Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 137 - 137
1 Sep 2012
Allam A
Full Access

Background. In poliomyelitis; hand to knee gait is the sum of quadriceps weakness and fixed knee flexion deformity. Limb shortening is another added problem. Usually, each problem is attacked separately; with variable end results and complication rates for each procedure. Patients and methods. 22 patients (16–46 y.); with poliomyelitis with hand to knee gait due to fixed knee flexion deformity of mild to moderate degree (10–400); and limb shortening of 4.5–9.5 cm., were managed simultaneously by a single operation. A distal femoral metaphyseal anterior closing wedge (recurvatum) corrective osteotomy was done to treat acutely the fixed knee flexion deformity(and subsequently hand to knee gait). A modified Wagner or Orthofix frame was applied as a mono-plane mono-axial lengthening device to stabilize the osteotomy and to lengthen the short limb. Lengthening was started in all cases two weeks post-operatively. Results. All cases showed full correction of the deformity with elimination of the hand to knee gait problem and all showed - the desired - limb length equalization. The femora were lengthened to an average of 6.4 cm.(= 21% of original femoral bone length), range of lengthening was: 4–9 cm. (= 11–26%). The average healing index was 37 days per centimeter (with a range of 31 to 53 days per centimeter.). Conclusion. Simultaneous management of hand to knee and limb shortening could be achieved by a single osteotomy which is used to extend the knee acutely and for distraction two weeks later using a mono-lateral frame. Results were good, complications were few and accepted and the procedure is well tolerated by the patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 261 - 261
1 Sep 2012
Espandar R Mortazavi SMJ Kaseb MH Haghpanah B Yazdanian S
Full Access

Background. Medial opening-wedge high tibial osteotomy is one of the common surgical procedures in treatment of knee deformities. Many methods have been proposed to fill the medial side osseous gap. The results of using allograft as void filler compared to iliac crest autograft has not been subject to a randomized clinical trial. The purpose of this study was to examine the results of medial opening-wedge high tibial osteotomy using iliac crest allograft as compared to iliac crest autograft. Materials & Methods. Forty-six patients with genovarum deformity were enrolled based on specific inclusion and exclusion criteria and were randomly assigned into two groups. Medial opening-wedge high tibial osteotomy was done using iliac crest allograft (23 patients) or autograft (23 patients) and the osteotomy site was internally fixed using proximal tibial T-plate. All patients were followed-up to 12 months after surgery. Anatomical indices of proximal tibia, complications of treatment, and functional outcome (using WOMAC osteoarthritis index) were assessed for both groups. Results. The amount of correction (degrees), recurrence of the deformity and loss of correction and time to clinical or radiologic union were similar in both groups with no statistically significant difference. Duration of operation was significantly less in allograft group (66.6±3.6 versus 52.9±5.3 minutes, p<0.001). Incidence of surgical site infection did not significantly differ in two groups. No nonunion or delayed union was encountered in either group. Some patients reported more intense postoperative pain in iliac graft harvest site than tibial osteotomy site. Patients in both groups had statistically significant improvement in WOMAC index postoperatively (with no statistically significant difference between groups). Conclusions. According to the results of this study, iliac crest allograft may be safely used in medial opening-wedge high tibial osteotomy with comparable efficacy to iliac crest autograft in patients who do not accept the morbidity of autograft harvest


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 101 - 101
1 Sep 2012
Maempel J Coathup M Calleja N Cannon S Briggs T Blunn G
Full Access

Background. Extendable proximal femoral replacements(PFR) are used in children with bone tumours in proximity to the proximal femoral physis, previously treated by hip disarticulation. Long-axis growth is preserved, allowing limb salvage. Since 1986, survival outcomes after limb salvage and amputation have been known to be equal. Method. Retrospective review of all patients <16years undergoing extendable PFR at Royal National Orthopaedic Hospital (UK) between 04/1996 and 01/2006, recording complications, failures, procedures undertaken and patient outcomes. Results. 8 patients (mean age 8.9±3 years) underwent extendable PFR for Ewing's Sarcoma(5), Osteosarcoma(1), Chondrosarcoma(1) and rhabdomyosarcoma(1). 2 primary PFRs failed (infection of unknown source & local recurrence, both at 26months); 2 required revision for full extension (1 became infected at revision, requiring 2 stage revision). 3 patients had the original prosthesis in situ at last follow-up (mean 7.2;range 3–10.5years). 1 patient had no implant complications, but died (neutropaenic sepsis) 63 days after implant insertion. 2 were treated for recurrence but disease free at last review. 5 were continuously disease free. 5 patients were lengthened a mean 3.7cm; 2 were not lengthened.1 had incomplete data. 5 patients suffered subluxation/dislocation (mean 15.6months), 3 recurrently. Each underwent a mean 1.6 open & 1.4 closed procedures for the displaced joint. 3 patients had 4 open reductions and acetabuloplasties and 2 patients were converted to THR, with 3 major complications: 2 sciatic nerve palsies and 1 (THR) infection. The 5th patient was due for acetabuloplasty but had hip disarticulation for recurrence. Acetabular erosion occurred in 3; 2 were revised to THR (3.5 & 6.8years). 3 patients suffered peri-prosthetic supracondylar fracture (treated conservatively). 5 patients were revised to THR (mean 5.9years): 2 for dislocation, 2 for acetabular erosion & 1 for infection. 1 underwent amputation and another died. Only 1 surviving implant was not converted to THR: this patient had progressive acetabular erosion at 10.5 years & will eventually require THR. The amputee had poor hip function prior to disarticulation but went on to become an international Paralympic sportsman and had very good function 11.4 years post-disarticulation. 3 patients had fixed hip adduction deformity. 1 was isolated and treated with adductor tenotomy, whilst 2 were associated with knee flexion deformity (one required in-patient physiotherapy; the other prosthetic shortening). Conclusions. Extendable PFR permits limb salvage with psychological & functional benefits, but complications are common and some are specific to PFR. Surgery for these may result in further complications. Patients should be warned of the high conversion rate to THR. All the above should be borne in mind when selecting patients. As illustrated above, functional outcome is sometimes better with amputation