Background. Both from experimental studies and the large arthroplasty registries there is evidence that bacteria are more often involved in implant loosening then is currently reported. To further elucidate this potential problem, the current study investigated the hypothesis that many total hip arthroplasty revisions, classified as aseptic, are in fact
Understanding the cause of failure of total knee arthroplasties (TKA) is essential in guiding clinical decision making and adjusting treatment concepts for revision surgery. The purpose of the study was to determine current mechanisms of failure of TKA and to describe changes and trends in revision surgery over the last 10 years. A retrospective review was done on all patients who had revision total knee arthroplasty during a 10-year period (2000–2009) at one institution. The preoperative evaluation in conjunction with the intraoperative findings was used to determine causes of failure. All procedures were categorizes as Sharkey et al. described previously. The data was analyzed regarding the cause of failure and displaying the incidence and trends over the last 10 years. 1225 surgeries were done in the time period with a steady increase of procedures per year (34 procedures in 2000 to 196 in 2009). The most common cause of revision TKA was aseptic failure in 65% and septic failure in 31% of the reviewed cases. However, we could observe a steady proportional increase of the septic classified revisions over the time. Both categories could be subdivided to specific causes of failure including aseptic loosening (24%), anterior knee pain (20%), instability (6,4%), arthrofibrosis (4,9%), PE wear (3,6%), malpositioning/malrotation (2,7%) periprosthetic fracture (2,0%) and other (4,6%), or in early (12,9%), late (15,4%) or
Pneumatic tourniquets are often used during the surgical treatment of unstable traumatic ankle fractures. The aim of this study was to assess the risk of reoperation after open reduction and internal fixation of ankle fractures with and without the use of pneumatic tourniquets. This was a population-based cohort study using data from the Danish Fracture Database with a follow-up period of 24 months. Data were linked to the Danish National Patient Registry to ensure complete information regarding reoperations due to complications, which were divided into major and minor. The relative risk of reoperations for the tourniquet group compared with the non-tourniquet group was estimated using Cox proportional hazards modelling.Aims
Methods
The primary aim of this study was to determine if delayed clavicular fixation results in a greater risk of operative complications and revision surgery. A retrospective case series was undertaken of all displaced clavicular fractures that underwent plate fixation over a ten-year period (2007 to 2017). Patient demographics, time to surgery, complications, and mode of failure were collected. Logistic regression was used to identify independent risk factors contributing towards operative complications. Receiver operating characteristic (ROC) curve analysis was used to determine if a potential ‘safe window’ exists from injury to delayed surgery. Propensity score matching was used to construct a case control study for comparison of risk.Aims
Patients and Methods