Advertisement for orthosearch.org.uk
Results 1 - 20 of 190
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 88 - 88
1 Mar 2012
Higgs Z Danks B Sibinski M Rymaszewski L
Full Access

Aim

Over the last 15 years there has been a series of publications reporting the beneficial effects of elbow arthrolysis, with considerable variation in operative technique and post-operative management. Many advocate the use of passive stretching techniques in the early post-operative period if range of motion fails to improve satisfactorily. The purpose of this study was to assess our results of open elbow arthrolysis in patients who did not receive any passive stretching after discharge from hospital.

Methods

Prospectively collected data of 55 patients with a minimum follow-up of 1 year after arthrolysis were analysed. All procedures were performed by the same surgeon (LR), achieving as much improvement in elbow motion as possible at operation. All patients had continuous brachial plexus blocks and continual passive motion for 2-3 days post-operatively but none received any passive stretching after discharge. At review, a senior physiotherapist (BD) formally assessed all the patients.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 89 - 89
23 Feb 2023
Marasco S Gieroba T Di Bella C Babazadeh S Van Bavel D
Full Access

Identifying and restoring alignment is a primary aim of total knee arthroplasty (TKA). In the coronal plane, the pre-pathological hip knee angle can be predicted using an arithmetic method (aHKA) by measuring the medial proximal tibial angle (MPTA) and lateral distal femoral angle (aHKA=MPTA - LDFA). The aHKA is shown to be predictive of coronal alignment prior to the onset of osteoarthritis; a useful guide when considering a non-mechanically aligned TKA. The aim of this study is to investigate the intra- and inter-observer accuracy of aHKA measurements on long leg standing radiographs (LLR) and preoperative Mako CT planning scans (CTs). Sixty-eight patients who underwent TKA from 2020–2021 with pre-operative LLR and CTs were included. Three observers (Surgeon, Fellow, Registrar) measured the LDFA and MPTA on LLR and CT independently on three separate occasions, to determine aHKA. Statistical analysis was undertaken with Bland-Altman test and coefficient of repeatability. An average intra-observer measurement error of 3.5° on LLR and 1.73° on CTs for MPTA was detected. Inter-observer errors were 2.74° on LLR and 1.28° on CTs. For LDFA, average intra-observer measurement error was 2.93° on LLR and 2.3° on CTs, with inter-observer errors of 2.31° on LLR and 1.92° on CTs. Average aHKA intra-observer error was 4.8° on LLR and 2.82° on CTs. Inter-observer error of 3.56° for LLR and 2.0° on CTs was measured. The aHKA is reproducible on both LLR and CT. CT measurements are more reproducible both between and within observers. The difference between measurements using LLR and CT is small and hence these two can be considered interchangeable. CT may obviate the need for LLRs and may overcome difficulties associated with positioning, rotation, body habitus and flexion contractures when assessing coronal alignment


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 57 - 57
1 Nov 2022
Prem R West B Jenner E Bolton L Deshmukh S
Full Access

Abstract. Aim. This study aims to Inter and intra observer reliability compare, use of a standard goniometer (SG) to measure intermetacarpal angle (degrees) vs use of a new technique of using a digital vernier calliper (DVC) (mm) to measure the distance between the first and second metacarpal head. Method. Maximal active abduction and extension of both thumbs was measured in 20 healthy volunteers on two occasions at least one week apart by two assessors. Results. The inter and intra-observer agreement was higher & the variance of the data was lower using the DVC with the new technique than the SG for both thumb abduction and extension. Additionally, the correlation between measurement of extension and abduction was higher using the DVC than the SG. Conclusion. Whilst both tools provide acceptable intra and inter-observer agreement, the new technique using a DVC is consistently better and more reliable than a SG in measuring thumb abduction and extension. The study also supports our hypothesis that the thumb rotates around the second metacarpal head with a consistent radius


The purpose of this study was to investigate the effectiveness of casting in achieving acceptable radiological parameters for unstable ankle injuries. This retrospective observational cohort study was conducted involving the retrieval of X-rays of all ankles taken over a 2 year period in an urban setting to investigate the radiological outcomes of cast management for unstable ankle fractures using four acceptable parameters measured on a single X- ray at union. The Picture Archiving and Communication System (PACS) was used, the X-rays were measured by a single observer. From the 1st of January 2020 to the 31st of December 2021, a total of 1043 ankle fractures were treated at the three hospitals with a male to female ratio of 1:1.7. Of the 628 unstable ankle injuries, 19% of patients were lost to follow up. 190 were managed conservatively with casts, requiring an average of 4 manipulations, with a malunion rate of 23.2%. Unstable ankle injuries that were treated surgically from the outset and those who failed conservative management and subsequently converted to surgery had a malunion rate of 8.1% and 11.0% respectively. Unstable ankle fractures pose a challenge with a high rate of radiological malunion, regardless of the treatment Casting surgery from the outset or converted to surgery, with rates of 23% and 8% and 11% respectively. In this multivariate analysis we found that conservative management was the only factor influencing the incidence of malunion, age, sex and type of fracture did not have a scientific significant influence


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 23 - 23
10 May 2024
Leary J Lynskey T Muller A
Full Access

Objective. Carpal tunnel release surgery is a commonly performed procedure for alleviating symptoms of median nerve compression and restoring hand function. With pressure on theatre time these procedures are now commonly performed in a step-down out-patient facility under local anaesthetic. The choice of suture for skin closure in this procedure can impact the quality of wound healing, patient outcomes and the follow-up required however the question of the best type of suture remains unanswered. The purpose of this study was to compare the outcomes of absorbable and non-absorbable sutures using a randomised control trial design. Methods. Eighty patients diagnosed with bilateral carpal tunnel syndrome were enrolled and underwent outpatient carpal tunnel release surgery under local anaesthetic in a staged fashion. Random number generation was used to assign each hand to receive interrupted nylon or Vicryl Rapide sutures. Pre-operative data collection included patient demographics, ASA, inflammatory conditions, smoking status as well as a Boston Carpal Tunnel Questionnaire (BCTQ) for each hand. Patients were followed up at 2 and 6 weeks after each operation and the BCTQ was repeated along with the Patient and Observer Scar Assessment Scale and the VAS score for wound discomfort. This study has approval from the DHB ethics committee, Local Iwi, HDC and ANZ Clinical Trials:ACTRN12623000100695. Results. Statistical analysis assessed patient preference and the scores between the groups. Multi-variate analysis was performed to assess the factors that may be contributing to patient choice. Conclusion. Insights into patient preference and clinical outcomes associated with absorbable sutures and non-absorbable sutures in the setting of out-patient surgery are discussed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 41 - 41
23 Feb 2023
Bekhit P Saffi M Hong N Hong T
Full Access

Acromial morphology has been implicated as a risk factor for unidirectional posterior shoulder instability. Studies utilising plain film radiographic landmarks have identified an increased risk of posterior shoulder dislocation in patients with higher acromion positioning. The aims of this study were to develop a reproducible method of measuring this relationship on cross sectional imaging and to evaluate acromial morphology in patients with and without unidirectional posterior shoulder instability. We analysed 24 patients with unidirectional posterior instability. These were sex and age matched with 61 patients with unidirectional anterior instability, as well as a control group of 76 patients with no instability. Sagittal T1 weighted MRI sequences were used to measure posterior acromial height relative to the scapular body axis (SBA) and long head of triceps insertion axis (LTI). Two observers measured each method for inter-observer reliability, and the intraclass correlation coefficient (ICC) calculated. LTI method showed good inter-observer reliability with an ICC of 0.79. The SBA method was not reproducible due suboptimal MRI sequences. Mean posterior acromial height was significantly greater in the posterior instability group (14.2mm) compared to the anterior instability group (7.7mm, p=0.0002) as well when compared with the control group (7.0mm, p<0.0001). A threshold of 7.5mm demonstrated a significant increase in the incidence of posterior shoulder instability (RR = 9.4). We conclude that increased posterior acromial height is significantly associated with posterior shoulder instability. This suggests that the acromion has a role as an osseous restraint to posterior shoulder instability


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 30 - 30
1 Dec 2022
Lohre R Lobo A Bois A Pollock J Lapner P Athwal G Goel D
Full Access

Glenoid baseplate orientation in reverse shoulder arthroplasty (RSA) influences clinical outcomes, complications, and failure rates. Novel technologies have been produced to decrease performance heterogeneity of low and high-volume surgeons. This study aimed to determine novice and experienced shoulder surgeon's ability to accurately characterise glenoid component orientation in an intra-operative scenario. Glenoid baseplates were implanted in eight fresh frozen cadavers by novice surgical trainees. Glenoid baseplate version, inclination, augment rotation, and superior-inferior centre of rotation (COR) offset were then measured using in-person visual assessments by novice and experienced shoulder surgeons immediately after implantation. Glenoid orientation parameters were then measured using 3D CT scans with digitally reconstructed radiographs (DRRs) by two independent observers. Bland-Altman plots were produced to determine the accuracy of glenoid orientation using standard intraoperative assessment compared to postoperative 3D CT scan results. Visual assessment of glenoid baseplate orientation showed “poor” to “fair” correlation to 3D CT DRR measurements for both novice and experienced surgeon groups for all measured parameters. There was a clinically relevant, large discrepancy between intra-operative visual assessments and 3D CT DRR measurements for all parameters. Errors in visual assessment of up to 19.2 degrees of inclination and 8mm supero-inferior COR offset occurred. Experienced surgeons had greater measurement error than novices for all measured parameters. Intra-operative measurement errors in glenoid placement may reach unacceptable clinical limits. Kinesthetic input during implantation likely improves orientation understanding and has implications for hands-on learning


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 25 - 25
7 Nov 2023
du Plessis R Roche S du Plessis J Dey R de Kock W de Wet J
Full Access

The Latarjet procedure is a well described method to stabilize anterior shoulder instability. There are concerns of high complication rates, one of these being a painful shoulder without instability due to screw irritation. The arthroscopic changes in the shoulder at time of screw removal compared to those pre-Latarjet have not been described in the literature. We conducted a retrospective review of arthroscopic videos between 2015 and 2022 of 17 patients at the time of their Latarjet screw removal and where available (n=13) compared them to arthroscopic findings at time of index Latarjet. Instability was an exclusion criterion. X-rays prior to screw removal were assessed independently by two observers blinded to patient details for lysis of the graft. Arthroscopic assessment of the anatomy and pathological changes were made by two shoulder surgeons via mutual consensus. An intraclass correlation coefficient (ICC) was analyzed as a measure for the inter-observer reliability for the radiographs. Our cohort had an average age of 21.5±7.7 years and an average period of 16.2±13.1 months between pre- and post-arthroscopy. At screw removal all patients had an inflamed subscapularis muscle with 88% associated musculotendinous tears and 59% had a pathological posterior labrum. Worsening in the condition of subscapularis muscle (93%), humeral (31%) and glenoid (31%) cartilage was found when compared to pre-Latarjet arthroscopes. Three failures of capsular repair were seen, two of these when only one anchor was used. X-ray review demonstrated 79% of patients had graft lysis. Excellent inter-rater reliability was observed with an ICC value of 0.82. Our results show a high rate of pathological change in the subscapularis muscle, glenoid labrum and articular cartilage in the stable but painful Latarjet. 79% of patients had graft lysis with prominent screws on X-ray


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 13 - 13
3 Mar 2023
Rohra S Sinha A Kemp M Rethnam U
Full Access

Background. Dynamic Hip Screw (DHS) is the most frequently used implant in management of intertrochanteric femoral fractures. There is a known statistical relationship between a tip-apex distance (TAD) >25mm and higher rate of implant failure. Our aim was to analyse all DHS procedures performed in our trust from seventeen months and compare their TAD values to the acceptable standard of ≤25mm. Methods. All patients undergoing DHS between April 2020-August 2021 were identified from our theatre system. Additionally, those presenting to hospital with implant failures were included. Patient demographics, date of surgery, fracture classification (AO) and date/mode of failure were recorded. Intraoperative fluoroscopy images were reviewed to calculate TAD, screw location and neck shaft angles by two independent observers. Results. 215 patients were identified, five of which were excluded due to inadequate fluoroscopy. Failure was seen in 3.3% of the cohort (n=7), of which 71.4% had an unacceptable TAD. In total, 21 patients (10%) had TAD >25mm, of whom 12 had superiorly and 15 had posteriorly placed screws. There were no failures in patients with a TAD of <20mm whereas a TAD >30mm had 50% failure rate. Conclusion. This audit reinforces the importance of aiming for a low TAD (preferably <20mm) intraoperatively. It is also desirable to avoid superiorly and significantly posteriorly placed screws. Implications. Complex hip revision surgery in the elderly bears substantial financial implications to the NHS and, more importantly, causes prolonged morbidity to the patient. Adhering to established standards will ensure reduced implant failure and best patient care


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 114 - 114
23 Feb 2023
Chai Y Boudali A Farey J Walter W
Full Access

Human error is usually evaluated using statistical descriptions during radiographic annotation. The technological advances popularized the “non-human” landmarking techniques, such as deep learning, in which the error is presented in a confidence format that is not comparable to that of the human method. The region-based landmark definition makes an arbitrary “ground truth” point impossible. The differences in patients’ anatomies, radiograph qualities, and scales make the horizontal comparison difficult. There is a demand to quantify the manual landmarking error in a probability format. Taking the measurement of pelvic tilt (PT) as an example, this study recruited 115 sagittal pelvic radiographs for the measurement of two PTs. We proposed a method to unify the scale of images that allows horizontal comparisons of landmarks and calculated the maximum possible error using a density vector. Traditional descriptive statistics were also applied. All measurements showed excellent reliabilities (intraclass correlation coefficients > 0.9). Eighty-four measurements (6.09%) were qualified as wrong landmarks that failed to label the correct locations. Directional bias (systematic error) was identified due to cognitive differences between observers. By removing wrong labels and rotated pelves, the analysis quantified the error density as a “good doctor” performance and found 6.77°-11.76° maximum PT disagreement with 95% data points. The landmarks with excellent reliability still have a chance (at least 6.09% in our case) of making wrong landmark decisions. Identifying skeletal contours is at least 24.64% more accurate than estimating landmark locations. The landmark at a clear skeletal contour is more likely to generate systematic errors. Due to landmark ambiguity, a very careful surgeon measuring PT could make a maximum 11.76° random difference in 95% of cases, serving as a “good doctor benchmark” to qualify good landmarking techniques


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 23 - 23
1 Jul 2020
St George S Veljkovic A Hamedany HS Wing K Penner M Salat P Younger ASE
Full Access

Classification systems for the reporting of surgical complications have been developed and adapted for many surgical subspecialties. The purpose of this systematic review was to examine the variability and frequency of reporting terms used to describe complications in ankle fracture fixation. We hypothesized that the terminology used would be highly variable and inconsistent, corroborating previous results that have suggested a need for standardized reporting terminology in orthopaedics. Ankle fracture outcome studies meeting predetermined inclusion and exclusion criteria were selected for analysis by two independent observers. Terms used to define adverse events were identified and recorded. If a difference occurred between the two observers, a third observer was enlisted. Results of both observers were compared. All terms were then compiled and assessed for variability and frequency of use throughout the studies involved. Reporting terminology was subsequently grouped into 10 categories. In the 48 studies analyzed, 301 unique terms were utilized to describe adverse events. Of these terms, 74.4% (224/301) were found in a single study each. Only one term, “infection”, was present in 50% of studies, and only 19 of 301 terms (6.3%) were used in at least 10% of papers. The category that was most frequently reported was infection, with 89.6% of studies reporting on this type of adverse event using 25 distinct terms. Other categories were “wound healing complications” (72.9% of papers, 38 terms), “bone/joint complications” (66.7% of papers, 35 terms), “hardware/implant complications” (56.3% of papers, 47 terms), “revision” (56.3% of papers, 35 terms), “cartilage/soft tissue injuries” (45.8% of papers, 31 terms), “reduction/alignment issues” (45.8% of papers, 29 terms),“medical complications” (43.8% of papers, 32 terms), “pain” (29.2% of papers, 16 terms) and “other complications” (20.8% of papers, 13 terms). There was a 78.6% interobserver agreement in the identification of adverse terms across the 48 studies included. The reporting terminology utilized to describe adverse events in ankle fracture fixation was found to be highly variable and inconsistent. This variability prevents accurate reporting of adverse events and makes the analysis of potential outcomes difficult. The development of standardized reporting terminology in orthopaedics would be instrumental in addressing these challenges and allow for more accurate and consistent outcomes reporting


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 100 - 100
23 Feb 2023
Tran T Driessen B Yap V Ng D Khorshid O Wall S Yates P Prosser G Wilkinson M Hazratwala K
Full Access

Clinical success of prostheses in joint arthroplasty is ultimately determined by survivorship and patient satisfaction. The purpose of this study was to compare (non-inferiority) a new morphometric designed stem for total hip arthroplasty (THA) against an established comparator. A prospective randomised multi-centre study of 144 primary cementless THA performed by nine experienced orthopaedic surgeons was completed (70 received a fully coated collarless tapered stem and 74 received a morphometric designed proximally coated tapered stem). PROMs and blood serum markers were assessed preoperatively and at intervals up to 2-years postoperatively. In addition, measures of femoral stem fit, fill and subsidence at 2-years post-operatively were measured from radiographs by three observers, with an intra-class correlation coefficient of 0.918. A mixed effects model was employed to compare the two prosthesis over the study period. A p-value <0.05 was considered statistically significant. Demographics, Dorr types and blood serum markers were similar between groups. Both stems demonstrated a significant improvement in PROMs between the pre- and post-operative measurements, with no difference at any timepoint (p > 0.05). The fully coated tapered collarless femoral stem had a non-significantly higher intra-operative femoral fracture rate (5.8% vs 1.4%, p = 0.24), with all patients treated with cable fixation and partial weight bearing. The mean subsidence at 2-years was 2.5mm +/- 2.3mm for the morphometric stem and 2.4mm +/- 1.8mm for the fully coated tapered collarless femoral stem (p = 0.879). There was one outlier in each group with increased subsidence (fully coated tapered collarless femoral stem 6.9mm, morphometric wedge stem 7.4mm), with both patients reporting thigh pain at 2 years. When compared with an established stem, the newer designed morphometric wedge stem performed well with comparable radiological and PROM outcomes at 2 year follow up. Continued follow-up is required for long term benchmarking


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 115 - 115
23 Feb 2023
Chai Y Boudali A Farey J Walter W
Full Access

Pelvic tilt (PT) is always described as the pelvic orientation along the transverse axis, yet four PT definitions were established based on different radiographic landmarks: anterior pelvic plane (PT. a. ), the centres of femoral heads and sacral plate (PT. m. ), pelvic outlet (PT. h. ), and sacral slope (SS). These landmarks quantify a similar concept, yet understanding of their relationships is lacking. Some studies referred to the words “pelvic tilt” for horizontal comparisons, but their PT definitions might differ. There is a demand for understanding their correlations and differences for education and research purposes. This study recruited 105 sagittal pelvic radiographs (68 males and 37 females) from a single clinic awaiting their hip surgeries. Hip hardware and spine pathologies were examined for sub-group analysis. Two observers annotated four PTs in a gender-dependent manner and repeated it after six months. The linear regression model and intraclass correlation coefficient (ICC) were applied with a 95% significance interval. The SS showed significant gender differences and the lowest correlations to the other parameters in the male group (-0.3< r <0.2). The correlations of SS in scoliosis (n = 7) and hip implant (female, n = 18) groups were statistically different, yet the sample sizes were too small. PT. m. demonstrated very strong correlation to PT. h. (r > 0.9) under the linear model PT. m. = 0.951 × PT. h. - 68.284. The PT. m. and PT. h. are interchangeable under a simple linear regression model, which enables study comparisons between them. In the male group, SS is more of a personalised spinal landmark independent of the pelvic anatomy. Female patients with hip implant may have more static spinopelvic relationships following a certain pattern, yet a deeper study using a larger dataset is required. The understanding of different PTs improves anatomical education


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 36 - 36
10 Feb 2023
Driessen B Yap V Ng D Korshid O Wall S Yates P Prosser G Wilkinson M Hazratwala K Tran. T
Full Access

Clinical success of prostheses in joint arthroplasty is ultimately determined by survivorship and patient satisfaction. The purpose of this study was to compare (non-inferiority) a new morphometric designed stem for total hip arthroplasty (THA) against an established comparator. A prospective randomised multi-centre study of 144 primary cementless THA performed by nine experienced orthopaedic surgeons was completed (70 received a fully coated collarless tapered stem and 70 received a morphometric designed proximally coated tapered stem). PROMs and blood serum markers were assessed preoperatively and at intervals up to 2-years postoperatively. In addition, measures of femoral stem fit, fill and subsidence at 2-years post-operatively were measured from radiographs by three observers, with an intra-class correlation coefficient of 0.918. A mixed effects model was employed to compare the two prostheses over the study period. A p-value <0.05 was considered statistically significant. Demographics and Dorr types were similar between groups. Both stems demonstrated a significant improvement in PROMs between the pre- and post-operative measurements, with no difference at any timepoint (p > 0.05). The fully coated tapered collarless femoral stem had a non-significantly higher intra-operative femoral fracture rate (5.8% vs 1.4%, p = 0.24), with all patients treated with cable fixation and partial weight bearing. The mean subsidence at 2-years was 2.5mm +/- 2.3mm for the morphometric stem and 2.4mm +/- 1.8mm for the fully coated tapered collarless femoral stem (p = 0.879). There was one outlier in each group with increased subsidence (fully coated tapered collarless femoral stem 6.9mm, morphometric wedge stem 7.4mm), with both patients reporting thigh pain at 2 years. When compared with an established stem, the newer designed morphometric wedge stem performed well with comparable radiological and PROM outcomes at 2 year follow up. Continued follow-up is required for long term benchmarking


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 11 - 11
10 Feb 2023
Boyle A George C MacLean S
Full Access

A larger radial tuberosity, and therefore a smaller radioulnar space, may cause mechanical impingement of the DBT predisposing to tear. We sought to investigate anatomic factors associated with partial DBT tears by retrospectively reviewing 3-T MRI scans of elbows with partial DBT tears and a normal elbow comparison group. 3-T MRI scans of elbows with partial DBT tears and elbows with no known pathology were reviewed retrospectively by two independent observers. Basic demographic data were collected and measurements of radial tuberosity length, radial tuberosity thickness, radio-ulnar space, and radial tuberosity-ulnar space were made using simultaneous tracker lines and a standardised technique. The presence or absence of enthesophytes and the presence of a single or double DBT were noted. 26 3-T MRI scans of 26 elbows with partial DBT tears and 30 3-T MRI scans of 30 elbows without pathology were included. Basic demographic data was comparable between the two groups. The tear group showed statistically significant larger mean measurements for radial tuberosity length (24.3mm vs 21.3mm, p=0.002), and radial tuberosity thickness (5.5mm vs 3.7mm, p=<0.0001. The tear group also showed statistically significant smaller measurements for radio-ulnar space (8.2mm vs 10.0mm, p=0.010), and radial tuberosity-ulnar space (7.2mm vs 9.1mm, p=0.013). There was a statistically significant positive correlation between partial DBT tears and presence of enthesophytes (p=0.007) as well as between partial DBT tears and having two discrete DBTs rather than a single or interdigitating tendon (p=<0.0001). Larger radial tuberosities, and smaller radio-ulnar and radial tuberosity-ulnar spaces are associated with partial DBT tears. This may be due to chronic impingement, tendon delamination and consequent weakness which ultimately leads to tears. Enthesophytes may be associated with tears for the same reason. Having two discrete DBTs that do not interdigitate prior to insertion is also associated with partial tears


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 20 - 20
23 Apr 2024
Guichet J
Full Access

Introduction. Frame HI is the #Days for device removal/cm. IM Nail HI is less relevant (31–45 D/cm). Albizzia HI was 33 D/cm (1991–2003). Patients felt fine approximately 1M after end of lengthening (EoL), resuming normal life and sports. This sometimes resulted in implants fractures (e.g. skying before bone fusion). Ideally, the full fusion should occur at the EoL. We decided to shorten the HI to reach this target, optimising all parameters. Materials & Methods. The evolution of care has been monitored over a 32-year clinical experience with a fully weight-bearing nails (Albizzia then G-nail). Monitoring was with X-rays, DEXA, blood bone activity, and in London with special 5G CBCT Scans. We implemented several changes in the Care of patients and measured them according to the ‘Five Principles’ (stability, function, ‘Roads-vascular supply’, ‘Materials-calories’ and ‘Workers-BFC’, with actions on food intake, activity levels and on muscle and bone vascular growths. Results. Preop: training (vascularity, muscle force). Op & Postop: spine morphine, IM sawing preserving BFC, controlled hypo-pressure, low hydration, 50 cm leg elevation, walking, resistance bike, full motion (drainage, muscle reactivation), discharge 3–4h postop (including bilateral). Postop daily intense gym training. POD07-21: Distraction increased to fight non-linear hyper-ossification (44–50 mm gain at POD30) +/- aided by NSAIDs. HI decreased to 12–20D/cm, sometimes 8D/cm with some ‘soft fusion’ during lengthening, hardening within 1W after EoL. Conclusions. The surgeon is not a passive X-rays observer, but has an active role in changing the healing speed and decreasing HI for patient safety. Electro/Magnetic nails (torque 1 Nm) may be clocked by bone fusion, which does not occur with the G-Nail (19 Nm). An holistic vision for patients and treatments at several levels is essential to accelerate bone healing, and to return fast to full normal life, after a short ‘lengthening parenthesis’


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 45 - 45
1 Jul 2020
Mahmood F Burt J Bailey O Clarke J Baines J
Full Access

In the vast majority of patients, the anatomical and mechanical axes of the tibia in the coronal plane are widely accepted to be equivalent. This philosophy guides the design and placement of orthopaedic implants within the tibia and in both the knee and ankle joints. However, the presence of coronal tibial bowing may result in a difference between these two axes and hence cause suboptimal placement of implanted prostheses. Although the prevalence of tibial bowing in adults has been reported in Asian populations, to date no exploration of this phenomenon in a Western population has been conducted. The aim of this study was to quantify the prevalence of coronal tibial bowing in a Western population. This was an observational retrospective cohort study using anteroposterior long leg radiographs collected prior to total knee arthroplasty in our high volume arthroplasty unit. Radiographs were reviewed using a Picture Archiving and Communication System. Using a technique previously described in the literature for assessment of tibial bowing, two lines were drawn, each one third of the length of the tibia. The first line was drawn between the tibial spines and the centre of the proximal third of the tibial medullary canal. The second was drawn from the midpoint of the talar dome to the centre of the distal third of the tibial medullary canal. The angle subtended by these two lines was used to determine the presence of bowing. Bowing was deemed significant if more than two degrees. The position of the apex of the bow determined whether it was medial or lateral. Measurements were conducted by a single observer and 10% of measurements were repeated by the same observer and also by two separate observers to allow calculation of intraclass correlation coefficients (ICCs). A total of 975 radiographs consecutively performed in the calendar years 2015–16 were reviewed, 485 of the left leg and 490 of the right. In total 399 (40.9%) tibiae were deemed to have bowing more than two degrees. 232 (23.8%) tibiae were bowed medially and 167 (17.1%) were bowed laterally. The mean bowing angle was 3.51° (s.d. 1.24°) medially and 3.52° (s.d. 1.33°) laterally. Twenty-three patients in each group (9.9% medial/13.7% lateral) were bowed more than five degrees. The distribution of bowing angles followed a normal distribution, with the maximal angle observed 10.45° medially and 9.74° laterally. An intraobserver ICC of 0.97 and a mean interobserver ICC of 0.77 were calculated, indicating excellent reliability. This is the first study reporting the prevalence of tibial bowing in a Western population. In a significant proportion of our sample, there was divergence between the anatomical and mechanical axes of the tibia. This finding has implications for both the design and implantation of orthopaedic prostheses, particularly in total knee arthroplasty. Further research is necessary to investigate whether prosthetic implantation based on the mechanical axis in bowed tibias results in suboptimal implant placement and adverse clinical outcomes


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 42 - 42
1 Jul 2020
Rollick N Helfet D Bear J Diamond O Wellman D
Full Access

Malreduction of the syndesmosis is a poor prognosticator following ankle fracture and has been documented in as many as 52% of patients following fracture fixation. The current standard for assessment of reduction of the syndesmosis is bilateral computed tomography (CT) scan of the ankle. Multiple radiographic parameters are utilized to define malreduction, however, there has been limited investigation into the accuracy of these measurements to differentiate malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Bilateral lower extremity CT scans including ankles were screened. Studies were excluded if the patient was skeletally immature, had pathology below the knee or if they had congenital neuromuscular syndromes. The resulting cohort consisted of 207 patients. The indication for bilateral CT scan was femoral acetabular impingement in 110 patients (53%), rotation assessment following arthroplasty in 32 patients (15%), rotation assessment following femoral fracture in 30 patients (14%), rotational assessment for patellar instability in 30 patients (14%) and five miscellaneous indications (2%). Fifty patients were reviewed by three observers independently and to determine inter-observer reliability. A single observer repeated the measurements within the same cohort four weeks later to evaluate intra-observer reliability. Three observers then measured the anterior syndesmotic distance, posterior syndesmotic distance, central syndesmotic distance, fibular rotation and sagittal fibular translation at 1cm from the distal tibial articular surface. Overall side to side variability between the left and right ankle were assessed. Previously studied malreduction standards were evaluated. These included: anterior to posterior syndesmotic distance > 2mm, central syndesmotic difference > 1.5mm, average syndesmotic distance > 2mm, fibular rotational difference > 10o and sagittal translational difference > 2mm. The inter- and intra-observer reliability was good to excellent for anterior, posterior and central syndesmotic distance, and fibular rotation measurements. Sagittal fibular translation had an ICC of 0.583, and thus was only of fair reliability. Side to side comparison revealed statistically significant difference in only anterior syndesmotic difference (p=0.038). A difference of anterior to posterior syndesmotic distance of greater than 2mm was observed in 43 patients (20.2%). Thirty eight patients (17.8%) had a central syndesmotic difference of greater than 1.5mm. A fibular rotational difference of greater than 10o was observed in 49 patients (23%). The average difference between the anterior and posterior syndesmosis was greater than 2mm in 17 patients (8.2%). Nine patients (4.2%) had sagittal translation of greater than 2mm. Eighty one patients (39%) demonstrated at least one parameter beyond previously set standards for malreduction. Only one parameters was anomalous in 54 patients (26%), 18 patients (8%) had two positive parameters, while eight patients (4%) had three. One patient was asymmetrical in all measured parameters. In this study there was no statistically significant asymmetry between ankles. However, 39% of native syndesmoses would be classified as malreduced on CT scan using previously studied malreduction limits. Current radiographic parameters are not sufficient to differentiate mild inherent anatomical asymmetry from malreduction of the syndesmosis


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 31 - 31
1 Dec 2016
Younger A Penner M Glazebrook M Goplen G Daniels T Veljkovic A Lalonde K Wing K Dryden P Wong H
Full Access

Reoperations may be a better way of tracking adverse outcomes than complications. Repeat surgery causes cost to the system, and often indicate failure of the primary procedure resulting in the patient not achieving the expected improvement in pain and function. Understanding the cause of repeat surgery at the primary site may result in design improvements to implants or improvements to fusion techniques resulting in better outcomes in the future. The COFAS group have designed a reoperation classification system. The purpose of this study was to outline the inter and intra observer reliability of this classification scheme. To verify the inter- and intra-observer reliability of this new coding system, six fellow ship trained practicing foot and ankle Orthopaedic surgeons were asked to classify 62 repeat surgeries from a single surgeons practice. The six surgeons read the operation reports in random order, and reread the reports 2 weeks later in a different order. Reliability was determined using intraclass correlation coefficients (ICC) and proportions of agreement. The agreement between pairs of readings (915 for inter observer for the first and second read – 61 readings with 15 comparisons, observer 1 with observer 2, observer 1 with observer 3, etc) was determined by seeing how often each observer agreed. This was repeated for the 366 ratings for intra observer readings (61 times 6). The inter-observer reliability on the first read had a mean intra-class correlation coefficient (ICC) of 0.89. The range for the 15 comparisons was 0.81 to 1.0. Amongst all 1830 paired codings between two observers, 1605 (88%) were in agreement. Across the 61 cases, 45 (74%) were given the same code by all six observers. However, the difference when present was larger with more observers not agreeing. The inter-observer reliability test on the second read had a mean ICC of 0.94, with a range of 0.90. There were 43 (72%) observations that were the same across all six observers. Of all pairs (915 in total) there was agreement in 804 pairs for the first reading (88%) and disagreement in 111 (12%). For the second reading there was agreement in 801 pairs (86%) and disagreement in 114 (14%). The intra-observer reliability averaged an ICC value of 0.92, with a range of 0.86 to 0.98. The observers agreed with their own previous observations 324 times out of 366 paired readings (89% agreement of pairs). The COFAS classification of reoperations for end stage ankle arthritis was reliable. This scheme potentially could be applied to other areas of Orthopaedic surgery and should replace the Claiden Dindo modifications that do not accurately reflect Orthopaedic outcomes. As complications are hard to define and lack consistent terminology reoperations and resource utilisation (extra clinic visits, extra days in hospital and extra hours of surgery) may be more reliable measures of the negative effects of surgery


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 30 - 30
1 Dec 2016
Gosselin-Papadopoulas N Laflamme Y Menard J Rouleau D Leduc S Davies J Nault M
Full Access

Reoperations may be a better way of tracking adverse outcomes than complications. Repeat surgery causes cost to the system, and often indicate failure of the primary procedure resulting in the patient not achieving the expected improvement in pain and function. Understanding the cause of repeat surgery at the primary site may result in design improvements to implants or improvements to fusion techniques resulting in better outcomes in the future. The COFAS group have designed a reoperation classification system. The purpose of this study was to outline the inter and intra observer reliability of this classification scheme. To verify the inter- and intra-observer reliability of this new coding system, six fellow ship trained practicing foot and ankle Orthopaedic surgeons were asked to classify 62 repeat surgeries from a single surgeons practice. The six surgeons read the operation reports in random order, and reread the reports 2 weeks later in a different order. Reliability was determined using intraclass correlation coefficients (ICC) and proportions of agreement. The agreement between pairs of readings (915 for inter observer for the first and second read – 61 readings with 15 comparisons, observer 1 with observer 2, observer 1 with observer 3, etc) was determined by seeing how often each observer agreed. This was repeated for the 366 ratings for intra observer readings (61 times 6). The inter-observer reliability on the first read had a mean intra-class correlation coefficient (ICC) of 0.89. The range for the 15 comparisons was 0.81 to 1.0. Amongst all 1830 paired codings between two observers, 1605 (88%) were in agreement. Across the 61 cases, 45 (74%) were given the same code by all six observers. However, the difference when present was larger with more observers not agreeing. The inter-observer reliability test on the second read had a mean ICC of 0.94, with a range of 0.90. There were 43 (72%) observations that were the same across all six observers. Of all pairs (915 in total) there was agreement in 804 pairs for the first reading (88%) and disagreement in 111 (12%). For the second reading there was agreement in 801 pairs (86%) and disagreement in 114 (14%). The intra-observer reliability averaged an ICC value of 0.92, with a range of 0.86 to 0.98. The observers agreed with their own previous observations 324 times out of 366 paired readings (89% agreement of pairs). The COFAS classification of reoperations for end stage ankle arthritis was reliable. This scheme potentially could be applied to other areas of Orthopaedic surgery and should replace the Claiden Dindo modifications that do not accurately reflect Orthopaedic outcomes. As complications are hard to define and lack consistent terminology reoperations and resource utilisation (extra clinic visits, extra days in hospital and extra hours of surgery) may be more reliable measures of the negative effects of surgery