Aims. The aim of this study was to describe services available to patients with
Aims.
Aims. The objectives of this study were to investigate the patient characteristics and mortality of Vancouver type B
Aims. The aim of this retrospective study was to assess the incidence of early
Aims. To determine mortality risk after first revision total hip arthroplasty (THA) for
Aims. We investigated patient characteristics and outcomes of Vancouver type B periprosthetic fractures treated with femoral component revision and/or osteosynthesis. Patients and Methods. The study utilized data from the Swedish Hip Arthroplasty Register (SHAR) and information from patient records. We included all primary total hip arthroplasties (THAs) performed in Sweden since 1979, and undergoing further surgery due to Vancouver type B
Aims. The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B
Aims. Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes. Methods. A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications. Results. Over a mean follow-up period of 10.6 years, the mean stem subsidence was similar between groups, with a mean of -1.20 mm (95% confidence interval (CI) -2.28 to -0.12) in the broaching group and a mean of -0.73 mm (95% CI -1.65 to 0.20) in the compaction group (p = 0.07). The long-term migration patterns of all stems were similar. The clinical and radiological outcomes were similar between groups. There were two intraoperative fractures in the compaction group that were fixed with cable wire and healed without complications. No stems were revised. Conclusion. Similar stem subsidence and radiological and clinical outcomes were identified after the use of compaction and broaching techniques of the femur at long-term follow-up. Only the compaction group had intraoperative
Aims. We compared implant and patient survival following intraoperative
Aims. This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative
Aims. Vancouver type B
Aims. The aim of this study was to estimate the 90-day risk of revision for
Aims.
Aims. This study evaluates risk factors influencing fracture characteristics for postoperative
Known risk factors for early
Aims. We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2
The recruitment drive, investment and collaboration within Betsi Cadwaladr University Health Board (BCUHB) sites providing specialist lower limb arthroplasty and trauma service has evolved over last few years with aims to improve patient care and reduce reliance on tertiary referral centres. Through our service-evaluation project, we reviewed the results of treatment provided for
Objective: The number of hip prostheses replacement surgeries particularly in elder people with osteoporosis, has been increasing every year; given this scenario, treatment of postoperative