demographic details, osteotomy-related complications, and the modified Harris Hip Score (mHHS) were obtained via medical notes review. Radiological indicators of hip dysplasia were assessed using preoperative and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors of failure. Results. This study included 127 patients (137 hips). Median follow-up period was ten years (IQR 6 to 15). The median mHHS improved from 59 (IQR 52 to 70) preoperatively to 90 (IQR 73 to 96) at the latest follow-up (p < 0.001). The survival rate was 90% (95% CI 82 to 95) at ten years, decreasing to 21% (95% CI 7 to 48) at 20 years. Fair joint congruity on preoperative hip abduction radiographs and a decreased postoperative anterior wall index (AWI) were identified as independent risk factors for failure. The survival rate for the 42 hips with good preoperative joint congruity and a postoperative AWI ≥ 0.30 was 100% at ten years, and remained at 83% (95% CI 38 to 98) at 20 years. Conclusion. Although the overall clinical outcomes of TOA in patients with advanced osteoarthritis are suboptimal, favourable results can be achieved in selected cases with good preoperative joint congruity and adequate postoperative anterior acetabular coverage. Cite this article: Bone Joint J 2024;106-B(8):783–791


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 23 - 23
1 Oct 2020
Bechtold D Schwabe M Lawrie C Clohisy JC
Full Access

Introduction. The direct anterior approach (DAA) for total hip arthroplasty (THA) has gained popularity in recent years. Potential advantages over other surgical approaches include less postoperative pain, fewer postoperative precautions, and quicker early recovery. It is most commonly performed in the supine position with traction tables or table mounted bone hooks to facilitate exposure. In this study, we describe a reproducible surgical technique for DAA THA in the lateral decubitus position with use of standard THA equipment and report on our results and learning curve. Methods. A prospectively collected hip repository was queried for all primary THA DAA performed in the lateral position by a single surgeon over a 4-year period from the surgeon's first case utilizing the technique. Retrospective chart review was performed to identify complications and revisions. Modified Harris Hip Score (mHHS) was collected pre-operatively and again at 1-year post-operative. Radiographic parameters including were measured on the 1-year postoperative radiographs. Results. Three hundred forty-one hips were identified in patients over 18 years of age with 337 hips meeting our inclusion/exclusion criteria. A total of 257 hips (76%) had a minimum of 1-year follow-up. 212 of 225 hips (94%) with available mHHS data achieved MCID, defined as mHHS change of > 8. Mean surgical time was 88 ± 16 minutes. Radiographic evaluation demonstrated reproducible results with mean radiographic side to side leg length discrepancy of 2.6 ± 5.9mm and femoral offset difference of 0.2 ± 4.9mm. Among patients with adequate postoperative radiographs, 234 of 243 (96%) had acetabular component positions within Lewinnick's safe zone. 3 hips (0.9%) required revision THA within the first year postoperatively. There were no dislocations and there was no learning curve detected in terms of operative time, blood loss, complication rate or acetabular component position. Discussion. Critics of DAA THA cite its long learning curve with increased risk of complications as an argument against its widespread use. In this study, we have described a safe and efficient technique for performing THA via the DAA in the familiar lateral decubitus with the use of a standard operating table, positioning devices and THA instrumentation. Our results demonstrate excellent acetabular component placement and low rates of complications within the first postoperative year. Conclusion. DAA THA can be performed safely and efficiently in the lateral decubitus position without a specialized table or instrumentation. Surgeon familiarity with patient position and instruments using the technique presented here may be associated with a shorter procedural learning curve


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 598 - 603
1 May 2022
Siljander MP Gausden EB Wooster BM Karczewski D Sierra RJ Trousdale RT Abdel MP

Aims. The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes. Methods. We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m. 2. (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2). Results. Three liners (1.2%) were malseated, including two MDMs (1.4%) and one G7 (0.9%). No clinical consequence was identified from malseating. The five-year survival free of dislocation was 97.1%, including two DM and one intraprosthetic dislocation. The five-year survival free of revision was 95.4%, with seven revisions. The mean Harris Hip Scores increased from 46 (24 to 69) preoperatively to 81 (40 to 100) at two years postoperatively (p < 0.001). Conclusion. The incidence of DM liner malseating after primary THA was low, with no known clinical consequences at mid-term follow-up. Malseating is not exclusive of design, and these findings emphasize the importance of careful evaluation of the liner after impaction to avoid this complication. Cite this article: Bone Joint J 2022;104-B(5):598–603


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1280 - 1288
1 Oct 2018
Grammatopoulos G Gofton W Cochran M Dobransky J Carli A Abdelbary H Gill HS Beaulé PE

Aims. This study aims to: determine the difference in pelvic position that occurs between surgery and radiographic, supine, postoperative assessment; examine how the difference in pelvic position influences subsequent component orientation; and establish whether differences in pelvic position, and thereafter component orientation, exist between total hip arthroplasties (THAs) performed in the supine versus the lateral decubitus positions. Patients and Methods. The intra- and postoperative anteroposterior pelvic radiographs of 321 THAs were included; 167 were performed with the patient supine using the anterior approach and 154 were performed with the patient in the lateral decubitus using the posterior approach. The inclination and anteversion of the acetabular component was measured and the difference (Δ) between the intra- and postoperative radiographs was determined. The target zone was inclination/anteversion of 40°/20° (± 10°). Changes in the tilt, rotation, and obliquity of the pelvis on the intra- and postoperative radiographs were calculated from Δinclination/anteversion using the Levenberg–Marquardt algorithm. Results. The mean postoperative inclination/anteversion was 40° (± 8°)/23° (± 9°) with Δinclination and/or Δanteversion > ± 10° in 74 (21%). Intraoperatively, the pelvis was anteriorly tilted by a mean of 4° (± 10°), internally rotated by a mean of 1° (± 10°) and adducted by a mean of 1° (± 5°). Having Δinclination and/or Δanteversion > ± 10° was associated with a 3.5 odds ratio of having the acetabular component outside the target zone. A greater proportion of THAs that were undertaken with the patient in the lateral decubitus position had Δinclination and/or Δanteversion > ± 10° (35.3%, 54/153) compared with those in the supine position (4.8%, 8/167; p < 0.001). A greater number of acetabular components were within the target zone in THAs undertaken with the patient in the supine position (72%, 120/167), compared with those in the lateral decubitus position (44%, 67/153; p < 0.001). Intraoperatively, the pelvis was more anteriorly tilted (p < 0.001) and more internally rotated (p = 0.04) when the patient was in the lateral decubitus position. Conclusion. The pelvic position is more reliable when the patient is in the supine position, leading to more consistent orientation of the acetabular component. Significant differences in pelvic tilt and rotation are seen with the patient in the lateral decubitus position. Cite this article: Bone Joint J 2018;100-B:1280–8


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1339 - 1344
1 Aug 2021
Jain S Mohrir G Townsend O Lamb JN Palan J Aderinto J Pandit H

Aims. This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Methods. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs. Results. Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement. Conclusion. This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339–1344


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2019
Anderson L Erickson J Peters CL
Full Access

Introduction. Radiographic assessment of acetabular fragment positioning during periacetabular osteotomy (PAO) is of paramount importance. Plain radiographic examination is time and resource intensive. Fluoroscopic based assessment is increasingly utilized but can introduce distortion. Our purpose was to determine the correlation of intraoperative fluoroscopy-based measurements with a fluoroscopic tool that corrects for distortion with postoperative plain-film measurements. Methods. We performed a prospective validation study on 32 PAO's (28 patients) performed by a single academic surgeon. Preoperative standing radiographs, intraoperative fluoroscopic images, and postoperative standing radiographs were evaluated with lateral center edge angle (LCEA), acetabular index (AI), posterior wall sign (PWS), and anterior center edge angle (ACEA). Intraoperative fluoroscopy was adjusted to account for pelvic inclination. The fluoroscopic GRID was utilized in all cases (Phantom MSK Hip Preservation, OrthoGrid LLC, Salt Lake City, UT). Intraoperative fluoroscopic measurements were compared to preoperative and postoperative standing radiographs at 6 weeks using linear regression applied in MINITAB. Results. All pre and post-correction measurements demonstrated excellent agreement within an average difference of 1.2 and 0.9 degrees (deg) respectively (p<0.01). Agreement between post-correction fluoroscopic GRID measurements and 6-week postoperative radiographs was: average difference for LCEA −0.4 deg (range −5 to 8 deg, SD 3.4), −0.9 deg for ACEA (range −16 to 7 deg, SD 5.1), and 0.3 deg for AI (range −8 to 6 deg, SD 3.3) (all p<.01). The PWS agreement was 93%. There was a tendency for fluoroscopic GRID measurements to underestimate acetabular coverage by less than 1 degree. Conclusion. Our study validated the use of a novel intraoperative fluoroscopic tool that accounts for fluoroscopic distortion and permits real-time measurements of PAO fragment correction that correlate accurately with postoperative evaluation. We believe that this tool adds value by giving surgeons reliable quantitative measurements of correction without interfering with surgical work-flow. For any tables or figures, please contact the authors directly


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 872 - 880
1 May 2021
Young PS Macarico DT Silverwood RK Farhan-Alanie OM Mohammed A Periasamy K Nicol A Meek RMD

Aims. Uncemented metal acetabular components show good osseointegration, but material stiffness causes stress shielding and retroacetabular bone loss. Cemented monoblock polyethylene components load more physiologically; however, the cement bone interface can suffer fibrous encapsulation and loosening. It was hypothesized that an uncemented titanium-sintered monoblock polyethylene component may offer the optimum combination of osseointegration and anatomical loading. Methods. A total of 38 patients were prospectively enrolled and received an uncemented monoblock polyethylene acetabular (pressfit) component. This single cohort was then retrospectively compared with previously reported randomized cohorts of cemented monoblock (cemented) and trabecular metal (trabecular) acetabular implants. The primary outcome measure was periprosthetic bone density using dual-energy x-ray absorptiometry over two years. Secondary outcomes included radiological and clinical analysis. Results. Although there were differences in the number of males and females in each group, no significant sex bias was noted (p = 0.080). Furthermore, there was no significant difference in age (p = 0.910) or baseline lumbar bone mineral density (BMD) (p = 0.998) found between any of the groups (pressfit, cemented, or trabecular). The pressfit implant initially behaved like the trabecular component with an immediate fall in BMD in the inferior and medial regions, with preserved BMD laterally, suggesting lateral rim loading. However, the pressfit component subsequently showed a reversal in BMD medially with recovery back towards baseline, and a continued rise in lateral BMD. This would suggest that the pressfit component begins to reload the medial bone over time, more akin to the cemented component. Analysis of postoperative radiographs revealed no pressfit component subsidence or movement up to two years postoperatively (100% interobserver reliability). Medial defects seen immediately postoperatively in five cases had completely resolved by two years in four patients. Conclusion. Initially, the uncemented monoblock component behaved similarly to the rigid trabecular metal component with lateral rim loading; however, over two years this changed to more closely resemble the loading pattern of a cemented polyethylene component with increasing medial pelvic loading. This indicates that the uncemented monoblock acetabular component may result in optimized fixation and preservation of retroacetabular bone stock. Cite this article: Bone Joint J 2021;103-B(5):872–880


Bone & Joint Open
Vol. 3, Issue 6 | Pages 475 - 484
13 Jun 2022
Jang SJ Vigdorchik JM Windsor EW Schwarzkopf R Mayman DJ Sculco PK

Aims. Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. Methods. A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (. Δ. sacral slope(SS). stand-sit. > 30°), or stiff (. ∆. SS. stand-sit. < 10°) spinopelvic mobility contributed to increased error rates. Results. The paired absolute difference between CAS and postoperative imaging measurements was 2.3° (standard deviation (SD) 2.6°) for inclination and 3.1° (SD 4.2°) for anteversion. Using a target zone of 40° (± 10°) (inclination) and 20° (± 10°) (anteversion), postoperative standing radiographs measured 96% of acetabular components within the target zone for both inclination and anteversion. Multiple logistic regression analysis controlling for BMI and sex revealed that hypermobile spinopelvic mobility significantly increased error rates for anteversion (odds ratio (OR) 2.48, p = 0.009) and inclination (OR 2.44, p = 0.016), whereas stiff spinopelvic mobility increased error rates for anteversion (OR 1.97, p = 0.028). There were no dislocations at a minimum three-year follow-up. Conclusion. Despite high reliability in acetabular positioning for inclination in a large patient cohort using an optical CAS system, hypermobile and stiff spinopelvic mobility significantly increased the risk of clinically relevant errors. In patients with abnormal spinopelvic mobility, CAS systems should be adjusted for use to avoid acetabular component misalignment and subsequent risk for long-term dislocation. Cite this article: Bone Jt Open 2022;3(6):475–484


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 47 - 51
1 Jul 2020
Kazarian GS Schloemann DT Barrack TN Lawrie CM Barrack RL

Aims. The aims of this study were to determine the change in the sagittal alignment of the pelvis and the associated impact on acetabular component position at one-year follow-up after total hip arthroplasty (THA). Methods. This study represents the one-year follow-up of a previous short-term study at our institution. Using the patient population from our prior study, the radiological pelvic ratio was assessed in 91 patients undergoing THA, of whom 50 were available for follow-up of at least one year (median 1.5; interquartile range (IQR) 1.1 to 2.0). Anteroposterior radiographs of the pelvis were obtained in the standing position preoperatively and at one year postoperatively. Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Apparent acetabular component position changes were determined from the change in pelvic ratio. A change of at least 5° was considered clinically meaningful. Results. Pelvic ratio decreased (posterior tilt) in 54.0% (27) of cases, did not change significantly in 34.0% (17) of cases, and increased (anterior tilt) in 12.0% (6) of cases when comparing preoperative to one-year postoperative radiographs. This would correspond with 5° to 10° of abduction error in 22.0% of cases and > 10° of error in 6.0%. Likewise, this would correspond with 5° to 10° of version error in 22.0% of cases and > 10° of error in 44.0%. Conclusion. Pelvic sagittal alignment is dynamic and variable after THA, and these changes persist to the one-year postoperative period, altering the orientation of the acetabular component. Surgeons who individualize the acetabular component placement based on preoperative functional radiographs should consider that the rotation of the pelvis (and thus the component version and inclination) changes one year postoperatively. Cite this article: Bone Joint J 2020;102-B(7 Supple B):47–51


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 20 - 26
1 Jul 2020
Romero J Wach A Silberberg S Chiu Y Westrich G Wright TM Padgett DE

Aims. This combined clinical and in vitro study aimed to determine the incidence of liner malseating in modular dual mobility (MDM) constructs in primary total hip arthroplasties (THAs) from a large volume arthroplasty centre, and determine whether malseating increases the potential for fretting and corrosion at the modular metal interface in malseated MDM constructs using a simulated corrosion chamber. Methods. For the clinical arm of the study, observers independently reviewed postoperative radiographs of 551 primary THAs using MDM constructs from a single manufacturer over a three-year period, to identify the incidence of MDM liner-shell malseating. Multivariable logistic regression analysis was performed to identify risk factors including age, sex, body mass index (BMI), cup design, cup size, and the MDM case volume of the surgeon. For the in vitro arm, six pristine MDM implants with cobalt-chrome liners were tested in a simulated corrosion chamber. Three were well-seated and three were malseated with 6° of canting. The liner-shell couples underwent cyclic loading of increasing magnitudes. Fretting current was measured throughout testing and the onset of fretting load was determined by analyzing the increase in average current. Results. The radiological review identified that 32 of 551 MDM liners (5.8%) were malseated. Malseating was noted in all of the three different cup designs. The incidence of malseating was significantly higher in low-volume MDM surgeons than high-volume MDM surgeons (p < 0.001). Pristine well-seated liners showed significantly lower fretting current values at all peak loads greater than 800 N (p < 0.044). Malseated liner-shell couples had lower fretting onset loads at 2,400 N. Conclusion. MDM malseating remains an issue that can occur in at least one in 20 patients at a high-volume arthroplasty centre. The onset of fretting and increased fretting current throughout loading cycles suggests susceptibility to corrosion when this occurs. These results support the hypothesis that malseated liners may be at risk for fretting corrosion. Clinicians should be aware of this phenomenon. Cite this article: Bone Joint J 2020;102-B(7 Supple B):20–26


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 42 - 42
1 Oct 2018
Schloemann DT Edelstein AI Barrack RL
Full Access

Introduction. Malposition of the acetabular component in total hip arthroplasty (THA) is linked to multiple adverse outcomes. Changes in the sagittal plane position of the pelvis, owing both to patient positioning in the operating room and to altered spinopelvic alignment following surgery, potentially contribute to variation in component position. The dynamics of sagittal plane pelvic position before, during, and after THA have not been defined. We measured the differences in pelvic ratio, a measure of sagittal plane pelvic position, between preoperative, intraoperative, and postoperative anteroposterior (AP) radiographs of patients undergoing THA in the lateral decubitus position. Methods. We retrospectively compared the radiographic pelvic ratio among 90 patients undergoing THA. AP radiographs were obtained in the standing position preoperatively and at 6 weeks after surgery; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post anesthesia care unit (PACU). Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Radlink software was used to determine the pelvic ratio on each radiograph. Changes in apparent cup position based on changes in pelvic ratio were calculated using data from the literature, and a change of at least 10 degrees in acetabular component position was defined as clinically meaningful. Analyses were performed using paired t-tests, with p<0.05 defined as significant. Results. 54% of patients had a change in pelvic ratio large enough to alter the apparent acetabular component anteversion by 10 degrees (49% increased and 6% decreased), and 12% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (12% increased and 0% decreased) when the intraoperative AP radiograph was compared to the preoperative AP radiograph. 36% of patients had a change in pelvic ratio from the preoperative radiograph to the 6 week preoperative radiograph large enough to alter the apparent acetabular component anteversion by 10 degrees (5% increased and 31% decreased), and 8% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (6% increased and 1% decreased). Discussion. Changes in the sagittal plane pelvic position between preoperative, intraoperative, and postoperative radiographs occur in a substantial number of patients. These changes correspond to altered functional position of the acetabular component in over half of patients on the intraoperative radiograph and over one third of patients on postoperative radiographs. This variability suggests that intraoperative imaging may be useful for avoiding outliers of component position, and calls into question the feasibility of achieving targeted component positions based on preoperative imaging alone


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 60 - 60
23 Jun 2023
Yasunaga Y Ohshima S Shoji T Adachi N
Full Access

Satisfactory intermediate and long-term results of rotational acetabular osteotomy (RAO) for the treatment of early osteoarthritis secondary to developmental dysplasia of the hip have been reported. The purpose of this study is to examine the 30-year results of RAO. Between 1987 and 1994, we treated 49 patients (55 hips) with RAO for diagnosis of pre- OA or early-stage OA. Of those patients, 35 patients (43 hips) were available at a minimum of 28 years. The follow-up rate was 78.2% and the mean follow-up was 30.5 years. The mean age at the time of surgery was 34 years. Clinical evaluation was performed with the Merle d'Aubigne and Postel rating scale, and radiographic analyses included measurements of the center-edge angle, acetabular roof angle, and head lateralization index on preoperative, postoperative AP radiographs of the pelvis. Postoperative joint congruency was classified into four grades. The radiographic evidence of progression of OA was defined as the minimum joint space less than 2.5mm. The mean preoperative clinical score was 14.0, which improved to a mean of 15.3 at the time of the latest follow-up. The mean center-edge angle improved from 0.6° preoperatively to 34° postoperatively, the mean acetabular roof angle improved from 28.4°preoperatively to 1.0°postoperatively, the mean head lateralization index improved from 0.642 preoperatively to 0.59 postoperatively. Postoperative joint congruency was excellent in 11 hips, good in 29 hips, and fair in 3 hips. Nineteen patients (20 hips) had radiographic OA progression, and 10 patients (11 hips) were converted to THA. Kaplan-Meier survivorship analysis, with radiographic OA progression as the end point, predicted survival of 75.6% at 20 years and 48.8% at 30 years, and with THA conversion as the end point, 90.2% at 20 years and 71.2% at 30 years. The RAO is an effective surgical procedure for symptomatic dysplastic hips of pre- and early-stage OA and could change the natural history of the dysplastic hip


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 45 - 50
1 Jun 2019
Schloemann DT Edelstein AI Barrack RL

Aims. The aims of this study were to determine the change in pelvic sagittal alignment before, during, and after total hip arthroplasty (THA) undertaken with the patient in the lateral decubitus position, and to determine the impact of these changes on acetabular component position. Patients and Methods. We retrospectively compared the radiological pelvic ratio among 91 patients undergoing THA. In total, 41 patients (46%) were female. The mean age was 61.6 years (. sd. 10.7) and the mean body mass index (BMI) was 20.0 kg/m. 2. (. sd. 5.5). Anteroposterior radiographs were obtained: in the standing position preoperatively and at six weeks postoperatively; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post-anaesthesia care unit. Pelvic ratio was defined as the ratio between the vertical distance from the inferior aspect of the sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior aspect of the SI joints. Changes in the apparent component position based on changes in pelvic ratio were determined, with a change of > 5° considered clinically significant. Analyses were performed using Wilcoxon’s signed-rank test, with p < 0.05 considered significant. Results. Intraoperatively, in the lateral decubitus position, the pelvic ratio increased (anterior tilt) in 69.4% of cases, did not change significantly in 20.4%, and decreased (posterior tilt) in 10.2% of cases. When six-week postoperative radiographs were compared with preoperative radiographs, the pelvic ratio decreased in 44.9% of cases, did not change significantly in 42.3%, and increased in 12.8% of cases. This change in alignment correlated with a change in acetabular component version of > 5° in 79.6% of cases intraoperatively and 57.7% of cases at six weeks postoperatively. Conclusion. Changes in pelvic sagittal pelvic position occur throughout THA that, if unaccounted for, introduce errors in acetabular component placement. The use of intraoperative imaging may help the appropriate placement of the acetabular component. Cite this article: Bone Joint J 2019;101-B(6 Supple B):45–50


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 56 - 56
1 Jan 2018
Macheras G Lepetsos P Anastasopoulos P Tzefronis D Galanakos S Poultsides L
Full Access

Porous tantalum is a highly osteoinductive biomaterial, initially introduced in orthopedics in 1997, with a subsequent rapid evolution of orthopedic applications. The use of porous tantalum for the acetabular component in primary total hip arthroplasty (THA) has demonstrated excellent short-term and mid-term results. However, long term data are scarce. The purpose of this prospective study is to report the long-term clinical and radiological outcome following use of an uncemented porous tantalum acetabular component in primary THA with a minimum follow-up of 17.5 years, in a previously studied cohort of patients. We prospectively followed 128 consecutive primary THAs in 140 patients, between November 1997 and June 1999. A press-fit porous tantalum monoblock acetabular component was used in all cases. The presence of initial gaps in the polar region, as sign of incomplete seating of the monoblock cup, was assessed on the immediate postoperative radiographs. All patients were followed clinically and radiographically at 6, 12, and 24 weeks and 12 months and then at 2, 5, 8, 10, and 19 years, for a mean of 18.1 years (range 17.5 – 19 years). Periacetabular dome gap filling, acetabular cup migration and polyethylene wear were assessed by the EBRA digital measurement system, until 2 years postoperatively. Mean age of patients at the time of operation was 60.4 years old (range 24 – 72). Harris hip score, Oxford Hip Score and range of motion (ROM) were dramatically improved in all cases (p < 0.001). In the initial postoperative radiographs, periacetabular dome gaps were observed in the 15% of cases, and were progressively filled within 6 months. In 2 years postoperatively, the mean component migration, as shown in EBRA study, was 0.67 mm. At last follow-up, all cups were radiographically stable with no evidence of migration, gross polyethylene wear, progressive radiolucencies, osteolytic lesions or acetabular fractures. The survivorship with re-operation for any reason as end point was 92.8%, whereas the survivorship for aseptic loosening as an end point was 100%. Upon visual inspection, two removed acetabular components due to recurrent dislocation and infection, respectively, showed extensive bone osseointegration. In our primary THA series, the porous tantalum monoblock cup demonstrated excellent clinical and radiographic outcomes with no failures because of aseptic loosening at a mean follow-up of 18.1 years. Porous tantalum acetabular components showed excellent initial stability, produced less wear debris and revealed a great potential for bone ingrowth. Due to its unique osteoinductive properties and elliptical shape, porous tantalum monoblock cups have demonstrated superior short and long-term survivorship compared to other press fit prostheses in the market


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1654 - 1661
1 Dec 2020
Perelgut ME Polus JS Lanting BA Teeter MG

Aims. The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach. Methods. Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively. Results. Comparing the RSA between the day of surgery baseline exam to two weeks postoperatively, subsidence was significantly lower (mean difference 2.23 mm (SD 0.71), p = 0.023) with collared stems, though these patients had a greater CFR (p = 0.048). There was no difference (p = 0.426) in subsidence between stems from a two-week baseline through to one year postoperatively. There were no clinically relevant differences in PROMs; and there was no difference in the change in activity (p = 0.078) or the change in functional capacity (p = 0.664) between the collared stem group and the collarless stem group at any timepoint. Conclusion. Presence of a collar on the femoral stem resulted in reduced subsidence during the first two postoperative weeks following primary THA using the DA approach. However, the clinical implications are unclear, and larger studies examining patient activity and outcomes are required. Cite this article: Bone Joint J 2020;102-B(12):1654–1661


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 3 - 3
1 Jul 2020
Chan G Aladwan R Hook S Rogers B Ricketts D Stott P
Full Access

Introduction. Dislocated hip hemiarthroplasties (HA) are associated with a 45% revision rate and 40% mortality rate. Implant selection for HA operations vary with no universally accepted implant choice. The WHiTE3 trial suggested older designs such as the Thompson has equitable outcomes to more modern and expensive implants such as the Exeter V40+Unitrax. Our multi-centre consecutive series of NOFs patients treated with HA assesses the impact of surgical and patient factors on dislocation risk. Methods. Medical and radiographic records for patients treated between 1. st. January 2009 and 30. th. September 2017 with a HA at three acute hospitals were reviewed. Implant and dislocation data were recorded. Patient demographics, comorbidities and operation details were extracted from the medical records and NHFD. Patients were excluded if there were no postoperative radiographs or when HA had been performed as a revision procedure. Results. We identified 4305 consecutive patients with 189 excluded. There was no difference in patient characteristics between the hospitals or implant types (p>0.05). Four HA implants were used during the study period; Thompson, Austin-Moore, Furlong and Exeter V40+Unitrax. 63 dislocations were identified (1.5%), median time to dislocation was 24 days. Dislocation rates for Thompson HAs were significantly higher (p=0.004) at 3.7%. No association was demonstrated with cemented versus uncemented, bipolar versus monopolar, fixed versus variable offsets, operating surgeon grade and dislocation rates (p>0.05). Patient factors (preoperative AMTS, postoperative AMTS, preoperative mobility and ASA grade) had no effect on dislocation (p>0.05). Discussion. Our study which is reflective current implant choices, demonstrates that Thompson implants for HA after NOFs have a significantly higher dislocation rates than other common prostheses, and their continued use should be reconsidered. This effect has not been demonstrated in previous studies. Patient, implant construct and surgeon factors had little bearing on the subsequent dislocation rate