Introduction. Total knee arthroplasty (TKA) is a well-established procedure associated with excellent clinical results. We have previously reported that intraoperative knee kinematics correlate with the clinical outcome in mobile bearing TKA. In addition, the intraoperative knee kinematics pattern does not correlate with the degree of preoperative
Introduction. To evaluate the results of correction of
This study was performed at Assiut University, Assiut, Egypt. Anterior distal femoral hemiepiphysiodesis (ADFH) using intra-articular plates for the correction of paediatric fixed
Introduction. The constitutional knee anatomy in the coronal plane includes the distal femoral joint line obliquity (DFJLO) which in most patients is in slight valgus positioning. Despite this native anatomy, the mechanical positioning of the femoral component during primary total knee arthroplasty (TKA) often ignores the native DFJLO opting to place the femur in a set degree of valgus that varies upon the practitioner's practice and experience. Unfortunately, this technique is likely to generate high rate of distal lateral femoral overstuffing. This anatomical mismatch might be a cause of anterior knee pain and therefore partly explain the adverse functional outcomes of mechanically aligned (MA) TKA. Our study aims at assessing the relationship between constitutional knee anatomy and clinical outcomes of MA TKA. We hypothesized that a negative relationship would be found between the constitutional frontal
Introduction. Patients undergoing total knee arthroplasty (TKA) with end-stage osteoarthritis of knee have secondary foot and ankle pathology. Some compensatory changes occur at ankle and subtalar joint secondary to malalignment and deformity at the knee joint. Purpose was to evaluate the changes in hindfoot malalignment and foot deformities in patients with advanced osteoarthritis of knee requiring TKA and effect of correction of
With the success of the medial parapatellar approach (MPA) to total knee arthroplasty (TKA), current research is aimed at reducing iatrogenic microneurovascular and soft tissues damage to the knee. In an effort to avoid disruption to the medial structures of the knee, we propose a novel quadriceps-sparing, subvastus lateralis approach (SLA) to TKA. The aim of the present study is to compare if a SLA can provide adequate exposure of the internal compartment of the knee while reducing soft tissue damage, compared to the MPA. Less disruption of these tissues could translate to better patient outcomes, such as reduced post-operative pain, increased range of motion, reduced instances of patellar maltracking or necrosis, and a shorter recovery time. To determine if adequate exposure could be achieved, the length of the skin incision and perimeter of surgical exposure was compared amongst 22 paired fresh-frozen cadaveric lower limbs (five females/six males) which underwent TKA using the SLA or MPA approach. Additionally, subjective observations which included the percent of visibility of the femoral condyles and tibial plateau, as well as the patellar tracking, were noted in order to qualify adequate exposure. All procedures were conducted by the same surgeon. Subsequently, to determine the extent of soft tissue damage associated with the approaches, an observational assessment of the dynamic and static structures of the knee was performed, in addition to an examination of the microneurovascular structures involved. Dynamic and static structures were assessed by measuring the extent of muscular and ligamentus damage during gross dissection of the internal compartment of the knee. Microneurovascular involvement was evaluated through a microscopic histological examination of the tissue harvested adjacent to the capsular incision. Comparison of the mean exposure perimeter and length of incision was not significantly different between the SLA and the MPA (p>0.05). In fact, on average, the SLA facilitated a 5 mm larger exposure perimeter to the internal compartment, with an 8 mm smaller incision, compared to the MPA, additional investigation is required to assert the clinical implications of these findings. Preliminary analysis of the total visibility of the femoral condyles were comparable between the SLA and MPA, though the tibial plateau visibility appears slightly reduced in the SLA. Analyses of differences in soft tissue damage are in progress. Adequate exposure to the internal compartment of the knee can be achieved using an incision of similar length when the SLA to TKA is performed, compared to the standard MPA. Future studies should evaluate the versatility of the SLA through an examination of specimens with a known degree of
Background. We have performed total knee arthroplasties for valgus and varus in the knees of one person and investigate the clinical characteristics of these patients and the relationship between the kind of deformity and postoperative result. Methods. From March 2002 to February 2010, 25 patients who had simultaneous varus and valgus
Introduction. Valgus deformity in an end stage osteoarthritic knee can be difficult to correct with no clear consensus on case management. Dependent on if the joint can be reduced and the degree of medial laxity or distension, a surgeon must use their discretion on the correct method for adequate lateral releases. Robotic assisted (RA) technology has been shown to have three dimensional (3D) cut accuracy which could assist with addressing these complex cases. The purpose of this work was to determine the number of soft tissue releases and component orientation of valgus cases performed with RA total knee arthroplasty (TKA). Methods. This study was a retrospective chart review of 72 RATKA cases with valgus deformity pre-operatively performed by a single surgeon from July 2016 to December 2017. Initial and final 3D component alignment, knee balancing gaps, component size, and full or partial releases were collected intraoperatively. Post-operatively, radiographs, adverse events, WOMAC total and KOOS Jr scores were collected at 6 months, 1 year and 2 year post-operatively. Results. Pre-operatively,
An osteochondral defect greater than 3cm in diameter and 1cm in depth is best managed by an osteochondral allograft. If there is an associated
Background. Total knee arthroplasty (TKA) is an effective surgical procedure to alleviate excruciating pain and correct dysfunction due to severe
An osteochondral defect greater than 3cm in diameter and 1cm in depth is best managed by an osteochondral allograft. If there is an associated
Introduction. Intramedullary femoral alignment guide is mostly used in total knee arthroplasty (TKA). Accurate preoperative plan is critical to get good alignments when we use intramedullary femoral guide, because the center of femoral head cannot be looked directly during operation. Commonly, the planning is carried out using preoperative anteroposterior radiographs of the femur. The angles formed between mechanical axes of the femur and distal femoral anatomic axes (AMA) are measured as reference angles of resection of distal femur, and the entry points of intramedullary femoral guide are also planned. The purpose of this study is to investigate the influence of femoral position on radiographic planning in TKA. Materials and Methods. We examined 20 knees of 20 female patients who received TKA. Fourteen patients suffered from primary osteoarthritis of the knees, and 6 suffered from rheumatoid arthritis. Fifteen patients have varus
The parameters to be considered in the selection of a cartilage repair strategy are: the diameter of the chondral defect; the depth of the bone defect; the location of the defect (weight bearing); alignment. A chondral defect less than 3 cm in diameter can be managed by surface treatment such as microfracture, autologous chondrocyte transplantation, mosaicplasty, or periosteal grafting. An osteochondral defect less than 3 cm in diameter and less than 1 cm in depth can be managed by autologous chondrocyte transplantation, mosaicplasty or periosteal grafting. An osteochondral defect greater than 3 cm in diameter and 1 cm in depth is best managed by an osteochondral allograft. If there is an associated
Introduction. Limb length discrepancy after THA can result in medicolegal litigation. It can create discomfort for the patient and potentially cause back pain or affect the longevity of the implant. Some patients tolerate the length inequality better compared to others despite difference in anatomical femoral length after surgery. Methods and materials. We analyzed the 3D EOS images of 75 consecutive patients who underwent primary unilateral THA (27 men, 48 women). We measured the 3D length of the femur and tibia (anatomical length), the 3D global anatomical length (the sum of femur and tibia anatomical lengths), the 3D functional length (center of the femoral head to center of the ankle), femoral neck-shaft angle, hip-knee-ankle angle, knee flexum/recurvatum angle, sacral slopes and pelvic incidence. We correlated these parameters with the patient perception of the leg length. Results. The values for leg length and pelvic parameters are shown in table 1. 37 patients had a perception of the LLD (49.3%). When the global anatomical length was shorter on the operated side, the perception of the discrepancy was observed in 56% of the cases. In case of anatomical length longer on the operated side, the perception of the discrepancy was described by the patients in 46% of the cases. The LLD perception was correlated with difference in functional length (p=0.0001), pelvic obliquity (p=0.003) and sacral slope (p=0.023). The anatomical femoral length was not correlated with the LLD perception (p=0,008). Discussion. The perception of LLD is a multifactorial complication. We found that the anatomical femoral length (that can be directly affected by the position of the stem) is not the only important factor. The functional length of the lower extremity which can also be affected by the
Juvenile idiopathic arthritis(JIA) is chronic inflammation commonly occurs in early childhood. Recently, biological therapies are used in JIA at the early stage as same as rheumatoid arthritis, due to retain joint cartilage. However, some of young patients have painful knee problems requiring knee replacement. We experienced 4 cases of JIA treated by knee arthroplasty. The average age at surgery was 33.5 years (range, 26–38 years) with a mean follow-up of 9.5 years (range, 5–18 years). We evaluated the knee range of motion and functional outcomes by the Knee Society Score (KSS), implant selection, postoperative complication, surgery of another joint. Mean range of motion improved from 76.3° (0°–120°) at pre-operation to 110.6° (80°–130°) at post-operation (P<0.05). Mean KSS increased from 47.3 ±20.1 preoperatively to 86.9 ±11.1 (P<0.01) at last follow-up and the mean KSS function from 27.5 ±25.9 to 62.5±20.2 at last follow-up (P<0.05). All of the TKAs were cemented, 5 were cruciate-retaining implant designs, whereas 2 TKAs had constrained posterior stabilized implant designs. Patellar resurfacing was undergone in all knees. Bone graft required in 1 knee within severe
No, Neutral mechanical axis has never been regarded as “necessary” to the success of TKA. In fact it has never been established as “ideal” with published data. Tibial femoral alignment after TKA is important, but it is also an issue that we do not understand completely. Neutral mechanical alignment refers to the relationship between the mechanical axes of the femur and tibia as shown on full length radiographs. “Neutral” means that these axes are collinear, i.e. that a line may be drawn from the center of the hip to the center of the ankle and it will intersect the center of the knee joint. The allure of the “straight line” has led many surgeons to regard a neutral mechanical axis as “perfection” for TKA surgery, but indeed, it is not the usual “normal” alignment for most human knees, nor is it the target for many conventional knee replacements. The “neutral mechanical axis” represents OVERCORRECTION for most knees. Moreland demonstrated in 1987 that few human knee joints are naturally aligned “in neutral”, but with the line from center of hip to center of ankle passing through the medial compartment. This tendency to relative varus mechanical axis in most human knees was corroborated by Bellemans et al in 2012. They substituted the word “constitutional varus” for what would otherwise be known as “normal alignment”. In general, patients with pathologic or significant varus alignment, whose arthroplasties have been performed competently, are at greatest risk for failure by wear, osteolysis and loosening. This is the prototypical failure mechanism that pre-occupied the surgeons responsible for making knee arthroplasty successful in the 1970s. The first paper to identify varus TKA alignment and failure due to loosening was Lotke and Ecker in 1977. They worked from short radiographs and ushered in an era of careful attention to valgus TKA alignment-not neutral alignment. Correction of varus deformity combined with ligament balancing was probably responsible for making condylar type knee arthroplasties work durably in the early days. Full length radiographs, used by Kennedy and White in 1987 to study alignment in unicompartmental arthroplasties, provide a more sophisticated method of evaluating knee alignment. These studies must be aligned with correct rotation to be valid. Computerised navigation was probably responsible for some surgeon's dedication to the neutral mechanical axis. The study of Parratte et al from Mayo has received much attention and argued that a neutral mechanical axis did NOT improve success rates at 15 years. It should be noted that these TKA's were expertly performed and even the less well-aligned cases were not “excessively” malaligned. This study does not state that alignment is irrelevant to the success of TKA, but rather that a range of alignments (with stability) might be expected to produce a durable arthroplasty. Concurrent with these developments has been an interest in “under-correcting”
Purpose. There is a large gap between UKA and TKA in terms of tissue preservation including bone stock and knee ligament. We have recently introduced bicompartmental UKA (Bi-UKA) to fill the gap and achieve more “physiological” knee than TKA. In this study, we report the short-term results of Bi-UKA. Subjects and Methods. Thirty knees in twenty-nine osteoarthritis patients who underwent Bi-UKA from December 2010 to December 2013 (6 males and 23 females, average age of 75) were clinically and radiologically evaluated with an average observation period of 19 months. The operative indications were (1)confirmed diagnosis of medial and lateral osteoarthritis or osteonecrosis with preserved status of patellofemoral joint; (2)range of knee flexion greater than 110°; (3)flexion contracture less than 20°; (4)clinically stable knee in the frontal and sagittal plane; (5)correctable
Introduction. Clinical outcomes for total knee arthroplasty (TKA) are especially sensitive to lower extremity alignment and implant positioning. 1. The use of computer-assisted orthopaedic surgery (CAOS) can improve overall TKA accuracy. 2. This study assessed the accuracy of an image-free CAOS guidance system (Exactech GPS, Blue-Ortho, Grenoble, FR) in both a synthetic leg with a normal mechanical axis and legs with abnormal mechanical axis. Materials and methods. A high-resolution 3D scanner (Comet L3D, Steinbichler, Plymouth, MI) was used to scan varus-deformed (n=12), neutral (n=12), and valgus-deformed (n=4) knee inserts (Mita M-00566, M-00598, M-00567; respectively, Medical Models, Bristol, UK) and collect pre-identified anatomical landmarks prior to using the models to simulate knee surgery. The image-free CAOS guidance system was then used to acquire the same landmarks. After adjusting the position and orientation of the cutting block to match the targets, bone resections were performed, and the knee models were re-scanned. The 3D scans made before and after the cuts were overlaid and the resection parameters calculated using the pre-identified anatomical landmark data and advanced software (UG NX, Siemens PLM, Plano, TX). Data sets obtained from the 3D scanner (see Figure 1A) were compared with data sets from the guidance system (see Figure 1B). Given the accuracy of the 3D scanner (<50μm), its measurements were used as the baseline for assessing CAOS system error. Results. Table I shows errors in bone resection thickness orientation measurement errors as well as CAOS system confidence intervals (CI) for both the tibia and femur, depending on deformity type. Regardless of
Backgrounds. Most of in vivo kinematic studies of total knee arthroplasty (TKA) have reported on varus knee. TKA for the valgus
Patients planning to undergo total knee arthroplasty (TKA), especially in Asian and Middle Eastern countries, usually expect to be able to perform activities requiring knee flexion such as sitting cross-legged or kneeling with ease after the surgery. Postoperative range of motion (ROM) can be affected by multiple factors such as the patient's gender, age, preoperative ROM, diagnosis, the surgeon's technique, the pre- and post-operative rehabilitation program, and the design of the prosthesis. Among these, the choice of the prosthesis depends on the surgeon's preference. As a result, several trials and studies have been conducted to improve postoperative ROM by modifying prosthesis design. The present study aimed to examine the results of TKA with the NexGen LPS-Flex system (Zimmer, Warsaw, Indiana), which is one of several high-flexion total knee prostheses that were designed to achieve a wide ROM for osteoarthritis in the valgus knee. A total of 27 primary TKAs in 26 osteoarthritis patients with valgus