Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 69 - 69
1 Dec 2020
LI Y LI L FU D
Full Access

Objective. To analyze the short-term outcome after medial open-wedge high tibial osteotomy with a 3D-printing technology in early medial keen osteoarthritis and varus malalignment. Design and Method. 32 knees(28 cases) of mOWHTO (fixation with an angular-stable TomoFix implant(Synthes)) with a 3D-printing technology combined with arhtroscopy were prospectively surveyed with regard to functional outcome(Hospital for special knee score [HSS] score). Pre- and postoperative tibial bone varus angle (TBVA), mechanical medial proximal tibial angle (MPTA), and alignment were analyzed with regard to the result. Results. 32 knees were included (28 patients; mean age 46.5±9.3 years). The follow-up rate was 100% at 1.7±0.6 years (range, 1.2–3.2 years). Pre- and postoperative mechanical tibiofemoral axis were 6.8°±2°of varus and 1.2°± 3.4° of valgus, respectively. HSS score significantly improved from 46.0±18.3 preoperatively to 84±12 at one, 80±7 at two years (P<0.01). Conclusions. Medial open-wedge high tibial osteotomy with a 3D-printing technology combined with arthroscopy in medial keen osteoarthritis and varus malalignment is an accurate and good treatment option. High preoperative TBVA and appropriate corrected angle(0–3° of valgus)) was associated with better functional outcome at final follow-up


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 57 - 57
1 Mar 2021
Walker R Rye D Yoong A Waterson B Phillips J Toms A
Full Access

Abstract. Background. Lower limb mechanical axis has long been seen as a key to successful in lower limb surgery, including knee arthroplasty. Traditionally, coronal alignment has been assessed with weight-bearing lower limb radiographs (LLR) allowing assessment of hip-knee-ankle alignment. More recently CT scanograms (CTS) have been advocated as a possible alternative, having the potential benefits of being quicker, cheaper, requiring less specialist equipment and being non-weightbearing. Objectives. To evaluate the accuracy and comparability of lower limb alignment values derived from LLR versus CTS. Methods. We prospectively investigated patients undergoing knee arthroplasty with preoperative and postoperative LLR and CTS, analysing both preoperative and postoperative LLRs & CTS giving 140 imaging tests for direct comparison. We used two independent observers to calculate on each of imaging modalities, on both pre- and post-operative images, the: hip-knee-ankle alignment (HKA), lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA). Results. 840 data points were captured from pre- and post-operative LLRs and CTSs. Analysis demonstrated very strong correlation in pre-operative HKA (LLR vs CTS, r = 0.917), post-operative HKAs (LLR vs CTS, 0.850) and postoperative LDFAs (LLR vs CTS, 0.850). Strong correlation was observed in pre-operative LDFAs (0.732), MPTAs (0.604), and post-operative MPTAs (0.690). Conclusion. Both pre- and post-operative LLR and CTS imaging display very strong correlation for HKA coronal alignment correlation, with strong correlation for other associated angles around the knee. Our results demonstrate that both LLR and CTS can be used interchangeably with similar results. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 31 - 31
1 Apr 2017
Meijer M Boerboom A Bulstra S Reininga I Stevens M
Full Access

Background. Achieving optimal prosthesis alignment during total knee arthroplasty (TKA) is essential. Imageless computer-assisted surgery (CAS) is developed to improve knee prosthesis alignment and with CAS it is possible to perform intraoperative alignment measurements. Lower limb alignment measurements are also performed for preoperative planning and postoperative evaluation. A new stereoradiography system, called EOS, can be used to perform these measurements in 3D and thus measurement errors due to malpositioning can be eliminated. Since both CAS and EOS are based on 3D modeling, measurements should theoretically correlate well. Therefore, objective was to compare intraoperative CAS-TKA measurements with pre- and postoperative EOS 3D measurements. Methods. In a prospective study 56 CAS-TKAs were performed and alignment measurements were recorded two times: before bone cuts were made and after implantation of the prosthesis. Pre- and postoperative coronal alignment measurements were performed using EOS 3D. CAS measurements were compared with EOS 3D reconstructions. Measured angles were: varus/valgus (VV), mechanical lateral distal-femoral (mLDFA) and medial proximal tibial angle (mMPTA). Results. Significantly different VV angles were measured pre- and postoperatively with CAS compared to EOS. For preoperative measurements, mLDFA did not differ significantly, but a significantly larger mMPTA in valgus was measured with CAS. Conclusions. EOS 3D measurements overestimate VV angle in lower limbs with substantial mechanical axis deviation. For lower limbs with minor mechanical axis deviation as well as for mMPTA measurements, CAS measures more valgus compared to EOS. Results of this study indicate that differences in alignment measurements between CAS measurements and pre- and postoperative EOS 3D are mainly due to the difference between weight bearing and non-weight bearing position and potential errors in validity and reliability of the CAS system. Surgeons should be aware of these measurement differences and the pitfalls of both measurement techniques. Level of evidence. IIb. Disclosures. The department of Orthopaedics, University of Groningen, University Medical Center Groningen receives research institutional support from InSpine (Schiedam, NL) and Stryker (Kalamazoo, Mich. USA). One of the authors (ALB) will be and has been paid as a consultant by Zimmer (Warsaw, IN, USA) for purposes of education and training in knee arthroplasty


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 286 - 286
1 Jul 2014
Lee J Jeong C
Full Access

Summary Statement. The implantation of scaffold-free CTE from suspension culture into growth-plate defects resulted in a significant reduction in growth arrest of the rabbit tibia. Introduction. In childhood and adolescence, the growth plate injury can cause partial premature arrest of growth plate, which can make problems such as leg length discrepancy and angular deformity. Bone bridge resection and variable implantation materials such as fat, bone wax, silastic and craniopalst has been investigated. However, those procedures may show limitations including the control of bone growth and long term safety of implant materials in vivo. As an alternative, homogeneous or heterogeneous cartilage cells and stem cell transplants have been tried. In this method, scaffold for cell transplantation is needed. But, so far the most suitable scaffold has not been established. Recently, some authors generated a cartilage tissue equivalent (CTE) using a suspension culture with biophysical properties similar to native hyaline cartilage. Therefore we are able to transplant the CTE without scaffold to the physeal defect. The purpose of this study was to investigated the effects of a transplantation of a vitro-generated scaffold-free tissue-engineered cartilage tissue equivalent (CTE) using a suspension chondrocyte culture in a rabbit growth arrest model. Material and Method. Cartilage tissue equivalent culture. The CTE was generated by the suspension culture of chondrocytes (2 × 10. 7. /well/1 mL) which was isolated from articular cartilage of 5 weeks New Zealand white rabbit on a 24-well plate (2.4 cm. 2. /well) treated with poly HEMA (nunc, Roskide, Denmark) for up to 8 and 16 weeks. (2)Partial growth arrest animal model. An experimental model for growth arrest was created by excising the growth plate at the proximal medial side of tibia with the 4 mm in diameter and 4 mm in depth from 6-week-old New Zealand white rabbits. Two experimental groups were set to evaluate CTE implantation; group I, no implantation as controls; group II, implantation of CTE. (3) Evaluation of effect of the transplantation of CTE. Serial plain radiographs were performed at one week. The medial proximal tibial angle (MPTA) was measured for assessing the degree of angular deformity. Histologic examination using HE stain, Alcian bule and immunohistochemistry was done at 4 and 8 weeks after surgery. Results. Radiographic results: In group I, all damaged growth plates were arrested and angular deformities appeared 4 weeks later. In groups II, angular deformities were much less than in the control group. Histologic result: In group I, bone bridge formation was shown at the damaged growth plate at 4 weeks after surgery. In group II, regeneration of growth plates was recognised at 4 and 8 week after surgery. However, the thickness of regenerated growth plate at 8 weeks specimen was thinner than that of 4 weeks specimen. Discussion and Conclusion. The implantation of scaffold-free CTE from suspension culture into growth-plate defects resulted in a significant reduction in growth arrest of the rabbit tibia


Bone & Joint Research
Vol. 5, Issue 1 | Pages 1 - 10
1 Jan 2016
Burghardt RD Manzotti A Bhave A Paley D Herzenberg JE

Objectives

The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method.

Methods

In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 120 - 125
1 Jan 2011
Lim H Bae J Song H Teoh SH Kim H Kum D

Medial open-wedge high tibial osteotomy has been gaining popularity in recent years, but adequate supporting material is required in the osteotomy gap for early weight-bearing and rapid union. The purpose of this study was to investigate whether the implantation of a polycaprolactone-tricalcium phosphate composite scaffold wedge would enhance healing of the osteotomy in a micro pig model. We carried out open-wedge high tibial osteotomies in 12 micro pigs aged from 12 to 16 months. A scaffold wedge was inserted into six of the osteotomies while the other six were left open. Bone healing was evaluated after three and six months using plain radiographs, CT scans, measurement of the bone mineral density and histological examination.

Complete bone union was obtained at six months in both groups. There was no collapse at the osteotomy site, loss of correction or failure of fixation in either group. Staining with haematoxylin and eosin demonstrated that there was infiltration of new bone tissue into the macropores and along the periphery of the implanted scaffold in the scaffold group. The CT scans and measurement of the bone mineral density showed that at six months specimens in the scaffold group had a higher bone mineral density than in the control group, although the implantation of the polycaprolactone-tricalcium phosphate composite scaffold wedge did not enhance healing of the osteotomy.