Advertisement for orthosearch.org.uk
Results 1 - 20 of 27
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 96 - 96
11 Apr 2023
Crippa Orlandi N De Sensi A Cacioppo M Saviori M Giacchè T Cazzola A Mondanelli N Giannotti S
Full Access

The computational modelling and 3D technology are finding more and more applications in the medical field. Orthopedic surgery is one of the specialties that can benefit the most from this solution. Three case reports drawn from the experience of the authors’ Orthopedic Clinic are illustraded to highlight the benefits of applying this technology. Drawing on the extensive experience gained within the authors’ Operating Unit, three cases regarding different body segments have been selected to prove the importance of 3D technology in preoperative planning and during the surgery. A sternal transplant by allograft from a cryopreserved cadaver, the realization of a custom made implant of the glenoid component in a two-stage revision of a reverse shoulder arthroplasty, and a case of revision on a hip prosthesis with acetabular bone loss (Paprosky 3B) treated with custom system. In all cases the surgery was planned using 3D processing software and models of the affected bone segments, printed by 3D printer, and based on CT scans of the patients. The surgical implant was managed with dedicated instruments. The use of 3D technology can improve the results of orthopedic surgery in many ways: by optimizing the outcomes of the operation as it allows a preliminary study of the bone loss and an evalutation of feasibility of the surgery, it improves the precision of the positioning of the implant, especially in the context of severe deformity and bone loss, and it reduces the operating time; by improving surgeon training; by increasing patient involvement in decision making and informed consent. 3D technology, by offering targeted and customized solutions, is a valid tool to obtain the tailored care that every patient needs and deserves, also providing the surgeon with an important help in cases of great complexity


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 19 - 19
1 Nov 2021
Ghaffari A J⊘rgensen M R⊘mer H S⊘ensen M Kold S Rahbek O Bisgaard J
Full Access

Introduction and Objective. Continuous peripheral nerve blocks (cPNBs) have shown good results in pain management after orthopedic surgeries. However, the variation of performance between different subspecialities is unknown. The aim of this study is to describe our experience with cPNBs after lower limb orthopedic surgeries in different subspecialties. Materials and Methods. This prospective cohort study was performed on collected data from cPNBs after orthopedic surgeries in lower limbs. Catheters were placed by experienced anesthesiologists using sterile technique. After catheterization, the patients were examined daily, by specially educated acute pain service nurses. The characteristics of the patients, duration of catheterization, severity of the post-operative pain, need for additional opioids, and possible complications were registered. Results. We included 246 patients (=547 catheters). 115 (21%) femoral, 162 (30%) saphenous, 66 (12%) sciatic, and 204 (37%) popliteal sciatic nerve catheter were used. The median duration of a catheter was 3 days [IQR = 2 – 5]. The proportion of femoral, sciatic, saphenous, and popliteal nerve catheters with duration of more than two days was 81%, 79%, 73%, and 71% for, respectively. This proportion varied also between different subspecialties. 91% of the catheters remained in place for more than two days in amputations (n=56), 89% in pediatric surgery (n=79), 76% in trauma (n=217), 64% in foot and ankle surgery (n=129), and 59% in limb reconstructive surgery (n=66). The proportion of pain-free patients were 77 – 95% at rest, 63 – 88% at mobilization. 79 – 92% did not need increased opioid doses, and 50 – 67% did not require PRN opioid. 443 catheters (81%) were removed as planned. The cause of unplanned catheter removal was loss of efficacy in 69 (13%), dislodgement in 23 (4.2%), leakage in 8 (1.5%), and erythema in 4 catheters (0.73%). No major complication occurred. Conclusions. 81% of catheters remained in place until planned removal and opioid usage after surgery was lower than expected. Catheters were efficient in both adult and pediatric surgery; however, a variation was seen between orthopaedic subspecialities regarding duration of nerve catheter usage


Full Access

To date, few studies have investigated the feasibility of the loop-mediated isothermal amplification (LAMP) assay for identifying pathogens in tissue samples. This study aimed to investigate the feasibility of LAMP for the rapid detection of methicillin-susceptible or methicillin-resistant Staphylococcus aureus (MSSA or MRSA) in tissue samples, using a bead-beating DNA extraction method. Twenty tissue samples infected with either MSSA (n = 10) or MRSA (n = 10) were obtained from patients who underwent orthopedic surgery for suspected musculoskeletal infection between December 2019 and September 2020. DNA was extracted from the infected tissue samples using the bead-beating method. A multiplex LAMP assay was conducted to identify MSSA and MRSA infections. To recognize the Staphylococcus genus, S. aureus, and methicillin resistance, 3 sets of 6 primers for the 16S ribosomal ribonucleic acid (rRNA) and the femA and mecA genes were used, respectively. The limit of detection and sensitivity (detection rate) of the LAMP assay for diagnosing MSSA and MRSA infection were analyzed. The results of this study suggest that the LAMP assay performed with tissue DNA samples can be a useful diagnostic method for the rapid detection of musculoskeletal infections caused by MSSA and MRSA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 137 - 137
2 Jan 2024
Ghaffari A Lauritsen RK Christensen M Thomsen T Mahapatra H Heck R Kold S Rahbek O
Full Access

Smartphones are often equipped with inertial sensors capable of measuring individuals' physical activities. Their role in monitoring the patients' physical activities in telemedicine, however, needs to be explored. The main objective of this study was to explore the correlation between a participant's daily step counts and the daily step counts reported by their smartphone. This prospective observational study was conducted on patients undergoing lower limb orthopedic surgery and a group of non-patients. The data collection period was from 2 weeks before until four weeks after the surgery for the patients and two weeks for the non-patients. The participants' daily steps were recorded by physical activity trackers employed 24/7, and an application recorded the number of daily steps registered by the participants' smartphones. We compared the cross-correlation between the daily steps time-series taken from the smartphones and physical activity trackers in different groups of participants. We also employed mixed modeling to estimate the total number of steps. Overall, 1067 days of data were collected from 21 patients (11 females) and 10 non-patients (6 females). The cross-correlation coefficient between the smartphone and physical activity tracker was 0.70 [0.53–0.83]. The correlation in the non-patients was slightly higher than in the patients (0.74 [0.60–0.90] and 0.69 [0.52–0.81], respectively). Considering the ubiquity, convenience, and practicality of smartphones, the high correlation between the smartphones and the total daily step time-series highlights the potential usefulness of smartphones in detecting the change in the step counts in remote monitoring of the patient's physical activity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 146 - 146
11 Apr 2023
Sneddon F Fritsch N Skipsey D Mackenzie S Rankin I
Full Access

The Royal College of Surgeons of England (RCS) Good Surgical Practice guidance identifies essential criteria for surgical operation note documentation. The current quality improvement project aims to identify if using pre-templated operation notes for documenting fractured neck of femur surgery results in improved documentation when compared to free hand orthopaedic operation notes. A total of fourteen categories were identified from the RCS guidance as required across all the operations identified in this study. All operations for the month of October 2021 were identified and the operation notes analysed. Pre-templated operation notes were compared to free hand operation notes. 97 cases were identified, of which 74 were free hand operation notes and 23 were pre-templated fractured neck of femur operation notes. All fourteen categories were completed in 13 (57%) of the templated operation notes vs 0 (0%) in the free hand operation notes (odds ratio 0.0052, 95% CI 0.0003 to 0.0945, p < 0.001). The median total number of completed categories was significantly higher in the templated op-note group compared to the free hand op-note group (templated median 14, range 12-14, vs. free hand median 11, range 9 to 13, p < 0.001). Logistic regression analysis of operation notes written by Registrars or Consultants identified Registrars as more likely to document the antibiotic prophylaxis given (p = 0.025). Use of pre-templated operation notes results in significantly improved documentation. Adoption of generic pre-templated operation notes to improve surgical documentation should be considered across all operations


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 1 - 1
1 Dec 2022
Parchi P
Full Access

In the last years, 3d printing has progressively grown and it has reached a solid role in clinical practice. The main applications brought by 3d printing in orthopedic surgery are: preoperative planning, custom-made surgical guides, custom-made im- plants, surgical simulation, and bioprinting. The replica of the patient's anatomy, starting from the elaboration of medical volumetric images (CT, MRI, etc.), allows a progressive extremization of treatment personalization that could be tailored for every single patient. In complex cases, the generation of a 3d model of the patient's anatomy allows the surgeons to better understand the case — they can almost “touch the anatomy” —, to perform a more ac- curate preoperative planning and, in some cases, to perform device positioning before going to the surgical room (i.e. joint arthroplasty). 3d printing is also commonly used to produce surgical cutting guides, these guides are positioned intraoperatively on given landmarks to guide the surgeon to perform a specific surgical act (bone osteotomy, bone resection, implant position, etc.). In total knee arthroplasty, custom-made cutting guides have been developed to help the surgeon align the femoral and tibial components to the pre-arthritic condition with- out the use of the intramedullary femoral guide. 3d printed custom-made implants represent an emerging alternative to biological reconstructions especially after oncologic resection surgery or in case of complex arthroplasty revision surgery. Custom-made implants are designed to re- place the original shape and size of the patient's bone and they allow an extreme personalization of the treatment for every single patient. Patient-specific surgical simulation is a new frontier that promises great benefits for surgical training. a solid 3d model of the patient's anatomy can faithfully reproduce the surgical complexity of the patient and it allows to generate surgical simulators with increasing difficulty to adapt the difficulties of the course with the level of the trainees performing structured training paths: from the “simple” case to the “complex” case


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 21 - 21
2 Jan 2024
Harting H Polyak A Angrisani N Herrmann T Ehlert N Meißner J Willmann M Al-Bazaz S Ross T Bankstahl J Reifenrath J
Full Access

In orthopedic surgery, implant infections are a serious issue and difficult to treat. The aim of this study was to use superparamagnetic nanoporous silica nanoparticles (MNPSNP) as candidates for directed drug delivery. Currently, short blood circulation half-life due to interactions with the host's immune system hinder nanoparticles in general from being clinically used. PEGylation is an approach to reduce these interactions and to enhance blood circulation time. The effect of PEGylation of the used . 68. Ga-labelled MNPSNP on the distribution and implant accumulation was examined by PET/CT imaging and gamma counting in an implant mouse model. Female Balb/c mice (n=24) received a magnetic implant subcutaneously on the left and a titanium implant on the right hind leg. On day one, 12 of these mice received an additional clodronate®-injection for macrophage depletion. On the second postoperative day, mice were anaesthetized and MNPSNP (native or PEGylated) injected intravenously, followed by a dynamic PET-scan over 60 minutes, a CT- and a static PET-scan at 120 min. As control, 12 mice received only . 68. Ga-MNPSNP (native or PEGylated). Gamma counting of inner organs, urine, blood and implant area was performed as further final analysis. Although PEGylation of the nanoparticles already resulted in lower liver uptakes, both variants of . 68. Ga-labeled MNPSNP accumulated in liver and spleen. Combination of PEGylation with clodronate®-injection led to a highly significant effect whereas clodronate®-injection alone could not reveal significant differences. In gamma counting, a significantly higher %I.D./g was found for the tissue surrounding the magnetic implants compared to the titanium control, although in a low range. PEGylation and/or clodronate®-injection revealed no significant differences regarding nanoparticle accumulation at the implantation site. PEGylation increases circulation time, but MNPSNP accumulation at the implant site was still insufficient for treatment of infections. Additional efforts have to further increase circulation time and local accumulation. Acknowledgements: This work is funded by the German Research Foundation (DFG, project number 280642759)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 32 - 32
1 Dec 2022
Ricci A Boriani L Giannone S Aiello V Marvasi G Toccaceli L Rame P Moscato G D'Andrea A De Benedetto S Frugiuele J Vommaro F Gasbarrini A
Full Access

Scoliosis correction surgery is one of the longest and most complex procedures of all orthopedic surgery. The complication rate is therefore not negligible and is particularly high when the surgery is performed in patients with neuromuscular or connective tissue disease or complex genetic syndromes. In fact, these patients have various comorbidities and organ deficits (respiratory capacity, swallowing / nutrition, heart function, etc.), which can compromise the outcome of the surgery. In these cases, an accurate assessment and preparation for surgery is essential, also making use of external consultants. To make this phase simpler, more effective and homogeneous, a multidisciplinary path of peri-operative optimization is being developed in our Institute, which also includes the possibility of post-operative hospitalization for rehabilitation and recovery. The goal is to improve the basic functional status as much as possible, in order to ensure faster functional recovery and minimize the incidence of peri-operative complications, to be assessed by clinical audit. The path model and the preliminary results on the first patients managed according to the new modality are presented here. The multidisciplinary path involves the execution of the following assessments / interventions: • Pediatric visit with particular attention to the state of the upper airways and the evaluation of chronic or frequent inflammatory states • Cardiological Consultation with Echocardiogram. • Respiratory Function Tests, Blood Gas Analysis and Pneumological Consultation to evaluate indications for preoperative respiratory physiotherapy cycles, Non-Invasive Ventilation (NIV) cycles, Cough Machine. Possible Polysomnography. • Nutrition consultancy to assess the need for nutritional preparation in order to improve muscle trophism. • Consultation of the speech therapist in cases of dysphagia for liquids and / or solids. • Electroencephalogram and Neurological Consultation in epileptic patients. • Physiological consultation in patients already being treated with a cough machine and / or NIV. • Availability of postoperative hospitalization in the rehabilitation center (with skills in respiratory and neurological rehabilitation) for the most complex cases. When all the appropriate assessments have been completed, the anesthetist in charge at our Institute examines the clinical documentation and establishes whether the path can be considered complete and whether the patient is ready for surgery. At the end of the surgery, the patient is admitted to the Post-operative Intensive Care Unit of the Institute. If necessary, a new program of postoperative rehabilitation (respiratory, neuromotor, etc.) is programmed in a specialist reference center. To date, two patients have been referred to the preoperative optimization path: one with Ullrich Congenital Muscular Dystrophy, and one with 6q25 Microdeletion Syndrome. In the first case, the surgery was performed successfully, and the patient was discharged at home. In the second case, after completing the optimization process, the surgery was postponed due to the finding of urethral malformation with the impossibility of bladder catheterization, which made it necessary to proceed with urological surgery first. The preliminary case series presented here is still very limited and does not allow evaluations on the impact of the program on the clinical practice and the complication rate. However, these first experiences made it possible to demonstrate the feasibility of this complex multidisciplinary path in which a network of specialists takes part


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 92 - 92
1 Dec 2020
Hanberg P Bue M Kabel J J⊘rgensen AR Jessen C S⊘balle K Stilling M
Full Access

Tourniquet is widely used in orthopedic surgery to reduce intraoperative bleeding and improve visualization. We evaluated the effect of tourniquet application on both peri- and postoperative cefuroxime concentrations in subcutaneous tissue, skeletal muscle, calcaneal cancellous bone, and plasma. The primary endpoint was the time for which the free drug concentration of cefuroxime was maintained above the clinical breakpoint minimal inhibitory concentration (T>MIC) forStaphylococcus aureus (4 µg/mL). Ten patients scheduled for hallux valgus or hallux rigidus surgery were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in subcutaneous tissue, skeletal muscle, and calcaneal cancellous bone. A tourniquet was applied on the thigh of the leg scheduled for surgery. Cefuroxime (1.5 g) was administered intravenously as a bolus 15 minutes prior to tourniquet inflation, followed by a second dose 6 hours later. The mean tourniquet duration (range) was 65 (58; 77) minutes. Dialysates and venous blood samples were collected for 12 hours. For cefuroxime the T>MIC (4 μg/mL) ranged between 4.8–5.4 hours across compartments, with similar results for the tourniquet and non-tourniquet leg. Comparable T>MIC and penetration ratios were found for the first and second dosing intervals. We concluded that administration of cefuroxime (1.5 g) 15 minutes prior to tourniquet inflation is safe in order to achieve tissue concentrations above 4 µg/mL throughout surgery. A tourniquet application time of approximately 1 hour did not affect the cefuroxime tissue penetration in the following dosing interval


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 23 - 23
1 Dec 2020
MERTER A
Full Access

With the increase in the elderly population, there is a dramatic increase in the number of spinal fusions. Spinal fusion is usually performed in cases of primary instability. However it is also performed to prevent iatrogenic instability created during surgical treatment of spinal stenosis in most cases. In literature, up to 75% of adjacent segment disease (ASD) can be seen according to the follow-up time. 1. Although ASD manifests itself with pathologies such as instability, foraminal stenosis, disc herniation or central stenosis. 1,2. There are several reports in the literature regarding lumbar percutaneous transforaminal endoscopic interventions for lumbar foraminal stenosis or disc herniations. However, to the best our knowledge, there is no report about the treatment of central stenosis in ASD. In this study, we aimed to investigate the short-term results of unilateral biportal endoscopic decompressive laminotomy (UBEDL) technique in ASD cases with symptomatic central or lateral recess stenosis. The number of patients participating in the prospective study was 8. The mean follow-up was 6.9 (ranged 6 to 11) months. The mean age of the patients was 68 (5m, 3F). The development of ASD time after fusion was 30.6 months(ranged 19 to 42). Mean fused segments were 3 (ranged 2 to 8). Preoperative instability was present in 2 of the patients which was proven by dynamic lumbar x-rays. Preoperative mean VAS-back score was 7.8, VAS Leg score was 5.6. The preoperative mean JOA (Japanese Orthopaedic Association) score was 11.25. At 6th month follow-up, the mean VAS back score of the patients was 1, and the VAS leg score was 0.5. This improvement was statistically significant (p = 0.11 and 0.016, respectively). The mean JOA score at the 6th month was 22.6 and it was also statistically significant comparing preoperative JOA score(p = 0.011). The preoperative mean dural sac area measured in MR was 0.50 cm2, and it was measured as 2.1 cm. 2. at po 6 months.(p = 0.012). There was no progress in any patient's instability during follow-up. In orthopedic surgery, when implant related problems develop in any region of body (pseudoarthrosis, infection, adjacent fracture, etc.), it is generally treated by using more implants in its final operation. This approach is also widely used in spinal surgery. 3. However, it carries more risk in terms of devoloping ASD, infection or another complications. In the literature, endoscopic procedures have almost always been used in the treatment of ventral pathologies which constitute only 10%. In ASD, disease devolops as characterized by wide facet joint arthrosis and hypertrophied ligamentum flavum in the cranial segment and it is mostly presented both lateral recess and santal stenosis symptoms (39%). In this study, we found that UBEDL provides successful results in the treatment of patients without no more muscle and ligament damage in ASD cases with spinal stenosis. One of the most important advantages of UBE is its ability to access both ventral and dorsal pathologies by minimally invasive endoscopic aproach. I think endoscopic decompression also plays an important role in the absence of additional instability at postoperatively in patients. UBE which has already been described in the literature given successful results in most of the spinal degenerative diseases besides it can also be used in the treatment of ASD. Studies with longer follow-up and higher patient numbers will provide more accurate results


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 130 - 130
1 Nov 2018
Leeuwenburgh S
Full Access

Calcium phosphate ceramics and bioactive glasses are frequently used in orthopedic surgery to stimulate the regeneration of bone tissue due to their superior compatibility to bone tissue. Nevertheless, the brittleness and lack of self-healing behavior of bioceramics are still considered as serious drawbacks. Therefore, these bioceramics have been combined with organic biomaterials for several decades. Since the 1990s, the emergence of nanotechnology has accelerated the progress with respect to the development of organic-inorganic nanocomposites of improved functionality compared to conventional composite biomaterials. This presentation focuses on the development of injectable (nano)composites with self-healing and/or load-bearing capacity. To this end, the affinity between polymeric and inorganic components was tuned by modifying non-covalent interactions between both composite components. Specifically, we exploited reversible interactions between hydrogel matrices and inorganic nanoparticles (traditional nanocomposites), hydrogel nanoparticles and inorganic nanoparticles (colloidal nanocomposites), as well as fibers and bioceramic matrices (fiber-reinforced cement composites). The resulting composite biomaterials were mechanically strong and self-healing, which may open up new avenues of research on the applicability of self-healing and load-bearing composite biomaterials for regenerative medicine


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 61 - 61
1 Nov 2018
Reifenrath J Schröder ML Fedeeva E Calliess T Angrisani N
Full Access

Implant infection is an increasing problem in orthopedic surgery, especially due to progressive antibiotic resistance and an aging population with rising numbers of implantations. As a consequence, new strategies for infection prevention are necessary. In the previous study it was hypothesized that laser-structured implant surfaces favor cellular adhesion while hindering bacterial ongrowth and therewith contribute to reduce implant infections. Cuboid titanium implants (0.8 × 0.8 × 12 mm. 3. , n=34) were used. Seventeen were laser-structured by ultra-short pulsed laser ablation to create a spike structure; the others were polished and served as controls. In general anesthesia, implants were inserted in rat tibiae and infected with a S. aureus suspension. During a 21 day postoperative follow-up, daily clinical control was performed. Radiographs were taken at day 14 and day 21. After euthanasia, bacterial load and biofilm formation on the implant surface was evaluated semi quantitatively by confocal laser scanning microscopy and computational acquisition of bacteria and cells by Imaris®-software. Additionally, histology of the surrounding bone was performed. Clinically, no differences were observed between the groups. However, contrary to our hypothesis, bacterial load was increased in the laser-structured implant group although cellular adhesion was even more pronounced. Radiographical and histological evaluations showed increased bone alterations in the group with laser-structured implants compared to the control group. These findings did not confirm prior in vitro studies, where a reduction of bacterial load was found for similar surfaces and demonstrate the necessity of in vivo trials prior to the clinical use of new materials


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 2 - 2
1 Jan 2019
Boughton O Yan L Ma S Hansen U Giuliani F Cobb J Marrow J Abel R
Full Access

With information about a patient's bone mechanical properties orthopaedic operations could be optimised to reduce intra- and post-operative complications. However, there is currently no reliable method of measuring a patient's bone mechanical properties in vivo. We have previously investigated microindentation, using a 1.5mm diameter spherical indenter tip, and found no correlation between these measurements and compression testing measurements. We hypothesised that by using a larger diameter indenter tip we would closer match bone millimetre-scale mechanical properties. 20 bone samples were taken from 20 patients undergoing hip replacement surgery. The samples were machined from the femoral neck calcar cortical bone into 6×3×3mm parallelepiped specimens, aligned with the osteons along the long axis. The samples were micro-computed tomography (CT) scanned to calculate porosity. Microindentation was performed using a 6mm diameter, sapphire, spherical indenter tip. 12 indentations were performed in a grid and the reduced moduli were calculated using the Oliver-Pharr method. Compression testing was then performed to failure and the apparent elastic modulus was calculated for each sample. A moderate correlation was found between the indentation reduced moduli and compression testing elastic moduli (r=0.52, r2=0.275, p=0.018). In addition, a moderate correlation was found between the indentation reduced moduli and CT-measured porosity (r=0.5, r2=0.251, p=0.025) and a strong correlation was found between compression testing moduli and porosity (r=0.75, r2=0.568, p<0.001). Using large-tip spherical microindentation, indentation reduced moduli correlated significantly with compression testing apparent elastic moduli in these 20 cortical bone specimens. Microindentation using a large, spherical indenter tip may predict the mechanical properties of bone at the millimetre length scale and shows promise as a potential future clinical decision aid in surgery


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 120 - 120
1 Nov 2018
Tomoyama A Kobayashi N Inaba Y Choe1 H Ike H Kobayashi D Watanabe S Higashihira S Yamazaki E Saito T
Full Access

Infection is one of the most serious complications of orthopedic surgery, particularly in implant-related procedures. Minimum inhibitory concentration (MIC) for identified bacteria is an important factor for successful antibiotic treatment. We investigated the MIC of antibiotics in Staphylococcus species from orthopedic infections, comparing with isolates from respiratory medicine. Staphylococcus species isolated in our laboratory from January 2013 to July 2016 were retrospectively reviewed. The MIC of vancomycin (VCM), arbekacin (ABK), teicoplanin (TEIC), linezolid (LZD), and rifampicin (RFP) was reviewed. Differences in the MIC of each antibiotic in orthopedic and respiratory samples were determined. A total of 259 isolates were evaluated (89 orthopedic, 170 respiratory). Staphylococcus aureus was the most commonly identified species (58%). In comparison with orthopedic samples, the number of isolates with a VCM MIC <0.5 μg/ml in methicillin sensitive staphylococcus aureus (MSSA) was significantly higher in respiratory isolates, while a MIC of 2 μg/ml was significantly lower (P = 0.0078). The proportion of isolates with a VCM MIC of 2 μg/ml in methicillin-resistant coagulase-negative staphylococci (MRCNS) was significantly higher in orthopedic isolates than that seen in respiratory isolates of methicillin-resistant staphylococcus aureus (MRSA; P < 0.001). When comparing MRCNS and other orthopedic Staphylococci, the rate of RFP MIC >2 μg/ml in MRCNS isolates was significantly higher (P = 0.0058). The MIC of VCM in Staphylococcus species from orthopedic infection was higher than that of respiratory samples, particularly in MRCNS from implant-related samples. MRCNS showed a significantly higher rate of resistance for RFP versus other orthopedic isolates


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 18 - 18
1 Nov 2018
Kazum E Dolkart O Rozental Y Sherman H Amar E Salai M Maman E Chechik O
Full Access

Drilling through bone is a complex action that requires precise motor skills of an orthopedic surgeon. In order to minimize plunging and soft tissue damage, the surgeon must halt drill progression precisely following penetration of the far cortex. The purpose of this study was to create a low-cost and easy-to-use drilling simulator to train orthopedic residents in reducing the drill plunging depth. This prospective observational study was performed in the division of orthopedic surgery of a single tertiary medical center. The participants included 13 residents and 7 orthopedic specialists. The simulator consisted of a synthetic femur bone model and ordinary modeling clay, and the training unit consisted of a disposable plastic tube (∼US$14), clamps (∼US$58) and a power drill + drill bit (standard hospital equipment). Plunging depths were measured by the simulator and compared between orthopedic specialists, the 6 “senior residents” (3+ years) and the 7 “junior residents” during a training session. Measurements were taken again 2 weeks following the training session. Initially, the plunging depths of the junior residents were significantly greater compared to those of the orthopedic specialists (7.00 mm vs 5.28 mm, respectively, p < 0.038). There was no similarly significant difference between the senior residents and the orthopedic experts ([6.33 mm vs. 5.28 mm, respectively; p = 0.18). The senior residents achieved plunging depths of 5.17 mm at the end of the training session and 4.7 mm 2 weeks later compared to 7.14 mm at the end of the training session and 6 mm 2 weeks later for the junior residents. This study demonstrated the capability of a low-cost drilling simulator as a training model for reducing the plunging depth during the drilling of bone and soft tissue among junior and senior residents


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 3 - 3
1 Apr 2018
Trieb K
Full Access

Introduction. Today TKR is considered one of the most successful operative procedures in orthopedic surgery. Nevertheless, failure rates of 2 – 10% depending on the length of the study and the design are still reported. This provides evidence for further development in knee arthroplasty. Particularly the oxide ceramics used now in THA show major advantages due to their excellent tribological properties, their significantly reduced third-body wear as well as their high corrosion resistance. A further advantage of ceramic materials is their potential use in patients with metal allergy. Metallic wear induces immunological reactions resulting in hypersensitivity, pain, osteolysis and implant loosening. The purpose of our study was to examine the safety of the tibial component of a novel all-ceramic TKR. Materials and Methods. We tested the tibial components of the primary knee implant BPK-S Integration Ceramic. Both the tibial and the femoral component consist of BIOLOX®delta ceramic The standards ISO 14879-1 and ASTM F1800-07 describe the test set-up for the experimental fatigue strength testing of tibial components from knee implants. We conducted the testing with a significantly increased maximum load of 5,300 N (900 N are required). A final burst strength test was carried out after the fatigue load testing in the same embedding and with the same test set-up. Results. No specimen failed during fatigue load testing. The subsequent post-fatigue burst strength testing showed a maximum strength against fracture of at least 9.7 kN for size 3 and at least 12.1 kN for size 6. Discussion. The good results of the strength testing of the tibial component of the BPK-S Integration Ceramic tibial plateau supported the good initial clinical outcome without any implant specific complications of this knee design. Further clinical studies have to show if this design fulfills the high expectations over long periods of time


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 58 - 58
1 Apr 2018
Hansen C Melgaard D
Full Access

Background. Lack of ability in basic mobility skills is associated with increased mortality in patients with hip fractures. The aim of this study was to identify predictors for performing basic mobility skills at discharge. Methods. From June 2015 to May 2016, 235 consecutive patients (76% female, median age 85 (78–89 IQR)) with hip fractures admitted to the Department of Orthopedic Surgery at North Denmark Regional Hospital were included. Basic mobility was assessed at discharge using the Cumulated Ambulation Score (CAS), which consists of 1) getting in and out of bed, 2) rising from a chair and 3) walking. Possible scores for each task is: unable (CAS=0), supported (CAS=1) or independent (CAS=2). A total score of 6 indicates independence in basic mobility. Inclusion was restricted to first time hip fractures and age ≥65. Exclusion criteria were death during admission or unrecorded CAS at discharge. Results. Before surgery 90.6% were independent in basic mobility (CAS=6). Getting out of bed at discharge: independently 37.5%, supported 56.5% and unable 6.0%. Rising from a chair: independently 49.8%, supported 43% and unable 7.2%. Walking: independently 43.8%, supported 38.3% and unable 17.9%. A total of 79 (33.6%) patients achieved independence in all tasks (CAS=6) at discharge. Independence in: 1) getting in and out of bed, 2) rising from a chair, and 3) walking, respectively had significant association with advanced age, length of stay and Charlson Comorbidity Index >0. Medial fractures were associated with inability to rise from a chair. Advanced age was the only variable significantly associated with each task of CAS. Pre-fracture function was associated with the inability to rise from a chair and walking. Delay of surgery > 48 hours after admission was significantly associated with the inability to walk. Conclusion. Elderly patients with comorbidities and dependent pre-fracture function should receive extra attention in rehabilitation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 97 - 97
1 Jan 2017
Erkebulanovich TB Azimovna S Momynovich A Toleuovich E Zhetpisbaevich D Rozmatzhanovich T
Full Access

Bone infection occurring after fractures or orthopedic surgery can progress to the chronic stage and lead to poor results of treatment. Optimal treatment of chronic osteomyelitis are stabilization the fracture, biological recovery of bone defects and destroy bacterial infection. Traditional methods of treatment are systemic administration of antibiotics and surgical treatment of active infection focus. Systemic antibiotics are part of the standard therapy after surgical treatment of infected bone, but their effectiveness is limited due to malnutrition and low absorption at the site of infection. Moreover, long-term treatment and higher doses are associated with serious side effects. The aim of this investigation was to study the results of the complex treatment of patients with chronic osteomyelitis using biodegradable nanomaterials “PerOssal” as antibiotic delivery system. The study was performed at Regional center traumatology and orthopedics, Karaganda, Kazakhstan. A total 20 patient with post-traumatic/post-operative osteomyelitis were included in this open-label, prospective study. Bacteriological examination was taken with the determination of culture and sensitivity test preoperatively, during and postoperatively. After radical surgical debridement and ultrasound cavitation, the bone cavity was full filled with Perosal which can be loaded with different antibiotics depending from the antibiotic sensitivity test. Postoperative wound is completely was sutured. Systemic antibiotic treatment are allowed. The course of infection was monitored by determination leukocyte count and blood sedimentation rate; blood samples were taken befor, 24 hours after surgery, and on days 3, 7, 10, 14. Wound healing was assessed on days 2, 3, 7, 10, and at the time of removal of sutures. Resorption of implanted beads and bone reconstruction were evaluated by X-ray at after operation and at approximately one, three and six months after implantation. A total of 20 patients (mean age 38,1 (26 to 53), 14 male, 6 female) were treated with Perossal pellets (AAP, Germany) from October 2013 to April 2015. Mean leukocyte counts and blood sedimentation rate were within the normal laboratory range and did not indicate infectious complications during the first 21 days after surgery. Primary wound healing occurred in 18 patients and secondary wound healing in two patients. There were two cases of re-infection during the course of the study, one of them related to an incomplete eradication of infected tissue and multidrug-resistant strain occurring during the course of the study, the other is occurred that patient non-compliance. Radiographic analysis six months after surgery showed progressive resorption of the implanted pellets, but only 10 cases have decreasing size of defects on X-ray. This study in adult patients with chronic post-traumatic/post-operative osteomyelitis demonstrated that these biodegradable bone filler pellets which can be loaded with different antibiotics are a clinically useful local antibiotic delivery system and bone substitute which can be used as an alternative to other anti-infective implants. The implantation of the pellets was safety and well tolerated in all patients. This composite can provide adequate protection against bacterial infection during the first weeks after implantation and to support the bone healing process


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 96 - 96
1 Jan 2017
Thorrez L Putzeys G Duportail C Croes K Boudewijns M
Full Access

To prevent infections after orthopedic surgery, intravenous antibiotics are administered perioperatively. Cefazolin is widely used as the prophylactic antibiotic of choice. Systemic antibiotic therapy may however be less effective in longstanding surgery where bone allografts are used. Bone chips have been shown to be an effective carrier for certain types of antibiotics. Bone allografts impregnated with antibiotics may therefore provide the necessary local antibiotic levels for prophylaxis. To be efficient, a prolonged release from these bonechips is required. In contrast to vancomycin, for which prolonged release has clearly been proven effective from Osteomycin®, a commercially available impregnated bone allograft, no prolonged release bone chip preparations have been described so far for cefazolin. We developed a protocol to bind cefazolin in the porous structure of bone chips by means of a hydrogel composed of proteins naturally present in the human body. Three types of bone chips were evaluated: fresh frozen, decellularized frozen and decellularized lyophilized. Bone chips were incubated with 20 mg/ml cefazolin or treated with liquid hydrogel containing either 1 mg/ml fibrin or 1 mg/ml collagen and 20 mg/ml cefazolin. The cefazolin hydrogel was distributed in the porous structure by short vacuum treatment. Bone chips with cefazolin but without hydrogel were either incubated for 20 min- 4h or also treated with vacuum. Cefazolin elution of bone chips was carried out in fetal bovine serum and analyzed by Ultra Performance Liquid Chromatography – Diode Array Detection. Soaking of bone chips without hydrogel resulted in a quick release of cefazolin, which was limited to 4 hours. When vacuum was applied elution of >1 µg/ml cefazolin was measured for up to 36 hours. Combination with collagen hydrogel resulted in a higher cefazolin concentration released at 24 hours (3.9 vs 0.3 µg/ml), but not in a prolonged release. However, combination of decellularized frozen bone chips with fibrin hydrogel resulted in an initial release of 533 µg/ml followed by a gradual decline reaching the minimal inhibitory concentration for S. aureus at 72 hours (1.7 µg/ml), while not measurable anymore after 92 hours. Processed bone chips with hydrogel-cefazolin showed a markedly prolonged cefazolin release. When combined with a fibrin hydrogel, high initial peak levels of cefazolin were obtained, followed by a decreasing release over the following three days. This elution profile is desirable, since high initial levels are important to maximize anti-bacterial action whereas low levels of antibiotic for a limited time may stimulate osteogenesis. It is important that antibiotic release is ending after a few days as prolonged low levels of antibiotics are not clinically helpful and may lead to antibiotic resistance. Further preclinical studies are warranted to show effectiveness of hydrogel-cefazolin impregnated bone chips


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 13 - 13
1 Apr 2015
Augustithis G Huntley J
Full Access

‘Safety’ is at the centre of surgical practice with the aim of minimising the risks of complications and adverse events. Much evidence, based on either retrospective case series or prospective cohorts, concerns the frequency of adverse events. There may be a temptation to describe a procedure as ‘safe’ if no – or few – serious adverse events (the numerator) have occurred out of a number of procedures performed (the denominator). In 1983, Hanley and Lippman-Hand described a simple algorithm to calculate the 95% upper Confidence Interval for data sets in which the numerator is zero (ie series in which there no adverse events). Paediatric orthopaedics suffers from small datasets which may make its researchers especially prone to the erroneous attribution of procedures being ‘safe’. The aim of the current study was to formally assess the evidence on which paediatric orthopaedic surgical procedures are described as ‘safe’. In particular, the objective was to ascertain the proportion of studies describing a procedure as ‘safe’ which achieved a 95% upper limit Confidence Interval of risk of 5% for major adverse events. We examined all papers published by the Journal of Paediatric Orthopaedics in the previous 5 years searching for the single term ‘safe’. 84 papers were returned and 71 were considered appropriate for analysis. Of these 60 papers positively identified their intervention as ‘safe’. These papers were read in full and the number of interventions was recorded along with the rate of complication. 66 data sets were created and the 95% upper confidence interval was calculated for complication rates. Only 16 out of 66 data sets could safely predict a major complication rate of under 5%. Our work would tend to suggest that a failure to apply proper statistical tools is leading to procedures being erroneously classified as safe in the published literature