Bone & Joint Research
Vol. 12, Issue 3 | Pages 155 - 164
1 Mar 2023
McCarty CP Nazif MA Sangiorgio SN Ebramzadeh E Park S

Aims

Taper corrosion has been widely reported to be problematic for modular total hip arthroplasty implants. A simple and systematic method to evaluate taper damage with sufficient resolution is needed. We introduce a semiquantitative grading system for modular femoral tapers to characterize taper corrosion damage.

Methods

After examining a unique collection of retrieved cobalt-chromium (CoCr) taper sleeves (n = 465) using the widely-used Goldberg system, we developed an expanded six-point visual grading system intended to characterize the severity, visible material loss, and absence of direct component contact due to corrosion. Female taper sleeve damage was evaluated by three blinded observers using the Goldberg scoring system and the expanded system. A subset (n = 85) was then re-evaluated following destructive cleaning, using both scoring systems. Material loss for this subset was quantified using metrology and correlated with both scoring systems.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 30 - 30
7 Aug 2024
Preece S Smith J Brookes N Ghio D
Full Access

Purpose. Cognitive Muscular Therapy (CMT) is a new treatment for low back pain which integrates psychological techniques for pain management alongside training to improve postural control. Rather than focus on postural alignment or strength, CMT aims to improve the regulation of postural tone (low-level activity which supports the body against gravity). This is achieved by teaching patients an awareness of compensatory paraspinal activation, which can be triggered by overactivity of the abdominal muscles. The aim of this study was to understand whether CMT could reduce symptoms associated with low back pain and improve paraspinal muscle activation. Methods and results. Fifteen patients with chronic low back pain received seven weekly sessions of CMT from a physiotherapist. Clinical data was captured at baseline and two weeks after the intervention using the Roland-Morris questionnaire and the pain catastrophising scale. Activation of the erector spinae muscle during walking was also measured at baseline and after the final intervention session. Change data were analysed using paired t-tests. There was a 75% reduction (p<0.001) in the Roland-Morris score from a mean (SD) of 9.3(2.9) to 2.3(2.6), along with a 78% reduction in pain catastrophising (p<0.002) from 16.6(13) to 3.7(4.8). Activation of the contralateral erector spinae muscles reduced by 30% (p<0.01) during the contralateral swing phase of walking. Conclusion. In this small sample, CMT delivered large clinical improvements and reduced activation of the low back muscles during walking. Larger randomised trials are now required to confirm whether CMT could outperform existing physiotherapy treatments for chronic back pain. Conflict of interest. No conflicts of interest. Source of funding. University of Salford


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 32 - 32
4 Apr 2023
Pareatumbee P Yew A Meng Chou S Koh J Zainul-Abidin S Howe T Tan M
Full Access

To analyse bone stresses in humerus-megaprosthesis construct in response to axial loading under varying implant lengths in proximal humeral replacement following tumour excision. CT scans of 10 cadaveric humeri were processed in 3D Slicer to obtain three-dimensional (3D) models of the cortical and cancellous bone. Megaprostheses of varying body lengths (L) were modelled in FreeCAD to obtain the 3D geometry. Four FE models: group A consisting of intact bone; groups B (L=40mm), C (L=100mm) and D (L=120mm) comprising of humerus-megaprosthesis constructs were created. Isotropic linear elastic behaviour was assigned for all materials. A tensile load of 200N was applied to the elbow joint surface with the glenohumeral joint fixed with fully bonded contact interfaces. Static analysis was performed in Abaqus. The bone was divided at every 5% bone length beginning distally. Statistical analysis was performed on maximum von Mises stresses in cortical and cancellous bone across each slice using one-way ANOVA (0-45% bone length) and paired t-tests (45-70% bone length). To quantify extent of stress shielding, average percentage change in stress from intact bone was also computed. Maximum stress was seen to occur distally and anteriorly above the coronoid fossa. Results indicated statistically significant differences between intact state and shorter megaprostheses relative to longer megaprostheses and proximally between intact and implanted bones. Varying levels of stress shielding were recorded across multiple slices for all megaprosthesis lengths. The degree of stress shielding increased with implant lengthening being 2-4 times in C and D compared to B. Axial loading of the humerus can occur with direct loading on outstretched upper limbs or indirectly through the elbow. Resultant stress shielding effect predicted in longer megaprosthesis models may become clinically relevant in repetitive axial loading during activities of daily living. It is recommended to use shorter megaprosthesis to prevent failure


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 12 - 12
8 May 2024
Miller D Stephen J Calder J el Daou H
Full Access

Background. Lateral ankle instability is a common problem, but the precise role of the lateral ankle structures has not been accurately investigated. This study aimed to accurately investigate lateral ankle complex stability for the first time using a novel robotic testing platform. Method. A six degrees of freedom robot manipulator and a universal force/torque sensor were used to test 10 foot and ankle specimens. The system automatically defined the path of unloaded plantar/dorsi flexion. At four flexion angles: 20° dorsiflexion, neutral flexion, 20° and 40° of plantarflexion; anterior-posterior (90N), internal-external (5Nm) and inversion-eversion (8Nm) laxity were tested. The motion of the intact ankle was recorded first and then replayed following transection of the lateral retinaculum, Anterior Talofibular Ligament (ATFL) and Calcaneofibular Ligament (CFL). The decrease in force/torque reflected the contribution of the structure to restraining laxity. Data were analysed using repeated measures of variance and paired t-tests. Results. The ATFL was the primary restraint to anterior drawer (P< 0.01) and the CFL the primary restraint to inversion throughout range (P< 0.04), but with increased plantarflexion the ATFL's contribution increased. The ATFL had a significant role in resisting tibial external rotation, particularly at higher levels of plantarflexion, contributing 63% at 40° (P< 0.01). The CFL provided the greatest resistance to external tibial rotation, 22% at 40° plantarflexion (P< 0.01). The extensor retinaculum and skin did not offer significant restraint in any direction tested. Conclusion. This study shows accurately for the first time the significant role the ATFL and CFL have in rotational ankle stability. This significant loss in rotational stability may have implications in the aetiology of osteophyte formation and early degenerative changes in patients with chronic ankle instability. This is the first time the role of the lateral ankle complex has been quantified using a robotic testing platform


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 93 - 93
1 Dec 2022
Gazendam A Schneider P Busse J Giglio V Bhandari M Ghert M
Full Access

Functional outcomes are important for patients with bone tumors undergoing lower extremity endoprosthetic reconstruction; however, there is limited empirical evidence evaluating function longitudinally. The objective of this study was to determine the changes in function over time in patients undergoing endoprosthetic reconstructions of the proximal femur, distal femur and proximal tibia. We conducted a secondary analysis of functional outcome data from the Prophylactic Antibiotic Regimens in Tumor Surgery (PARITY) trial. Patient function was assessed with the Musculoskeletal Tumor Society Score 93 (MSTS) and the Toronto Extremity Salvage Score (TESS), which were administered preoperatively and at 3, 6 and 12 months postoperatively. Both instruments are scored from 0-100, with higher scores indicated greater function. Mean functional scores were evaluated over time and we explored for differences among patients undergoing proximal femur reconstructions (PFR), distal femur reconstructions (DFR) and proximal tibia reconstructions (PTR). The patient-importance of statistically significant differences in function was evaluated utilizing the minimally important difference (MID) of 12 for the MSTS and 11 for the TESS. We explored for differences in change scores between each time interval with paired t-tests. Differences based on endoprosthetic reconstruction undertaken were evaluated by analysis of variance and post-hoc comparisons using the Tukey test. A total of 573 patients were included. The overall mean MSTS and TESS scores were 77.1(SD±21) and 80.2(SD±20) respectively at 1-year post-surgery, demonstrating approximately a 20-point improvement from baseline for both instruments. When evaluating change scores over time by type of reconstruction, PFR patients experienced significant functional improvement during the 3-6 and 6-12 month follow-up intervals, DFR patients demonstrated significant improvements in function at each follow-up interval, and PTR patients reported a significant decrease in function from baseline to 3 months, and subsequent improvements during the 3-6 and 6-12 month intervals. On average, patients undergoing endoprosthetic reconstruction of the lower extremity experience important improvements in function from baseline within the first year. Patterns of functional recovery varied significantly based on type of reconstruction performed. The results of this study will inform both clinicians and patients about the expected rehabilitation course and functional outcomes following endoprosthetic reconstruction of the lower extremity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 35 - 35
17 Nov 2023
Timme B Biant L McNicholas M Tawy G
Full Access

Abstract. Objectives. Little is known about the impact of cartilage defects on knee joint biomechanics. This investigation aimed to determine the gait characteristics of patients with symptomatic articular cartilage lesions of the knee. Methods. Gait analyses were performed at the Regional North-West Joint Preservation Centre. Anthropometric measurements were obtained, then 16 retroreflective markers representing the Plug-in-Gait biomechanical model were placed on pre-defined anatomical landmarks. Participants walked for two minutes at a self-selected speed on a treadmill on a level surface, then for 2 minutes downhill. A 15-camera motion-capture system recorded the data. Knee kinematics were exported into Matlab to calculate the average kinematics and spatiotemporal parameters per patient across 20 gait cycles. Depending on the normality of the data, paired t-tests or Wilcoxon ranked tests were performed to compare both knees (α = 0.05). Results. 20 patients participated; one of whom has bilateral cartilage defects. All 20 data sets were analysed for level walking; 18 were analysed for downhill walking. On a level surface, patients walked at an average speed of 3.1±0.8km/h with a cadence of 65.5±15.3 steps/minute. Patients also exhibited equal step lengths (0.470±0.072m vs 0.471±0.070m: p=0.806). Downhill, the average walking speed was 2.85±0.5km/h with a cadence of 78.8±23.1 steps/minute and step lengths were comparable (0.416±0.09m vs 0.420±0.079m: p=0.498). During level walking, maximum flexion achieved during swing did not differ between knees (54.3±8.6° vs 55.5±11.0°:p=0.549). Neither did maximal extension achieved at heel strike (3.1±5.7° vs 5.4±4.7°:p=0.135). On average, both knees remained in adduction throughout the gait cycle, with the degree of adduction greater in flexion in the operative knee. However, differences in maximal adduction were not significant (22.4±12.4° vs 18.7±11.0°:p=0.307). Maximal internal-external rotation patterns were comparable in stance (0.9±7.7° vs 3.5±9.8°: p=0.322) and swing (7.7±10.9° vs 9.8±8.3°:p=0.384). During downhill walking, maximum flexion also did not differ between operative and contralateral knees (55.38±10.6° vs 55.12±11.5°:p=0.862), nor did maximum extension at heel strike (1.32±6.5° vs 2.73±4.5°:p=0.292). No significant difference was found between maximum adduction of both knees (15.87±11.0° vs 16.78±12.0°:p=0.767). In stance, differences in maximum internal-external rotation between knees were not significant (5.39±10.7° vs 6.10±11.8°:p=0.836), nor were they significant in swing (7.69±13.3° vs 7.54±8.81°:p=0.963). Conclusions. Knee kinematics during level and downhill walking were symmetrical in patients with a cartilage defect of the knee, but an increased adduction during flexion in the operative knee may lead to pathological loading across the medial compartment of the knee during high flexion activities. Future work will investigate this further and compare the data to a healthy young population. We will also objectively assess the functional outcome of this joint preservation surgery to monitor its success. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 8 - 8
1 Aug 2021
Clewes P Lohan C Stevenson H Coates G Wood R Blackburn S Tritton T Knaggs R Dickson A Walsh D
Full Access

Due to limitations of existing pharmacological therapies for the management of chronic pain in osteoarthritis (OA), surgical interventions remain a major component of current standard of care, with total joint replacements (TJRs) considered for people who have not responded adequately to conservative treatment. This study aimed to quantify the economic burden of moderate-to-severe chronic pain in patients with OA in England prior to TJR. A retrospective, longitudinal cohort design was employed using Clinical Practice Research Datalink GOLD primary care data linked to Hospital Episode Statistics secondary care data in England. Patients (age ≥18 years) with an existing OA diagnosis of any anatomical site (Read/ICD-10) were indexed (Dec-2009 to Nov-2017) on a moderate-to-severe pain event (which included TJR) occurring within an episode of chronic pain. 5-year TJR rates from indexing were assessed via Kaplan-Meier estimates. All-cause healthcare resource utilisation and direct medical costs were evaluated in the 1–12 and 13–24 months prior to the first TJR experienced after index. Statistical significance was assessed via paired t-tests. The study cohort comprised 5,931 eligible patients (57.9% aged ≥65 years, 59.2% female). 2,176 (36.7%) underwent TJR (knee: 54.4%; hip: 42.8%; other: 2.8%). The 5-year TJR rate was 45.4% (knee: 24.3%; hip: 17.5%; other: 6.8%). Patients experienced more general practitioner consultations in 1–12 months pre-TJR compared with 13–24 months pre-TJR (means: 12.13 vs. 9.61; p<0.0001), more outpatient visits (6.68 vs. 3.77; p<0.0001), more hospitalisations (0.74 vs. 0.62; p=0.0032), and more emergency department visits (0.29 vs. 0.25, p=0.0190). Total time (days) spent as an inpatient was higher in 1–12 months pre-TJR (1.86 vs. 1.07; p<0.0001). Mean total per-patient cost pre-TJR increased from £1,771 (13–24 months) to £2,621 (1–12 months) (p<0.0001). Resource-use and costs incurred were substantially greater in the 12 months immediately prior to TJR, compared with 13–24 months prior. Reasons for increased healthcare and economic burden in the pre-TJR period deserve further exploration as potential targets for efforts to improve patient experience and efficiency of care


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 108 - 108
1 Sep 2012
Meccia B Spencer E Zingde S Sharma A Lesko F Mahfouz M Komistek R
Full Access

INTRODUCTION. Total shoulder arthroplasty (TSA) implants are used to restore function to individuals whose shoulder motions are impaired by osteoarthritis. To improve TSA implant designs, it is crucial to understand the kinematics of healthy, osteoarthritic (OA), and post-TSA shoulders. Hence, this study will determine in vivo kinematic trends of the glenohumeral joints of healthy, OA, and post-TSA shoulders. Methods. In vivo shoulder kinematics were determined pre and post-operatively for five unilateral TSA subjects with one healthy and a contralateral OA glenohumeral joint. Fluoroscopic examinations were performed for all three shoulder categories (healthy, OA, and post-TSA) for each subject shoulder abduction and external rotation. Then, three-dimensional (3D) models of the left and right scapula and humerus were constructed using CT scans. For post-operative shoulders, 3D computer-aided design models of the implants were obtained. Next, the 3D glenohumeral joint kinematics were determined using a previously published 3D to 2D registration technique. After determining kinematics, relative Euler rotation angles between the humerus and scapula were calculated in MATLAB® to determine range of motion (ROM) and kinematic profiles for all three shoulder categories. The ROMs for each category were compared using paired t-tests for each exercise. Also, the location of the contact point of the humerus on the glenoid was found. This allowed the vertical translation from the most superior to most inferior contact point (SI contact range) to be calculated as well as the horizontal translation from the most anterior to most posterior contact point (AP contact range). The SI and AP contact ranges for all shoulder categories were compared using paired t-tests for each exercise. Results. Abduction. According to preliminary results, the averages range of abduction for healthy, OA, and post-TSA shoulders was 51.5 °, 19.4°, and 56.7°, respectively. The average SI contact range of abduction for healthy, OA, and post-TSA shoulders was 14.1 mm, 16.4 mm, and 14.1 mm, respectively while the AP contact range was 10.0, 14., and 14.3, respectively. The ranges of abduction between healthy and OA and between OA and post-TSA shoulders, and the AP contact range for healthy and OA shoulders displayed statistically significant differences at the α=0.05 level. External Rotation. The averages range of External Rotation for healthy, OA, and post-TSA shoulders was 63.6°, 31.1°, and 44.5°, respectively. The averages SI contact range of External Rotation for healthy, OA, and post-TSA shoulders was 20.7, 12.7, and 15.9 mm, respectively while the averages AP contact range was 8.5,12.9 mm, and 13.8 mm, respectively. The ranges of abduction for healthy and OA as well as AP contact range for healthy and OA shoulders were statistically different at the α=0.05 level. Conclusions. This study's preliminary results indicate that healthy, OA, and post-TSA shoulders show statistically significant difference in kinematic trends including ROM and contact point translation. These differences may result from the varying geometries of each condition or from subjects altering kinematic trends to reduce pain in OA shoulders. In addition, this study may provide a reference for future studies analyzing the kinematics of post TSA shoulders


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 48 - 48
1 Jul 2020
Ng G Daou HE Bankes M y Baena FR Jeffers J
Full Access

Surgical management of cam-type femoroacetabular impingement (FAI) aims to preserve the native hip, restore joint function, and delay the onset of osteoarthritis. However, it is unclear how surgery affects joint mechanics and hip joint stability. The aim was to examine the contributions of each surgical stage (i.e., intact cam hip, capsulotomy, cam resection, capsular repair) towards hip joint centre of rotation and microinstability. Twelve fresh, frozen cadaveric hips (n = 12 males, age = 44 ± 9 years, BMI = 23 ± 3 kg/m2) were skeletonized to the capsule and included in this study. All hips indicated cam morphology on CT data (axial α = 63 ± 6°, radial α = 74 ± 4°) and were mounted onto a six-DOF industrial robot (TX90, Stäubli). The robot positioned each hip in four sagittal angles: 1) Extension, 2) Neutral 0°, 3) Flexion 30°, and 4) Flexion 90°, and performed internal and external hip rotations until a 5-Nm torque was reached in each direction, while recording the hip joint centre's neutral path of translation. After the (i) intact hip was tested, each hip underwent a series of surgical stages and was retested after each stage: (ii) T-capsulotomy (incised lateral iliofemoral capsular ligament), (iii) cam resection (removed morphology), and (iv) capsular repair (sutured portal incisions). Eccentricity of the hip joint centre was quantified by the microinstability index (MI = difference in rotational foci / femoral head radius). Repeated measures ANOVA and post-hoc paired t-tests compared the within-subject differences in hip joint centre and microinstability index, between the testing stages (CI = 95%, SPSS v.24, IBM). At the Extension and Neutral positions, the hip joint centre rotated concentrically after each surgical stage. At Flexion 30°, the hip joint centre shifted inferolaterally during external rotation after capsulotomy (p = 0.009), while at Flexion 90°, the hip joint centre further shifted inferolaterally during external rotation (p = 0.005) and slightly medially during internal rotation after cam resection, compared to the intact stages. Consequently, microinstability increased after the capsulotomy at Flexion 30° (MI = +0.05, p = 0.003) and substantially after cam resection at Flexion 90° (MI = +0.07, p = 0.007). Capsular repair was able to slightly restrain the rotational centre and decrease microinstability at the Flexion 30° and 90° positions (MI = −0.03 and −0.04, respectively). Hip microinstability occurred at higher amplitudes of flexion, with the cam resection providing more intracapsular volume and further lateralizing the hip joint during external rotation. Removing the cam deformity and impingement with the chondrolabral junction also medialized the hip during internal rotation, which can restore more favourable joint loading mechanics and stability. These findings support the pathomechanics of cam FAI and suggest that iatrogenic microinstability may be due to excessive motions, prior to post-operative restoration of static (capsular) and dynamic (muscle) stability. In efforts to limit microinstability, proper nonsurgical management and rehabilitation are essential, while activities that involve larger amplitudes of hip flexion and external rotation should be avoided immediately after surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 104 - 104
1 Feb 2020
Zarei M Hamlin B Urish K Anderst W
Full Access

INTRODUCTION. Controversy exists regarding the ability of unicompartmental knee arthroplasty (UKA) to restore native knee kinematics, with some studies suggesting native kinematics are restored in most or all patients after UKA. 1–3. , while others indicate UKA fails to restore native knee kinematics. 4,5. Previous analysis of UKA articular contact kinematics focused on the replaced compartment. 2,5. , neglecting to assess the effects of the arthroplasty on the contralateral compartment which may provide insight to future pathology such as accelerated degeneration due to overload. 6. or a change in the location of cartilage contact. 7. The purpose of this study was to assess the ability of medial UKA to restore native knee kinematics, contact patterns, and lateral compartment dynamic joint space. We hypothesized that medial UKA restores knee kinematics, compartmental contact patterns, and lateral compartment dynamic joint space. METHODS. Six patients who received fixed-bearing medial UKA consented to participate in this IRB-approved study. All patients (4 M, 2 F; average age 62 ± 6 years) completed pre-surgical (3 weeks before) and post-surgical (7±2 months) testing. Synchronized biplane radiographs were collected at 100 images per second during three repetitions of a chair rise movement (Figure 1). Motion of the femur, tibia, and implants were tracked using an automated volumetric model-based tracking process that matches subject-specific 3D models of the bones and prostheses to the biplane radiographs with sub-millimeter accuracy. 8. Anatomic coordinate systems were created within the femur and tibia. 9. and used to calculate tibiofemoral kinematics. 10. Additional outcome measures included the center of contact in the medial and lateral compartments, and the lateral compartment dynamic joint space (i.e. the distance between subchondral bone surfaces). 11. The results of the three movement trials were averaged for each knee in each test session. All outcome measures were interpolated at 5° increments of knee extension (Figure 2). The average differences between knees at corresponding flexion angles were analyzed using paired t-tests with significance set at p < 0.05. RESULTS. The UKA knee was in 5.3° more varus than the contralateral knee prior to surgery (p=0.005). After surgery, the UKA knee was in 4.9° more valgus than before surgery (p=0.005). The UKA knee was 4.3° more externally rotated than the contralateral knee post-surgery (p=0.05) (Table 1). No significant differences were observed between knees or pre- to post-surgery in lateral compartment dynamic joint space or the center of contact in the medial and lateral tibia compartments (Table 1). DISCUSSION. These results suggest that medial UKA can restore native knee varus without significantly altering lateral compartment joint space or contact location during the chair rise movement. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 137 - 137
1 Jul 2020
Tynedal J Heard SM Hiemstra LA Buchko GM Kerslake S
Full Access

The purpose of this study was to compare intra-operative, clinical, functional, and patient-reported outcomes following revision anterior cruciate ligament reconstruction (ACL-R) with a matched cohort of primary isolated ACL-R. A secondary purpose was to compare patient-reported outcomes within revision ACL-R based on intra-operative cartilage pathology. Between January 2010 and August 2017, 396 patients underwent revision ACL-R, and were matched to primary isolated ACL-R patients using sex, age, body mass index (BMI), and Beighton score. Intra-operative assessments including meniscal and chondral pathology, and graft diameter were recorded. Lachman and pivot shift tests were completed independently on each patient at two-years post-operative by a physiotherapist and orthopaedic surgeon. A battery of functional tests was assssed including single-leg Bosu balance, and four single-leg hop tests. The Anterior Cruciate Ligament-Quality of Life Questionnaire (ACL-QOL) was completed pre-operatively and two-years post-operatively. Descriptive statistics including means (M) and standard deviations (SD), and as appropriate paired t-tests were used to compare between-groups demographics, the degree and frequency of meniscal and chondral pathology, graft diameter, rate of post-operative ACL graft laxity, the surgical failure rate, and ACL-QOL scores. Comparative assessment of operative to non-operative limb performance on the functional tests was used to assess limb symmetry indices (LSI). Revision ACL-R patients were 52.3% male, mean age 30.7 years (SD=10.2), mean BMI 25.3 kg/m2 (SD=3.79), and mean Beighton score 3.52 (SD=2.51). In the revision group, meniscal (83%) and chondral pathology (57.5%) was significantly more frequent than in the primary group (68.2% and 32.1%) respectively, (p < 0 .05). Mean graft diameter (mm) in the revision ACL-R group for hamstring (M=7.89, SD=0.99), allograft (M=8.42, SD=0.82), and patellar or quadriceps tendon (M=9.56, SD=0.69) was larger than in the primary ACL-R group (M=7.54, SD=0.76, M=8.06, SD=0.55, M=9, SD=1) respectively. The presence of combined positive Lachman and pivot shift tests was significantly more frequent in the revision (21.5%) than primary group (4.89%), (p < 0 .05). Surgical failure rate was higher in the revision (10.3%) than primary group (5.9%). Seventy-three percent of revision patients completed functional testing. No significant LSI differences were demonstrated between the revision and primary ACL-R groups on any of the functional tests. No statistically significant differences were demonstrated in mean preoperative ACL-QOL scores between the revision (M=28.5/100, SD=13.5) and primary groups (M=28.5/100, SD=14.4). Mean two-year scores demonstrated statistically significant and minimally clinically important differences between the revision (M=61.1/100, SD=20.4) and primary groups (M=76.0/100, SD=18.9), (p < 0 .05). Mean two-year scores for revision patients with repair of the medial (M=59.4/100, SD=21.7) or lateral meniscus (M=59.4/100, SD=23.6), partial medial meniscectomy (M=59.7/100, SD=20), grade three or four osteoarthritis (M=55.9/100, SD=19.5), and medial femoral condyle osteoarthritis (M=59.1/100, SD=18) were lower compared with partial lateral meniscectomy (M=67.1/100, SD=19.1), grade one or two osteoarthritis (M=63.8/100, SD=18.9), and lateral femoral condyle osteoarthritis (M=62, SD=21). Revision ACL-R patients demonstrated a greater amount of meniscal and chondral pathology at the time of surgery. Two-years post-operative these patients demonstrated higher rates of graft laxity and lower ACL-QOL scores compared with the primary ACL-R group. Higher grade and medial sided osteoarthritis was associated with inferior ACL-QOL scores in revision ACL-R


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 55 - 55
1 Oct 2018
Jennings JM Loyd BJ Miner T Yang CC Stevens-Lapsley J Dennis DA
Full Access

Introduction. Closed suction intraarticular drain (CSD) use after total knee arthroplasty (TKA) has been studied with regards to wound healing and range of motion, however, no data exist on how CSD use impacts knee joint effusion and quadriceps strength. The primary purpose of this study was to determine whether CSD use influences recovery of quadriceps strength. Secondary outcomes examined effects of CSD on intraarticular effusion, lower limb swelling, knee range of motion (ROM), pain and wound healing complications. Methods. Twenty-nine patients undergoing same-day bilateral TKA were enrolled in a prospective, randomized blinded study. Subjects were randomized to receive a CSD on one lower extremity while the contralateral limb had the use of a subcutaneous drain (SCDRN) without the use of suction. Isometric quadriceps strength was collected as the primary outcome. Secondary outcomes consisted of quadriceps muscle activation, intraarticular effusion measured via ultrasound, lower extremity swelling measured with bioelectrical impendence, lower extremity girth, ROM, and pain. Outcomes were assessed preoperatively and postoperatively at day 2, 2 and 6 weeks and 3 months. Differences in limbs were determined using paired t-tests or Wilcoxon signed rank tests. Results. No significant differences were identified between limbs prior to surgery for the primary or secondary outcomes. No significant differences in quadriceps strength were seen between CSD and SCDRN limbs at postoperative day 2 (p = 0.09), two weeks (p=0.7), six weeks (p=0.3), or three months (p=0.5). Secondary outcomes, of quadriceps activation battery, intraarticular effusion, lower extremity swelling, ROM, and pain were not found to significantly differ at any time point following surgery. Conclusion. The use of CSD during TKA did not influence quadriceps strength, quadriceps activation, intraarticular effusion, bioelectrical measure of swelling, ROM, or pain. The results of this study have limited drain use by the authors in primary uncomplicated TKA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 42 - 42
1 Oct 2018
Schloemann DT Edelstein AI Barrack RL
Full Access

Introduction. Malposition of the acetabular component in total hip arthroplasty (THA) is linked to multiple adverse outcomes. Changes in the sagittal plane position of the pelvis, owing both to patient positioning in the operating room and to altered spinopelvic alignment following surgery, potentially contribute to variation in component position. The dynamics of sagittal plane pelvic position before, during, and after THA have not been defined. We measured the differences in pelvic ratio, a measure of sagittal plane pelvic position, between preoperative, intraoperative, and postoperative anteroposterior (AP) radiographs of patients undergoing THA in the lateral decubitus position. Methods. We retrospectively compared the radiographic pelvic ratio among 90 patients undergoing THA. AP radiographs were obtained in the standing position preoperatively and at 6 weeks after surgery; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post anesthesia care unit (PACU). Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Radlink software was used to determine the pelvic ratio on each radiograph. Changes in apparent cup position based on changes in pelvic ratio were calculated using data from the literature, and a change of at least 10 degrees in acetabular component position was defined as clinically meaningful. Analyses were performed using paired t-tests, with p<0.05 defined as significant. Results. 54% of patients had a change in pelvic ratio large enough to alter the apparent acetabular component anteversion by 10 degrees (49% increased and 6% decreased), and 12% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (12% increased and 0% decreased) when the intraoperative AP radiograph was compared to the preoperative AP radiograph. 36% of patients had a change in pelvic ratio from the preoperative radiograph to the 6 week preoperative radiograph large enough to alter the apparent acetabular component anteversion by 10 degrees (5% increased and 31% decreased), and 8% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (6% increased and 1% decreased). Discussion. Changes in the sagittal plane pelvic position between preoperative, intraoperative, and postoperative radiographs occur in a substantial number of patients. These changes correspond to altered functional position of the acetabular component in over half of patients on the intraoperative radiograph and over one third of patients on postoperative radiographs. This variability suggests that intraoperative imaging may be useful for avoiding outliers of component position, and calls into question the feasibility of achieving targeted component positions based on preoperative imaging alone


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 66 - 66
1 May 2017
Jolles-Haeberli B Meyer V Cavinato A Chakravarty P Omoumi P Favre J
Full Access

Background. Some models of knee osteoarthritis (OA) suggest that the properties of knee tissues are adapted in healthy joints, and that OA development is due to a breakdown in the equilibrium among tissue properties. Cartilage thickness and bone density are particularly important properties in this regard because both are related to the mechanical environment. This study tested the hypothesis that locations of thickest cartilage are associated with locations where bone density is the highest in non-OA tibias. Method. CT-arthrography was performed on six non-OA subjects (2 males; 58± 15 years old). Images were segmented to build 3D models of the bone and cartilage structures. Maps of cartilage thickness were calculated for the medial and lateral subchondral bone areas by measuring the distance between bone and cartilage structures. Bone density maps were calculated based on the intensity of the CT-arthrography signal in the first 3mm of bone. The location of thickest cartilage and most dense bone were measured in the medial and lateral compartments. These locations were then normalised, and paired t-tests and linear regressions were performed to compare the thickness and density locations. Results. In the medial compartment, the location of highest bone density was significantly more medial than the location of thickest cartilage (p=0.03). Additionally, the location of both features were highly correlated along the anterior-posterior direction (R⁁2=0.92). In the lateral compartment, the location of highest bone density was correlated with the location of thickest cartilage along the medial-lateral direction (R⁁2 =0.64). Conclusion. This study showed that the location of highest bone density is correlated with the location of thickest cartilage in non-OA tibias, thus supporting the idea that knee tissues are adapted in healthy knees


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 110 - 110
1 May 2017
Hurley R Devitt A
Full Access

Background. New marker free motion analysis systems are being used extensively in the area of sports medicine and physiotherapy. The accuracy and validity of use in an orthopaedic setting have not been fully assessed for these newer marker free motion analysis systems. The aim of this study is to compare leg length and varus/valgus knee measurements performed by leg measurement x-ray, and performed using the new marker free motion analysis system (Organic motion biostage). Methods. Patients attending the orthopaedic department for total knee replacements were recruited. They underwent radiological leg measurement x-ray, clinical leg measurement, and finally assessment using the organic motion biostage system. These were analysed using the motion monitor software, microsoft excel and minitab 16. Results. For 23 patients assessed, all methods showed a statistically significant result (p<0.05) using paired t-tests. This rejects the null hypothesis- indicating that organic motion does not have the accuracy currently to measure leg length or knee varus/valgus angle. Conclusions. Results indicate that the organic motion biostage system- a new marker free motion analysis system, is not feasible currently as a method of accurately measuring leg-length. Given the current modelling methods used by this new system there are limitations, that if addressed may yet allow the system to become a useful clinical tool. These authors feel it still has applications in orthopaedics as a useful, quick, and easy to use method of motion analysis and functional screen in orthopaedic patients, and warrants further investigation. We also present a case of lumbar pedicle subtraction osteotomy, and show how markerless motion analysis is a useful tool for assessing spinal sagittal balance, and its effect on the biomechanics of walking. Level of Evidence. IV


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 50 - 50
1 Dec 2017
Touchette M Anglin C Guy P Amlani M Hodgson A
Full Access

Fluoroscopic C-arms are operated by medical radiography technologists (RTs) in Canadian operating rooms (ORs). While they do receive formal, accredited training, most of it is theoretical, rather than hands-on. During their first encounters in the OR, new RTs can experience difficulty achieving the radiographic views required by surgeons, often needing several scout X-rays during C-arm positioning. Furthermore, ambiguous language by surgeons often inadequately conveys their request. The result is often frustration, unnecessary radiation exposure, and added OR time. The purpose of this study was to evaluate the value of artificial X-rays in improving C-arm positioning performance, with inexperienced C-arm users. We developed an Artificial X-ray Imaging System (AXIS) that generates Digitally Reconstructed Radiographs (DRRs), or artificial X-ray images, based on the relative position of a C-arm and manikin. 30 participants were enrolled in the user study and performed four activities: an introduction session, an AXIS-guided evaluation, a non-AXIS-guided evaluation, and a questionnaire. The main goal of the study was to assess C-arm positioning performance with and without AXIS guidance. For each evaluation, the participants had to replicate a set of target X-ray images by taking real radiographs of the manikin with the C-arm. During the AXIS evaluation, artificial X-rays were generated at 2 Hz for guidance, while in the non-AXIS evaluation, the participants had to acquire real scout X-rays to guide them toward the correct view. For each imaging task the number of real X-rays and time required per task was recorded, and the C-arm's pose was tracked and compared to the target pose to determine positioning accuracy; these were averaged for each participant and condition. Hypothesis testing on the means and paired t-tests were carried out using a significance level of α=0.05. On average, users took significantly fewer real scout X-ray images (53% fewer (2.8 vs 6.0), p<0.001) when guided by AXIS. Lateral distance accuracy was improved by 10% for final C- arm positions and by 26% for the most accurate intermediate C-arm positions when guided by AXIS (p<0.05). There was no significant difference in average task time or angular accuracies between the AXIS and non-AXIS evaluations. Overall, we are encouraged by these findings and plan to further develop this system with the goal of deploying it both for training and intraoperative uses


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 32 - 32
1 Apr 2017
Kabariti R Whitehouse M
Full Access

Background. Recent studies have suggested that full-limb radiographs are more accurate and sensitive than short film radiographs for pre-operative measurement of the anatomical angles required to achieve optimal knee alignment in Total Knee Arthroplasty (TKA). However, there are drawbacks associated with their use including excess radiation to the pelvic organs, the need for specialised radiography equipment and increased cost. Given these drawbacks, we compared the use of MRI scans, a commonly performed pre-operative investigation, with short film knee radiographs for measurement of knee alignment. Objective. To investigate whether knee alignment measurements made on MRI scans correlate with those measured on short film knee radiographs in patients with osteoarthritic knees. Methods. We retrospectively reviewed short film knee radiographs and MRI scans of 50 patients with knee osteoarthritis. The plain radiographs had to be performed whilst weight bearing. The MRI scans were performed supine and non-weight bearing. The exclusion criteria included previous trauma to the knee, previous TKA and previous fracture of the lower limb. 4 angle measurements defined by The American Knee Society: alpha, beta, sigma and gamma were measured using each of the 2 modalities. Kolmogorov-Smirnov and two- tailed paired t-tests were used for statistical analysis of the results. Pearson correlation coefficient was used for the measure of dependence. Results. The alpha, beta, sigma and gamma angles obtained using the MR images were different to those obtained using short film weight bearing knee radiographs by −3°± 1° (p < 0.001), 1° ± 3° (p=0.002), 1° ± 3° (p=0.047) and 1° ± 4° (p=0.113) respectively. There was a weak correlation between the MRI based method and the radiographic method in measuring all 4 angles. Conclusions. Our results have shown that the angular measurements performed on MR images should be interpreted with caution as they may vary depending on the MRI slice selected for evaluation. The differences observed and the weak correlation between the 2 modalities may be due to the different scopes used for determining the femoral or tibial axes. The measurements obtained using the plain radiographs were interpreted using a single 2D projection of a 3D structure. However, the measurements of the MR images were evaluated using a 2D image of a slice through a 3D structure. In conclusion, the use of MRI scans for pre-operative planning in TKA may not be advisable at this stage as the angular measurements obtained using the MR images were poorly correlated to those obtained using plain radiographs


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_9 | Pages 8 - 8
1 Aug 2015
Ashby E Montpetit K Hamdy R Fassier F
Full Access

The aim was to assess the long-term impact of humeral and forearm rodding on functional ability, grip strength, joint range of motion and angular deformity in children with osteogenesis imperfecta. A retrospective chart review was conducted on 57 children with osteogenesis imperfecta who underwent humeral rodding or forearm rodding at our institution between 1996 and 2013. Functional ability was assessed using the self-care and mobility domains of the Pediatric Evaluation and Disability Inventory (PEDI). Grip strength was measured using a dynamometer and joint range of motion with a goniometer. Deformity was measured on radiographs of the humerus or forearm. Outcomes were assessed pre-operatively and every year post-operatively. Differences between pre-operative and 1-year post-operative outcomes were compared using paired T-tests. In 44 patients with a minimum of 2 years follow-up, outcome measures at 1-year post-surgery were compared to those at the latest clinic visit (mean follow-up = 8.0 years). Humeral and forearm rodding resulted in a significant improvement in PEDI self-care score (mean change =5.75, p=0.028 for the humerus, mean change = 6.77, p=0.0017 for the forearm) and mobility score (mean change =3.59, p=0.008 for the humerus, mean change =7.21, p=0.020 for the forearm) at 1 year post-surgery. Grip strength improved following forearm rodding (mean change = +6.13N, p=0.015) but not humeral rodding. Joint range of movement improved following humeral rodding but not forearm rodding. There was a significant improvement in radiographic angular deformity of the forearm and humerus following surgery (p<0.0001). Over 80% of improvements were maintained in the long-term. Humeral and forearm rodding in children with osteogenesis imperfecta leads to long-term improvement in functional ability and angular deformity


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 7 - 7
1 Nov 2016
Elwell J Willing R
Full Access

Failure of reverse total shoulder arthroplasty (rTSA) due to loosening of the metaglene remains a concern. The metaglene is typically affixed to the glenoid via four peripheral bone screws, and the orientations of these screws can affect the stability of the metaglene. The purpose of this finite element analysis (FEA) study was to investigate whether screw orientations should be considered on a patient-specific basis to maximise early fixation. Three-dimensional geometries of four scapula specimens were obtained by segmenting from CT data in 3D Slicer. A metaglene and four rigidly attached 4.5 mm diameter, 18 mm long cylinders representing screws, were placed on each reamed glenoid. Each screw was placed at one of four orientations, 15° or 7.5° toward or away from the central axis of the metaglene face, while all others were held in the baseline (BL) configuration, where all screws were perpendicular to the metaglene face. Finite element models were created by meshing with linear tetrahedral elements. Material properties of titanium (E=113.8 GPa, v=0.34) were applied to the metaglene and screws. Cortical bone material properties were considered uniform (E=17.5 GPa, ν=0.3) while cancellous bone material properties were non-uniform and mapped on an element-by-element basis using CT attenuation data. The scapula was fully constrained, and a 252 N superiorly oriented shear force was applied to the inferior portion of the metaglene. Contact was modelled at bone-implant and bone-screw interfaces. Displacements of the metaglene with respect to the glenoid were measured. The orientations of each screw that minimised in-plane displacement were used for specimen-specific (SS) configurations. A global (GL) configuration was also defined based on the averages of SS orientations. FE model-predicted metaglene displacements of the SS, GL, and BL screw configurations were compared using paired t-tests. The average in-plane metaglene displacements for the SS, GL, and BL configurations were 4.8 ± 1.2, 6.5 ± 3.7, and 5.3 ± 1.5 um, respectively. SS configurations significantly decreased displacements by −0.4 ± 0.3 um (−8.5%, p = 0.024) when compared to BL, but the difference of −1.6 ± 3.1 um (25.3%, p = 0.187) was not significant when compared to the GL configuration. In general, the SS configurations resulted in smaller metaglene displacements than the GL configurations, however the difference was not statistically significant. In one specimen, the GL configuration resulted in abnormally large displacements. These results indicate that, while on average, patient-specific orientations won't yield significantly greater fixation than global configurations; non-patient-specific configurations can, in some cases, yield poor results. Therefore, to ensure optimal fixation for all patients, screw orientations should be considered on a patient-specific basis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 60 - 60
1 Jan 2017
Penny J Speedsberg M Kallemose T Bencke J
Full Access

Increase in heel height increases peak pressure under the forefoot. Customized shoe inlays with metatarsal lift, arch support has demonstrated lowered forefoot pressure and increase in the subjective comfort. A commercial shoe brand (Roccamore) has introduced an off-the-rack stiletto with a slim (1 cm. 2. ) 8 cm heel plus 2 cm platform with metatarsal lift, arch support and heel cap claiming it will reduce the discomfort associated with high heels. The primary aim of this study was to compare the pressure under the forefoot, arch, heel and toes in this “orthopaedic” stiletto (OS) to a standard stiletto of the same heel height without inlays (SS) and a control sneaker (SN). Secondary aims were to measure the comfort under the forefoot, heel and arch during everyday use. Finally to investigate if any pressure measurements were correlated to comfort or any anatomical/clinical feature of the foot. 22 women, aged 40 (21–62), accustomed to stilettos, walked at 4 km/hr on a level treadmill in all three shoe types. Peak pressure (kPa) and pressure-time integral (kPa/sec) under 2+3rd and first metatarsal heads, the arch/midfoot and heel were measured during 10 consecutive steps at 50 Hz using Novel Pedar-X pressure distribution insoles. Standing X-rays and a standardized clinical examination were carried out. Mundermanns comfort VAS and daily steps were recorded for each shoe type during 3 full days. (0= worst to 150 mm= most comfortable). Data were compared with paired t-tests and regression analysis. Statistical significance is reported as p<0.05=, p<0.01=, p<0.001=. Peak pressure: Compared to SS the peak pressure under the 2+3 metatarsals was reduced to 82% in the OS and 60% in the SN. Under the first metatarsal it was reduced to 73% and 40%, respectively. Under the arch it was similar for SN and OS and 30% lower for the SS. Under the heel the OS was 27–28% lower than SS and SN. The same reductions, as well as similarities in the arch were seen in the pressure-time integrals, although with smaller difference between OS and SS, and conversely larger reductions in the SN to 49% under 2+3 metatarsals and 43% under the first. For forefoot, arch and heel, the comfort was rated highest for the SN and lowest for the SS. No statistical difference between OS and SS in the arch. For each mm the second metatarsal was longer than the first, the peak pressure under MT2+3 rose 13 kPa (95%CI: 7 to 19) and the pressure time integral 3 kPa/s (1–5). No effect of first ray ROM or stability. The forefoot VAS score dropped (less comfortable) 0.3 mm for each kPa/s the pressure time integral rose under the MT2+3. Peak pressure parameters or daily steps were not statistically significantly related to the forefoot comfort. A mass produced “orthopaedic” stiletto can reduce the pressure approaching those achieved in a sneaker and increase comfort for the user. An increase in pressure-time integral under 2+3 metatarsals increases the discomfort and the pressure is increased in index-minus feet