Advertisement for orthosearch.org.uk
Results 1 - 20 of 249
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 63 - 63
1 Nov 2018
Mercer L Mercer D Mercer R Moneim M Benjey L Kamermans E Salas C
Full Access

We hypothesized that the finger extensor mechanism has attachments along the dorsal surface of the entire length of the proximal phalanx and that this anatomy has not been clearly defined. The attachment along the dorsal aspect of the proximal phalanx of the index, middle, index and small fingers was dissected in 20 fresh-frozen cadavers. The lateral bands and attachments along the lateral and medial surface were released to appreciate the attachments along the dorsal aspect. We characterized the ligament attachments as very robust, moderately robust, and minimally robust at the distal, middle, and proximal portions. Three orthopaedic surgeons quantified the attachment, finding that 93% of specimens had tendinous attachments and the most robust attachment found at the most proximal and distal aspects adjacent to the articular cartilage. 87% of the specimens had very robust attachments at the proximal portion of the proximal phalanx. The middle portion of the proximal phalanx had moderate to minimally robust attachments. Greatest variability in attachment was found along the most distal portion of proximal phalanx adjacent to the proximal interphalangeal joint (26% of specimens had moderate to minimal robust attachment; 74% had robust attachments). The attachments along the proximal phalanx were attached on the dorsal half of the proximal phalanx, with no fibrous attachments extending past the lateral bands. In summary, we found tendinous attachment along the proximal phalanx that may assist in finger extension and may extend the digit at the metacarpal phalangeal joint without central band contribution


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 125 - 125
1 Nov 2018
Kurnik C Mercer D Mercer R Salas C Moneim M Kamermans E Benjey L
Full Access

Extensor tendon attachment to the dorsum of the proximal phalanx may fully extend the finger metacarpal phalangeal joint (MPJ). 15 fresh-frozen cadaveric hands were axially loaded in the line of pull to the extensor digitorum comunis of the index, middle, ring and small finger at the level just proximal to the MPJ. We measured force of extension at the MP joint in 3 groups: 1) native specimen, 2) extensor tendon release at the proximal interphalangeal (PIP) joint with release of lumbricals/lateral bands, 3) extensor tendon release at the PIP joint and dorsal proximal phalanx and lumbrical/lateral band release. Degree change of extension was calculated using arctan function with height change of the distal aspect of the proximal phalanx, and the length of the proximal phalanx. We used Student T-test to determine significant decrease in the extension of the phalanges. Extension of all fingers decreased slightly when the extensor tendon were severed at the PIP joint with release of the lateral bands/lumbricals (8deg+/−2deg). After this release, the finger no longer extended. Slight loss of extension was not statistically significant (p >.05) between group 1 and group 2. Groups 1 and 2 were significantly different compared to group 3. In summary, distal extensor tendon transection and release of lateral bands/lumbricals resulted in little change in force and degree of finger extension. The distal insertion of the extensor, released when exposing the PIP joint dorsally, may not need to be repaired to the base of the middle phalanx


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 2 | Pages 226 - 228
1 May 1964
Jones GB

1. Delta phalanx is a rare congenital abnormality not to be confused with other forms of angular deformity of the phalanges. 2. The deformity needs radical treatment by repeated surgery because there is no tendency to spontaneous correction and growth of the phalanx is prevented by the epiphysial deformity


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 8 - 8
1 Mar 2013
Held M Turner Z Laubscher M Solomons M
Full Access

Aim. We aimed to assess the efficacy of conservative management of proximal phalanx fractures in a plaster slab. Methods. 23 consecutive patients with proximal phalanx fractures were included in this prospective study. The fractures were reduced and the position was held with a dorsal slab for three weeks. They were followed up an average of 7 weeks (range 2 to 45) after the injury. Radiographic confirmation of adequate reduction was carried out each week until union. After removal of the plaster, range of motion of the finger and radiological evidence of union, non-union or malunion was documented. Results. In united fractures, an average angulation of 4° (apex volar) was measured (range 0 to 45°). In one case (45°) this was not acceptable. All other cases measured less than 15° of angulation. On the AP radiograph the angulation was on average 2° (range 0 to 8°). On average 1.3 mm of shortening (range 0 to 5mm) were measured. In one case delayed union with rotational deformity of 20° was evident. After removal of the slab mild stiffness was noted in one case at the metacarpophalangeal joint and in two cases at the proximal interphalangeal joint. Conclusion. Most proximal phalanx fractures can be managed conservatively with acceptable results. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 37 - 37
1 Mar 2006
Singh R Kakarala G Persaud I Roberts M Standring S Compson J
Full Access

Suture anchors have changed the practice of repair of tendons in modern Orthopaedics. The purpose of the study was to identify the ideal suture anchor length for anchoring flexor digitorum profundus tendon to the distal phalanx. We dissected 395 distal phalanges from 80 embalmed hands. Phalanges from two little fingers and three thumbs were damaged, hence were excluded from the study. We measured the Anteroposterior and Lateral dimensions at three fixed points on the distal phalanges of all 395 fingers using a Vernier’s Callipers with 0.1mm accuracy. The mean value of the Anteroposterior width of the distal phalanx at the insertion of the FDP was found to be 3.4mm for the little finger; 3.9mm for the ring finger; 4.3mm for the middle finger; 4.0mm for the index finger and 5.0mm for the thumb respectively. The commonly available anchors and drill bits were found to be too long when used for anchoring the flexor digitorum profundus tendon in certain distal phalanges. Our findings may be a reason for poor outcome of FDP repair to distal phalanx using suture anchors. New designs for tissue anchors for distal phalanges may be necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 77 - 80
1 Jan 1984
Neil M Conacher C

The condition known as delta phalanx (or longitudinally bracketed epiphysis) is a rare congenital anomaly first described in 1964. The deformity consists of a triangular bone with an epiphysis running along the shortened side of the phalanx in a proximal to distal direction, making longitudinal growth of the digit impossible. Isolated hallux varus congenitus due to a delta phalanx of the proximal phalanges of both great toes is extremely rare: there have been only three such cases reported, two of which were in one family--the only report of a familial occurrence of this deformity. This present report details the occurrence of isolated bilateral hallux varus congenitus in four members of one family, a father and his three eldest children. All three children show bilateral delta phalanx of the proximal phalanges of both great toes. There are associated thumb nail anomalies, but no suggestion of polydactylism


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 300 - 300
1 May 2006
Trehan R Packham I Mehrotra P Marsh G
Full Access

Malignant change in existing benign enchondroma of phalanx of hand to chondrosarcoma of hand is extremely rare. Books suggest that chondrosarcoma does not arise in small bones of hands and feet although in literature few cases have been reported but not described comprehensively. We report a rare case of chondrosarcoma in distal phalanx of ring finger in a 75- year old healthy female who had cystic lesion for past 25 years with recurrent fractures. Patient came to us with severe pain and tender, hard swelling of distal phalanx of left ring finger. X ray showed pronounced expansion of the terminal phalanx surrounded partially by a shell of bone, with focal spotty calcification with in the lesion. Because of sudden increase in size and pain of swelling, an amputation was performed at distal inter phalangeal joint. Histopathology showed grade II myxoid chondrosarcoma with pre-existing enchondroma. Wound healed nicely. Extensive investigation in form of CT chest and bone scan did not show any metastasis. Five year follow up did not show any local recurrence or distant metastasis. Clinical suspicion should be aroused in an older individual with a previously relatively quiescent lesion that becomes larger and painful. Usually course of the tumour is slow and metastasis to lungs is late. Treatment of choice is disarticulation a joint proximal to lesion. Prognosis is good if metastasis has not occurred. Once diagnosis is made, patient should be investigated to look for any possible metastasis and must be regularly followed up. A literature review and discussion of salient diagnostic and treatment issues is included


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 2 | Pages 347 - 349
1 May 1966
Seymour N

The treatment of juxta-epiphysial fractures of the terminal phalanx is discussed. It is submitted that a simple form of conservative treatment gives the best results


Bone & Joint 360
Vol. 11, Issue 2 | Pages 27 - 30
1 Apr 2022


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 758 - 763
1 Sep 1997
Seno N Hashizume H Inoue H Imatani J Morito Y

We classified fractures of the base of the middle phalanx into five types: 1) single palmar fragment; 2) single dorsal fragment; 3) two main fragments; 4) not involving the articular surface, including epiphyseal separation in children; and 5) all others. Types 1 and 2 were subclassified into avulsion, split and split-depression. Surgery is recommended for unstable type-1 avulsion fractures, type-2 avulsions which may develop buttonhole deformities, and all fractures which displace articular cartilage surfaces. Long-term follow-up showed that surgical treatment which produced good stability and congruity gave good results. These should be the primary aims of treatment


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 108 - 108
1 Feb 2003
Davis TRC Horton TC Hatton M
Full Access

Displaced spiral and oblique fractures of the proximal phalanx are unstable and non-operative treatment frequently results in malunion. Such fractures are therefore treated operatively. No previous study has compared the two common techniques used. Patients with an isolated spiral or oblique fracture of the proximal phalanx were prospectively randomised into two groups. One was treated by closed reduction and Kirschner wire fixation and the second treated by open reduction and lag screw fixation. An independent observer assessed function, pain, movement, grip strength and intrinsic muscle function. X-rays were assessed for malunion. 32 patients entered the study. At follow-up (mean 40 months) there were 15 in the Kirschner wire and 13 in the lag screw group. All returned to their normal employment and 18 described a full functional recovery. There was no significant difference in the functional recovery rates (Fischer exact test p=0. 3) or in pain scores for the two groups (median 0 for both). Radiographs showed similar rates of malunion and there was no statistically significant difference in range of movement or grip strengths. This prospective randomised study has shown no significant difference in outcome for the two techniques. We would recommend that surgeons should choose the method with which they are most familiar and competent, or the technique that utilises the least health care resources


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 273 - 274
1 Mar 2003
Hennrikus WL Cohen MR

Fractures of the neck of the phalanx of the finger are uncommon, but problematic, injuries in children. Displaced fractures may heal with malunion leading to loss of movement or angular deformity. Remodelling of the phalangeal neck is reported to be minimal because of the distance of the fracture from the physis. We report three displaced fractures in two children who presented late. The fractures were treated conservatively and remodelled completely. Both patients regained full movement of the fingers


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 3 | Pages 516 - 519
1 Aug 1972
Pieron AP

1. Rotational deformity of a finger caused by malunion of a phalangeal fracture has been corrected by metacarpal osteotomy. 2. Because of the anatomical arrangement of the metacarpo-phalangeal joint this method gives good control of the distal phalanges. 3. Division through the metacarpal rather than through the phalanx avoids adhesions in the flexor and extensor mechanisms and in the joints of the fingers, allows early mobilisation and is an easier procedure


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 29 - 29
1 Jul 2012
Gregory J Ockendon M Cribb G Cool P Mangham D McClure J
Full Access

Introduction. Enchondromas located in the phalangeal bones may be more cellular than non-digital locations necessitating clinical and radiological correlation to determine diagnosis. Atypical enchondromas have increased cellularity and atypia relative to simple enchondromas but no evidence of permeation. Chondrosarcomas of the phalanges are thought to have a more indolent course than chondrosarcomas in other locations. The aim of the study was to determine the outcome of atypical enchondromas and grade 1 chondrosarcomas of the phalanges treated surgically. Methods. Data was collected prospectively on patients with a cartilage lesion of the phalanges. Typical enchondromas, grade 2 or 3 chondrosarcomas and patients with Ollier's disease were excluded. Results. There were twenty two cases of atypical enchondroma or grade 1 chondrosarcoma. Ten of the patients were female and twelve male with a mean age of 41. There were fourteen atypical enchondromas and eight grade 1 chondrosarcomas. Sixteen of the lesions were in the hand and six were in the foot. Seventeen tumours, including four cases of grade 1 chondrosarcoma, were treated with extended curettage utilising a high speed burr. Five cases were managed by digital amputation as the degree of bone loss precluded retention of the phalanx. At a mean follow up of 30 months there has been one case of local recurrence occurring in an atypical enchondroma of the foot. There have been no cases of local recurrence in the four cases of grade 1 chondrosarcoma treated by curettage. There have been no cases of distant metastasis. All patients remain under long term clinical review. Discussion. There are few published results on the treatment of atypical enchondromata and low-grade chondrosarcomas of the phalanges. In selected cases extended curettage has a low recurrence rate in the treatment of atypical enchondromata and grade 1 chondrosarcomas of the phalanges


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 835 - 837
1 Nov 1987
Citron N Neil M

Eight women had 10 toes treated for hallux rigidus by dorsal wedge osteotomy of the proximal phalanx and were reviewed after an average follow-up of 22 years. Five toes were symptom-free, four others did not restrict walking, and only one had required metatarsophalangeal fusion. We conclude that dorsal wedge osteotomy affords long-lasting benefits for hallux rigidus in the adolescent female


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 381 - 382
1 Jul 2008
Tolat A Reddy R Persad I Compson J Amis A
Full Access

Three methods to reattach avulsed finger flexor tendons to the distal phalanx were compared: a 1.8 mm metal barbed suture anchor, twin 1.3 mm PLA (polylactic acid)absorbable anchors, or a pull-out suture over a button. The suture-anchor interface was tested by pulling the suture at 0, 45, and 90 degrees to the anchor’s axis. The anchors were tested similarly in plastic foam bone substitute. Repairs of transected tendons in cadaveric fingers were loaded cyclically, then to failure. The suture failed prematurely if pulled across the axis of the anchor. Conversely, fixation in bone substitute was stronger when pulling at an angle from the axis. Cyclic loads caused significantly more gap formation in-vitro with twin 1.3 mm absorbable anchors than the other methods; this method was significantly weaker. The 1.8 mm anchor gave similar performance to the pull-out suture over button technique, while the twin 1.3 mm absorbable anchors were weaker and vulnerable to gap formation even with passive motion alone


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 324 - 325
1 May 2009
Varela SR Pareja Esteban JA Fernández-Camacho F Monreal-Redondo D
Full Access

Introduction: During the design of minimally invasive surgeries (MIS) carried out on the third toe of the foot, it is important to know the position of the nutrient foramen in the third metatarsal shaft and/or proximal phalanx to prevent complications such as avascular necrosis or delays in consolidation further to corrective osteotomies carried out to treat certain conditions that affect the third toe in toe-to-hand surgical transposition. Our aim was to determine the location of the main nutrient foramen of the third metatarsal and/or proximal phalange providing a mathematical method to accurately locate it prior to surgery. Materials and methods: We studied 70 third metatarsals and proximal phalanges of the third toe from surgically amputated lower limbs. We established the position of the nutrient foramen in both normal feet and those with forefoot pathological conditions by means of the nutrient index and the distance from the nutrient foramen to the base and the distal cartilage border and, for the third metatarsal, also to the dorsal aspect. Results: The most frequent location of the nutrient foramen was the middle third of the shaft on the plantar aspect of both bones, and in the majority it was the only location. The distance from the nutrient foramina to each base was significantly correlated with their total length and physiology; we provide the corresponding predictive equations with regression lines. Conclusions: We propose predictive equations of the distance of the NF from the base of both bones based on their total lengths. This distance can be determined by somatic measurement or by means of conventional dorso-plantar x-rays without contrast medium


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 6 - 6
1 Apr 2012
Tolat A Reddy R Persad I Compson J Amis A
Full Access

Suture anchors have gained popularity in recent years, particularly owing to their ease of use for attaching soft tissues to bone and improved biomechanical properties. Three methods to reattach avulsed finger flexor tendons to the distal phalanx were biomechanically compared: a 1.8mm metal Mitek barbed suture anchor, twin 1.3mm PLA suture anchors (Microfix), or a pull-out suture over a button. The suture-anchor interface was tested by pulling the suture at 0, 45, 90° to the anchor's axis. The anchors were tested similarly in plastic foam bone substitute. Repairs of transected tendons in cadaveric fingers were loaded cyclically, then to failure. The results were subject to statistical analysis using Student t test (p< 0.001) and 1-way ANOVA (p<0.0001). The suture failed prematurely if pulled across the axis of the anchor. Conversely, fixation in bone substitute was stronger when pulling at an angle from the axis. Cyclic loads caused significantly more gap formation in-vitro with twin 1.3mm anchors than the other methods; this method was significantly weaker. The 1.8mm anchor gave similar performance to the pull-out suture and button, while the twin 1.3mm anchors were weaker and vulnerable to gap formation even with passive motion alone. A suture anchor embedded at between 45 and 90o to the direction of pull gave greater strength than if the pull was in-line. The absorbable 1.3 mm Microfix PLA anchors appeared to be a weak construct, even when twin 1.3 mm anchors were compared to a single metallic 1.8 mm Mitek anchor or the pull-out suture over button technique. All three methods are likely to be satisfactory for reattachment of finger flexor tendons if a low load or non-loading rehabilitation of the hand is planned; however the gap formation on cyclic loading with the Microfix is a concern even if patients are restricted to passive motion


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 581 - 581
1 Oct 2010
Mansha M Miranda S
Full Access

Treatment for the comminuted intra-articular fractures of base of phalanxes remains a challenging problem in hand surgery. The outcomes are commonly associated with pain, stiffness, chronic instability and degenerative arthritis of proximal interphalangeal (PIP) joints. We present our short term results in 12 consecutive patients suffering from these complex fractures treated by closed reduction and application of a dynamic external fixator (Giddins’s frame). The average range of movement achieved was 11–86 degrees and there were no serious complications. We used the construct with slight modification and in our experience this may be helpful to reduce the pin site infection. It is relatively simple, uses widely available equipment (K-wire), and compact thus allows more than one finger to be treated. Early return to work, good pain relief and high level of patient’s satisfaction was achieved. Our short term results were comparable to best previously published results. Based on our experience we recommend this easy technique to treat these complex fractures of IP joints


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 3 | Pages 577 - 581
1 Aug 1966
Byers P Mantle J Salm R

1. Four cases of epidermal cysts of the terminal phalanges of the fingers are reported.

2. The literature is reviewed and the etiological factors discussed.