Advertisement for orthosearch.org.uk
Results 1 - 20 of 44
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 884 - 893
1 Jul 2022
Kjærvik C Gjertsen J Stensland E Saltyte-Benth J Soereide O

Aims

This study aimed to identify risk factors (patient, healthcare system, and socioeconomic) for mortality after hip fractures and estimate their relative importance. Further, we aimed to elucidate mortality and survival patterns following fractures and the duration of excess mortality.

Methods

Data on 37,394 hip fractures in the Norwegian Hip Fracture Register from January 2014 to December 2018 were linked to data from the Norwegian Patient Registry, Statistics Norway, and characteristics of acute care hospitals. Cox regression analysis was performed to estimate risk factors associated with mortality. The Wald statistic was used to estimate and illustrate relative importance of risk factors, which were categorized in modifiable (healthcare-related) and non-modifiable (patient-related and socioeconomic). We calculated standardized mortality ratios (SMRs) comparing deaths among hip fracture patients to expected deaths in a standardized reference population.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1392 - 1398
3 Oct 2020
Zhao Y Tang X Yan T Ji T Yang R Guo W

Aims. There is a lack of evidence about the risk factors for local recurrence of a giant cell tumour (GCT) of the sacrum treated with nerve-sparing surgery, probably because of the rarity of the disease. This study aimed to answer two questions: first, what is the rate of local recurrence of sacral GCT treated with nerve-sparing surgery and second, what are the risk factors for its local recurrence?. Methods. A total of 114 patients with a sacral GCT who underwent nerve-sparing surgery at our hospital between July 2005 and August 2017 were reviewed. The rate of local recurrence was determined, and Kaplan-Meier survival analysis carried out to evaluate the mean recurrence-free survival. Possible risks factors including demographics, tumour characteristics, adjuvant therapy, operation, and laboratory indices were analyzed using univariate analysis. Variables with p < 0.100 in the univariate analysis were further considered in a multivariate Cox regression analysis to identify the risk factors. Results. The rate of local recurrence of sacral GCT treated with nerve-sparing surgery was 28.95% (33/114). Multivariate Cox regression analysis showed that large tumour size (> 8.80 cm) (hazard ratio (HR) 3.16; 95% confidence interval (CI) 1.27 to 7.87; p = 0.014), high neutrophil-to-lymphocyte ratio (NLR) (> 2.09) (HR 3.13; 95% CI 1.28 to 7.62; p = 0.012), involvement of a sacroiliac joint (HR 3.09; 95% CI 1.06 to 9.04; p = 0.039), and massive intraoperative blood loss (> 1,550 ml) (HR 2.47; 95% CI 1.14 to 5.36; p = 0.022) were independent risk factors for local recurrence. Conclusion. Patients with a sacral GCT who undergo nerve-sparing surgery have a local recurrence rate of 29%. Large tumour size, high NLR, involvement of a sacroiliac joint, and massive intraoperative blood loss are independent risk factors. Cite this article: Bone Joint J 2020;102-B(10):1392–1398


Bone & Joint Open
Vol. 4, Issue 12 | Pages 932 - 941
6 Dec 2023
Oe K Iida H Otsuki Y Kobayashi F Sogawa S Nakamura T Saito T

Aims. Although there are various pelvic osteotomies for acetabular dysplasia of the hip, shelf operations offer effective and minimally invasive osteotomy. Our study aimed to assess outcomes following modified Spitzy shelf acetabuloplasty. Methods. Between November 2000 and December 2016, we retrospectively evaluated 144 consecutive hip procedures in 122 patients a minimum of five years after undergoing modified Spitzy shelf acetabuloplasty for acetabular dysplasia including osteoarthritis (OA). Our follow-up rate was 92%. The mean age at time of surgery was 37 years (13 to 58), with a mean follow-up of 11 years (5 to 21). Advanced OA (Tönnis grade ≥ 2) was present preoperatively in 16 hips (11%). The preoperative lateral centre-edge angle ranged from -28° to 25°. Survival was determined by Kaplan-Meier analysis, using conversions to total hip arthroplasty as the endpoint. Risk factors for joint space narrowing less than 2 mm were analyzed using a Cox proportional hazards model. Results. The mean Merle d'Aubigné clinical score improved from 11.6 points (6 to 17) preoperatively to 15.9 points (12 to 18) at the last follow-up. The survival rates were 95% (95% confidence interval (CI) 91 to 99) and 86% (95% CI 50 to 97) at ten and 15 years. Multivariate Cox regression identified three factors associated with radiological OA progression: age (hazard ratio (HR) 2.85, 95% CI 1.05 to 7.76; p = 0.0398), preoperative joint space (HR 2.41, 95% CI 1.35 to 4.29; p = 0.0029), and preoperative OA (HR 8.34, 95% CI 0.94 to 73.77; p = 0.0466). Conclusion. Modified Spitzy shelf acetabuloplasty is an effective joint-preserving surgery with a wide range of potential indications. Cite this article: Bone Jt Open 2023;4(12):932–941


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 58 - 58
23 Feb 2023
Rahardja R Love H Clatworthy M Young S
Full Access

The optimal method of tibial fixation when using a hamstring tendon autograft in anterior cruciate ligament (ACL) reconstruction is unclear. This study aimed to compare the risk of revision ACL reconstruction between suspensory and interference devices on the tibial side. Prospective data on primary ACL reconstructions recorded in the New Zealand ACL Registry between April 2014 and December 2019 were analyzed. Only patients with a hamstring tendon autograft fixed with a suspensory device on the femoral side were included. The rate of revision ACL reconstruction was compared between suspensory and interference devices on the tibial side. Univariate Chi-Square test and multivariate Cox regression was performed to compute hazard ratios (HR) and 95% confidence intervals (CI) with adjustment for age, gender, time-to-surgery, activity at the time of injury, number of graft strands and graft diameter. 6145 cases were analyzed, of which 59.6% were fixed with a suspensory device on the tibial side (n = 3662), 17.6% fixed with an interference screw with a sheath (n = 1079) and 22.8% fixed with an interference screw without a sheath (n = 1404). When compared to suspensory devices (revision rate = 3.4%), a higher risk of revision was observed when using an interference screw with a sheath (revision rate = 6.2%, adjusted HR = 2.05, 95% CI 1.20 – 3.52, p = 0.009) and without a sheath (revision rate = 4.6%, adjusted HR = 1.81, 95% CI 1.02 – 3.23, p = 0.044). The number of graft strands and a graft diameter of ≥8 mm did not influence the risk of revision. When reconstructing the ACL with a hamstring tendon autograft, the use of an interference screw, with or without a sheath, on the tibial side has a higher risk of revision when compared to a suspensory device


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 43 - 43
23 Feb 2023
Bekhit P Coia M Baker J
Full Access

Several different algorithms attempt to estimate life expectancy for patients with metastatic spine disease. The Skeletal Oncology Research Group (SORG) has recently developed a nomogram to estimate survival of patients with metastatic spine disease. Whilst the use of the SORG nomogram has been validated in the international context, there has been no study to date that validates the use of the SORG nomogram in New Zealand. This study aimed to validate the use of the SORG nomogram in Aotearoa New Zealand. We collected data on 100 patients who presented to Waikato Hospital with a diagnosis of spinal metastatic disease. The SORG nomogram gave survival probabilities for each patient at each time point. Receiver Operating Characteristic (ROC) Area Under Curve (AUC) analysis was performed to assess the predictive accuracy of the SORG score. A calibration curve was also performed, and Brier scores calculated. A multivariate Cox regression analysis was performed. The SORG score was correlated with 30 day (AUC = 0.72) and 90-day mortality (AUC = 0.71). The correlation between the SORG score and 90-day mortality was weaker (AUC = 0.69). Using this method, the nomogram was correct for 79 (79%) patients at 30-days, 59 patients (59%) at 90-days, and 42 patients (42%) at 365-days. Calibration curves demonstrated poor forecasting of the SORG nomogram at 30 (Brier score = 0.65) and 365 days (Brier score = 0.33). The calibration curve demonstrated borderline forecasting of the SORG nomogram at 90 days (Brier score = 0.28). Several components of the SORG nomogram were not found to be correlated with mortality. In this New Zealand cohort the SORG nomogram demonstrated only acceptable discrimination at best in predicting life 30-, 90- or 356-day mortality in patients with metastatic spinal disease


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 60 - 60
23 Feb 2023
Rahardja R Love H Clatworthy M Young S
Full Access

Meniscal repairs are commonly performed during anterior cruciate ligament (ACL) reconstruction. This study aimed to identify the risk factors for meniscal repair failure following concurrent primary ACL reconstruction. Primary ACL reconstructions with a concurrent repair of a meniscal tear recorded in the New Zealand ACL Registry between April 2014 and December 2018 were analyzed. Meniscal repair failure was defined as a patient who underwent subsequent meniscectomy, and was identified after cross-referencing data from the ACL Registry with the national database of the Accident Compensation Corporation (ACC). Multivariate Cox regression was performed to produce hazard ratios (HR) with 95% confidence intervals (CI) to identify the patient and surgical risk factors for meniscal repair failure. 2041 meniscal repairs were analyzed (medial = 1235 and lateral = 806). The overall failure rate was 9.4% (n = 192). Failure occurred in 11.1% of medial (137/1235) and 6.8% of lateral (55/806) meniscal repairs. The risk of medial failure was higher with hamstring tendon autografts (adjusted HR = 2.00, 95% CI 1.23 – 3.26, p = 0.006) and in patients with cartilage injury in the medial compartment (adjusted HR = 1.56, 95% CI 1.09 – 2.23, p = 0.015). The risk of lateral failure was higher when the procedure was performed by a surgeon with an annual case volume of less than 30 ACL reconstructions (adjusted HR = 1.92, 95% CI 1.10 – 3.33, p = 0.021). Age, gender, time from injury-to-surgery and femoral tunnel drilling technique did not influence the risk of meniscal repair failure. When repairing a meniscal tear during ACL reconstruction, the use of a hamstring tendon autograft or the presence of cartilage injury in the medial compartment increases the risk of medial meniscal repair failure. Lower surgeon case volume increases the risk of lateral meniscal repair failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 59 - 59
23 Feb 2023
Rahardja R Mehmood A Coleman B Munro J Young S
Full Access

The optimal timing of when to perform manipulation under anesthesia (MUA) for stiffness following total knee arthroplasty (TKA) is unclear. This study aimed to identify the risk factors for MUA following primary TKA and whether performing an “early” MUA within 3 months results in a greater improvement in range of motion. Primary TKAs performed between January 2013 and December 2018 at three tertiary New Zealand hospitals were reviewed. International Classification of Diseases discharge coding was used to identify patients who underwent an MUA. Multivariate Cox regression was performed to identify patient and surgical risk factors for MUA. Pre- and post-MUA knee flexion angles were identified through manual review of operation notes. Multivariate linear regression was performed to compare the mean flexion angles pre- and post-MUA, as well as the mean gain in flexion, between patients undergoing “early” (<3 months) versus “late” MUA (>3 months). 7386 primary TKAs were analyzed in which 131 underwent subsequent MUA (1.8%). Patients aged <65 years were two times more likely to undergo MUA compared to patients aged ≥65 years (2.5% versus 1.3%, adjusted hazard ratio = 2.1, p<0.001). Gender, body mass index, patient comorbidities or a history of cancer were not associated with the risk of MUA. There was no difference in the final post-MUA flexion angle between patients who underwent early versus late MUA (104.7 versus 104.1 degrees, p = 0.819). However, patients who underwent early MUA had poorer pre-MUA flexion (72.3 versus 79.6 degrees, p = 0.012), and subsequently had a greater overall gain in flexion compared to patients who underwent late MUA (mean gain 33.1 versus 24.3 degrees, p<0.001). Younger age was the only patient risk factor for MUA. A greater overall gain in flexion was achieved in patients who underwent early MUA within 3 months


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 56 - 56
23 Feb 2023
Rahardja R Love H Clatworthy M Young S
Full Access

Arthrofibrosis is a less common complication following anterior cruciate ligament (ACL) reconstruction and there are concerns that undergoing early surgery may be associated with arthrofibrosis. The aim of this study was to identify the patient and surgical risk factors for arthrofibrosis following primary ACL reconstruction. Primary ACL reconstructions prospectively recorded in the New Zealand ACL Registry between April 2014 and December 2019 were analyzed. The Accident Compensation Corporation (ACC) database was used to identify patients who underwent a subsequent reoperation with review of operation notes to identify those who had a reoperation for “arthrofibrosis” or “stiffness”. Univariate Chi-Square test and multivariate Cox regression analysis was performed. Hazard ratios (HR) with 95% confidence intervals (CI) were computed to identify the risk factors for arthrofibrosis. 9617 primary ACL reconstructions were analyzed, of which 215 patients underwent a subsequent reoperation for arthrofibrosis (2.2%). A higher risk of arthrofibrosis was observed in female patients (adjusted HR = 1.67, 95% CI 1.22 – 2.27, p = 0.001), patients with a history of previous knee surgery (adjusted HR = 1.97, 95% CI 1.11 – 3.50, p = 0.021) and when a transtibial femoral tunnel drilling technique was used (adjusted HR = 1.55, 95% CI 1.06 – 2.28, p = 0.024). Patients who underwent early ACL reconstruction within 6 weeks of their injury did not have a higher risk of arthrofibrosis when compared to patients who underwent surgery more than 6 weeks after their injury (3.5% versus 2.1%, adjusted HR = 1.56, 95% CI 0.97 – 2.50, p = 0.07). Age, graft type and concomitant meniscal injury did not influence the rate of arthrofibrosis. Female sex, a history of previous knee surgery and a transtibial femoral tunnel drilling technique are risk factors for arthrofibrosis following primary ACL reconstruction


Results in patients undergoing total hip arthroplasty (THA) for femoral head osteonecrosis (ON) when compared with primary osteoarthritis (OA) are controversial. Different factors like age, THA type or surgical technique may affect outcome. We hypothesized that patients with ON had an increased revision rate compared with OA. We analysed clinical outcome, estimated the survival rate for revision surgery, and their possible risk factors, in two groups of patients. In this retrospective cohort analysis of our prospective database, we assessed 2464 primary THAs implanted between 1989 and 2017. Patients with OA were included in group 1, 2090 hips; and patients with ON in group 2, 374 hips. In group 2 there were more men (p<0.001), patients younger than 60 years old (p<0.001) and with greater physical activity (p<0.001). Patients with lumbar OA (p<0.001) and a radiological acetabular shape type B according to Dorr (p<0.001) were more frequent in group 1. Clinical outcome was assessed according to the Harris Hip Score and radiological analysis included postoperative acetabular and femoral component position and hip reconstruction. Kaplan-Meier survivorship analysis was used to estimate the cumulative probability of not having revision surgery for different reasons. Univariate and multivariate Cox regression models were used to assess risk factors for revision surgery. Clinical improvement was better in the ON at all intervals. There were 90 hips revised, 68 due to loosening or wear, 52 (2.5%) in group 1, and 16 (4.3%) in group 2. Overall, the survival rate for revision surgery for any cause at 22 years was 88.0 % (95% CI, 82-94) in group 1 and 84.1% (95% CI, 69 – 99) in group 2 (p=0.019). Multivariate regression analysis showed that hips with conventional polyethylene (PE), compared with highly-cross linked PEs or ceramic-on-ceramic bearings, (p=0.01, Hazard Ratio (HR): 2.12, 95% CI 1.15-3.92), and cups outside the Lewinnek´s safe zone had a higher risk for revision surgery (p<0.001, HR: 2.57, 95% CI 1.69-3.91). Modern highly-cross linked PEs and ceramic-on-ceramic bearings use, and a proper surgical technique improved revision rate in patients undergoing THA due to ON compared with OA


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1261 - 1269
1 Jul 2021
Burger JA Zuiderbaan HA Sierevelt IN van Steenbergen L Nolte PA Pearle AD Kerkhoffs GMMJ

Aims. Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs. Methods. A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed. Results. In hospitals performing less than 100 cases per year, cemented mobile bearings reported comparable adjusted risks of revision as uncemented mobile bearings. However, in hospitals performing more than 100 cases per year, the adjusted risk of revision was higher for cemented mobile bearings compared to uncemented mobile bearings (hazard ratio 1.78 (95% confidence interval 1.34 to 2.35)). The adjusted risk of revision between cemented fixed bearing and uncemented mobile bearing was comparable, independent of annual hospital volume. In addition, 12.3% of uncemented mobile bearing, 20.3% of cemented mobile bearing, and 41.5% of uncemented fixed bearing revisions were for tibial component loosening. The figures for instability were 23.6%, 14.5% and 11.7%, respectively, and for periprosthetic fractures were 10.0%, 2.8%, and 3.5%. Bearing exchange was the type of revision in 40% of uncemented mobile bearing, 24.3% of cemented mobile bearing, and 5.3% cemented fixed bearing revisions. Conclusion. The findings of this study demonstrated improved survival with use of uncemented compared to cemented mobile bearings in medial UKA, only in those hospitals performing more than 100 cases per year. Cemented fixed bearings reported comparable survival results as uncemented mobile bearings, regardless of the annual hospital volume. The high rates of instability, periprosthetic fractures, and bearing exchange in uncemented mobile bearings emphasize the need for further research. Cite this article: Bone Joint J 2021;103-B(7):1261–1269


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims. The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). Patients and Methods. In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors. Results. The revision-free survival of the implant was 71% at five years and 63.3% at ten years. Three prostheses reached 15 years without revision. The mean Musculoskeletal Tumor Society score in the group was 26 (23 to 28). The mechanisms of failure were infection in 18%, structural failures in 6%, tumour progression in 5%, aseptic loosening in 2%, and soft-tissue failures in 1%. Prostheses used for primary reconstruction after oncological resections had lower infection rates than revision implants (8% vs 25%; p = 0.001). The rates of infection in silver-coated and non-silver-coated prosthesis were similar (17.4% vs 19.%; p = 0.869). The incidence of hip dislocation was 10%. Rotating hinge prosthesis had a lower failure rate than fixed hinge prosthesis (5.3% vs 11%). After Cox regression, the independent factors associated with failures were the history of previous operations (hazard ratio (HR) 3.7; p = 0.041), and the associated arthroplasty of the proximal tibia (HR 3.8; p = 0.034). At last follow-up, 11 patients (13%) required amputation. Conclusion. TFEPR offers a reliable reconstruction option for massive bone loss of the femur, with a good survival when the prosthesis is used as a primary implant. The use of a rotating hinge at the knee and dual mobility bearing at the hip may be adequate to reduce the risk of mechanical and soft-tissue failures. Infection remains the main concern and there is insufficient evidence to support the routine use of silver-coated endoprosthesis. Cite this article: Bone Joint J 2019;101-B:522–528


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 119 - 119
1 May 2011
Ruggieri P Pala E Abati C Calabrò T Henderson E Marulanda G Cheong D Letson D Mercuri M
Full Access

Purpose was to evaluate the incidence of complication in lower limb reconstructions with modular prostheses comparing cemented versus uncemented stems in two different orthopedic tumor Centers. Methods: retrospective analysis of implant survival, complications and functional results assessed according to MSTS system of the Rizzoli and Moffitt series of modular megaprosthesis in lower limb. From 2002 and 2007, 238 modular prostheses of same design with a rotating hinge knee, were implanted in the lower limb as primary reconstruction in these two Centers. In 130 cases the prosthesis was implanted with cemented stems and in 108 cases with uncemented stems. Sites included: 120 distal femur, 61 proximal femur, 46 proximal tibia, 10 total femur and in 1 case both distal femur and proximal tibia. Histologic diagnoses included: 89 osteosarcoma, 13 Ewing sarcoma, 21 chondrosarcoma, 19 sarcoma, 55 metastasis, 17 TGC, 7 MFH, 11 other diagnoses and 6 non oncologic cases. Major prostheses-related complications were analysed and functional results according to Muscolo Skeletal Tumor Society system, at a mean follow up of 2.03 yrs. Also a statistical evaluation with Kaplan Meier curves, a comparative statistical analysis with Wilcoxon test and multivariate Cox regression analysis were performed. Results: Outcome in 223 evaluated oncologic pts, showed: 121 pts continuously disease free, 26 NED after treatment of relapse, 54 AWD, 16 DWD. Margins were wide in 94.3% (214/227 pts) of evaluated pts. Complications causing implants failure were: infections in 20/238 (8.41%), aseptic loosening in 7/238 (2.95%). No breakages of prosthetic components were observed. Infections occurred at mean time of 1.3 yrs, sites included: 9 distal femurs, 4 proximal femurs, 5 proximal tibias, 2 total femurs. Aseptic loosening occurred at mean time of 2.3 yrs, sites included: 3 proximal tibias, 2 distal femurs, 2 proximal femurs. Rate of aseptic loosening was higher for cemented stems 5/130 (3.85%) vs uncemented 2/108 (1.85%). This difference is not statistically significant. Infection rate was 10% (13/130) for cemented stems and 6.5% (7/108) for uncemented stems. This difference is statistically significant at comparison of survival curves logrank test. Average MSTS function score was 83.5%. Multivariate Cox regression analysis showed that the significant factor favourable reluted with lower incidence of complications was the use of uncemented stems. Conclusions: lower limb modular prostheses with both cemented and uncemented stems gave good results and a low complication rate. Better results were observed with uncemented stems and statistically confirmed, but this needs to be further investigate in a future study at long term


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 30 - 30
1 Sep 2012
Al-Atassi T Chou D Boulton C Moran C
Full Access

Introduction. Cemented hemiarthroplasty for neck of femur fractures has been advocated over uncemented hemiarthroplasty due to better post-operative recovery and patient satisfaction. However, studies have shown adverse effects of bone cement on the cardio-respiratory system which may lead to higher morbidity and mortality. Therefore, in some institutes, the use of an uncemented prosthesis has been adopted for patients with a high number of co-morbidities. The aim was to compare early mortality rates for cemented vs. uncemented hemiarthroplasties. Method. Cohort study of displaced intracapsular hip fractures treated with hemiarthroplasty between 1999–2009 at one institute. A total of 3094 hemiarthroplasties performed; out of which 1002(32.4%) were cemented and 2092(67.6%) were uncemented. 48hour and 30day mortality rates for the two groups were compared and a multivariate Cox regression model used to eliminate confounding factors. Significant confounding factor included age, sex, mini mental test score, medical co-morbidities, Nottingham Hip Fracture Score and delay to surgery. Results. The study showed that, after eliminating confounding factors, 48hour mortality in the cemented group was 0.3% compared to 0.5% in the uncemented group (p=0.388). However, the adjusted 30day mortality rate for the cemented group (4%) was shown to be significantly lower than for the uncemented group (10.8%) (p< 0.001). Conclusion. The use of cement in hip hemiarthroplasty is not associated with an increased rate of mortality at 48hours or at 30days. Along with emerging evidence of better post-op recovery and patient satisfaction with the use of a cemented prosthesis, we support the use of cement for all patients undergoing hip hemiarthroplasty


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 140 - 140
1 May 2011
Wibmer C Leithner A Hofmann G Clar H Kapitan M Berghold A Windhager R
Full Access

Objective: Metastases in the spinal column are a common manifestation of advanced cancer disease. Severe pain, pathologic fracture and neurologic deficit due to spinal metastases need adequate treatment. Considering oncologic aspects as well as quality of life, treatment decision should also include prediction of the survival period. In this study we analysed the scoring systems of Bauer, Bauer modified, Tokuhashi, Tokuhashi revised, Tomita, van der Linden and Sioutos, as well as the parameters they consist of, for their predictive value. Methods: Two-hundred and fifty four patients with confirmed spinal metastases were investigated retrospectively (treatment 1998–2006; 62 received surgery, 189 only conservative therapy). The following factors were analysed: primary tumor, general condition (Kar-nofsky Performance Scale), neurological deficit, number of spinal and extraspinal bone metastases, visceral metastases, pathologic fracture. Survival period was calculated from date of diagnosis of the spinal metastases until date of death or last follow up (minimum follow-up: 12 months). For statistical analysis univariate and stepwise multivariate Cox regression analyses were performed. Results: Median overall survival for all patients was 10.6 months. The following factors showed significant influence on survival in multivariate analysis: primary tumor (p< 0.0001), status of visceral metastases (p< 0.0001), and systemic therapy (p< 0.0001). Cox regression proved all scores significant in metric analysis. Distinguishing between the prognostic subgroups, only Bauer and Bauer modified showed significant results for this classification into good, moderate and poor prognosis. The other systems failed to distinguish significantly between good and moderate prognosis. Conclusion: In our collective, Bauer and Bauer modified score prove to be the most reliable systems for predicting survival. We therefore want to propose the Bauer modified score (consisting of only four positive prognostic factors, excluding pathologic fracture) as valid for predicting survival and practicable for clinical use


Bone & Joint Open
Vol. 5, Issue 4 | Pages 350 - 360
23 Apr 2024
Wang S Chen Z Wang K Li H Qu H Mou H Lin N Ye Z

Aims

Radiotherapy is a well-known local treatment for spinal metastases. However, in the presence of postoperative systemic therapy, the efficacy of radiotherapy on local control (LC) and overall survival (OS) in patients with spinal metastases remains unknown. This study aimed to evaluate the clinical outcomes of post-surgical radiotherapy for spinal metastatic non-small-cell lung cancer (NSCLC) patients, and to identify factors correlated with LC and OS.

Methods

A retrospective, single-centre review was conducted of patients with spinal metastases from NSCLC who underwent surgery followed by systemic therapy at our institution from January 2018 to September 2022. Kaplan-Meier analysis and log-rank tests were used to compare the LC and OS between groups. Associated factors for LC and OS were assessed using Cox proportional hazards regression analysis.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 117 - 118
1 Mar 2009
Luetzner J Krummenauer F Luebke J Bottesi M
Full Access

Purpose: Although arthroscopic Bankart repair is yet an established procedure in the treatment of traumatic anterior shoulder instability, it is still not known whether it reproduces the good results of the open repair procedure. Aim of this investigation was to compare the functional and subjective outcome between open and arthroscopic Bankart repair. Material and methods: A retrospective cross sectional study design on the comparison of open and arthoscopic Bankart treatments between 1995 and 2004 was implemented at the Dresden Orthopedic Surgery Department. In this period a total of 223 patients underwent surgery due to anterior shoulder instability, among which 212 patients had posttraumatic instability. A diagnostic arthroscopy was performed in all patients, but only 40 patients with intact capsulolabral complex and without capsular laxity were treated arthroscopically, the remaining 183 patients underwent an open Bankart procedure. A total of 186 patients with posttraumatic anterior instability could be clinically re-examined within 1 to 5 years after initial surgery, among which 147 patients underwent an open and 39 patients an arthroscopic Bankart procedure. The median age of this sample was 27 years (interquartile range 21 – 37 years) at initial surgery, 21% of these patients were female. Results: After open surgery 11 of 147 patients (8%) and 6 of 39 (15%) after arthroscopic surgery reported one or more re-dislocation after initial treatment, which occurred after a mean dislocation free time of 62 versus 40 months, respectively (95% confidence intervals 59 – 65 versus 36 – 44 months). Both a univariate analysis (Logrank test p=0.012) and a multivariate Cox regression analysis (Likelihood Ratio p=0.023) confirmed a statistically significant difference in the time between initial surgery to first reluxation. 4 of the 11 re-dislocations after open and 1 of 6 after arthroscopic surgery occurred after a new accident. That makes a re-dislocation rate without new adequate trauma of 5% after open and 13% after arthroscopic treatment. ROM showed no difference between open and arthroscopic Bankart procedure for abduction and a mild difference for external rotation. 21 of 115 (18%) patients had an external rotation lag of 20° or more after open surgery versus 1 of 34 (3%) after arthroscopic treatment (Fisher p=0,027). The Rowe score demonstrated “good” or “excellent” functional results in 102 of 117 (87%) patients versus 28 of 35 (80%) patients after open versus arthroscopic treatment (Fisher p=0,285). Conclusion: In this sample arthroscopic Bankart repair demonstrated more frequently and significantly earlier re-dislocation after initial surgery than did the open treatment alternative. External rotation lags of at least 20° occured more frequently after the open procedure


Bone & Joint 360
Vol. 13, Issue 5 | Pages 44 - 47
1 Oct 2024

The October 2024 Children’s orthopaedics Roundup360 looks at: Cost-effectiveness analysis of soft bandage and immediate discharge versus rigid immobilization in children with distal radius torus fractures: the FORCE trial; Percutaneous Achilles tendon tenotomy in clubfoot with a blade or a needle: a single-centre randomized controlled noninferiority trial; Treatment of hip displacement in children with cerebral palsy: a five-year comparison of proximal femoral osteotomy and combined femoral-pelvic osteotomy in 163 children; The Core outcome Clubfoot (CoCo) study: relapse, with poorer clinical and quality of life outcomes, affects 37% of idiopathic clubfoot patients; Retention versus removal of epiphyseal screws in paediatric distal tibial fractures: no significant impact on outcomes; Predicting the resolution of residual acetabular dysplasia after brace treatment in infant DDH; Low prevalence of acetabular dysplasia following treatment for neonatal hip instability: a long-term study; How best to distract the patient?.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 189 - 194
1 Feb 2024
Donald N Eniola G Deierl K

Aims

Hip fractures are some of the most common fractures encountered in orthopaedic practice. We aimed to identify whether perioperative hypotension is a predictor of 30-day mortality, and to stratify patient groups that would benefit from closer monitoring and early intervention. While there is literature on intraoperative blood pressure, there are limited studies examining pre- and postoperative blood pressure.

Methods

We conducted a prospective observational cohort study over a one-year period from December 2021 to December 2022. Patient demographic details, biochemical results, and haemodynamic observations were taken from electronic medical records. Statistical analysis was conducted with the Cox proportional hazards model, and the effects of independent variables estimated with the Wald statistic. Kaplan-Meier survival curves were estimated with the log-rank test.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 203 - 211
1 Feb 2024
Park JH Won J Kim H Kim Y Kim S Han I

Aims

This study aimed to compare the performance of survival prediction models for bone metastases of the extremities (BM-E) with pathological fractures in an Asian cohort, and investigate patient characteristics associated with survival.

Methods

This retrospective cohort study included 469 patients, who underwent surgery for BM-E between January 2009 and March 2022 at a tertiary hospital in South Korea. Postoperative survival was calculated using the PATHFx3.0, SPRING13, OPTIModel, SORG, and IOR models. Model performance was assessed with area under the curve (AUC), calibration curve, Brier score, and decision curve analysis. Cox regression analyses were performed to evaluate the factors contributing to survival.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 210 - 217
13 Mar 2024
Mthethwa PG Marais LC Aldous CM

Aims

The aim of this study is to determine the predictors of overall survival (OS) and predictive factors of poor prognosis of conventional high-grade osteosarcoma of the limbs in a single-centre in South Africa.

Methods

We performed a retrospective cross-sectional analysis to identify the prognostic factors that predict the OS of patients with histologically confirmed high-grade conventional osteosarcoma of the limbs over ten years. We employed the Cox proportional regression model and the Kaplan-Meier method for statistical analysis.