Advertisement for orthosearch.org.uk
Results 1 - 20 of 52
Results per page:
Bone & Joint Research
Vol. 11, Issue 8 | Pages 575 - 584
17 Aug 2022
Stoddart JC Garner A Tuncer M Cobb JP van Arkel RJ

Aims. The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Methods. Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95. th. percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone. Results. Peak tensile strains occurred on the anterior portion of the medial sagittal cut in all simulations. Lateral translation of the medial implant in Bi-UKA had the largest increase in ROF of any of the implant positions (43%). Overstuffing the joint by 2 mm had a much larger effect, resulting in a six-fold increase in ROF. Bi-UKA had ~10% increased ROF compared to UKA-M for both the male and female models, although the smaller, less dense female model had a 1.4 times greater ROF compared to the male model. Removal of anterior bone akin to BCR-TKA doubled ROF compared to Bi-UKA. Conclusion. Tibial eminence avulsion fracture has a similar risk associated with Bi-UKA to UKA-M. The risk is higher for smaller and less dense tibiae. To minimize risk, it is most important to avoid overstuffing the joint, followed by correctly positioning the medial implant, taking care not to narrow the bone island anteriorly. Cite this article: Bone Joint Res 2022;11(8):575–584


Bone & Joint Open
Vol. 4, Issue 6 | Pages 432 - 441
5 Jun 2023
Kahlenberg CA Berube EE Xiang W Manzi JE Jahandar H Chalmers BP Cross MB Mayman DJ Wright TM Westrich GH Imhauser CW Sculco PK

Aims

Mid-level constraint designs for total knee arthroplasty (TKA) are intended to reduce coronal plane laxity. Our aims were to compare kinematics and ligament forces of the Zimmer Biomet Persona posterior-stabilized (PS) and mid-level designs in the coronal, sagittal, and axial planes under loads simulating clinical exams of the knee in a cadaver model.

Methods

We performed TKA on eight cadaveric knees and loaded them using a robotic manipulator. We tested both PS and mid-level designs under loads simulating clinical exams via applied varus and valgus moments, internal-external (IE) rotation moments, and anteroposterior forces at 0°, 30°, and 90° of flexion. We measured the resulting tibiofemoral angulations and translations. We also quantified the forces carried by the medial and lateral collateral ligaments (MCL/LCL) via serial sectioning of these structures and use of the principle of superposition.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 45 - 45
1 Jul 2022
Senevirathna S Yellu S Sweed T Geutjens G
Full Access

Abstract. Introduction. Derby technique for posterolateral corner (PLC) reconstruction uses a doubled gracilis autograft to reconstruct the popliteo-fibular ligament (PFL) and a split biceps tendon transfer to reconstruct the lateral collateral ligament (LCL). We report midterm outcomes of a case series who underwent PLC reconstruction. Methodology. A retrospective review of 27 patients who underwent PLC reconstruction from 2012 until 2018 was performed (6 females, 21 males, median age 26). Median time interval from injury to primary procedure was 10 months. Outcomes were recorded as per clinical assessment and outcome scores. Results. All patients had no varus laxity in full knee extension. Similarly, at 30° of knee flexion, 25 patients (92.5%) had no varus laxity and 2 patients (7.5%) had grade 1 laxity. No patients demonstrated abnormal external rotation at final follow up. Outcome scores were obtained from 17 patients who underwent primary ligament reconstruction at a mean follow up of 72 months postoperatively. The mean Lysholm score was 94 +/-5.5 (72–100) and mean subjective IKDC score was 78/87 (89.6%) (51–87). 90% of our patients had gained normal or nearly normal IKDC scores on returning to routine activities of daily living and sports following surgery compared to their pre-injury status. Conclusion. Our technique enables an anatomical LCL & PFL reconstruction in isolation or in combination with ACL/PCL reconstruction or to augment an acute repair without contralateral graft harvest or allograft. The functional knee scores demonstrated in this cohort are comparable and in fact superior to previously published knee scores after PLC reconstruction


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1324 - 1330
3 Oct 2020
Herregodts S Verhaeghe M Paridaens R Herregodts J Vermue H Arnout N De Baets P Victor J

Aims. Inadvertent soft tissue damage caused by the oscillating saw during total knee arthroplasty (TKA) occurs when the sawblade passes beyond the bony boundaries into the soft tissue. The primary objective of this study is to assess the risk of inadvertent soft tissue damage during jig-based TKA by evaluating the excursion of the oscillating saw past the bony boundaries. The second objective is the investigation of the relation between this excursion and the surgeon’s experience level. Methods. A conventional jig-based TKA procedure with medial parapatellar approach was performed on 12 cadaveric knees by three experienced surgeons and three residents. During the proximal tibial resection, the motion of the oscillating saw with respect to the tibia was recorded. The distance of the outer point of this cutting portion to the edge of the bone was defined as the excursion of the oscillating saw. The excursion of the sawblade was evaluated in six zones containing the following structures: medial collateral ligament (MCL), posteromedial corner (PMC), iliotibial band (ITB), lateral collateral ligament (LCL), popliteus tendon (PopT), and neurovascular bundle (NVB). Results. The mean 75. th. percentile value of the excursion of all cases was mean 2.8 mm (SD 2.9) for the MCL zone, mean 4.8 mm (SD 5.9) for the PMC zone, mean 3.4 mm (SD 2.0) for the ITB zone, mean 6.3 mm (SD 4.8) for the LCL zone, mean 4.9 mm (SD 5.7) for the PopT zone, and mean 6.1 mm (SD 3.9) for the NVB zone. Experienced surgeons had a significantly lower excursion than residents. Conclusion. This study showed that the oscillating saw significantly passes the edge of the bone during the tibial resection in TKA, even in experienced hands. While reported neurovascular complications in TKA are rare, direct injury to the capsule and stabilizing structures around the knee is a consequence of the use of a hand-held oscillating saw when making the tibial cut. Cite this article: Bone Joint J 2020;102-B(10):1324–1330


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 78 - 78
1 Aug 2020
Marwan Y Martineau PA Kulkarni S Addar A Algarni N Tamimi I Boily M
Full Access

The anterolateral ligament (ALL) is considered as an important stabilizer of the knee joint. This ligament prevents anterolateral subluxation of the proximal tibia on the femur when the knee is flexed and internally rotated. Injury of the ALL was not investigated in patients with knee dislocation. The aim of the current research is to study the prevalence and characteristics of ALL injury in dislocated knees. A retrospective review of charts and radiological images was done for patients who underwent multiligamentous knee reconstruction surgery for knee dislocation in our institution from May 2008 to December 2016. Magnetic resonance imaging (MRI) was used to describe the ALL injury. The association of ALL injury with other variables related to the injury and the patient's background features was examined. Forty-eight patients (49 knees) were included. The mean age of the patients was 32.3 ± 10.6 years. High energy trauma was the mechanism of dislocation in 28 (57.1%) knees. Thirty-one knees (63.3%) were classified as knee dislocation (KD) type IV. Forty-five (91.8%) knees had a complete ALL injury and three (6.1%) knees had incomplete ALL injury. Forty (81.6%) knees had a complete ALL injury at the proximal fibres of the ALL, while 23 (46.9%) knees had complete distal ALL injury. None of the 46 (93.9%) knees with lateral collateral ligament (LCL) injury had normal proximal ALL fibres (p = 0.012). Injury to the distal fibres of the ALL, as well as overall ALL injury, were not associated with any other variables (p >0.05). Moreover, all patients with associated tibial plateau fractures (9, 18.4%) had abnormality of the proximal fibres of the ALL (p = 0.033). High grade ALL injury is highly prevalent among dislocated knees. The outcomes of reconstructing the ALL in multiligamentous knee reconstruction surgery should be investigated in future studies


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 112 - 112
1 Jul 2020
Badre A Banayan S Axford D Johnson J King GJW
Full Access

Hinged elbow orthoses (HEO) are often used to allow protected motion of the unstable elbow. However, biomechanical studies have not shown HEO to improve the stability of a lateral collateral ligament (LCL) deficient elbow. This lack of effectiveness may be due to the straight hinge of current HEO designs which do not account for the native carrying angle of the elbow. The aim of this study was to determine the effectiveness of a custom-designed HEO with adjustable valgus angulation on stabilizing the LCL deficient elbow. Eight cadaveric upper extremities were mounted in an elbow motion simulator in the varus position. An LCL injured (LCLI) model was created by sectioning of the common extensor origin, and the LCL. The adjustable HEO was secured to the arm and its effect with 0°, 10°, and 20° (BR00, BR10, BR20) of valgus angulation was investigated. Varus-valgus angles and ulnohumeral rotations were recorded using an electromagnetic tracking system during simulated active elbow flexion with the forearm pronated and supinated. We examined 5 elbow states, intact, LCLI, BR00, BR10, BR20. There were significant differences in varus and ER angulation between different elbow states with the forearm both pronated and supinated (P=0 for all). The LCLI state with or without the brace resulted in significant increases in varus angulation and ER of the ulnohumeral articulation compared to the intact state (P 0.05). The difference between each of the brace angles and the LCLI state ranged from 1.1° to 2.4° for varus angulation and 0.5° to 1.6° for ER. Although there was a trend toward decreasing varus and external rotation angulation of the ulnohumeral articulation with the application of this adjustable HEO, none of the brace angles examined in this biomechanical investigation was able to fully restore the stability of the LCL deficient elbow. This lack of stabilizing effect may be due to the weight of the brace exerting unintentional varus and torsional forces on the unstable elbow. Previous investigations have shown that the varus arm position is highly unstable in the LCL deficient elbow. Our results demonstrate that application of an HEO with an adjustable carrying angle does not sufficiently stabilize the LCL deficient elbow in this highly unstable position and varus arm position should continue to be avoided in the rehabilitation programs of an LCL deficient elbow


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 68 - 68
1 Dec 2020
Taylan O Slane J Ghijselings I Delport HP Scheys L
Full Access

Poor soft tissue balance in total knee arthroplasty (TKA) is one of the most primary causes of dissatisfaction and reduced joint longevity, which are associated with postoperative instability and early implant failure. 1. Therefore, surgical techniques, including mechanical instruments and 3-D guided navigation systems, in TKA aim to achieve optimum soft tissue balancing in the knee to improve postoperative outcome. 2. Patella-in-Place balancing (PIPB) is a novel technique which aims to restore native collateral ligament behaviour by preserving the original state without any release. Moreover, reduction of the joint laxity compensates for the loss of the visco-elastic properties of the cartilage and meniscus. Following its clinical success, we aimed to evaluate the impact of the PIPB technique on collateral ligament strain and laxity behaviour, with the hypothesis that PIPB would restore strains in the collateral ligaments. 3. . Eight fresh-frozen cadaveric legs were obtained (KU Leuven, Belgium, H019 2015-11-04) and CT images were acquired while rigid marker frames were affixed into the femur, and tibia for testing. After carefully removing the soft tissues around the knee joint, while preserving the joint capsule, ligaments, and tendons, digital extensometers (MTS, Minnesota, USA) were attached along the length of the superficial medial collateral ligament (MCL) and lateral collateral ligament (LCL). A handheld digital dynamometer (Mark-10, Copiague, USA) was used to apply an abduction or adduction moment of 10 Nm at fixed knee flexion angles of 0°, 30°, 60° and 90°. A motion capture system (Vicon Motion Systems, UK) was used to record the trajectories of the rigid marker frames while synchronized strain data was collected for MCL/LCL. All motion protocols were applied following TKA was performed using PIPB with a cruciate retaining implant (Stryker Triathlon, MI, USA). Furthermore, tibiofemoral kinematics were calculated. 4. and combined with the strain data. Postoperative tibial varus/valgus stresses and collateral ligament strains were compared to the native condition using the Wilcoxon Signed-Rank Test (p<0.05). Postoperative tibial valgus laxity was lower than the native condition for all flexion angles. Moreover, tibial valgus of TKA was significantly different than the native condition, except for 0° (p=0.32). Although, tibial varus laxity of TKA was lower than the native at all angles, significant difference was only found at 0° (p=0.03) and 90° (p=0.02). No significant differences were observed in postoperative collateral ligament strains, as compared to the native condition, for all flexion angles, except for MCL strain at 30° (p=0.02) and 60° (p=0.01). Results from this experimental study supported our hypotheses, barring MCL strain in mid-flexion, which might be associated with the implant design. Restored collateral ligament strains with reduced joint laxity, demonstrated by the PIPB technique in TKA in vitro, could potentially restore natural joint kinematics, thereby improving patient outcomes. In conclusion, to further prove the success of PIPB, further biomechanical studies are required to evaluate the success rate of PIPB technique in different implant designs


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 17 - 17
1 Jul 2020
Badre A Axford D Banayan S Johnson J King GJ
Full Access

The role of anconeus in elbow stability has been a long-standing debate. Anatomical and electromyographic studies have suggested a potential role as a stabilizer. However, to our knowledge, no clinical or biomechanical studies have investigated its role in improving the stability of a lateral collateral ligament (LCL) deficient elbow. Seven cadaveric upper extremities were mounted in an elbow motion simulator in the varus position. An LCL injured model was created by sectioning of the common extensor origin, and the LCL. The anconeus tendon and its aponeurosis were sutured in a Krackow fashion and tensioned to 10N and 20N through a transosseous tunnel at its origin. Varus-valgus angles and ulnohumeral rotations were recorded using an electromagnetic tracking system during simulated active elbow flexion with the forearm pronated and supinated. During active motion, the injured model resulted in a significant increase in varus angulation (5.3°±2.9°, P=.0001 pronation, 3.5°±3.4°, P=.001 supination) and external rotation (ER) (8.6°±5.8°, P=.001 pronation, 7.1°±6.1°, P=.003 supination) of the ulnohumeral articulation compared to the control state (varus angle −2.8°±3.4° pronation, −3.3°±3.2° supination, ER angle 2.1°±5.6° pronation, 1.6°±5.8° supination). Tensioning of the anconeus significantly decreased the varus angulation (−1.2°±4.5°, P=.006 for 10N in pronation, −3.9°±4°, P=.0001 for 20N in pronation, −4.3°±4°, P=.0001 for 10N in supination, −5.3°±4.2°, P=.0001 for 20N in supination) and ER angle (2.6°±4.5°, P=.008 for 10N in pronation, 0.3°±5°, P=.0001 for 20N in pronation, 0.1°±5.3°, P=.0001 for 10N in supination, −0.8°±5.3°, P=.0001 for 20N in supination) of the injured elbow. Comparing anconeus tensioning to the control state, there was no significant difference in varus-valgus angulation except with anconeus tensioning to 20N with the forearm in supination which resulted in less varus angulation (P=1 for 10N in pronation, P=.267 for 20N in pronation, P=.604 for 10N in supination, P=.030 for 20N in supination). Although there were statistically significant differences in ulnohumeral rotation between anconeus tensioning and the control state (except with anconeus tensioning to 10N with the forearm in pronation which was not significantly different), anconeus tensioning resulted in decreased external rotation angle compared to the control state (P=1 for 10N in pronation, P=.020 for 20N in pronation, P=.033 for 10N in supination, P=.001 for 20N in supination). In the highly unstable varus elbow orientation, anconeus tensioning restores the in vitro stability of an LCL deficient elbow during simulated active motion with the forearm in both pronation and supination. Interestingly, there was a significant difference in varus-valgus angulation between 20N anconeus tensioning with the forearm supinated and the control state, with less varus angulation for the anconeus tensioning which suggests that loads less than 20N is sufficient to restore varus stability during active motion with the forearm supinated. Similarly, the significant difference observed in ulnohumeral rotation between anconeus tensioning and the control state suggests that lesser degrees of anconeus tensioning would be sufficient to restore the posterolateral instability of an LCL deficient elbow. These results may have several clinical implications such as a potential role for anconeus strengthening in managing symptomatic lateral elbow instability


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 94 - 94
1 Jul 2020
Badre A Axford D Banayan S Johnson J King GJ
Full Access

Previous biomechanical studies of lateral collateral ligament (LCL) injuries and their surgical repair, reconstruction and rehabilitation have primarily relied on gravity effects with the arm in the varus position. The application of torsional moments to the forearm manually in the laboratory is not reproducible, hence studies to date likely do not represent forces encountered clinically. The aim of this investigation was to develop a new biomechanical testing model to quantify posterolateral stability of the elbow using an in vitro elbow motion simulator. Six cadaveric upper extremities were mounted in an elbow motion simulator in the varus position. A threaded screw was then inserted on the dorsal aspect of the proximal ulna and a weight hanger was used to suspend 400g, 600g, and 800g of weight from the screw head to allow torsional moments to be applied to the ulna. An LCL injured (LCLI) model was created by sectioning of the common extensor origin, and the LCL. Ulnohumeral rotation was recorded using an electromagnetic tracking system during simulated active and passive elbow flexion with the forearm pronated and supinated. A repeated measures analysis of variance was performed to compare elbow states (intact, LCLI, and LCLI with 400g, 600g, and 800g of weight). During active motion, there was a significant difference between different elbow states (P=.001 pronation, P=.0001 supination). Post hoc analysis showed that the addition of weights did not significantly increase the external rotation (ER) of the ulnohumeral articulation (10°±7°, P=.268 400g, 10.5°±7.1°, P=.156 600g, 11°±7.2°, P=.111 800g) compared to the LCLI state (8.4°±6.4°) with the forearm pronated. However, with the forearm supinated, the addition of 800g of weight significantly increased the ER (9.2°±5.9°, P=.038) compared to the LCLI state (5.9°±5.5°) and the addition of 400g and 600g of weights approached significance (8.2°±5.7°, P=.083 400g, 8.7°±5.9°, P=.054 600g). During passive motion, there was a significant difference between different elbow states (P=.0001 pronation, P=.0001 supination). Post hoc analysis showed that the addition of 600g and 800g but not 400g resulted in a significant increase in ER of the ulnohumeral articulation (9.3°±7.8°, P=.103 400g, 11.2°±6.2°, P=.004 600g, 12.7°±6.8°, P=.006 800g) compared to the LCLI state (3.7°±5.4°) with the forearm pronated. With the forearm supinated, the addition of 400g, 600g, and 800g significantly increased the ER (11.7°±6.7°, P=.031 400g, 13.5°±6.8°, P=.019 600g, 14.9°±6.9°, P=.024 800g) compared to the LCLI state (4.3°±6.6°). This investigation confirms a novel biomechanical testing model for studying PLRI. Moreover, it demonstrates that the application of even small amounts of torsional moment on the forearm with the arm in the varus position exacerbates the rotational instability seen with the LCL deficient elbow. The effect of torsional loading was significantly worse with the forearm supinated and during passive elbow motion. This new model allows for a more provocative testing of elbow stability after LCL repair or reconstruction. Furthermore, this model will allow for smaller sample sizes to be used while still demonstrating clinically significant differences. Future biomechanical studies evaluating LCL injuries and their repair and rehabilitation should consider using this testing protocol


Bone & Joint Research
Vol. 5, Issue 11 | Pages 552 - 559
1 Nov 2016
Kang K Koh Y Son J Kwon O Baek C Jung SH Park KK

Objectives. Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. Materials and Methods. Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions. Results. Contact stress on the medial side of the PE insert increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. There was an opposite trend in the lateral side of the PE insert case. Contact stress on the patellar button increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. In particular, contact stress on the patellar button increased by 98% with internal malrotation of 10° in the squat loading condition. The force on the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) increased with internal and external femoral malrotations, respectively. Conclusions. These findings provide support for orthopaedic surgeons to determine a more accurate femoral component alignment in order to reduce post-operative PE problems. Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, C. Baek, S. H. Jung, K. K. Park. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation. Bone Joint Res 2016;5:552–559. DOI: 10.1302/2046-3758.511.BJR-2016-0107.R1


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIII | Pages 18 - 18
1 Apr 2012
Rao M Arnaout F Williams D
Full Access

Knee dislocation is a rare injury in high energy trauma, but it is even rarer in low energy injuries. We present, to our knowledge, the only case in the world literature of knee dislocation following a cricketing injury. The patient was a 46 year old recreational fast bowler who, whilst bowling, slipped on the pitch on the follow through. He sustained an anteromedial knee dislocation which was reduced under intravenous sedation. He also sustained a neuropraxia of the common peroneal nerve with grade 2 weakness of ankle and toe dorsiflexion. Magnetic Resonance Imaging (MRI) confirmed a complete rupture of anterior cruciate ligament (ACL), lateral collateral ligament (LCL) and postero-lateral corner (PLC). Patient underwent surgical reconstruction and repair of his PLC along with repair of LCL with combination of anchor sutures and metal staple within 72 hours of the injury. He was treated in a cast brace. The ACL insufficiency was treated conservatively. Patient made an uneventful recovery and follow up at 3 months revealed a full range of knee movements with asymptomatic ACL laxity


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 20 - 20
1 Feb 2017
Athwal K El Daou H Lord B Davies A Manning W Rodriguez-Y-Baena F Deehan D Amis A
Full Access

Introduction. There is little information available to surgeons regarding how the lateral soft-tissue structures prevent instability in knees implanted with total knee arthroplasty (TKA). The aim of this study was to quantify the lateral soft-tissue contributions to stability following cruciate retaining (CR) TKA. Methods. Nine cadaveric knees with CR TKA implants (PFC Sigma; DePuy Synthes Joint Reconstruction) were tested in a robotic system (Fig. 1) at full extension, 30°, 60°, and 90° flexion angles. ±90 N anterior-posterior force, ±8 Nm varus-valgus and ±5 Nm internal-external torque were applied at each flexion angle. The anterolateral structures (ALS, including the iliotibial band, anterolateral ligament and anterolateral capsule), the lateral collateral ligament (LCL), the popliteus tendon complex (Pop T) and the posterior cruciate ligament (PCL) were then sequentially transected. After each transection the kinematics obtained from the original loads were replayed, and the decrease in force / moment equated to the relative contributions of each soft-tissue to stabilising the applied loads. Results. In the CR TKA knee, the LCL was found to be the primary restraint to varus laxity (Fig. 2, an average 56% across all flexion angles), and was significant in internal-external rotational stability (28% and 26% respectively) and anterior drawer (16%). The ALS restrained 25% of internal rotation (Fig. 3), whilst the PCL was significant in posterior drawer only at 60° and 90° flexion. The Pop T was not found to be significant in any tests. Conclusion. This study has for the first time delineated the relative contributions of lateral structures to stability in the implanted knee. It was confirmed that the LCL is the major lateral structure in CR TKA stability throughout the arc of flexion. In the event of LCL deficiency, stability of the knee may only be restored by either changing to a more constrained implant or performing a reconstruction of the ligament. Furthermore, care should be taken when releasing the LCL to correct a valgus deformity as it may result in a combined rotational laxity pattern that cannot be overcome by the other passive lateral structures or the PCL. For figures, please contact authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 109 - 109
1 Jan 2017
Beukes G Patnaik S Sivarasu S
Full Access

The function of the knee joint is to allow for locomotion and is comprised of various bodily structures including the four major ligaments; medial collateral ligament (MCL), lateral collateral ligament (LCL), anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL). The primary function of the ligaments are to provide stability to the joint. The knee is prone to injury as a result of osteoarthritis as well as ligamentous and meniscal lesions. Furthermore, compromised joint integrity due to ligamentous injury may be a result of direct and indirect trauma, illness, occupational hazard as well as lifestyle. A device capable of non-invasively determining the condition of the ligaments in the knee joint would be a useful tool to assist the clinician in making a more informed diagnosis and prognosis of the injury. Furthermore, the device would potentially reduce the probability of a misdiagnosis, timely diagnosis and avoidable surgeries. The existing Laxmeter prototype (UK IPN: GB2520046) is a Stress Radiography Device currently limited to measuring the laxity of the MCL and LCL at multiple fixed degrees of knee flexion. Laxity refers to the measure of a ligament's elasticity and stiffness i.e. the condition of the ligament, by applying a known load (200N) to various aspects of the proximal tibial and thereby inducing tibial translation. The extent of translation would indicate the condition of the ligament. The Laxmeter does not feature a load applying component as of yet, however, it allows for the patient to be in the most comfortable and ideal position during radiographic laxity measurement testing. The entire structure is radiolucent and attempts to address the limitations of existing laxity measurement devices, which includes: excessive radiation exposure to the radiographic assistant, little consideration for patient ergonomics and restrictions to cruciate or collateral ligament laxity measurements. The study focusses on further developing and modifying the Laxmeter to allow for: the laxity measurement of all four major ligaments of the knee joint, foldability for improved storage and increased structural integrity. Additionally, a load applicator has been designed as an add-on to the system thereby making the Laxmeter a complete Stress Radiography Device. Various materials including Nylon, Polycarbonate, Ultra High Molecular Weight Polyethylene (UHMWPE) – PE 1000, and Acetal/ POM were tested, using the Low Dose X-ray (Lodox) scanner, to determine their radiolucency. All materials were found to be radiolucent enough for the manufacture of the Laxmeter structure as well as the load applicator in order to identify and measure the translation of the tibia with respect to the stationary femur. The Laxmeter allows for the measurement of the laxity of the MCL and LCL at multiple fixed degrees of flexion by providing the ideal patient position for testing. The next iteration of the device will present an affordable and complete Stress Radiography Device capable of measuring the laxity of all four major ligaments of the knee joint at multiple fixed degrees of flexion. Future work would include aesthetic considerations as well as an investigation into carbon-fibre-reinforced plastics


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 15 - 15
1 Nov 2016
Thornton G Lemmex D Ono Y Hart D Lo I
Full Access

Lubricin is a proteoglycan that is a boundary lubricant in synovial joints and both a surface and collagen inter-fascicular lubricant in ligaments. The purpose of this study was to characterise the mRNA levels for lubricin in the anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL), and lateral collateral ligament (LCL) in aging and surgically-induced menopausal rabbits. We hypothesised that lubricin mRNA levels would be increased in ligaments from aging and menopausal rabbits compared with ligaments from normal rabbits. All four knee ligaments (ACL, PCL, MCL, LCL) were isolated from normal (1-year-old rabbits, n=8), aging (3-year-old rabbits, n=6), and menopausal (1-year-old rabbits fourteen weeks after surgical ovariohysterectomy, n=8) female New Zealand White rabbits. RT-qPCR was used to evaluate the mRNA levels for lubricin normalised to the housekeeping gene 18S. After removing outliers, data for normal, aging, and menopausal rabbits for each knee ligament (ACL, PCL, MCL, LCL) were compared using ANOVA with linear contrasts or Kruskal-Wallis test with Conover post-hoc analysis. For ACLs, the mRNA levels for lubricin were increased in menopausal and aging rabbits compared with normal rabbits (p<0.056). For PCLs, trends for increased lubricin mRNA levels were found when comparing menopausal and aging rabbits with normal rabbits (p<0.092). For MCLs, the mRNA levels for lubricin were increased in menopausal and aging rabbits compared with normal rabbits (p<0.050). For LCLs, no differences in lubricin mRNA levels were detected comparing the three groups. For all four knee ligaments (ACL, PCL, MCL, LCL), no differences in lubricin mRNA levels were detected comparing the ligaments from menopausal rabbits with those from aging rabbits. Lubricin plays a role in collagen fascicle lubrication in ligaments (1,2). Increased lubricin gene expression was associated with mechanical changes (including decreased modulus and increased failure strain) in the aging rabbit MCL (3). Detection of similar molecular changes in the ACL, and possibly the PCL, may indicate that their mechanical properties may also change as a result of increased lubricin gene expression, thereby potentially pre-disposing these ligaments to damage accumulation. Compared to aging ligaments, aging tendons exhibited decreased lubricin gene and protein expression, and increased stiffness (4). Although opposite changes than aging ligaments, these findings support the relationship between lubricin and modulus/stiffness. The similarities between ligaments in the aging and menopausal groups may suggest that surgically-induced menopause results in a form of accelerated aging in the rabbit ACL, MCL and possibly PCL


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 420 - 421
1 Sep 2009
Bhatnagar G Karadaglis D Varma R Groom G Shetty A
Full Access

Aim: Accurate soft tissue balance in total knee arthroplasty (TKA) is not only technically challenging but also difficult to teach to trainees; we believe that computer navigation provides a very useful tool for objective and reproducible soft tissue balance. Methods: We studied 52 patients (31 females and 21 males) with knee osteoarthritis and recorded the change of the Medial (MCL) and Lateral Collateral Ligament (LCL) length at full extension and at 90o flexion. Pre- and post-operative results were compared. The assessment was performed by consultant orthopaedic surgeons using trackers and navigation knee replacement software. Data was analysed using the student t-test. Results: The navigation software programme was used to measure the change of the collateral ligament length. Ligament laxity is represented by a negative number and a positive number is used to represent stretching and apparent elongation of the ligament. The medial collateral (MCL) length at full extension ranged from −9mm to 11mm and post-operatively was reduced to −16mm and 8mm, (p=0.042). At 90o flexion the length ranged from −3mm to 9mm and postoperatively was reduced to −8mm and 10mm (p=0.025). The lateral collateral (LCL) length at full extension changed from −10mm to 9mm pre-operatively to −13mm and 6mm post-operatively (p=0.011). At 90o flexion the range from −8mm and 9mm pre-operatively changed to − 5mm and 11mm post-operatively (p=0.005). All the above changes correspond to improvement in the post-operative axial alignment. Conclusion: Our results demonstrate that computer navigation provides a useful adjunct to the accurate and reproducible soft tissue balance in knee arthroplasty which can be used to evaluate results and for training purposes


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 46 - 46
1 Dec 2013
Delport H Labey L De Corte R Innocenti B Sloten JV Bellemans J
Full Access

Passive knee stability is provided by the soft tissue envelope which resists abnormal motion. There is a consensus amongst orthopedic surgeons that a good outcome in TKA requires equal tension in the medial and the lateral compartment of the knee joint, as well as equal tension in the flexion and extension gap. The purpose of this study was to quantify the ligament laxity in the normal non-arthritic knee before and after standard posterior-stabilized total knee arthroplasty (PS-TKA). We hypothesized that the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) will show minimal changes in length when measured directly by extensometers in the native human knee during varus/valgus laxity testing. We also hypothesized that due to differences in material properties and surface geometry, native laxity is difficult to be completely reconstructed using contemporary types of PS-TKA. Methods:. A total of 6 specimens were used to perform this in vitro cadaver test using extensometers to provide numerical values for laxity and varus-valgus tilting in the frontal plane. See Fig. 1 The test set-up. Findings:. This study enabled a very precise measurement of varus and valgus laxity as compared with the clinical assessment which is a subjective measure. The strains in both ligaments in the replaced knee were different from those in the native knee. Both ligaments were stretched in extension, in flexion the MCL tends to relax and the LCL remains tight. Fig. 2 Initial and maximal strain values in the MCL during valgus and varus laxity testing in different flexion angles. a: intact knee, b: replaced knee. and Fig. 3 Initial and maximal strain values in the LCL during valgus and varus laxity testing indifferent flexion angles. a: intact knee, b: replaced knee. Interpretation:. As material properties and surface geometry of the replaced knee add stiffness to the joint, we recommend when using a this type of PS-TKA to avoid overstuffing the joint in order to obtain varus/valgus laxity close to the native joint


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 636 - 642
1 Jul 1999
Shahane SA Ibbotson C Strachan R Bickerstaff D

We designed an experimental study to prove the existence of the popliteofibular ligament (PFL) and to define its role in providing static stability of the knee. We also examined the contribution of the lateral collateral ligament (LCL). We found this ligament to be present in all eight human cadaver knees examined. These specimens were mounted on a specially designed rig and subjected to posterior, varus and external rotational forces. We used the technique of selective sectioning of ligaments and measured the displacement with a constant force applied, before and after its division. We recorded the displacement in primary posterior translation, coupled external rotation, primary varus angulation and primary external rotation. Statistical analysis using the standard error of the mean by plotting 95% confidence intervals, was used to evaluate the results. The PFL had a significant role in preventing excessive posterior translation and varus angulation, and in restricting excessive primary and coupled external rotation. Isolated section of the belly of popliteus did not cause significant posterolateral instability of the knee. The LCL was also seen to act as a primary restraint against varus angulation and secondary restraint against external rotation and posterior displacement. Our findings showed that in knees with isolated disruption of the PFL stability was restored when it was reconstructed. However in knees in which the LCL was also disrupted, isolated reconstruction of the PFL did not restore stability


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 243 - 243
1 May 2009
Fraser GS Pichora JE Ferreira LM Brownhill JR Johnson JA King GJW
Full Access

This in-vitro study evaluated the influence of ligament tensioning and the effectiveness of lateral collateral ligament (LCL) repair using transosseous sutures on the initial kinematics and stability of the elbow. Six fresh upper-extremities were mounted in a motion simulator with tracking system, which enabled both passive and simulated active elbow flexion. The intact elbow was tested then the LCL was sectioned from its humeral origin and repaired with a transosseous suture technique. Locking sutures were placed in the LCL and passed through a humeral bone tunnel entering at the centre of curvature of the capitellum with exit holes in the lateral epicondyle. An actuator pulled on the sutures to achieve 20, 40 and 60 N of LCL repair tension and the sutures were then secured. The dependent variable of this study was the motion pathways of the ulna relative to the humerus. The data were analyzed using a two-way, repeated-measures ANOVA with relevant post-hoc paired t-tests. With the arm oriented in the horizontal position under varus gravity loading, the repairs tracked in greater valgus than the intact LCL regardless of the repair tension. The larger the initial repair tension, the more the elbows tracked in valgus. Initial tension of 60 N was statistically different than the intact LCL with the forearm in pronation (p=0.04). Both the 40 and 60 N initial tensions were statistically different than the intact LCL with the forearm in supination (p< 0.01). Repair of the LCL using transosseous sutures effectively restores the varus stability of the elbow. The initial tension of LCL repairs affects the kinematics of the elbow, with a tendency to over-tighten the ligament and pull the elbow into valgus. These data suggest that acute repair of the LCL should be performed using a transosseous suture technique, and that a tension of 20N or perhaps less is sufficient to restore stability


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 20 - 20
1 Apr 2013
Sonanis SV Kumar S Deshmukh N Wray C Beard DJ
Full Access

Introduction. A prospective study was done using Kirschner (K) wires to internally fix capitellum fractures and its results were analysed. Materials/Methods. Since 1989, unstable displaced 17 capitellum fractures were anatomically reduced and internally fixed by inserting K wires in coronal plane from the capitellum into trochlea. The lateral end of wires were bent in form of a staple behind the fracture plane and anchored into the lateral humeral condyle with pre-drilled holes. Additional screws were used in 2 cases to stabilise the lateral pillar comminution. The capitellum was exposed with a limited modified lateral elbow approach between anconeus and extensor carpi ulnaris. The capsule was reflected anteriorly to expose the capitellum and trochlea. The deeper dissection was limited anterior to lateral collateral ligament (LCL) keeping it intact. The capitellum fragment was reposition under the radial head and anatomically reduced by full flexion of elbow and then internally fixed. Total 17 patients (7 males and 10 females) with average ages 34.8 years(14 to 75) had fractures, Type I: (Hans Steinthal #) 12, Type II: (Kocher Lorez #) 1, and Type III: (Broberg and Morrey #) 4. Post-operatively the patients were not given any immobilisation and were mobilised immediately. Results. Patients were assessed clinically and radiologically. Average followup was 31.7 (18–35) months. Capitellum fractures healed in all the patients. Mayo elbow score was excellent in 12, good in 4, and fair in 1 patient. Average elbow ROM was 5 to 132 degrees, pronation 84.5 (79–90) degrees and supination 88 (85–91) degrees. Complications seen were wire pain in 4 patients, loosening of wires in 2 which required early removal. We did not see any infection, non-union or avascular necrosis in the time scale we studied. Conclusions. We found a simple manoeuvre of hyper-flexion of elbow reduced the capitellum anatomically, and K wires stapling technique to be very easy and stable. A limited exposure of capitellum helped to restore immediate stable elbow with good function


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 278 - 279
1 Sep 2005
Briard J
Full Access

Soft tissue balancing in fixed genu valgum can be challenging and may lead to instability in flexion. Current techniques involve release of the tight secondary structures initially, with the fascia lata and the lateral capsule usually addressed first, and then the posterior capsule if necessary. If ligament testing does not permit neutral alignment in extension, release of the lateral collateral ligament becomes necessary. The most common way of achieving neutral alignment is by lengthening the lateral structures through elevation of the proximal insertion of the lateral collateral ligament (LCL). This technique has two drawbacks: the lengthening affects both extension and flexion gaps and may give rise to excessive external rotation of the femoral implant, with too much offset of the rotational centre. Particularly when non-constrained prostheses are used, the resulting lateral instability in flexion can be a problem. An alternative is to perform a release at the level of the distal insertion of the LCL, as advocated by Keblish and Buechel. However, this still induces undue external rotation of the femoral implant. We think that if the situation in flexion before any release is satisfactory in terms of the patella, it should not be changed. This means that in order to maintain optimal patellofemoral function, the flexion gap should be addressed before any release. The task is then to achieve a good extension gap with a well-aligned knee. In fixed valgus deformities, this means distal translocation of the femoral insertion of the LCL by distal sliding lateral condylar osteotomy. This procedure aims to preserve the flexion condition and to allow distal slide of the lateral condylar osteotomised fragment. In doing the osteotomy, it is important to make the lateral fragment sufficiently large to allow relocation of the osteotomised fragment inside the prosthesis. This provides the immediate stability necessary for good healing. We have been using two simple cortical screws to ensure stability of the fragment. This paper reports our experience in 100 cases