header advert
Results 1 - 20 of 392
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 74 - 74
1 Jul 2022
Phoon KM Afzal I Sochart D Gikas P Asopa V Kader D
Full Access

Abstract. Introduction. The NHS generates 4–5% of the nation's total carbon emissions and over 500,000 tonnes of waste annually. Up to one-third of waste from orthopaedic procedures are recyclable, with large joint arthroplasties producing more than other subspecialties. However, there is limited evidence demonstrating the principles of sustainability and its benefits within orthopaedic surgery. This study aimed to analyse the environmental impact and sustainable initiatives undertaken within orthopaedic surgery. Methodology. A systematic review was performed according to PRISMA guidelines. The systematic search was conducted through EMBASE, Medline, and PubMed libraries. Results. Four studies analysed waste management in primary total knee replacements (TKRs) during the perioperative period. The most prevalent environmental issue was waste management. A total of 33 TKRs were observed across the studies. The mean waste generated per TKR was 13.1kg (range 11.6-15.1kg), with up to 69.9% being hazardous waste. The number of waste streams reported ranged from two to six. This study has further demonstrated that TKRs generated the highest amount of waste per procedure compared to other orthopaedic subspecialties. Three studies reported recycling waste, with up to 43% of total waste from TKRs being potentially recyclable material. Conclusion. Primary TKRs one of the largest contributors of waste generated by orthopaedic procedures during the perioperative period. Environmental sustainability in orthopaedic surgery is a growing area of interest with a wide potential for meaningful change. Further research is needed to study the cumulative carbon footprint of primary TKRs and long-term benefits of environmentally sustainable changes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 5 - 5
7 Aug 2023
Berry K Von Bormann R Roche S Laubscher M McCollum G Held M
Full Access

Abstract. Background. Orthopaedic training in Southern Africa is largely focused on trauma, although elective procedures, such as knee arthroscopy are increasing. This is especially true in the private sector where most trainees will practice. The primary aim of this study was to assess the arthroscopic competency of orthopaedic trainees in a setting of limited resources. Methods. A prospective observational cohort study was carried out. Orthopaedic trainees of a Southern African university hospital performed basic arthroscopy on a knee model. Their surgical competency was assessed by two surgeons proficient in arthroscopy using the modified Basic Knee Arthroscopy Skill Scoring System (mBAKSSS). Results. A total of 16 trainees (12 male) were included (6 junior and 10 senior trainees). The median age of participants was 36 (34.8, 37). The median mBAKSSS was 28.0 (20.3, 32.5) but showed a large variability (12.0–42.5). The overall reliability was excellent with Cronbach's Alpha of 0.91 and interclass correlation of 0.91 [95% CI 0.75, 0.97]. Conclusions. The average knee arthroscopy proficiency of our trainees is comparable to those of international training programs, but there was great variability with inconsistent skills amongst the trainees. This calls for improved and reproducible arthroscopy training and skills transfer, exposure to procedures and ongoing assessment


Abstract. Introduction. Revision total knee arthroplasty (RTKA) is a complex procedure with higher rates of re-revision, complications and mortality compared to primary TKA. We report the effects of the establishment of a Revision Arthroplasty Network (The East Midlands Specialist Orthopaedic Network; EMSON). Methodology. The Revision Arthroplasty Network was established in January 2015 and covered the Nottinghamshire and Lincolnshire areas of England. This comprises a collaborative weekly multidisciplinary meeting where upcoming RTKA procedures are discussed, and a plan agreed. Using the Hospital Episode Statistics database, RTKA procedures carried out between 2011 and 2018 from the five EMSON hospitals were compared to all other hospitals in England. Age, sex, and Hospital Frailty Risk scores were used as covariates. The primary outcome was re-revision surgery within 1 year of the index revision. Secondary outcomes were re-revision surgery within two years, any complication within one and two years and median length of stay. Results. 33,828 RTKA procedures were performed across England; 1,028 (3.0%) were conducted within EMSON. Re-revision rates within 1 year were 11.6% and 7.4% pre- and post-intervention respectively within the network. This compares to a pre-post change from 11.7% to 9.7% for the rest of England. In comparative interrupted time-series analysis, there was a significant immediate improvement in re-revision rates for EMSON hospitals compared to the rest of England at 1 year (p = 0.024) and 2 years (p=0.032). Conclusion. Re-revision rates for RTKA improved significantly at one and two years with the introduction of EMSON, when compared to the rest of England


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 52 - 52
1 Oct 2019
Korte EA Malkani AL Gaskins J Hartley B Langman LJ Jannetto P McMillin G Maluf C Jortani SA
Full Access

Introduction. Insufficient pain control following lower extremity surgery can increase length of stay, readmission rates, and impair postoperative outcome. It has been shown that CYP2D6 genotypes predict function of the enzyme responsible for conversion of hydrocodone to hydromorphone (active metabolite) and plasma concentration of hydromorphone best predicted analgesic response. Purpose of this study was to evaluate relationship of CYP2D6 genotypes, drug-drug interactions, and plasma drug concentrations in patients undergoing lower extremity surgery. Methods. A prospective cohort of 271 orthopedic patients undergoing lower extremity surgery including TKA, THA and trauma were queried. Patients treated with hydrocodone were enrolled and tested for plasma concentrations of hydrocodone and hydromorphone. CYP2D6 genotyping was performed. Medications co-administered with hydrocodone during perioperative and postoperative periods were queried. Results. Out of 271 patients enrolled, only 41 (15%) had detectable hydromorphone (i.e. >0.5 ng/mL). 86% were extensive (normal) metabolizers, 7% were intermediate metabolizers, 5% poor metabolizers and 2% were ultra rapid metabolizers. 179 subjects were not administered any inhibitors of CYP2D6 whereas 92 were on at least one inhibitor. 33 (18%) with no pharmacological inhibitors had detectable hydromorphone, whereas only 7 (7.6%) on inhibitors had hydromorphone detected above the lower limit of quantification (0.5ng/mL), p=0.033. Diphenhydramine, fluoxetine, hydralazine, duloxetine, bupropion and sertraline, were the most common CYP2D6 inhibitors co-administered with hydrocodone in this cohort. Conclusions. Patients' home medications and selection of various drugs in the postoperative setting could impact the pharmacokinetics and pharmacodynamics of hydrocodone leading to a diminished analgesic response. We conclude that health care providers should become familiar with the inhibitors of CYP2D6 to obtain the best response with the use of hydrocodone following lower extremity surgery. Additional work is required to determine the ideal opioid for an individual patient's genotype following lower extremity orthopedic surgery. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 26 - 26
7 Aug 2023
Jameson C Wylde V
Full Access

Abstract

Introduction

People from ethnic minority backgrounds are underserved in healthcare and research. We co-developed a checklist to promote good practice for inclusive community patient and public involvement (PPI).

Methods

We worked with three community groups in Bristol to develop the checklist – Dhek Bhal (South Asian community), Malcolm X Elders (African Caribbean community) and My Friday Coffee Morning (predominantly Somali women). We worked with group leaders to better understand the needs of the groups. We visited each group at least three times and used informal and open discussions tailored to how each group preferred to work. We paid for community leaders’ time, interpretation and transport where needed, as well as contributing towards activities and catering as suggested by group leaders.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1555 - 1560
4 Oct 2021
Phillips JRA Tucker K

Aims

Knee arthroplasty surgery is a highly effective treatment for arthritis and disorders of the knee. There are a wide variety of implant brands and types of knee arthroplasty available to surgeons. As a result of a number of highly publicized failures, arthroplasty surgery is highly regulated in the UK and many other countries through national registries, introduced to monitor implant performance, surgeons, and hospitals. With time, the options available within many brand portfolios have grown, with alternative tibial or femoral components, tibial insert materials, or shapes and patella resurfacings. In this study we have investigated the effect of the expansion of implant brand portfolios and where there may be a lack of transparency around a brand name. We also aimed to establish the potential numbers of compatible implant construct combinations.

Methods

Hypothetical implant brand portfolios were proposed, and the number of compatible implant construct combinations was calculated.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 894 - 897
15 Nov 2022
Makaram NS Murray IR Geeslin AG Chahla J LaPrade RF

Aims. Multiligament knee injuries (MLKI) are devastating injuries that can result in significant morbidity and time away from sport. There remains considerable variation in strategies employed for investigation, indications for operative intervention, outcome reporting, and rehabilitation following these injuries. At present no study has yet provided a comprehensive overview evaluating the extent, range, and overall summary of the published literature pertaining to MLKI. Our aim is to perform a methodologically rigorous scoping review, mapping the literature evaluating the diagnosis and management of MLKI. Methods. This scoping review will address three aims: firstly, to map the current extent and nature of evidence for diagnosis and management of MLKI; secondly, to summarize and disseminate existing research findings to practitioners; and thirdly, to highlight gaps in current literature. A three-step search strategy as described by accepted methodology will be employed to identify peer-reviewed literature including reviews, technical notes, opinion pieces, and original research. An initial limited search will be performed to determine suitable search terms, followed by an expanded search of four electronic databases (MEDLINE, EMBASE, Cochrane Database of Systematic Reviews, and Web of Science). Two reviewers will independently screen identified studies for final inclusion. Dissemination. We will map key concepts and evidence, and disseminate existing research findings to the wider orthopaedic and sports medicine community, through both peer-reviewed and non-peer-reviewed literature, and conference and in-person communications. We will highlight gaps in the current literature and determine future priorities for further research. Cite this article: Bone Jt Open 2022;3(11):894–897


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 43 - 43
7 Aug 2023
Lewis A Bucknall K Davies A Evans A Jones L Triscott J Hutchison A
Full Access

Abstract. Introduction. A lipohaemarthrosis seen on Horizontal beam lateral X-ray in acute knee injury is often considered predictive of an intra-articular fracture requiring further urgent imaging. Methodology. We retrospectively searched a five-year X-ray database for the term “lipohaemarthrosis”. We excluded cases if the report concluded “no lipohaemarthrosis” or “lipohaemarthrosis” AND “fracture”. All remaining cases were reviewed by an Orthopaedic Consultant with a special interest in knee injuries (AD) blinded to the report. X-rays were excluded if a fracture was seen, established osteoarthritic change was present, a pre-existing arthroplasty present or no lipohaemarthrosis present. Remaining cases were then studied for any subsequent Radiological or Orthopaedic surgical procedures. Results. 136 cases were identified and reviewed by an Orthopaedic Consultant. 31 were excluded for no lipohaemarthrosis (n= 11), for degenerative change (n=9), for fracture (n=4), for existing arthroplasty (n=4) and for data errors (n=3). The remaining 105 patients had a mean age of 32, and range 5–90 years. 66 patients underwent further imaging in the form of MRI scan (n=47), CT Scan (n=9) repeat x-rays (n=9) and ultrasound (n=1). 27 fractures were identified. Surgery was performed in 12 cases (11%). Two (2%) urgently (One ACL reconstruction plus meniscus repair, one for ORIF of tibial plateau fracture). Ten (10%) had elective surgery (6 for ACL reconstruction, 2 for ACL reconstruction plus meniscus repair, 2 for loose body removal. Conclusion. The presence of a lipohaemarthrosis on x-ray following acute knee injury was a poor predictor of intra-articular fracture (26%) or need for urgent surgery (2%)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 8 - 8
7 Aug 2023
Kaka A Shah A Yunus A Patel A Patel A
Full Access

Abstract. Introduction. Challenges in surgical training have led to the exploration of technologies such as augmented reality (AR), which present novel approaches to teaching orthopaedic procedures to medical students. The aim of this double-blinded randomised-controlled trial was to compare the validity and training effect of AR to traditional teaching on medical students’ understanding of total knee arthroplasty (TKA). Methodology. Twenty medical students from 7 UK universities were randomised equally to either intervention or control groups. The control received a consultant-led teaching session and the intervention received training via Microsoft HoloLens, where surgeons were able to project virtual information over physical objects. Participants completed written knowledge and practical exams which were assessed by 2 orthopaedic consultants. Training superiority was established via 4 quantitative outcome measures: OSATS scores, a checklist of TKA-specific steps, procedural time, and written exam scores. Qualitative feedback was evaluated using a 5-point Likert scale. Results. AR training was superior in teaching basic technical proficiency and understanding of TKA, with the intervention group significantly outperforming the control group in 3 metrics [OSATS (38.6%, p=0.021), checklist (33%, p=0.011) and written exam (54.5%, p=0.001)]. Procedural time was equivalent between cohorts (p=0.082). AR was rated as significantly more enjoyable (p=0.044), realistic (p=0.003), easy to understand (p=0.040), and proficient in teaching (p=0.02). Conclusion. In this adequately powered, double-blinded randomised-controlled trial, AR training demonstrated substantially improved translational technical skills and knowledge needed to understand TKA over traditional learning in medical students. Additionally, the results showed face, content, and transfer validity for AR in surgical training


Aims. Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear. Methods. A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of knee arthroplasty PJI, focusing specifically on isolated micro-organisms at both the first- and second-stage procedure. Patient demographics, medical, and orthopaedic history data, including postoperative outcomes and subsequent treatment, were obtained from the electronic records and medical notes. Results. The study cohort consisted of 84 patients, of whom 59.5% (n = 50) had successful eradication of their infection at a mean follow-up of 4.7 years. For the 34 patients who had recurrence of infection, 58.8% (n = 20) had a change in isolated organism, compared to 18% (n = 9) in the infection eradication group (p < 0.001). When adjusting for confound, there was no association when the growth on the second stage was the same as the first (odd ratio (OR) 2.50, 95% confidence interval (CI) 0.49 to 12.50; p = 0.269); however, when a different organism was identified at the second stage, this was independently associated with failure of treatment (OR 8.40, 95% CI 2.91 to 24.39; p < 0.001). There were no other significant differences between the two cohorts with regard to patient demographics or type of organisms isolated. Conclusion. Change in the identified microorganism between first- and second-stage revision for PJI was associated with failure of management. Identification of this change in the microorganism prior to commencement of the second stage may help target antibiotic management and could improve the success of surgery in these patients. Cite this article: Bone Jt Open 2023;4(9):720–727


Bone & Joint Open
Vol. 4, Issue 8 | Pages 621 - 627
22 Aug 2023
Fishley WG Paice S Iqbal H Mowat S Kalson NS Reed M Partington P Petheram TG

Aims. The rate of day-case total knee arthroplasty (TKA) in the UK is currently approximately 0.5%. Reducing length of stay allows orthopaedic providers to improve efficiency, increase operative throughput, and tackle the rising demand for joint arthroplasty surgery and the COVID-19-related backlog. Here, we report safe delivery of day-case TKA in an NHS trust via inpatient wards with no additional resources. Methods. Day-case TKAs, defined as patients discharged on the same calendar day as surgery, were retrospectively reviewed with a minimum follow-up of six months. Analysis of hospital and primary care records was performed to determine readmission and reattendance rates. Telephone interviews were conducted to determine patient satisfaction. Results. Since 2016, 301/7350 TKAs (4.1%) in 290 patients at our institution were discharged on the day of surgery. Mean follow-up was 31.4 months (6.2 to 70.0). In all, 28 patients (9.3%) attended the emergency department or other acute care settings within 90 days of surgery, most often with wound concerns or leg swelling; six patients (2.0%) were readmitted. No patients underwent a subsequent revision procedure, and there were no periprosthetic infections. Two patients (0.7%) underwent secondary patella resurfacing, and one patient underwent arthroscopic arthrolysis after previous manipulation under anaesthetic (MUA). Three patients (1.0%) underwent MUA alone. Primary care consultation records, available for 206 patients, showed 16 patients (7.8%) contacted their general practitioner within two weeks postoperatively; two (1.0%) were referred to secondary care. Overall, 115/121 patients (95%) telephoned stated they would have day-case TKA again. Conclusion. Day-case TKA can be safely delivered in the NHS with no additional resources. We found low incidence of contact with primary and secondary care in the postoperative period, and high patient satisfaction. Cite this article: Bone Jt Open 2023;4(8):621–627


Bone & Joint Open
Vol. 3, Issue 11 | Pages 885 - 893
14 Nov 2022
Goshima K Sawaguchi T Horii T Shigemoto K Iwai S

Aims. To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO). Methods. Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of gap filling was evaluated using anteroposterior radiographs at six weeks and three, six, and 12 months postoperatively. Results. The pain VAS and JOA scores significantly improved after OWHTO in both groups. Although the LIPUS group had better pain scores at six weeks and three months postoperatively, there were no significant differences in JOA score between the groups. The lateral hinge united at six weeks postoperatively in 34 (75.6%) knees in the control group and in 33 (73.3%) knees in the LIPUS group. The progression rates of gap filling in the LIPUS group were 8.0%, 15.0%, 27.2%, and 46.0% at six weeks and three, six, and 12 months postoperatively, respectively, whereas in the control group at the same time points they were 7.7%, 15.2%, 26.3%, and 44.0%, respectively. There were no significant differences in the progression rate of gap filling between the groups. Conclusion. The present study demonstrated that LIPUS did not promote bone healing and functional recovery after OWHTO with a locking plate. The routine use of LIPUS after OWHTO was not recommended from the results of our study. Cite this article: Bone Jt Open 2022;3(11):885–893


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 610 - 621
1 Jun 2023
Prodromidis AD Chloros GD Thivaios GC Sutton PM Pandit H Giannoudis PV Charalambous CP

Aims. Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening. Methods. A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken. Results. Of 263 studies, 12 were included with a total of 3,861 TKAs. Meta-analysis of ten studies showed high rates of overall tibial or femoral RLLs for the cemented original design of the ATTUNE TKA. The overall rate was 21.4% (95% confidence interval (CI) 12.7% to 33.7%) for all types of design but was higher for certain subgroups: 27.4% (95% CI 13.4% to 47.9%) for the cruciate-retaining type, and 29.9% (95% CI 15.6% to 49.6%) for the fixed-bearing type. Meta-analysis of five studies comparing the ATTUNE TKA with other implants showed a significantly higher risk of overall tibial or femoral RLLs (odds ratio (OR) 2.841 (95% CI 1.219 to 6.623); p = 0.016) for the ATTUNE. The rates of loosening or revision for loosening were lower, at 1.2% and 0.9% respectively, but the rates varied from 0% to 16.3%. The registry data did not report specifically on the original ATTUNE TKA or on revision due to loosening, but ‘all-cause’ five-year revision rates for the cemented ATTUNE varied from 2.6% to 5.9%. Conclusion. The original cemented ATTUNE TKA has high rates of RLLs, but their clinical significance is uncertain given the overall low associated rates of loosening and revision. However, in view of the high rates of RLLs and the variation in the rates of loosening and revision between studies and registries, close surveillance of patients who have undergone TKA with the original ATTUNE system is recommended. Cite this article: Bone Joint J 2023;105-B(6):610–621


Bone & Joint Open
Vol. 4, Issue 5 | Pages 393 - 398
25 May 2023
Roof MA Lygrisse K Shichman I Marwin SE Meftah M Schwarzkopf R

Aims. Revision total knee arthroplasty (rTKA) is a technically challenging and costly procedure. It is well-documented that primary TKA (pTKA) have better survivorship than rTKA; however, we were unable to identify any studies explicitly investigating previous rTKA as a risk factor for failure following rTKA. The purpose of this study is to compare the outcomes following rTKA between patients undergoing index rTKA and those who had been previously revised. Methods. This retrospective, observational study reviewed patients who underwent unilateral, aseptic rTKA at an academic orthopaedic speciality hospital between June 2011 and April 2020 with > one-year of follow-up. Patients were dichotomized based on whether this was their first revision procedure or not. Patient demographics, surgical factors, postoperative outcomes, and re-revision rates were compared between the groups. Results. A total of 663 cases were identified (486 index rTKAs and 177 multiply revised TKAs). There were no differences in demographics, rTKA type, or indication for revision. Multiply revised patients had significantly longer rTKA operative times (p < 0.001), and were more likely to be discharged to an acute rehabilitation centre (6.2% vs 4.5%) or skilled nursing facility (29.9% vs 17.5%; p = 0.003). Patients who had been multiply revised were also significantly more likely to have subsequent reoperation (18.1% vs 9.5%; p = 0.004) and re-revision (27.1% vs 18.1%; p = 0.013). The number of previous revisions did not correlate with the number of subsequent reoperations (r = 0.038; p = 0.670) or re-revisions (r = −0.102; p = 0.251). Conclusion. Multiply revised TKA had worse outcomes, with higher rates of facility discharge, longer operative times, and greater reoperation and re-revision rates compared to index rTKA. Cite this article: Bone Jt Open 2023;4(5):393–398


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims. Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. Methods. A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option). Results. Between 2013 and 2016, 352 NexGen TKAs were carried out on 331 patients. A total of 62 TKAs have been revised to date, giving an all-cause revision rate of 17.6% at a minimum of five years. Three of these revisions were due to infection. Overall, 59 of the revisions were performed for aseptic loosening (16.7%) of the tibial component. The tibial component was removed intraoperatively without instrumentation due to significant tibial debonding between the implant-cement interface. Conclusion. While overall, we believe that early aseptic loosening is multi-factorial in nature, the significantly high aseptic revision rate, as seen by an experienced fellowship-trained arthroplasty surgeon, has led us to believe that there is a fundamental issue with this NexGen implant design. Continued implant surveillance and rigorous review across all regions using this particular implant is warranted based on the concerning findings described here. Cite this article: Bone Jt Open 2022;3(6):495–501


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 1 - 1
7 Aug 2023
Scheepers W Held M von Bormann R Wascher D Richter D Schenck R Harner C
Full Access

Abstract. Introduction. Knee dislocations (KDs) are complex injuries which are often associated with damage to surrounding soft tissues or neurovascular structures. A classification system for these injuries should be simple and reproducible and allow communication among surgeons for surgical planning and outcome prediction. The aim of this study was to formulate a list of factors, prioritised by high-volume knee surgeons, that should be included in a KD classification system. Methods. A global panel of orthopaedic knee surgery specialists participated in a Delphi process. A list of factors to be included in a KD classification system was formulated by 91 orthopaedic surgeons, which was subsequently prioritised by 27 experts from 6 countries. The items were analysed to find factors that had at least 70% consensus for inclusion in a classification system. Results. The four factors that reached consensus agreement and thus deemed critical for inclusion in a classification system were vascular injuries (89%), common peroneal nerve injuries (78%), number of torn ligaments (78%), and open injuries (70%). Conclusion. The wide geographic distribution of participants provides diverse insight and makes the results of the study globally applicable. The most important factors to include in a classification system as determined by the Delphi technique were vascular injuries, common peroneal nerve injuries, number of torn ligaments, and open injuries. The Schenck anatomic classification system most accurately identifies these patient variables with the addition of open injuries. The authors propose to update the Schenck classification system with the inclusion of open injuries as an additional modifier


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 34 - 34
7 Aug 2023
Afzal I Radha S Mitchell P
Full Access

Abstract. Multidisciplinary team (MDT) meetings in orthopaedic surgery are evolving. The goals include patient optimisation, surgical planning and discharge arrangements, individually on a patient specific basis. In line with British Association Surgery of the Knee and GIRFT guidelines, we report our regional experience on the implementation and evolution of our regional Revision Knee Arthroplasty MDT. We undertook a retrospective review of the process, cases discussed and quality assurance conducted in the weekly MDT. Since implementation of the MDT meeting in January 2019, 550 patients with painful joint replacements have been discussed. In May 2021, we formalised our ‘terms of reference’ and ‘standard operating procedures’ which are adhered to by the consultants operating within the network, all of whom attend the meeting. A proforma has been developed and is completed for all cases capturing all pertinent information. All cases are graded according to R1, R2, or R3 complexity scale. Since its inception, the MDT has looked at all post-operative imaging, we now describe a new classification system for grading the appearances. Confirmation of the pre-operative plan and actual surgical intervention is reviewed and audited. In addition, confirmation of indication of revision at the time of operation is reviewed and validated for accuracy with benefits to the unit, individual surgeon and the NJR. In conclusion, the implementation of the revision MDT facilitating pre-operative revision arthroplasty discussion and post-operative quality assurance processes enable surgeons to educate, reflect on their practice and ensure that the highest standards of care are being provided


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 613 - 619
2 May 2022
Ackerman IN Busija L Lorimer M de Steiger R Graves SE

Aims. This study aimed to describe the use of revision knee arthroplasty in Australia and examine changes in lifetime risk over a decade. Methods. De-identified individual-level data on all revision knee arthroplasties performed in Australia from 2007 to 2017 were obtained from the Australian Orthopaedic Association National Joint Replacement Registry. Population data and life tables were obtained from the Australian Bureau of Statistics. The lifetime risk of revision surgery was calculated for each year using a standardized formula. Separate calculations were undertaken for males and females. Results. In total, 43,188 revision knee arthroplasty procedures were performed in Australia during the study period, with a median age at surgery of 69 years (interquartile range (IQR) 62 to 76). In 2017, revision knee arthroplasty rates were highest for males aged 70 to 79 years (102.9 procedures per 100,000 population). Lifetime risk of revision knee arthroplasty for females increased slightly from 1.61% (95% confidence interval (CI) 1.53% to 1.69%) in 2007 to 2.22% (95% CI 2.13% to 2.31%) in 2017. A similar pattern was evident for males, with a lifetime risk of 1.43% (95% CI 1.36% to 1.51%) in 2007 and 2.02% (95% CI 1.93% to 2.11%) in 2017. A decline in procedures performed for loosening/lysis (from 41% in 2007 to 24% in 2017) and pain (from 14% to 9%) was evident, while infection became an increasingly common indication (from 19% in 2007 to 29% in 2017). Conclusion. Well-validated national registry data can help us understand the epidemiology of revision knee arthroplasty, including changing clinical indications. Despite a small increase over a decade, the lifetime risk of revision knee arthroplasty in Australia is low at one in 45 females and one in 50 males. These methods offer a population-level approach to quantifying revision burden that can be used for ongoing national surveillance and between-country comparisons. Cite this article: Bone Joint J 2022;104-B(5):613–619


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 58 - 58
7 Aug 2023
Saghir R Watson K Martin A Cohen A Newman J Rajput V
Full Access

Abstract. Introduction. Knee arthroscopy can be used for ligamentous repair, reconstruction and to reduce burden of infection. Understanding and feeling confident with knee arthroscopy is therefore a highly important skillset for the orthopaedic surgeon. However, with limited training or experience, furthered by reduced practical education due to COVID-19, this skill can be under-developed amongst trainee surgeons. Methods. At a single institution, ten junior doctors (FY1 to CT2), were recruited as a part of a five, two-hour session, training programme utilising the Simbionix® ARTHRO Mentor knee arthroscopy simulator, supplemented alongside educational guidance with a consultant orthopaedic knee surgeon. All students had minimal to no levels of prior arthroscopic experience. Exercises completed included maintaining steadiness, image centering and orientation, probe triangulation, arthroscopic knee examination, removal of loose bodies, and meniscectomy. Pre and post-experience questionnaires and quantitative repeat analysis on simulation exercises were undertaken to identify levels of improvement. Results. Comparing pre and post-experience questionnaires significant improvements in levels of confidence were noted in the following domains: naming arthroscopic instruments, port positioning and insertion, recognising normal anatomy arthroscopically, holding and using arthroscopic instruments and assisting in a live theatre setting (p<0.05). Significant improvements were noted in time taken to complete, distance covered in metres and roughness of instruments used on the simulated exercises on repeat performance (p<0.05). Conclusion. With only five sessions under senior guidance, using a simulator such as the ARTHRO Mentor, significant improvements in both levels of confidence and skill can be developed even among individuals with no prior experience