The
Two hundred and thirty six posterior stabilized total knee arthroplasties were performed consecutively. Twenty seven
The clunk syndrome is a rare complication of the posterostabilized total knee arthroplasties. In the literature, there is a lot of aetiologies described concluding to a multifactorial disease. The aim of our study is to analyse the risk factors described in the literature in a serie of clunk syndrome occurring in three different prosthesis. We retrospectively analyzed all our cases of clunk syndrome. We compared radiographic values before and after the intervention: the Insall-Salvati ratio, the joint line modification, the thickness of the patella and position of the tibial tray. We compared the appearance of the clunk in three different types of new generation prosthesis: Scopio NRG (Stryker), Legacy (Zimmer) and Sigma (DePuy). The bone scan was done preoperatively to confirm diagnosis. There are four cases of clunk in each group of prosthesis which represents an mean incidence of 0,5 %. All the clunks occurred in female patients. There is three bilateral cases and one homolateral recurrence. We find no difference in the preoperative values compared to the postoperative status. There is no difference between the three groups. The bone scan was done in eight cases and returned positive in seven cases. All our cases of clunk syndrome occurred in female patients which is our first risk factor. Doing a clunk syndrome on one side is a great risk factor of doing a clunk on the other side if implanted. The diagnosis of the syndrome is mostly clinical but the bone scan is frequently positive. The
Aims. Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs. Methods. A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m. 2. (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19). Results. The ten-year survivorship free from revision was 91% (95% confidence interval (CI) 81 to 100) in affected and 84% (95% CI 68 to 100) in unaffected limbs. There were six revisions in affected limbs: three for periprosthetic femoral fractures and one each for periprosthetic joint infection (PJI),
Objective. We performed total knee arthroplasty (TKA) without patella resurfacing in patients with osteoarthritis (OA) of the knee. The purpose of the present study was to evaluate the clinical results and the appropriateness TKA without patella resurfacing. Methods. A total of 61 patients (61 affected knees) who had undergone a Low Contact Stress mobile − bearing knee arthroplasty (LCS− TKA) (Depuy, Warsaw, IN. USA) 10 years or more before the present study were enrolled. The LCS− TKAs did not include patella resurfacing. The patients' mean age was 77.7 ± 6.1 years (range: 59−94 years). The mean follow-up period was 121 ± 2.4 months (range: 120−129 months). The clinical evaluation used the scoring system for OA of the knees issued by the Japanese Orthopaedic Association (JOA score). We defined patellofemoral (PF) pain, crepitation,
From October 2005 to March 2014, we performed 46 arthroscopic surgeries for painful knee after knee arthroplasty. We excluded 16 cases for this study such as, unicompartmental knee arthroplasty, infection,
Introduction. Following total knee arthroplasty (TKA), some patients show patella baja. It is possible that patella baja after posterior stabilized (PS)-type TKA causes the
Achieving deep flexion of knee after total knee arthroplasty (TKA) is particularly desirable in some Asian and Middle Eastern who have daily or religious customs typically use full knee flexion. After TKA, some patients complained about anterior knee pain during deep knee flexion. We evaluated the efficacy of arthroscopic fat pad resection in a series of patients suffering from anterior knee pain associated with high flexion achievement after TKA. The efficacy of fat pad resection via arthroscopy for treating anterior knee pain associated with high flexion angle (average = 133.1°) was evaluated in eight knees of eight patients among 207 knees performed between 1996 and 1999. The mean age of patients was 71.1 years when the primary TKA was performed. All implatants were posterior stabilized type (IB-II, Nexgen PS and LPS). The symptom of anterior knee pain during deep knee flexion developed within one year after TKA in all cases. In addition to pain in eight knees, two patients have crepitation as the knee was flexed and extended and three patients had hydrarthrosis. Impingement and fibrosis of fat pad were confirmed, and fibrous structures were removed by arthroscopy. Before arthroscopy, the symptom obviously subsided after injection of local anesthesia into infrapatellar fat pad.
Aim: There have been increasingly publications about the complicated disease of patello-femoral joints after total knee arthroplasty (TKA). We have treated soft tissue impingement under the patella after TKA by arthroscopic surgery and investigated the findings and efficacy of the treatment. Materials and Methods: 6 patients and 8 knees which showed soft tissue impingement of patello-femoral joints after TKA. Surgical arthroscopy was performed and impinging soft tissues were classified and the efficacy of arthroscopic treatment were evaluated. Results: We classified the patients with soft tissue impingement under the patella into three groups: (I)
The Columbus is a relatively new implant with no published medium or long term follow-up. Its extensive use within our department led to this study to review the five-year clinical outcomesof patients who had a navigated Columbus primary total knee arthroplasty (TKA) implanted between March 2005 and December 2006. Case notes, departmental and hospital databases and PACS were used to identify patients and collect routine five-year review data. Information Services Division was approached for all cases of re-admission and associated complications anywhere in Scotland. 219 (90 male, 116 left) patients were identified. Mean age was 69 years (48–89) and mean BMI 32.2 (SD 5.8). Of the 219 patients operated on, twenty-one had a complication; ten still had intermittent mild to moderate pain, three had wound problems, one had a washout, one had DVT/PE within ninety days and one was diagnosed with
Avoidance of extensor mechanism complications is best obtained by using components with an appropriately designed femoral trochlea and patellar component and where internally rotated components are avoided. Residual valgus deformity may also lead to patellar dislocation or more subtle subluxations, which may manifest as pain along the medial patellar retinaculum. Because rotational abnormalities are difficult to detect on plain x-ray, CT scans are a useful way to diagnose this problem. Peripatellar crepitation may cause symptoms and can be avoided by aggressive peripatellar synovectomy at the time of surgery. In its most severe form, the
Background. We have performed total knee arthroplasties for valgus and varus in the knees of one person and investigate the clinical characteristics of these patients and the relationship between the kind of deformity and postoperative result. Methods. From March 2002 to February 2010, 25 patients who had simultaneous varus and valgus knee deformities underwent total knee arthroplasties and followed more than 12 months were included. The average age was 66.9 years and the average follow-up period was 61.1 months. Follow-up imaging assessments were taken and clinical outcome were evaluated using HSS score at last follow-up. Results. 11 cases had more pain in varus knee and 8 cases had more pain in valgus knee preoperatively. In 11 cases, degenerative scoliosis were associated with the knee deformity and among the cases, 10 cases had valgus deformities in concave side of scoliosis. In three cases, hip deformities were noted in ipsilateral side of the valgus deformity. One case showed both hip deformities with ankylosing spondylitis. Preoperative mean valgus angle was 11.4 degree and varus angle was 7.5 degree. Postoperative valgus and varus angle improved to 6.3 and −5.7 degree. HSS score improved from 64.3 to 84.7 point in valgus deformities and from 62.1 to 85.1 point in varus deformities. Postoperative
There is little information regarding the risk of a patient developing prosthetic joint infection (PJI) after primary total knee arthroplasty (TKA) when the patient has previously experienced PJI of a TKA or total hip arthroplasty (THA) in another joint. The goal of this study was to compare the risk of PJI of primary TKA in this patient population against matched controls. We retrospectively reviewed 95 patients (102 primary TKAs) treated between 2000 and 2014 with a history of PJI in another TKA or THA. A total of 50 patients (53%) were female. Mean age was 69 years (45 to 88) with a mean body mass index (BMI) of 36 kg/m2 (22 to 59). In total, 27% of patients were on chronic antibiotic suppression. Mean follow-up was six years (2 to 16). We 1:3 matched these (for age, sex, BMI, and surgical year) to 306 primary TKAs performed in 306 patients with a THA or TKA of another joint without a subsequent PJI. Competing risk with death was used for statistical analysis. Multivariate analysis was followed to evaluate risk factors for PJI in the study cohort.Aims
Patients and Methods
The management of patients with a painful total knee replacement requires careful assessment and a stepwise approach in order to diagnose the underlying pathology accurately. The management should include a multidisciplinary approach to the patient’s pain as well as addressing the underlying aetiology. Pain should be treated with appropriate analgesia, according to the analgesic ladder of the World Health Organisation. Special measures should be taken to identify and to treat any neuropathic pain. There are a number of intrinsic and extrinsic causes of a painful knee replacement which should be identified and treated early. Patients with unexplained pain and without any recognised pathology should be treated conservatively since they may improve over a period of time and rarely do so after a revision operation.
Locking after total knee replacement is uncommon and is generally caused by the formation of fibrous tissue around the patella. We report an unusual cause of locking resulting from intermittent occlusion of the popliteal artery, which was tethered to cement at the posterior aspect of the tibial component.
One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines. The Total Condylar prosthesis had the lowest conformity with the native patella (mean 8.58°; 0.14° to 29.9°) and with its own patellar component (mean 11.36°; 0.55° to 39.19°). In the other four prostheses, the conformity was better (mean 2.25°; 0.02° to 10.52°) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity (mean 6.51°; 0.07° to 9.89°) than the Miller-Galante II prosthesis (mean 11.20°; 5.80° to 16.72°) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid (mean 3.57°; 1.40° to 4.56°) or high angles of flexion (mean 4.54°; 0.91° to 9.39°), respectively. The Low Contact Stress femoral component had the best conformity with the native patella (mean 2.39°; 0.04° to 4.56°). There was no significant difference (p >
0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion. The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation.
Evaluation of patients with painful total knee replacement requires a thorough clinical examination and relevant investigations in order to reach a diagnosis. Awareness of the common and uncommon problems leading to painful total knee replacement is useful in the diagnostic approach. This review article aims to act as a guide to the evaluation of patients with painful total knee replacement.