Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 15 - 15
1 Sep 2012
George A Hassaballa M Artz N Alhammali T Robinson J Porteus A Murray J
Full Access

Introduction. The legion knee revision system was designed as a follow and improvement to the Genesis II knee system- allowing for a surgeon directed femoral rotation as opposed to the in-built femoral rotation in the previous system. This is a prospective review of consecutive patients who underwent knee revision surgery using the legion knee system. Methods. Clinical and functional assessments were carried out preoperatively, one year and 2 years post op. Radiographic evaluation was done at 1 and 2years follow up. Standard knee scoring systems (American Knee Scores-AKS, and Oxford score were used for the clinical and functional evaluation of these patients. The WOMAC score was also used to assess for pain, stiffness and social function in these patients. The radiographic assessment included review of standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction. A difference of 5 mm (pre = op/post-op) was deemed satisfactory. Results. Seventy-five consecutive patients underwent revision knee system- 38 male: 34 females with a mean age of 71.2 (50–87 yrs.). Mean BMI-26.03, (Range 11–50). We had a 2-year follow up for 32 patients Surgery was carried out at a single centre and performed by members of the Bristol knee group. Indications for surgery in these patients- were aseptic loosening (38), instability (15), pain and stiffness (7), polyarthropathy (2), ligament laxity (3), peri-prosthetic fractures (3), and impingement (4). The mean American Knee scores, and WOMAC scores at, 1 year and 2 years follow up showed significant improvements in pain and function. It was also noted that the mean oxford knee score improved from 14/48 pre-operatively to 34/48 at 2yrs. Radiographic assessment showed a mean AP coronal femoral angle of 95.3 degrees (range 89.6–99.9 degrees), coronal tibial angle of 90.1 degrees (Range 88–92 degrees). The mean sagittal femoral and tibial angles were 88.4 and 90.4 degrees respectively. Mean Kappa value for the inter observer reliability for the radiographic assessment was 0.50 showing agreement, with standard error measurement of 1.2. The joint line was reproduced in all cases. Discussion. The short-term results with the Legion Knee revision system showed significant improvement in functional and pain scores in these patients irrespective of their indications for revision surgery. Overall the legion system has showed good outcome scores that match or beat published series on revisions. It also showed a good ability to restore joint line. Ongoing work needed to refine indications and realistic outcomes for different diagnoses


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 165 - 165
1 Sep 2012
Gebauer M Breer S Hahn M Kendoff D Amling M Gehrke T
Full Access

Introduction. Modular tantalum augments have been introduced to manage severe bone defects in hip and knee revision surgery. The porous surfaces of tantalum augments are intended to enhance osseointegration and a number of studies have documented their excellent biocompatibility. However, the characteristics of tantalum augment osseointegration on human ex vivo specimens from re-revision procedures have not been reported so far. Methods. Out of a total number of 324 hip and knee revisions with a tantalum augment performed in our institution between 2007 and 2010 four patients had to be re-revised at a mean followup time of 15 months. The causes for re-revision were a periprosthetic acetabular fracture in one, a loosening of a tibial component in one and periprosthetic hip infections in two cases. To characterize osseointegration of the tantalum augments, they were removed during revision surgery and subjected to undecalcified processing. All specimens were analysed by contact radiography, histology (toluidine blue, von Kossa) and quantitative histomorphometry. Results. In all specimens trabecular ingrowth was apparent along the former bone-augment-interface. The depth of bone ingrowth into the porous microarchitecture of the augments reached up to 2000 μm. Thin-section analysis revealed scattered and partially mineralized bone forming units within the interior of the augments. Conclusions. To the best of our knowledge this is the first histomorphometric analysis on the osseointegration of tantalum augments in human ex vivo specimens. In the presented series porous tantalum showed excellent osteoconductive characteristics on the histological level. These early ex vivo histological findings are promising, but structural analysis of later re-revision cases is needed


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 53 - 53
1 Sep 2012
Esteve C Esteve C Garcia-Forcada I Gina J
Full Access

Introduction. Surgical site infections (SSI) are related to a surgical procedure and affect the surgical wound or deeper tissues. With continuing emphasis on clinical governance and quality control, there is increasing demand from both patients and government for methods of assessing surgical results. Rates of morbidity and mortality may play important roles in these assessments. When crude comparisons between hospitals in the incidence of SSI are made, these should at least be stratified by the type of procedure. The aim of this study is to fix SSI incidence in relation to surgical procedure. Methods. This report contains data of 19.948 procedures collected from 1996 to 2008 at a Specialist Orthopaedic Hospital and analyzed by a specific software designed for the study of infection in orthopaedic and trauma surgery. The SSI surveillance is focused on categories of surgical procedure (Hip Arthroplasty, Knee Arthroplasty, Spine Surgery and Hip Fracture Surgery) with each category containing a defined set of similar procedures. A basic of demographic data and details about operation itself are collected for each procedure. Patients are followed up throughout their hospital stay and after hospital discharge. We present the incidence of SSI by risk group and surgical procedure. SSI are categorized in type, moment of diagnosis and micro-organisms reported. Analysis of the data was performed (SPSSv15.0 ®). Statistical methods used to determine significance were the independent samples t test, Pearson X2 test, Odds ratio and Spearman correlation coefficient, with a significance level of p<0,05. Results. Rates of SSI are highest in hip hemiarthroplasty after fracture and in hip and knee revision procedures. Rates of SSI increase with the number of risk factors present in the patient, especially after fracture procedures. The most common infecting micro-organism was coagulase-negative staphylococcus, followed by Staphylococcus aureus, enterococci and streptococci. 38% of the infections arise after one year of surveillance. Conclusions. Our results confirm difference in rates of SSI depending of surgical procedure in orthopaedic and trauma surgery. We believe that our decision to monitor infection with a long term follow up it's the better way to avoid under-reporting of infection. Our study has also demonstrated the extent to which the emerging problem of infection due to MRSA has affected orthopaedic surgery. The risk of acquiring SSI caused by MRSA was particularly high in patients after hip fracture surgery. Rates of SSI increase with the number of risk factors present in the patient, especially after fracture procedures. Globally, the most common infecting micro-organism was coagulase-negative staphylococcus, followed by Staphylococcus aureus, enterococci and streptococci. 38% of the infections arise after one year of surveillance


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 394 - 394
1 Sep 2012
Stoeckl B
Full Access

Introduction. Total femur implantation is a rare and challenging procedure in final revision surgery of hip and knee arthroplasties. Reports of this operation technique are even rare in literature. In this study we retrospectively analyse our patients with total femur implants. Material and Methods. Between October 2002 and February 2009 we implanted 27 total femurs in hip and knee revision surgery cases. We used the modular prosthesis system–Megasystem C® by Waldemar Link–in all cases. Our 22 female and 5 male patients had a mean age of 76 years (range 45–88). Indications for the procedure were loosening of megaprosthesis of the hip in 12 cases; 2 with massive distal migration, 1 with penetration into the knee joint and 1 after two step revision procedure. In 13 cases a periprosthetic indicated a total femur implanatation due to massive bone loss; 1 breakage of a long femoral stem, 5 fracture of osteosynthesis materials, 3 after prosthesis revisions and 1 pseudoarhrosis of femur and tibia after knee arthroplasty. We analysed perioperative complications, clinical status and result and further revision within follow up time. Results. We were able to examine 16 patients at follow up time. Eight patients were lost to follow up and 2 have been died; 1 after fulminant pulmonal embolia after operation and 1 four years postoperatively. One total femur had to be exchanged due to infection after 1 year. Perioperative complications occurred as follows: 1 massive blood transfusion, 1 peroneal palsy, 1 ulcus ventriculis bleeding, 1 thrombosis of vena suclavia and vena jugularis, 1 sigmaresection due to diverticulosis, 1 luxations of the hip, and 2 wound necrosis. In 3 caese a revision operation swas performed; 1multiple luxtion of the hip and due to infection of the total femur implant. The range of motion of the hip was 85 degrees (range 30–90) and knee 92 degrees (range 30–110). In nearly all cases we found a lengthening of the revised limb. The general outcome of the patients was. Ten patient were very satisfied, 2 statisfied and 2 fair due to pain persistence. Two patient were mobile with one crutch, 3 used two crutches and one was able to walk with a rollator. One patient was unable to walk due to diplegia after spine fracture. Conclusion. Total femur procedure in final revision arthroplasty has a high potential of perioperative risks but has shown good clinical and mobility results in our patient group. With the Megasystem C® by Link we had a save and good performance while operation of this difficult patient group