Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 141 - 141
1 May 2012
V. P B. F
Full Access

Background. Microdiscectomy involves substantial aggressive excision of disc material from the intervertebral space to prevent reherniation. However, the recent trend is towards conservative disc removal and simple fragment excision (sequestrectomy). Aim. To compare the clinical outcome of microdiscectomy and sequestrectomy. Methods. During the 2-year study period, we performed 196 lumbar microdiscectomies for disc herniation. One hundred and one patients met the inclusion criteria: unilateral single level lumbar disc herniation. Cases suitable for sequestrectomy were based on intraoperative assessment (stable fibrous ring without significant disc bulge; posterior longitudinal ligament perforation of < 5mm). Results. Five patients were lost to follow-up, 72 patients underwent conventional microdiscectomy and 24 patients were suitable for sequestrectomy and included in the final analysis. There was no significant difference in terms of age and pre-operative VAS in both groups (p >0.05, unpaired t test. In the microdiscectomy group, 17/31 patients with motor deficit and 34/66 patients with sensory deficit showed post-operative improvement, but in sequestrectomy group, only 1 of 5 patients with motor deficit and 8 of 13 with sensory deficit recovered but this was not statistically significant (p>0.05, Fisher's exact test). Conclusion. In the sequestrectomy group, patients had significantly better improvement in VAS score. There was no significant difference between either group with regards to reherniation or post-operative neurological deficit. In a selected group of patients with single level lumbar disc herniation, clinical outcome of sequestrectomy is comparable to conventional microdiscectomy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 205 - 205
1 Sep 2012
Kukkar N Beck RT Mai MC Sullivan DN Milbrandt JC Freitag P
Full Access

Purpose. Degenerative changes of the lumbar motion segment often lead to stenosis of the spinal canal or neuroforamen. Axial lumbar interbody fusion (AxiaLIF) is intended to indirectly increase and stabilize foraminal dimensions by restoring disc height in patients with degenerative disc disease, thereby relieving axial and radicular pain. Therefore, this study investigated the effects of AxiaLIF on anterior disc height, posterior disc height, foraminal height and foraminal width as well as to determine the effectiveness of this minimally-invasive technique for indirect decompression and restoration of disc height. Method. Eighty-one patients who underwent a 360 degree lumbar interbody fusion at L4-S1 and L5-S1 with AxiaLIF between November 2008 and May 2010 and satisfied all inclusion criteria were included. The preoperative and three-month postoperative digital radiographs were reviewed and analyzed. Disc heights were measured in the planes of the anterior and posterior surfaces of the adjacent vertebral bodies. Foraminal height was measured as the maximum distance between the inferior margin of the pedicle of the superior vertebra and the superior margin of the pedicle of the inferior vertebra. Foraminal width was measured as the shortest distance between the edge of the superior facet of the caudal vertebra and the posterior edge of inferior endplate of the cranial vertebra. Potential magnification error between pre- and post-operative radiographs was corrected using the anterior vertebral height of L5 vertebra. Results. Our study shows that there is a mean increase of 42.0% in posterior disc height (PDH) at L4-5 and 21.5% in anterior disc height (ADH) at L4-5 and PDH mean increase of 33.6% and 16.3% in ADH at L5-S1 in two-level AxiaLIF cases. Similarly the mean change in foraminal height (FH) was 12.6% at L4-5 and 10.8% at L5-S1 in 2-levels AxiaLIF. The mean change in foraminal width (FW) at L4-L5 was 19.9% and 29.1% at L5-S1 in 2-levels AxiaLIF. In the single level AxiaLIF group, the mean change in PDH was 43.1%, the ADH change was 17.5%, the average change in FH was 14.4%, and mean change in FW was 25.3%. The change is reflected as a percentage of the preoperative value. All changes from preoperative to postoperative values were statistically significant. Conclusion. AxiaLIF appears to be an effective minimally invasive device to increase disc height and neuroforaminal area. Our findings appear equivalent to anterior lumbar interbody fusion and transforaminal lumbar interbody fusion in terms of indirect decompression and increase in disc height. This, in combination with the added benefit of preserving the annulus, anterior longitudinal ligament, and posterior longitudinal ligament, suggests the AxiaLIF is an excellent alternative for this patient population. However, additional follow-up studies are necessary to confirm the long-term ability of the implant to maintain fusion and preserve the improvements in disc and foraminal area


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 28 - 28
1 Oct 2012
Takemoto M Neo M Fujibayashi S Okamoto T Ota E Sakamoto T Nakamura T
Full Access

The accuracy of pedicle screw placement is essential for successful spinal reconstructive surgery. The authors of several previous studies have described the use of image-based navigational templates for pedicle screw placement. These are designed based on a pre-operative computed tomographic (CT) image that fits into a unique position on an individual's bone, and holes are carefully designed to guide the drill or the pedicle probe through a pre-planned trajectory. The current study was conducted to optimise navigational template design and establish its designing method for safe and accurate pedicle screw placement. Thin-section CT scans were obtained from 10 spine surgery patients including 7 patients with adolescent idiopathic scoliosis (AIS) and three with thoracic ossification of the posterior longitudinal ligament (OPLL). The CT image data were transferred to the commercially available image-processing software and were used to reconstruct a three-dimensional (3D) model of the bony structures and plan pedicle screw placement. These data were transferred to the 3D-CAD software for the design of the template. Care was taken in designing the template so that the best intraoperative handling would be achieved by choosing several round contact surfaces on the visualised posterior vertebral bony structure, such as transverse process, spinous process and lamina. These contact surfaces and holes to guide the drill or the pedicle probe were then connected by a curved pipe. STL format files for the bony models with planned pedicle screw holes and individual templates were prepared for rapid prototype fabrication of the physical models. The bony models were made using gypsum-based 3D printer and individual templates were fabricated by a selective laser melting machine using commercially pure titanium powder. Pedicle screw trajectory of the bony model, adaptation and stability of the template on the bony model, and screw hole orientation of the template were evaluated using physical models. Custom-made titanium templates with adequate adaptation and stability in addition to proper orientation of the screw holes were sterilised by autoclave and evaluated during surgery. During segmentation, reproducibility of transverse and spinous processes were inferior to the lamina and considered inadequate to select as contact surfaces. A template design with more bone contact area might enhance the stability of the template on the bone but it is susceptible to intervening soft tissue and geometric inaccuracy of the template. In the bony model evaluation, the stability and adaptation of the templates were sufficient with few small round contact surfaces on each lamina; thus, a large contact surface was not necessary. In clinical patients, proper fit for positioning the template was easily found manually during the operation and 141/142 screws were inserted accurately with 1 insignificant pedicle wall breach in AIS patient. This study provides a useful design concept for the development and introduction of custom-fit navigational template for placing pedicle screws easily and safely