The iliopsoas is considered a major deforming force causing hip flexion deformity in children with cerebral palsy. Although iliopsoas release at the
Purpose. Incidence of malrotation of femoral fractures after intramedullary nailing is as high as 28%. Prevention of malrotation is superior to late derotation osteotomy. The
Aims. This study aimed to investigate the incidence of ≥ 5 mm asymmetry in lower and whole leg lengths (LLs) in patients with unilateral osteoarthritis (OA) secondary to developmental dysplasia of the hip (DDH-OA) and primary hip osteoarthritis (PHOA), and the relationship between lower and whole LL asymmetries and femoral length asymmetry. Methods. In total, 116 patients who underwent unilateral total hip arthroplasty were included in this study. Of these, 93 had DDH-OA and 23 had PHOA. Patients with DDH-OA were categorized into three groups: Crowe grade I, II/III, and IV. Anatomical femoral length, femoral length greater trochanter (GT), femoral length
Aims. The aim of this study was to report the long-term follow-up of cemented short Exeter femoral components when used in primary total hip arthroplasty (THA). Methods. We included all primary 394 THAs with a cemented short Exeter femoral component (≤ 125 mm) used in our tertiary referral centre between October 1993 and December 2021. A total of 83 patients (21%) were male. The median age of the patients at the time of surgery was 42 years (interquartile range (IQR) 30 to 55). The main indication for THA was a childhood hip disease (202; 51%). The median follow-up was 6.7 years (IQR 3.1 to 11.0). Kaplan-Meier survival analyses were performed to determine the rates of survival with femoral revision for any indication, for septic loosening, for fracture of the femoral component and for aseptic loosening as endpoints. The indications for revision were evaluated. Fractures of the femoral component were described in detail. Results. The 20-year rate of survival was 85.4% (95% confidence interval (CI) 73.9 to 92.0) with revision for any indication, 96.2% (95% CI 90.5 to 98.5) with revision for septic loosening and 92.7% (95% CI 78.5 to 97.6) with revision for fracture of the femoral component. No femoral components were revised for aseptic loosening. There were 21 revisions of the femoral component; most (seven) as part of a two-stage management of infection. Fracture of the femoral component occurred in four THAs (1.0%) at 6.6, 11.6, 16.5, and 18.2 years of follow-up, respectively. Three of these were transverse fractures and occurred at the level of the
This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm3). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis.Aims
Methods
Securing the osteotomized greater trochanter (GT) during total hip arthroplasty (THA) for dislocated dysplastic hips (DDH) poses a significant challenge. This study evaluates the union rate and effectiveness of a 2-strand transverse wiring technique utilizing the
Aims. The aim of this study was to examine whether hips with unilateral osteoarthritis (OA) secondary to developmental dysplasia of the hip (DDH) have significant asymmetry in femoral length, and to determine potential related factors. Patients and Methods. We enrolled 90 patients (82 female, eight male) with DDH showing unilateral OA changes, and 43 healthy volunteers (26 female, 17 male) as controls. The mean age was 61.8 years (39 to 93) for the DDH groups, and 71.2 years (57 to 84) for the control group. Using a CT-based coordinate measurement system, we evaluated the following vertical distances: top of the greater trochanter to the knee centre (femoral length GT), most medial prominence of the
Objective. In total hip arthroplasty (THA), the femoral component influences leg length inequality and gait, and is associated with poor muscle strength and other unsatisfactory long-term results. We have therefore used intraoperative radiographs to acquire accurate measurements of femoral component size and position. At the last meeting of this society, we reported that accurate positioning was successfully achieved in 68 cases (87.2%) as a consequence of taking intraoperative radiographs. However, we have little understanding as regards to the accuracy of X-ray measurements. We accordingly undertook an examination of the accuracy of such measurements. The purpose of this study was to evaluate the difference between leg length discrepancy (LLD) measured using X-ray and computed tomography (CT). Materials and Methods. The study group comprised 48 primary THAs performed between October 2010 and April 2012. Using 2D template software (JMM Corporation), we measured LLD using pre-operative anteroposterior (AP) radiographs of the pelvis. On the basis of both teardrop lines, we measured LLD of the
One of the most important characteristic of the developmental dysplastic hip (DDH) is high anteversion in femoral neck. Neck-shaft angle is also understood to be higher (i.e. coxa-valga) in DDH femora. From this understanding many DDH intended stems were designed having larger neck shaft angle. According to the result of our prior study; reported in ISTA 2005 etc.; using computer 3-D virtual surgery of high fit-and-fill lateral flare stem into high anteversion patients, it was revealed that the geometry of proximal femur itself does not have big difference from normal femora but they are only rotated blow lessertrochanter. It is very important to know what anteversion is, and where anteversion is located, to design a better stem and to decide more proper surgical procedures for DDH cases with high anteversion. In the present study, the geometry of 57 femora was assessed in detail to reveal the geometry of anteversion and its location in the DDH femora. Fifty seven CAT scan data with many causes were analyzed. Thirty-two DDH, 3 Rheumatic Arthritis (RA), 2 metastatic bone tumors, 4 avascular necrosis (AVN), 1 knee arthritis, 12 injuries, and 3 normal candidates were included. Whole femoral geometries were obtained from CAT scan DICOM data and transferred to CAD geometry data format. All the following landmarks were measured its direction by the angle from posterior condylar line. The assessed landmarks were. anteversion,.
Purpose. Leg length discrepancy after total hip arthroplasty (THA) sometimes causes significant patient dissatisfaction. In consideration of the leg length after THA, leg length discrepancy is often measured using anteroposterior (AP) pelvic radiography. However, some cases have discrepancies in femoral and tibial lengths, and we believe that in some cases, true leg length differences should be taken into consideration in total leg length measurement. We report the lengths of the lower limb, femur, and tibia measured using the preoperative standing AP full-leg radiographs of the patients who underwent THA. Materials and methods. From August 2013 to February 2017, 282 patients underwent standing AP full-leg radiography before THA. Of the patients, 33 were male and 249 were female. The mean age of the patients was 65.7±9.4 years. We measured the distances between the center of the tibial plafond and
Objective: Establishment of the new method to evaluate fill of the hip stem. Background: The fill of the hip stem is one of the important parameters to estimate the quality of planning or positioning of the cementless stem. It has been defined as a stem-canal width ratio on the A-P plain of X-ray images so far. However, it is quite a problem to get the correct AP images on basis so that positional difference may affect the measurement. According to our data, the fill was measured significantly different in 15, 30, 45, 60 degrees erroneous direction. First, we tried to figure out the fill of the hip stem three-dimensionally rather 2-dimensionally. Next, our new method was compared to conventional method. Material and Methods: Leg CAT scans were performed on 32 hips of 20 patients (2 male, 18 female). Images of the canal of femora were reconstructed using CAD software. We made 2-types of canal model with or without
Introduction: Clinical experience has shown that addressing variations in bone morphology is important in the development of successful hip implant designs. Numerous studies of femoral bone morphology have been published utilizing various techniques. This study has developed a method which consistently measures large quantities of 3-dimensional digital femura geometry segmented from computed tomography (CT) scans and can accurately make anatomical measurements from these images. Methods: CT images of left femora on five hundred fifty six left femura (57% male, 43% female), consisting of 69% Caucasian, 16% Asian and 14% unknown were analyzed. The average age was 66 years, ranging from 40 to 93 years. Segmentation of the outer cortical, inner cortical, and marrow boundaries were consistently performed over all CT scans. The positions identified on the reference bone are transformed to the equivalent position on the clinical bone images, from which the dimensional data is extracted and stored. The mediolateral width (MLW), medial offset (MO) and lateral offset (LO) were measured in 10mm increments, ranging from 20mm above the
Purpose. Accolade TMZF® has the wedged taper shape and is fixed at the middle part. We testified the short term result of Accolade® and investigated the factor of subsidence. Materials and Methods. We treated 21 hips in 20 patients (6 males and 15 females) with Accolade stem. The mean age was 61.2 years old (40–79 years old). The mean follow-up period was 11.1 months (6–23 months), and those within 5 months after operation were excluded. We measured the width of the stem and the canal of femur at the level of the upper and the lower end of
I use monolithic, cylindrical, fully porous coated femoral components for many femoral revisions. Our institutional database holds information on 1000 femoral revisions using extensively porous-coated stems. To date, 27 stems have been re-revised (14 for loosening, 4 for infection, 7 for stem fracture, 2 at time of periprosthetic femoral fracture). Using femoral re-revision for any reason as an end point, the survivorship is 99 ± 0.8% (95% confidence interval) at 2 years, 97 ± 1.3% at 5 years, 95.6 ± 1.8% at 10 years, and 94.5 ± 2.2% at 15 years. Similar to Moreland and Paprosky, we have identified pre-revision bone stock as a factor affecting femoral fixation. Among the 777 femoral revisions graded for femoral bone loss, 59% of the femurs were graded as having no cortical damage before the revision, 29% had cortical damage extending no more than 10 cm below the
Aims. The diversity of femoral morphology renders femoral component sizing in total hip arthroplasty (THA) challenging. We aimed to determine whether femoral morphology and femoral component filling influence early clinical and radiological outcomes following THA using fully hydroxyapatite (HA)-coated femoral components. Methods. We retrospectively reviewed records of 183 primary uncemented THAs. Femoral morphology, including Dorr classification, canal bone ratio (CBR), canal flare index (CFI), and canal-calcar ratio (CCR), were calculated on preoperative radiographs. The canal fill ratio (CFR) was calculated at different levels relative to the
I prefer monolithic, cylindrical, fully porous coated femoral components for most femoral revisions. Our institutional database holds information on 1000 femoral revisions using extensively porous-coated stems. To date, 27 stems have been rerevised (14 for loosening, 4 for infection, 7 for stem fracture, 2 at time of periprosthetic femoral fracture). Using femoral rerevision for any reason as an end point, the survivorship is 99 ± 0.8% (95% confidence interval) at 2 years, 97 ± 1.3% at 5 years, 95.6 ± 1.8% at 10 years, and 94.5 ± 2.2% at 15 years. Similar to Moreland and Paprosky, we have identified prerevision bone stock as a factor affecting femoral fixation. Among the 777 femoral revisions graded for femoral bone loss, 59% of the femurs were graded as having no cortical damage before the revision, 29% had cortical damage extending no more than 10cm below the
Aims. A lack of supporting clinical studies have been published to determine the ideal length of intramedullary nail in fixation of trochanteric fractures of the hip. Nevertheless, there has been a trend to use shorter intramedullary nails for the internal fixation of trochanteric hip fractures. Our aim was to determine if the length of nail affected the outcome. Methods. We randomized 229 patients with a trochanteric hip fracture between two implants: a ‘standard’ nail of 220 mm and a shorter nail of 175 mm, which had decreased proximal angulation (4° vs 7°) and a reduced diameter at the level of the
Summary Statement. We used three-dimensional software to assess different anatomic variables in the femur. The canal of Femur twisted slightly below the
Introduction. In DDH cases often have high anteversion. They also often have high hip center. THA for those cases sometimes requires subtrochanteric derotational/shortening osteotomy. To achieve good results of the surgery, accurate preoperative planning based on biomechanics of the high anteversion cases, method for accurate application of the plan, and stable fixation are very important. At ISTA 2008, we have reported that the location of the anteversion exist several centimeters below the