Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 395 - 395
1 Sep 2012
Sánchez Ruas JJ Burgos Flores J Aranda Romero F Del Olmo Hernández T De Blas G Barrios C Hevia E Regidor I Correa Gorospe C Ruíz Ibán M Díaz Heredia J López Mondéjar J Berrendero L
Full Access

Introduction. A new triggered electromyography test for detection of stimulus diffusion to intercostal muscles of the contralateral side during thoracic pedicle screw placement was evaluated. Experimental research was carried out in order to determine if, using this test, neural contact at different aspects of the spinal cord and nerve roots could be discriminated. Methods. Nine industrial pigs (60–75 kg) had 108 pedicle screws placed bilaterally in the thoracic spine (T8–T13). Neural structures were stimulated under direct vision at different anatomic locations from T9 to T12. Recording electrodes were placed over the right and left intercostal muscles. Increasing intensity of the stimulus was applied until muscle response was detected at the contralateral side (diffusion phenomenon). After this first experiment, the thoracic spine was instrumented. Screws were placed in the pedicle in two different positions, the anatomic intrapedicular location and with purposeful contact with the neural elements. Results. Response thresholds to direct stimulation of nerve root at different points were significantly lower than those obtained by stimulation of the dorsal aspect of the spinal cord (0.44±0.22 mA vs 1.38±0.71 mA). However, a 24-fold stimulation intensity (6.50±0.29 mA) was necessary to obtain diffusion of the EMG response to the opposite left side if the right nerve root was stimulated. Only a 2-fold increment (3.17±0.93 mA) was able to elicit diffusion of EMG responses to the contralateral side when stimulation was applied to the dorsal aspect of the spinal cord. Contralateral EMG responses after high increases of stimulation thresholds indicated nerve root contact. Diffusion phenomenon after low threshold increments reflected medullar contact. Electromyography recordings after triggered stimulation of the screws showed that only screws in contact with the spinal cord had significantly lower responses (2.72±1.48 mA). Conclusion. Stimulus-triggered EMG could only discriminate screws with violation of the medial pedicle wall if they were contact with neural tissues. Recording EMG-potentials at the contralateral paraspinal muscles (stimulus diffusion phenomenon) proved to be a reliable method to discriminate which of the neural structures was at risk


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims

We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy.

Materials and Methods

Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers.