Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 48 - 48
1 Dec 2022
Yee N Iorio C Shkumat N Rocos B Ertl-Wagner B Green A Lebel D Camp M
Full Access

Neuromuscular scoliosis patients face rates of major complications of up to 49%. Along with pre-operative risk reduction strategies (including nutritional and bone health optimization), intra-operative strategies to decrease blood loss and decrease surgical time may help mitigate these risks. A major contributor to blood loss and surgical time is the insertion of instrumentation which is challenging in neuromuscular patient given their abnormal vertebral and pelvic anatomy. Standard pre-operative radiographs provide minimal information regarding pedicle diameter, length, blocks to pedicle entry (e.g. iliac crest overhang), or iliac crest orientation. To minimize blood loss and surgical time, we developed an “ultra-low dose” CT protocol without sedation for neuromuscular patients. Our prospective quality improvement study aimed to determine: if ultra-low dose CT without sedation was feasible given the movement disorders in this population; what the radiation exposure was compared to standard pre-operative imaging; whether the images allowed accurate assessment of the anatomy and intra-operative navigation given the ultra-low dose and potential movement during the scan. Fifteen non-ambulatory surgical patients with neuromuscular scoliosis received the standard spine XR and an ultra-low dose CT scan. Charts were reviewed for etiology of neuromuscular scoliosis and medical co-morbidities. The CT protocol was a high-speed, high-pitch, tube-current modulated acquisition at a fixed tube voltage. Adaptive statistical iterative reconstruction was applied to soft-tissue and bone kernels to mitigate noise. Radiation dose was quantified using reported dose indices (computed tomography dose index (CTDIvol) and dose-length product (DLP)) and effective dose (E), calculated through Monte-Carlo simulation. Statistical analysis was completed using a paired student's T-test (α = 0.05). CT image quality was assessed for its use in preoperative planning and intraoperative navigation using 7D Surgical System Spine Module (7D Surgical, Toronto, Canada). Eight males and seven females were included in the study. Their average age (14±2 years old), preoperative Cobb angle (95±21 degrees), and kyphosis (60±18 degrees) were recorded. One patient was unable to undergo the ultra-low dose CT protocol without sedation due to a co-diagnosis of severe autism. The average XR radiation dose was 0.5±0.3 mSv. Variability in radiographic dose was due to a wide range in patient size, positioning (supine, sitting), number of views, imaging technique and body habitus. Associated CT radiation metrics were CTDIvol = 0.46±0.14 mGy, DLP = 26.2±8.1 mGy.cm and E = 0.6±0.2 mSv. CT radiation variability was due to body habitus and arm orientation. The radiation dose differences between radiographic and CT imaging were not statistically significant. All CT scans had adequate quality for preoperative assessment of pedicle diameter and orientation, obstacles impeding pedicle entry, S2-Alar screw orientation, and intra-operative navigation. “Ultra-low dose” CT scans without sedation were feasible in paediatric patients with neuromuscular scoliosis. The effective dose was similar between the standard preoperative spinal XR and “ultra-low dose” CT scans. The “ultra-low dose” CT scan allowed accurate assessment of the anatomy, aided in pre-operative planning, and allowed intra-operative navigation despite the movement disorders in this patient population


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 68 - 68
1 Dec 2022
Yee N Lorio C Shkumat N Rocos B Ertl-Wagner B Green A Lebel D Camp M
Full Access

Neuromuscular scoliosis patients face rates of major complications of up to 49%. Along with pre-operative risk reduction strategies (including nutritional and bone health optimization), intra-operative strategies to decrease blood loss and decrease surgical time may help mitigate these risks. A major contributor to blood loss and surgical time is the insertion of instrumentation which is challenging in neuromuscular patient given their abnormal vertebral and pelvic anatomy. Standard pre-operative radiographs provide minimal information regarding pedicle diameter, length, blocks to pedicle entry (e.g. iliac crest overhang), or iliac crest orientation. To minimize blood loss and surgical time, we developed an “ultra-low dose” CT protocol without sedation for neuromuscular patients. Our prospective quality improvement study aimed to determine:. if ultra-low dose CT without sedation was feasible given the movement disorders in this population;. what the radiation exposure was compared to standard pre-operative imaging;. whether the images allowed accurate assessment of the anatomy and intra-operative navigation given the ultra-low dose and potential movement during the scan. Fifteen non-ambulatory surgical patients with neuromuscular scoliosis received the standard spine XR and an ultra-low dose CT scan. Charts were reviewed for etiology of neuromuscular scoliosis and medical co-morbidities. The CT protocol was a high-speed, high-pitch, tube-current modulated acquisition at a fixed tube voltage. Adaptive statistical iterative reconstruction was applied to soft-tissue and bone kernels to mitigate noise. Radiation dose was quantified using reported dose indices (computed tomography dose index (CTDIvol) and dose-length product (DLP)) and effective dose (E), calculated through Monte-Carlo simulation. Statistical analysis was completed using a paired student's T-test (α= 0.05). CT image quality was assessed for its use in preoperative planning and intraoperative navigation using 7D Surgical System Spine Module (7D Surgical, Toronto, Canada). Eight males and seven females were included in the study. Their average age (14±2 years old), preoperative Cobb angle (95±21 degrees), and kyphosis (60±18 degrees) were recorded. One patient was unable to undergo the ultra-low dose CT protocol without sedation due to a co-diagnosis of severe autism. The average XR radiation dose was 0.5±0.3 mSv. Variability in radiographic dose was due to a wide range in patient size, positioning (supine, sitting), number of views, imaging technique and body habitus. Associated CT radiation metrics were CTDIvol = 0.46±0.14 mGy, DLP = 26.2±8.1 mGy.cm and E = 0.6±0.2 mSv. CT radiation variability was due to body habitus and arm orientation. The radiation dose differences between radiographic and CT imaging were not statistically significant. All CT scans had adequate quality for preoperative assessment of pedicle diameter and orientation, obstacles impeding pedicle entry, S2-Alar screw orientation, and intra-operative navigation. “Ultra-low dose” CT scans without sedation were feasible in paediatric patients with neuromuscular scoliosis. The effective dose was similar between the standard preoperative spinal XR and “ultra-low dose” CT scans. The “ultra-low dose” CT scan allowed accurate assessment of the anatomy, aided in pre-operative planning, and allowed intra-operative navigation despite the movement disorders in this patient population


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 2 - 2
1 Dec 2014
Dunn R Mjoli N
Full Access

Background:. Spinal deformity surgery carries the risk of loss of neurological function which may be permanent. Although the overall the incidence is low it is much higher in complex congenital deformities or those with pre-existing myelopathy. Intra-operative spinal cord monitoring allows this risk to be reduced by providing feedback to the surgeon while the corrective manoeuvres are performed. Although ideally a trained technician with multimodal monitoring is recommended, it is often not an option in a resource limited environment and surgeon operated technology is used. Aim:. to evaluate the use of surgeon operated trans-cranial motor evoked potentials (tcMEP) in spinal deformity surgery. Methods:. A retrospective review was conducted on a single surgeon series of 108 consecutive cases utilising the NIM system (Medtronic). Percutaneous needles were employed in the scalp, both hands and feet to allow the upper limbs to act as controls. Forty-nine patients were 13 years old or less, 47 were 14–18, and 12 adults. The cohort consisted of 54 AIS, 27 neuromuscular scoliosis, 14 congenital, 2 old TB and 11 miscellaneous. The vast majority were posterior based procedures. Results:. In 4 cases initial traces could not be obtained. One was a severe myelopathy and further efforts to monitor were abandoned. In one case the anaesthetist had broken protocol and once converted to TIVA the traces improved. Two others were poor initially but improved as the case progressed. In 8 cases intra-operative traces were lost. One was thought to be due to hypothermia and the patient woke intact. Two were unrelated to surgical intervention and recovered spontaneously with patients waking intact. Four cases deteriorated during the corrective manoeuvre (one delayed) and recovered with reduction of correction. One case required removal of instrumentation after repeated loss each time rods were inserted and awoke with a weak leg but recovered and was re-operated two weeks later. Conclusion:. Surgeon operated tcMEP's allows feedback in terms of safety of deformity correction with a 100% negative predictive value and an 8% incidence of signal loss during correction allowing immediate remedial action


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 37 - 37
1 Mar 2013
Hardcastle P Dunn R
Full Access

Purpose of study. The aim is to assess the use of non-fusion instrumentation “growth rods” in early onset scoliosis (EOS). Methods. A retrospective review of 12 consecutive patients who had undergone a growth rod procedure for EOS was performed. Six patients had neuromuscular scoliosis, 5 had juvenile idiopathic scoliosis while one had a congenital aetiology. Growth constructs were predominately constructed from modular commercially available sets using hooks, screws and connection blocks. One VEPTR was used in a severe kyphoscoliosis. Patients returned to theatre at 6 monthly intervals for a lengthening procedure. Patients were assessed with regards to age at presentation, age at surgery, indications for surgery, initial Cobb angle, post- operative Cobb angle, number of lengthening's done, instrumentation used, amount of spine growth achieved and complications. Results. The average age at presentation was 3 yrs 8 months (birth – 7 years 5 months). The average Cobb angle was 55 (38–90). Age at index surgery ranged from 2yrs 9 months to 8 years 2 months. The Cobb angle after the first procedure averaged 37 (range 20–90). The average lengthening over 51 lengthening procedures was 8 mm. Four patients have reached the end of the process and under gone a definitive fusion with pedicle screws and growth rods. Their final Cobb angle averaged 32 (26–48). Definitive surgery was performed earlier than planned in one patient due to repetitive rod breakage. Lengthening was abandoned in one patient whose implants became septic and required removal. Two patients required revision for superior construct failure. Conclusion. The growth rod procedure allows spinal deformity correction and control as well as on-going growth in trunk height. It is a labour intensive process with a significant incidence of complications. There is however very little choice in these patients due to concerns of fusion restricting pulmonary development. NO DISCLOSURES