Many factors have been reported to affect the functional survival of OCA transplants, including chondrocyte viability at time of transplantation, rate and extent of allograft bone integration, transplantation techniques, and postoperative rehabilitation protocols and adherence. The objective of this study was to determine the optimal subchondral bone drilling technique by evaluating the effects of hole diameter on the material properties of OCAs while also considering total surface area for potential biologic benefits for cell and vascular ingrowth. Using allograft tissues that would be otherwise discarded in combination with deidentified diagnostic imaging (MRI and CT), a model of a large shell
In this study, we aimed to investigate tibiofemoral and allograft loading parameters after OCA transplantation using tibial plateau shell grafts to characterize the clinically relevant biomechanics that may influence joint kinematics and OCA osseointegration after transplantation. The study was designed to test the hypothesis that there are significant changes in joint loading after tibial plateau OCA transplantation that may require unique post-operative rehabilitation regimens in patients to restore balance in the knee joint. Fresh-frozen cadaveric knees (n=6) were thawed and mounted onto a 6 DOF KUKA robot. Specimens were size matched to +2 mm for the medial-to-lateral width of the medial tibial hemiplateaus. Three specimens served as allograft recipient knees and three served as donor knees. Recipient knees were first tested in their native state and then tested with size-matched medial tibial hemiplateau shell grafts (n=3) prepared from the donor knees using custom-cut tab-in-slot and subchondral drilling techniques. Tekscan sensors were placed in the joint spaces to evaluate the loading conditions under 90N biaxial loading at full extension of the knee before and after graft placement. The I-Scan system used in conjunction analyzed the total force, pressure distribution, peak pressure, and center of force within the joint space. Data demonstrated significant difference (p<0.05) in joint space loading after graft implantation compared to controls in both lateral and medial tibial plateaus. The I-Scan pressure mapping system displayed changes in femoral condylar contact points as well. The results demonstrated that joint space loading was significantly different (p<0.05) between all preoperative and postoperative cadaveric specimens. Despite the best efforts to size match grafts, slight differences in the host's joint geometry resulted in shifts of contact areas between the tibial plateau and femoral condyle therefore causing either an increase or decrease in pressure measured by the sensor. This concludes that accuracy in graft size matching is extremely important to restoring close to normal loading across the joint and this can be further ensured through postoperative care customized to the patient after OCA surgery.
Background. Based on decellularisation and cleaning processes of trabecular bone and fibrocartilage, an
Introduction and Objective.
We used fresh small-fragment
Repeated trauma to the radial head may be one of the causative factors in the genesis of osteochondritis dissecans of the capitellum. We measured the force, contact area and pressure across the radiocapitellar articulation of the elbow before and after radial shortening osteotomy in five fresh-frozen cadaver upper limbs with loads of 45, 90 and 135 N, respectively. Measurements were made on pressure-sensitive film placed in the radiocapitellar articulation with the forearm in the supinated, neutral and pronated positions before and after radial shortening. Radial shortening significantly reduced the mean force and contact area across the radiocapitellar articulation in all positions of the forearm.
We attempted to repair full-thickness defects in the articular cartilage of the trochlear groove of the femur in 30 rabbit knee joints using allogenic cultured chondrocytes embedded in a collagen gel. The repaired tissues were examined at 2, 4, 8, 12 and 24 weeks after operation using histological and histochemical methods. The articular defect filling index measurement was derived from safranin-O stained sections. Apoptotic cellular fractions were derived from analysis of apoptosis
The aim of this study was to determine whether subchondral bone influences in situ chondrocyte survival. Bovine explants were cultured in serum-free media over seven days with subchondral bone excised from articular cartilage (group A), subchondral bone left attached to articular cartilage (group B), and subchondral bone excised but co-cultured with articular cartilage (group C). Using confocal laser scanning microscopy, fluorescent probes and biochemical assays, in situ chondrocyte viability and relevant biophysical parameters (cartilage thickness, cell density, culture medium composition) were quantified over time (2.5 hours vs seven days). There was a significant increase in chondrocyte death over seven days, primarily within the superficial zone, for group A, but not for groups B or C (p <
0.05). There was no significant difference in cartilage thickness or cell density between groups A, B and C (p >
0.05). Increases in the protein content of the culture media for groups B and C, but not for group A, suggested that the release of soluble factors from subchondral bone may have influenced chondrocyte survival. In conclusion, subchondral bone significantly influenced chondrocyte survival in articular cartilage during explant culture. The extrapolation of bone-cartilage interactions in vitro to the clinical situation must be made with caution, but the findings from these experiments suggest that future investigation into in vivo mechanisms of articular cartilage survival and degradation must consider the interactions of cartilage with subchondral bone.