Aims. Currently, the most common approach for the management of a chronic PJI is a Two-Stage Replacement; because of success rates exceeding 90% when using an antibiotic impregnated cement spacer. Reliable information regarding the etiologic
Aims. The aim of this study was to evaluate the diagnostic value of preoperative serum CRP, white blood cell count (WBC), percentage of neutrophils (%N), and neutrophil to lymphocyte ratio (NLR) when using the fracture-related infection (FRI) consensus definition. Methods. A cohort of 106 patients having surgery for suspected septic nonunion after failed fracture fixation were studied. Blood samples were collected preoperatively, and the concentration of serum CRP, WBC, and differential cell count were analyzed. The areas under the curve (AUCs) of diagnostic tests were compared using the z-test. Regression trees were constructed and internally cross-validated to derive a simple diagnostic decision tree. Results. Using the FRI consensus definition, 46 patients (43%) were identified as infected. Sensitivity, specificity, and AUC of CRP were 67% (95% confidence interval (CI) 52% to 80%), 61% (95% CI 47% to 74%), and 0.64 (95% CI 0.54 to 0.74); of WBC count were 17% (95% CI 9% to 31%), 95% (95% CI 86% to 99%), and 0.57 (95% CI 0.50 to 0.62); of %N 13% (95% CI 6% to 26%), 87% (95% CI 76% to 93%), and 0.50 (95% CI 0.43 to 0.56); and of NLR 28% (95% CI 17% to 43%), 80% (95% CI 68% to 88%), and 0.54 (95% CI 0.46 to 0.63), respectively. A better performance of serum CRP was shown in comparison to the leucocyte count (p = 0.006), %N (p < 0.001), and NLR (p = 0.001). A statistically lower serum CRP level was shown in patients with an infection caused by a low virulence
Fracture-related infections (FRIs) are a devastating complication of fracture management. However, the impact of FRIs on mental health remains understudied. The aim of this study was a longitudinal evaluation of patients’ psychological state, and expectations for recovery comparing patients with recurrent FRI to those with primary FRI. A prospective longitudinal study was conducted at a level 1 trauma centre from January 2020 to December 2022. In total, 56 patients treated for FRI were enrolled. The ICD-10 symptom rating (ISR) and an expectation questionnaire were assessed at five timepoints: preoperatively, one month postoperatively, and at three, six, and 12 months.Aims
Methods
This study aimed to investigate the clinical characteristics and outcomes associated with culture-negative limb osteomyelitis patients. A total of 1,047 limb osteomyelitis patients aged 18 years or older who underwent debridement and intraoperative culture at our clinic centre from 1 January 2011 to 31 December 2020 were included. Patient characteristics, infection eradication, and complications were analyzed between culture-negative and culture-positive cohorts.Aims
Methods
Infection rates following arthroplasty surgery are between 1–4%, with higher rates in revision surgery. The associated costs of treating infected arthroplasty cases are considerable, with significantly worse functional outcomes reported. New methods of infection prevention are required. HINS-light is a novel blue light inactivation technology which kills bacteria through a photodynamic process. The aim of this study was to investigate the efficacy of HINS-light for the inactivation of bacteria isolated from infected arthoplasty cases. Specimens from hip and knee arthroplasty infections are routinely collected to identify causative organisms. This study tested a range of these isolates for sensitivity to HINS-light. During testing, bacterial suspensions were exposed to increasing doses of HINS-light of (123mW/cm2 irradiance). Non-light exposed control samples were also set-up. Bacterial samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration. Complete inactivation was achieved for all Gram positive and negative
Prosthetic joint infection is one of the most challenging complications of joint alloplasty and the diagnosis remains difficult. The aim of the study was to investigate the bacterial flora in surgical samples from 22 prosthetic patients using a panel of culture-independent molecular methods including broad range 16S rRNA gene PCR, cloning, sequencing, phylogeny, quantitative PCR (qPCR), and fluorescence in situ hybridization (FISH). Concomitant samples were cultured by standard methods. Molecular methods detected presence of bacteria in samples from 12 of 22 patients. Using clone libraries a total of 40 different bacterial species were identified including known pathogens and species not previously described in association with prosthetic joint infections. The predominant species were Propionibacterium acnes and Staphylococcus epidermidis; polymicrobial infections were found in 9 patients. Culture-based methods showed bacterial growth in 8 cases with the predominant species being S. epidermidis. Neither anaerobic bacteria (including P. acnes) nor any of the species not previously described in implant infections were isolated. Additionally, 7 of the 8 culture positive cases were monomicrobial. Overall, the results of culture-based and molecular methods showed concordance in 11 cases (hereof 9 negative by both methods) and discrepancy in 6 cases. In the remaining 5 cases, culture-based methods identified only one species or a group of bacteria (e.g., coagulase negative staphylococci or coryneform rods), while culture-independent molecular methods were able to detect several distinct bacterial species including a species within the group identified by culture. A qPCR assay was developed to assess the abundance of Propionibacterium while S. aureus was quantified by a published S. aureus qPCR assay. These quantifications confirmed the findings from the clone library approach and showed the potential of qPCR for fast detection of bacteria in orthopedic samples. Additionally, both single cells and microcolonies were visualized using FISH and confocal scanning laser microscopy. In conclusion, the molecular methods detected a more diverse bacterial flora in prosthetic joint infections than revealed by standard culture-based methods, and polymicrobial infections were more frequently observed. The pathogenesis of these
Objective. To assess the beneficial use of polypropylene mesh impregnated with vancomycin in an experimental model open fractures Gustilo IIIa in rabbits. Material and Method. We worked with 15 New Zeland White rabbits. All of them were carried out under general anaesthetic, a 5-cm incision longitudinal was made at the back of the right thigh. The femur was aproached and a fracture was performed with a shear, giving rise to a multifragment fracture. The wound remained open for 6 hours with the bone exposed, in a non-surgical ambient. Subsequently underwent surgical cleaning of the open fractures in two stages. The fracture was stabilized with an intramedular pin. The animals were sorted in 3 different therapeutic groups:. Group 1: (5 rabbits) without other treatment. Group 2: (5 rabbits) a polypropylene mesh was placed around the fracture. Group 3: (5 rabbits) a polypropylene mesh with vancomycin was placed around the fracture. The wound was closed with nylon stiches. Three weeks postoperative, the animals were intervened surgically under general anesthesia, after aseptic cure and placement of surgical fields, femoral bone biopsies, soft tissue and mesh were taken. The rabbits were sacrified. The samples were sent to pathology and bacteriology labs. Results. The bacteria isolated were as follows: Escherichia coli, Pasteurella multocida, Staphylococcus spp., Clostridium spp. Mamheinia spp. The Clostridium spp. is a common contaminant in the exposed fractures present in the environment. The Pasteurella mustocida is a
Background. Both from experimental studies and the large arthroplasty registries there is evidence that bacteria are more often involved in implant loosening then is currently reported. To further elucidate this potential problem, the current study investigated the hypothesis that many total hip arthroplasty revisions, classified as aseptic, are in fact low-grade infections missed with routine diagnostics. Methods. In 7 Dutch hospitals, 176 patients with the preoperative diagnosis of aseptic loosening of their total hip arthroplasty were enrolled. From each patient, the preoperative history was obtained. During surgery, between 14 and 20 tissue samples were obtained for routine culture, pathology analysis and broad range 16S rRNA PCR with reverse line blot hybridization (PCR-RLB). Samples were taken from the (neo-) capsule and acetabular and femoral interface tissue. Cultures were performed locally according to similar protocols. One specialized pathologist, blinded for all other results, analyzed all pathology samples. The PCR-RLB analysis was performed centrally, using a technique previously validated for orthopedic use. Patients were classified as not infected, suspect for infection or infected, according to strict, predefined criteria. Each patient had a follow-up visit after 1 year. Results. Seven patients were classified as infected, of whom 4 were not identified by routine culture. In these patients, positive PCR-RLB results were supported by pathology analyses suspect for infection as well. An additional 15 patients were suspect for infection as well. The
The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded.Aims
Methods
This study aimed to investigate the role of quantitative histological
analysis in the diagnosis of fracture-related infection (FRI). The clinical features, microbiology culture results, and histological
analysis in 156 surgically treated nonunions were used to stratify
the likelihood of associated infection. There were 64 confirmed
infected nonunions (one or more confirmatory criteria: pus, sinus,
and bacterial growth in two or more samples), 66 aseptic nonunions
(no confirmatory criteria), and 26 possibly infected nonunions (pathogen
identified from a single specimen and no confirmatory criteria).
The histological inflammatory response was assessed by average neutrophil
polymorph (NPs) counts per high-power field (HPF) and compared with
the established diagnosis.Aims
Patients and Methods
Deep bone and joint infections (DBJI) are directly intertwined with health, demographic change towards an elderly population, and wellbeing. The elderly human population is more prone to acquire infections, and the consequences such as pain, reduced quality of life, morbidity, absence from work and premature retirement due to disability place significant burdens on already strained healthcare systems and societal budgets. DBJIs are less responsive to systemic antibiotics because of poor vascular perfusion in necrotic bone, large bone defects and persistent biofilm-based infection. Emerging bacterial resistance poses a major threat and new innovative treatment modalities are urgently needed to curb its current trajectory. We present a new biphasic ceramic bone substitute consisting of hydroxyapatite and calcium sulphate for local antibiotic delivery in combination with bone regeneration. Gentamicin release was measured in four setups: 1) Objectives
Materials and Methods