Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 3 - 3
3 Mar 2023
Roy K Joshi P Ali I Shenoy P Syed A Barlow D Malek I Joshi Y
Full Access

Classifying trochlear dysplasia (TD) is useful to determine the treatment options for patients suffering from patellofemoral instability (PFI). There is no consensus on which classification system is more reliable and reproducible for this purpose to guide clinicians in order to treat PFI. There are also concerns about validity of the Dejour classification (DJC), which is the most widely used classification for TD, having only a fair reliability score.

The Oswestry-Bristol classification (OBC) is a recently proposed system of classification of TD and the authors report a fair-to-good interobserver agreement and good-to-excellent intra-observer agreement in the assessment of TD. The aim of this study was to compare the reliability and reproducibility of these two classifications.

6 assessors (4 consultants and 2 registrars) independently evaluated 100 magnetic resonance axial images of the patella-femoral joint for TD and classified them according to OBC and DJC. These assessments were again repeated by all raters after 4 weeks. The inter and intra-observer reliability scores were calculated using Cohen's kappa and Cronbach's alpha.

Both classifications showed good to excellent interobserver reliability with high alpha scores. The OBC classification showed a substantial intra-observer agreement (mean kappa 0.628)[p<0.005] whereas the DJC showed a moderate agreement (mean kappa 0.572) [p<0.005]. There was no significant difference in the kappa values when comparing the assessments by consultants to those by registrars, in either classification systems.

This large study from a non-founding institute shows both classification systems to be reliable for classifying TD based on magnetic resonance axial images of the patella-femoral joint, with the simple to use OBC having a higher intra-observer reliability score compared to the DJC.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 34 - 34
1 Nov 2022
Haleem S Malik M Azzopardi C Botchu R Marks D
Full Access

Abstract. Purpose. Intracanal rib head penetration is a well-known entity in dystrophic scoliotic curves in neurofibromatosis type 1. There is potential for spinal cord injury if this is not recognised and managed appropriately. No current CT-based classification system is currently in use to quantify rib head penetration. This study aims to propose and evaluate a novel CT-based classification for rib head penetration primarily for neurofibromatosis but which can also be utilised in other conditions of rib head penetration. Materials and methods. The grading was developed as four grades: normal rib head (RH) position—Grade 0, subluxed ext-racanal RH position—Grade 1, RH at pedicle—Grade 2, intracanal RH—Grade 3. Grade 3 was further classified depending on the head position in the canal divided into thirds. Rib head penetration into proximal third (from ipsilateral side)—Grade 3A, into the middle third—Grade 3B and into the distal third—Grade 3C. Seventy-five axial CT images of Neurofibromatosis Type 1 patients in the paediatric age group were reviewed by a radiologist and a spinal surgeon independently to assess interobserver and intraobserver agreement of the novel CT classification. Agreement analysis was performed using the weighted Kappa statistic. Results. There was substantial interobserver correlation with mean Kappa score (k = 0.8, 95% CI 0.7–0.9) and near perfect intraobserver Kappa of 1.0 (95% CI 0.9–1.0) and 0.9 (95% CI 0.9–1.0) for the two readers. Conclusion. The novel CT-based classification quantifies rib head penetration which aids in management planning


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 31 - 31
1 Jan 2022
Haleem S Malik M Guduri V Azzopardi C James S Botchu R
Full Access

Abstract. Purpose. No clinical CT based classification system is currently in use for Lumbar Foraminal Stenosis. MRI scanners are not easily available, are expensive and may be contraindicated in an increasing number of patients. This study aims to propose and evaluate the reproducibility of a novel CT based classification for lumbar foraminal stenosis. Materials and Methods. The grading was developed as 4 grades. Normal foramen – Grade 0, Anteroposterior(AP)/Superoinferior (SI)(single plane) fat compression – Grade 1, Both AP/SI compression (two planes) – Grade 2 (both AP and SI) without distortion of nerve root, Grade 2 with distortion of nerve root – Grade 3. 800 lumbar foramen of a cohort of 100 random patients over the age of 60 who had undergone both CT and MRI scans were reviewed by two radiologists independently to assess agreement of the novel CT classification against the MRI based grading system of Lee et al. Interobserver(n=400) and intraobserver agreement(n=160) was also evaluated. Agreement analysis was performed using the Weighted Kappa statistic. Results. 100 patients (M:F = 45:55) with a mean age of 68.5 years (range 60 – 83 years were included in the study. The duration between CT and MRI scans was 98 days(range 0 – 540, SD – 108). There was good correlation between CT and MRI with Kappa scores (k=0.81) and intraobserver Kappa of 0.89 and 0.98 for the two readers. Conclusion. The novel CT based classification correlates well with the MRI grading system and can safely and accurately replace it where required


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 7 - 7
1 Jul 2020
Schaeffer E Teo T Cherukupalli A Cooper A Aroojis A Sankar W Upasani V Carsen S Mulpuri K Bone J Reilly CW
Full Access

The Gartland extension-type supracondylar humerus fracture is the most common elbow fracture in the paediatric population. Depending on fracture classification, treatment options range from nonoperative treatment such as taping, splinting or casting to operative treatments such as closed reduction and percutaneous pinning or open reduction. Classification variability between surgeons is a potential contributing factor to existing controversy over nonoperative versus operative treatment for Type II supracondylar fractures. The purpose of this study was to investigate levels of agreement in classification of extension-type supracondylar humerus fractures using the Gartland classification system. A retrospective chart review was conducted on patients aged 2–12 years who had sustained an extension-type supracondylar fracture and received either operative or nonoperative treatment at a tertiary children's hospital. De-identified baseline anteroposterior (AP) and lateral plain elbow radiographs were provided along with a brief summary of the modified Gartland classification system to surgeons across Canada, United States, Australia, United Kingdom and India. Each surgeon was blinded to patient treatment and asked to classify the fractures as Type I, IIA, IIB or III according to the classification system provided. A total of 21 paediatric orthopaedic surgeons completed one round of classification, of these, 15 completed a second round using the same radiographs in a reshuffled order. Kappa values using pre-determined weighted kappa coefficients were calculated to assess interobserver and intraobserver levels of agreement. In total, 60 sets of baseline elbow radiographs were provided to survey respondents. Interobserver agreement for classification based on the Gartland criteria between surgeons was a mean of 0.68, 95% CI [0.67, 0.69] (0.61–0.80 considered substantial agreement). Intraobserver agreement was a mean of 0.80 [0.75, 0.84]. (0.61–0.80 substantial agreement, 0.81–1 almost perfect agreement). Radiographic classification of extension-type supracondylar humerus fractures at baseline demonstrated substantial agreement both between and within surgeon raters. Levels of agreement are substantial enough to suggest that classification variability is not a major contributing factor to variability in treatment between surgeons for Type II supracondylar fractures. Further research is needed to compare patient outcomes between nonoperative and operative treatment for these fractures, so as to establish consensus and a standardized treatment protocol for optimal patient care across centres


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 17 - 17
1 Dec 2017
Knez D Mohar J Cirman RJ Likar B Pernuš F Vrtovec T
Full Access

We present an analysis of manual and computer-assisted preoperative pedicle screw placement planning. Preoperative planning of 256 pedicle screws was performed manually twice by two experienced spine surgeons (M1 and M2) and automatically once by a computer-assisted method (C) on three-dimensional computed tomography images of 17 patients with thoracic spinal deformities. Statistical analysis was performed to obtain the intraobserver and interobserver variability for the pedicle screw size (i.e. diameter and length) and insertion trajectory (i.e. pedicle crossing point, sagittal and axial inclination, and normalized screw fastening strength). In our previous study, we showed that the differences among both manual plannings (M1 and M2) and computer-assisted planning (C) are comparable to the differences between manual plannings, except for the pedicle screw inclination in the sagittal plane. In this study, however, we obtained also the intraobserver variability for both manual plannings (M1 and M2), which revealed that larger differences occurred again for the sagittal screw inclination, especially in the case of manual planning M2 with average differences of up to 18.3°. On the other hand, the interobserver variability analysis revealed that the intraobserver variability for each pedicle screw parameter was, in terms of magnitude, comparable to the interobserver variability among both manual and computer-assisted plannings. The results indicate that computer-assisted pedicle screw placement planning is not only more reproducible and faster than, but also as reliable as manual planning


Introduction. Patient-specific cutting guides entered into clinical practice few years ago, first introduced in total knee replacement and recently also for other joint replacements. Advantages claimed are improving accuracy and repeatability in implant placement. New patient-specific guides to perform an accurate femoral neck resection and provide a precise alignment reference for acetabular reaming in total hip arthroplasty (THA) were recently developed by Medacta International: MyHip Technology. To date femoral guides can be designed for both anterior and posterior approaches, whereas acetabular guides are available only for posterior approach. Evaluation of the repeatability and reproducibility of MyHip guides placement on cadavers is performed using a navigation system. Accuracy of femoral MyHip guides is evaluated also through one author's clinical experience (RP). Materials and Methods. During each cadaveric session one body (2 hips) was available. A pre-operative CT scan has been obtained and used in order to create the 3D bone model of the pelvis and proximal femurs. Afterwards, a surgical planning for THA has been performed for each case, and, once it was approved by the surgeons, the designed patient-specific blocks were made. Intraobserver and interobserver agreement in positioning the guides was assessed getting measures of femoral head resection height (mm), femoral head plane inclination/anteversion (°) and acetabular reaming axis orientation (°). 9 surgeons, through 2 cadaveric sessions, positioned each guide, removed it and re-positioned it 5 times alternatively. The system is judged as accurate if all measures differ less than 3mm and 5°for lengths and angles respectively from the average among all the acquisitions. Clinical experience includes 68 THA which were performed between March 2014 and April 2015. Anterior femoral MyHip guides were used for the femoral head resection, while the acetabular side was prepared using the standard metal instrumentation for minimally invasive anterior approach. Intra-operative complications, as well post-operative leg length difference and implant positioning are assessed. Results. During cadaveric sessions, all measures taken meet the acceptance criteria with the exception of two measures, which are −5,98° and −5,57°, in femoral head plane anteversion and inclination respectively with femoral anterior guides. Looking at intraobserver variation, MyHip Femoral anterior guide positioning average deviation was between −0.91 mm and 1.44 mm (resection height), −1.25° and 1.41° (anteversion), and −0.85° and 0.82° (inclination); MyHip Femoral posterior guide positioning average deviation was between −0.47 mm and 0.67 mm (resection height), −1.33° and 1.50° (anteversion), −0.66° and 1.50° (inclination); MyHip Acetabular posterior guide had an average z-axis deviation from the mean value between −0.91° and 0.91°. All surgeries were successfully performed. The surgeon feels a good fitting and stability of the guide during each surgery. A preliminary analysis suggests optimal outcomes in terms of accurate prosthetic component positioning and reduction of occurrence of leg length inequality. Conclusion. Cadaveric sessions show intraobserver and intraobserver agreement, demonstrating reproducibility and repeatability in placement of MyHip patient specific cutting guides. Clinical experience confirms the advantages claimed by this technique, suggesting a possible reduction of complications usually linked to implant malpositioning, such as wear, impingement, risk of luxation


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 39 - 39
1 Jul 2020
Le V Escudero M Wing K Younger ASE Penner M Veljkovic A
Full Access

Restoration of ankle alignment is thought to be critical in total ankle arthroplasty (TAA) outcomes, but previous research is primarily focused on coronal alignment. The purpose of this study was to investigate the sagittal alignment of the talar component. The talar component inclination, measured by the previously-described gamma angle, was hypothesized to be predictive of TAA outcomes. A retrospective review of the Canadian Orthopaedic Foot and Ankle Society (COFAS) database of ankle arthritis was performed on all TAA cases at a single center over a 11-year period utilizing one of two modern implant designs. Cases without postoperative x-rays taken between 6 and 12 weeks were excluded. The gamma angle was measured by two independent orthopaedic surgeons twice each and standard descriptive statistics was done in addition to a survival analysis. The postoperative gamma angles were analyzed against several definitions of TAA failure and patient-reported outcome measures from the COFAS database by an expert biostatistician. 109 TAA cases satisfied inclusion and exclusion criteria. An elevated postoperative gamma angle higher than 22 degrees was associated with talar component subsidence, defined as a change in gamma angle of 5 degrees or more between postoperative and last available followup radiographs. This finding was true when adjusting for age, gender, body mass index (BMI), and inflammatory arthritis status. All measured angles were found to have good inter- and intraobserver reliability. Surgeons should take care to not excessively dorsiflex the talar cuts during TAA surgery. The gamma angle is a simple and reliable radiographic measurement to predict long-term outcomes of TAA and can help surgeons counsel their patients postoperatively


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 45 - 45
1 Jul 2020
Mahmood F Burt J Bailey O Clarke J Baines J
Full Access

In the vast majority of patients, the anatomical and mechanical axes of the tibia in the coronal plane are widely accepted to be equivalent. This philosophy guides the design and placement of orthopaedic implants within the tibia and in both the knee and ankle joints. However, the presence of coronal tibial bowing may result in a difference between these two axes and hence cause suboptimal placement of implanted prostheses. Although the prevalence of tibial bowing in adults has been reported in Asian populations, to date no exploration of this phenomenon in a Western population has been conducted. The aim of this study was to quantify the prevalence of coronal tibial bowing in a Western population. This was an observational retrospective cohort study using anteroposterior long leg radiographs collected prior to total knee arthroplasty in our high volume arthroplasty unit. Radiographs were reviewed using a Picture Archiving and Communication System. Using a technique previously described in the literature for assessment of tibial bowing, two lines were drawn, each one third of the length of the tibia. The first line was drawn between the tibial spines and the centre of the proximal third of the tibial medullary canal. The second was drawn from the midpoint of the talar dome to the centre of the distal third of the tibial medullary canal. The angle subtended by these two lines was used to determine the presence of bowing. Bowing was deemed significant if more than two degrees. The position of the apex of the bow determined whether it was medial or lateral. Measurements were conducted by a single observer and 10% of measurements were repeated by the same observer and also by two separate observers to allow calculation of intraclass correlation coefficients (ICCs). A total of 975 radiographs consecutively performed in the calendar years 2015–16 were reviewed, 485 of the left leg and 490 of the right. In total 399 (40.9%) tibiae were deemed to have bowing more than two degrees. 232 (23.8%) tibiae were bowed medially and 167 (17.1%) were bowed laterally. The mean bowing angle was 3.51° (s.d. 1.24°) medially and 3.52° (s.d. 1.33°) laterally. Twenty-three patients in each group (9.9% medial/13.7% lateral) were bowed more than five degrees. The distribution of bowing angles followed a normal distribution, with the maximal angle observed 10.45° medially and 9.74° laterally. An intraobserver ICC of 0.97 and a mean interobserver ICC of 0.77 were calculated, indicating excellent reliability. This is the first study reporting the prevalence of tibial bowing in a Western population. In a significant proportion of our sample, there was divergence between the anatomical and mechanical axes of the tibia. This finding has implications for both the design and implantation of orthopaedic prostheses, particularly in total knee arthroplasty. Further research is necessary to investigate whether prosthetic implantation based on the mechanical axis in bowed tibias results in suboptimal implant placement and adverse clinical outcomes


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 51 - 51
1 Jan 2013
Xypnitos F Sims A Weusten A Rangan A
Full Access

Background. Accurate and reproducible radiological assessment of shoulder replacement prostheses over time is important for identifying failure or to provide reassurance. A number of clearly defined radiological parameters have been described to help standardise the radiological assessment of prostheses. To our knowledge, this is the first study conducted to test the reproducibility and reliability of these measurements. Aim. The aim of this work was to test intraobserver reproducibility and interobserver reliability in the measurement of humeral component orientation (HCO), humeral head offset (HHO), humeral head size (HHS), humeral head height (HHH), and acromiohumeral distance (AHD.). Materials and methods. A cohort of 67 patients who had previously undergone shoulder replacement was identified. Two independent reviewers studied the same AP radiograph of each patient on two occasions, at an interval of one month. Results. There was strong agreement for measurements of humeral head size (ICC=0.83), moderate agreement for humeral head offset (0.66), humeral head height (0.68) and acromio-humeral distance (0.66) and fair agreement for humeral component orientation (0.44). Conclusions. Interobserver reliability and intraobserver reproducibility of radiological measurements are important factors to consider when designing longitudinal or multi-centre studies of shoulder replacement prostheses


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 222 - 222
1 Jun 2012
Speranza A Maestri B Monaco E D'arrigo C Ferretti A
Full Access

Manual postoperative CT calculation of anteversion and inclination of the acetabular cup can be inaccurate and depends on the observer's experience. The aim of this study is to describe and present a validation of a new CT-image-based dedicate software (EGIT) for calculation of the acetabular component placement. The software principle is based on a three-dimensional reconstruction of a patient's bones from anatomical data collected postoperatively on the patient's CT scan. 15 Patient to be operated for THR were enrolled in this study. All patients were evaluated with post operative CT-scan. Measurement of Cup positioning were performed with two different methods: a manual method, performed by an expert radiologist, and a software CT image based method. Statistical analysis was performed with Intraclass Correlation Coefficent to asses interobserver and intraobserver reliability. A paired T-test was used to detect differences between manual and software methods. The Intraclass Correlation Coefficient was excellent for both the intraobserver and interobserver reliability. As expected the ICC is higher in the interobserver case. A mean cup anteversion of 14.2 (S.D. ±6.9), mean inclination of 44.2 (S.D.± 5.8) are detected with EGIT by the expert surgeon; Mean Cup anteversion of 13.6 (S.D. ± 5.11), mean inclination of 43.3 (S.D.± 5.1) are detected with manual method by expert radiologist. No statistical difference have been found (P> 0.05). The EGIT software seems to be an easy, accurate and reproducible method to calculate acetabular cup positioning using standard post-operative CT scan in THA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 6 - 6
1 Mar 2013
King R Ikram A
Full Access

Background. This is an epidemiological study of patients with middle third clavicle fractures presenting to a tertiary hospital. The data is used to formulate a classification system for middle third clavicle fractures based on fracture configuration and displacement. Description of methods. Patients presenting primarily to a referral hospital with middle third clavicle fractures were identified using the PACS radiology system. The radiographs were reviewed to determine the fracture type, displacement, shortening and amount of comminution. The clinical notes of each patient were reviewed to determine the mechanism of injury, soft tissue status, neurovascular status and treatment rendered. A novel classification system was developed to describe the different fracture configurations seen in the group. The interobserver and intraobserver correlation of the classification system as well as the ability of the classification system to predict treatment were tested. Summary of results. Three hundred and three patients were included in the review, 223 males and 80 females. Middle third clavicle fractures were displaced in 69% of cases. Displaced fractures tend to have a significant amount of displacement and shortening in most cases with averages of 19.64mm (Std Dev. 6.901) and 19.15mm (Std Dev. 9.616) respectively. Acceptable interobserver and intraobserver correlation levels were shown for the proposed classification system. Conclusion. The epidemiology of middle third clavicle fractures found in the population studied differs substantially from first world populations. It underlines the high level of road traffic accidents and interpersonal violence seen in South Africa. Surgeons treating clavicle fractures are still divided on the indications for surgery with little correlation found between the fracture type and displacement on radiographs and the type of treatment rendered. The classification system provides guidelines to treating surgeons to the correct treatment modality. MULTIPLE DISCLOSURES


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 3 - 3
1 Sep 2012
Elnikety S El-Husseiny M Kamal T Gregoras M Talawadekar G Jeer PJS
Full Access

The transtibial approach is widely used for femoral tunnel positioning in ACL reconstruction. Controversy exists over the superiority of this approach over others. Few studies reflected on the reproducibility rates of the femoral tunnel position in relation to the approach used. We reviewed AP and Lat X-ray radiographs post isolated ACL reconstruction for 180 patients for femoral tunnel position, tibial tunnel position and graft inclination angle. All patients had their operations performed by one surgeon in one hospital between March 2006 and Sep 2010. All operations were performed using one standard technique using transtibial approach for femoral tunnel positioning. Two orthopaedic fellows, with similar experiences, reviewed blinded radiographs. A second reading was done 8 weeks later. Pearson inter-observer, intra-observer correlation and Bland-Altman agreements plots statistical analyses were done. Mean age was 29 years (range 16–54), Pearson intra-observer correlation shows substantial to perfect agreement while Pearson's inter-observer correlation shows moderate to substantial agreement. Previous literature proved that optimal femoral tunnel position for the best clinical and biomechanical outcome is for the centre of the tunnel to be at 43% from the lateral end of the width of the femoral condyles on the AP view and at 86% from the anterior end of the Blumensaat's line on the lateral view. In our study 85% of the femoral tunnels were within +/− 5% of the optimal tunnel position on the AP views, and more than 70% of the femoral tunnels were within +/−5% of the optimal tunnel position on the Lateral view. Interobserver and intraobserver corelations show moderate to substantial agreement, Bland-Altman agreement plots show substantial agreements for interobserver and intraobserver measurements. These results were found to be statistically significant at 0.01. Based on our results we conclude that using one standardised transtibial technique for ACL reconstruction can result in high reproducibility rates of optimal femoral tunnel position. Further studies are needed to validate our results and to study the reproducibility rates for different approaches and techniques


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 38 - 38
1 Mar 2013
Shon WY Suh DH Chun SK
Full Access

Introduction. Periprosthetic osteolysis following total hip arthroplasty is caused mainly by polyethylene wear particles and necessitates revision surgery at some stage even in the presence of well-fixed implants. Therefore, methods to estimate the polyethylene wear become important, with manual wear measurement methods as the main outcome measurement even in the presence of computer-assisted measurement methods on account of easy availability and simplicity in their use with reasonable accuracy. The purposes of this study were to quantify the accuracy and reproducibility of the slide presentation software method on clinical radiographs and to compare it with that of the previously described Livermore's method, and to determine the usefulness of the slide presentation software methods for highly cross linked polyethylene wear measurement. Materials and Methods. 81 hips out of 61 patients who underwent primary total hip arthroplasty between October 2000 and January 2006 were retrospectively evaluated for polyethylene wear by two independent observers using the Livermore's and the slide presentation software methods. All the hips were implanted with highly cross linked polyethylene acetabular liners with cementless acetabular components. The 28 mm sized cobalt chrome alloy femoral heads were used in all cases. The mean age of the patients was 50.8 years(range, 27–73 years), and the mean follow-up period was 6.6 years (range, 2–11 years). Paired radiographs were analyzed using the Livermore's and the slide presentation software method. For the Livermore's methods, radiographs were magnified to 200%, printed, and readings taken with digital calipers with an accuracy of 0.01 mm(Figure 1). For the slide presentation software method, we used Microsoft Office PowerPoint software(Microsoft Corp., Redmond, WA, USA) as described in a previous our study(Figure 2). Results. The mean polyethylene wear rate in 81 hips measured by the Livermore's method was found to be 0.071±0.12 and 0.081±0.09 mm/year by observer 1 and 2 respectively. The mean polyethyelene wear rate measured by slide presentation software method was found to be equally 0.069±0.07 mm/year by observer 1 and 2. Interobserver and intraobserver variance were evaluated using Pearson correlation coefficient. Correlation coefficients for interobserver variance were 0.802 for the Livermore's method and 0.979 for the slide presentation software method. Correlation coefficient for intraobserver variance were 0.777 for the Livermore's method and 0.965 for the slide presentation software method in observer 1, 0.303 for the Livermore's method and 0.941 for the slide presentation software method. The mean time consumed in each radiographic measurement with the Livermore's method was 15.52 minutes (range, 10.67–22 minutes) as compared to 9.55 minutes (range, 5.42–13.5 minutes) measured with the slide presentation software method (p < 0.001). Conclusion. The slide presentation software method was more accurate in serial intra-observer measurements and more reproducible in inter-observer readings for polyethylene wear than the traditional Livermore method, and was simple to use and less time consuming. Not all orthopaedic surgeons have access to CT for measuring polyethylene wear, hence the use of this type of manual method becomes a necessity on account of its easy availability and repeatability in serial measurements


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 31 - 31
1 Apr 2018
Kim W Kim D Rhie T Oh J
Full Access

Background. Humeral retroversion is variable among individuals, and there are several measurement methods. This study was conducted to compare the concordance and reliability between the standard method and 5 other measurement methods on Twodimensional (2D) computed tomography (CT) scans. Methods. CT scans from 21 patients who underwent shoulder arthroplasty (19 women and 2 men; mean age, 70.1 years [range, 42 to 81 years]) were analyzed. The elbow transepicondylar axis was used as a distal reference. Proximal reference points included the central humeral head axis (standard method), the axis of the humeral center to 9 mm posterior to the posterior margin of the bicipital groove (method 1), the central axis of the bicipital groove –30° (method 2), the base axis of the triangular shaped metaphysis +2.5° (method 3), the distal humeral head central axis +2.4° (method 4), and contralateral humeral head retroversion (method 5). Measurements were conducted independently by two orthopedic surgeons. Results. The mean humeral retroversion was 31.42° ± 12.10° using the standard method, and 29.70° ± 11.66° (method 1), 30.64°± 11.24° (method 2), 30.41° ± 11.17° (method 3), 32.14° ± 11.70° (method 4), and 34.15° ± 11.47° (method 5) for the other methods. Interobserver reliability and intraobserver reliability exceeded 0.75 for all methods. On the test to evaluate the equality of the standard method to the other methods, the intraclass correlation coefficients (ICCs) of method 2 and method 4 were different from the ICC of the standard method in surgeon A (p < 0.05), and the ICCs of method 2 and method 3 were different form the ICC of the standard method in surgeon B (p < 0.05). Conclusions. Humeral version measurement using the posterior margin of the bicipital groove (method 1) would be most concordant with the standard method even though all 5 methods showed excellent agreements


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 25 - 25
1 Jan 2016
Stevens A Wilson C Shunmugam M Ranawat V Krishnan J
Full Access

Inter- and intra-observer variation has been noted in the analysis of radiographic examinations with regard to experience of surgeons, and the monitors used for conducting the evaluations. The aim of this study is to evaluate inter/intra observer variation in the measurement of mechanical alignment from long-leg radiographs. 40 patients from the elective waiting list for TKA underwent long leg radiographs pre-operatively and 6 months post-operatively (total of 80 radiographs). The x-rays were analysed by 5 observers ranging in experience from medical student to head orthopaedic surgeon. Two observers re-analysed their results 6 months later to determine intraobserver correlation, and one observer re-measured the alignment on a different monitor. These measurements were all conducted blindly and none of the observers had access to the others’ results. 80 radiographs were analysed in total, 40 pre-op and 40 post-op. The mechanical alignment was analysed using Pearson's correlation (r = 0 no agreement, r = 1 perfect agreement) and revealed that experience as an orthopaedic surgeon has little effect on the measurement of mechanical alignment from long leg radiograph. The results for the different monitor analysis were also analysed using Pearson's correlation of long leg alignment. Monitor quality does seem to affect the correlation between alignment measurements when reviewing both intra and inter observer correlation on different computer monitors. Surgical experience has little impact on the measurement of alignment on long leg radiographs. Of greater concern is that monitors of different resolution can affect measurement of mechanical alignment. As there might be a range of monitors in use in different institutions, and also in outpatient clinics to surgical theatres, close attention should be paid to the implications of these results


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 29 - 29
1 May 2016
Shibanuma N Ishida K Kodato K Oka S Toda A Tateishi H
Full Access

Purpose. It is generally accepted that the cement mantle surrounding the femoral component of a cemented total hip arthroplasty (THA) should be complete without any defects, and of at least 2 mm in thickness. Radiographic evaluation is the basis for assessment of the cement mantle. The adequacy of radiographic interpretation is subject to debate. Poor interobserver and intraobserver reproducibility of radiographic cement mantle assessment has been reported. In this study, 3D template software was used that allow anatomical measurements and analysis of three-dimensional digital femura geometry based on CT scans. The purpose of this study is to analyze the three-dimensional cement mantle thickness of cemented hip stem. Materials and Methods. 52 hips that underwent THA with Exeter stem (Stryker Orthopaedics, Mahwah, NJ) were enrolled in this study. All surgeries were performed by a single surgeon. There were 49 hips in 49 women and 3 hips in 3 men. The average age at surgery was 73 years (range, 60–88 years). The etiology of the hip lesions were osteoarthrosis in 49, rheumatoid arthritis in 3, and osteonecrosis of the femoral head in 1. For preoperative and postoperative evaluation, a CT scan of the pelvis and knee joint was obtained and was transferred to 3D template software (Zed hip, Lexi, Tokyo, Japan). We evaluated the alignment for stem anteversion/valgus/anterior tilt angles and the contact of the cortical bone with the cement mantle was evaluated. Results. Concerning the alignment of the stems, variability was observed in the anteversion; however, the stems were inserted in an almost neutral position in varus-valgus and extension-flexion. The 3D contact of the stems with a cement mantle of 2 mm added with the cortical bone was evaluated, and it could be broadly classified into three patterns: cases in which the cortical bone was not reamed in the range of 2 mm from the stem, those in which the distal medial part was partially reamed, and cases in which the distal anterior and medial parts of the cortical bone were reamed in a relatively wide range. In this study, there were 17 patients with no reaming, 32 patients with partial reaming, and 3 patients with a relatively large range of reaming. Discussion and Conclusion. Oversizing of the stem associated with incomplete cement mantles has been suggested to account for early femoral component loosening. In this study, 3 patients whose cortical bone was reamed in a relatively wide range and who had a risk of partial thinning of the cement mantle as a result were observed. The effect of reaming of the cortical bone on the clinical results is still unknown; however, a careful follow-up in the future may be required


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 88 - 88
1 Jan 2016
Van Der Straeten C Van Onsem S Callens R Slabbaert M Victor J
Full Access

Background. The use of Computed Tomography (CT) as a medical imaging tool has widespread applications in the field of knee surgery. Surgeons use a CT scan in a conventional way during the pre-operative stage, to plan the position of the femoral component in the horizontal plane. In the post-operative stage, the use of a CT scan is a routine tool in the evaluation of failed TKA as rotational malalignment of the femoral component has been determined as a cause of poor clinical outcome after TKA. Aim. How accurately can we measure the different angles with importance for alignment on a 3D-image in comparison to a standard CT, 2D, image. Material and methods. This study includes patients above 55 years of age who were scheduled for a TKA at our centre and who had a pre- and postoperative full-leg length computed tomography (CT). These images were analysed using Mimics V 16.0 ® and 3-matic V 8.0 ® (Materialise, Haasrode, Belgium) to create the surface reconstruction and perform the 3D-measurements. Different angles were measured pre- and post-operatively on these images both in 2D as in 3D: condylar twist angle (CTA), posterior condylar angle (PCA), hip-knee-ankle angle (HKA), tibiofemoral rotation angle (TFRA), posterior tilt of the tibial implant (STPA) and the frontal plane angle of the tibial implant (FTPA). A power analysis showed a needed sample size of 18 patients. Pre-operatively 21 patients were included, 18 of them also received a post-operative full-leg CT. Three observers participated in the study and they all performed all analyses twice with a minimum interval of one week for obtaining intra-observer repeatability. Statistical analysis was performed to obtain the intra- and interobserver variability. Results. The intra-and interobserver intra-class coefficients (ICC) were evaluated using the classification of Landis&Koch (see table). Preoperative results: Rotation of femoral component in 3D: ICC CTA=0,73; ICC PCA=0,66. Rotation in 2D: ICC PCA=0,75, ICC CTA=0,84. The highest ICC was found for the HKA: ICC>0,98 both 2D and 3D. Postoperative results. All ICC's are in the highest category (‘almost perfect’) except for the intraobserver ICC PCA in 2D which was ‘substantial’. Conclusions and clinical implications. CT-evaluation is invaluable for the preoperative planning of the position of the femoral component, for the evaluation of the rotation of the femoral component and for accurate assessment of the overall knee alignment,. This study demonstrates low intra- and inter- observer variability in the CT measurement of the pre- and postoperative alignment of the knee. To determine the rotation of the femoral component preoperatively there was no advantage for 3D over 2D. Post-operatively the use of the 3D technique has a lower variability with regard to the assessment of the rotation of the femoral component


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 86 - 86
1 Jan 2016
Kamara E Robinson J Hepinstall M Rodriguez J
Full Access

Introduction. Total hip arthroplasty is considered to be one of the most successful orthopaedic interventions. Acetabular component positioning has been shown to affect dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. The safe zones of acetabular component positioning have previously been described by Lewinnek et al. as 5 to 25 degrees of cup version and 30 to 50 degrees of inclination. Callanan et al. later modified the inclination to 30 to 45 degrees. Our aim was to assess whether THA via robotic assisted posterior approach (PA) improves acetabular component positioning compared to fluoroscopic guided anterior approach THA (AA). Methods. Subjects. This study is a matched-pair case-control study using prospectively collected data from THAs done between January 2012 and December 2013. Patients who underwent primary THA using the PA or AA by the senior surgeons (MH and JAR) were included in the study. Ninety-six patients (of 176; 55%) underwent AA and 80 (of 176; 45%) underwent PA THAs. The matching process was performed by an observer blinded to the radiographic outcomes (EK). Patients were matched for sex and BMI +− 8 units. Seventy-nine patients who had AAs were manually matched to 79 patients who had PAs. Surgical Techniques. For the AA THAs, the patient is supine and the approach is performed through a modified smith Peterson approach. Acetabular cup positioning is assessed intraoperatively with fluoroscopy. For the PA THAs, the patient in the lateral position using the posterior approach. Acetabular cup positioning was guided by the MAKO robotic hip system using preoperative CT scans of the involved hip. Radiographic Measurements. The radiographic measurements were done manually using a standardized technique by two observers blinded to the type of arthroplasty performed. Spearman's rank correlation coefficient was used to test user dependent variability. Means were used for final calculations. Statistical Analysis. The average cup inclination and anteversion angles were calculated. Calculation of the number of hips that were in the safe zones of Lewinnek (inclination, 30°–50°; anteversion, 5°–25°) and Callanan (inclination, 30°–45°; anteversion, 5°–25°) regarding inclination, anteversion, and a combination of both were done for both groups. Independent t-tests were performed to compare both groups for sex, BMI, and inclination and anteversion angles. Fisher's exact test was used to compare both groups regarding the number of hips in the safe zones of Lewinnek and Callanan. Relative risk and absolute risk reduction were calculated. Results. There was no significant difference in BMI between the two groups. Intraobserver agreement was found to be .92 and 0.82 for inclination and anteversion, respectively. Compared to fluoroscopic guided THAs, THAs performed with robot assistance were found to be more often in the safe zone of Lewinnek (90% vs. 75%, p=0.02, RR 0.40 [0.19–0.85] p=0.01). This pattern was observed in the zone of Callanan and approached statistical significance (80% vs. 68%, p=0.11, RR 0.64 [0.37–1.10] p=0.11). Conclusion. Compared to fluoroscopic assisted THA, robot assisted THAs are more likely to be within the safe zone of Callanan and Lewinnek


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 570 - 570
1 Dec 2013
Boudt P Piepers I Van Der Straeten C Van Tongel A De Wilde L
Full Access

Background:. The balance between the subscapularis muscle and the infraspinatus/teres minor muscles, often referred to as the rotator cuff ‘force couple’, has been proposed to be critical component for glenohumeral stability. Function of these muscles can be estimated with the evaluation of muscle atrophy. In clinical practice, muscle cross-sectional area (CSA) rather than 3D muscle volume measurement have been used because it is less time consuming. Because combined anthropometric measures of length and width more accurately define the muscular volume it seems logical to study the transversal rotator cuff force couple in the transversal plane an not in the sagittal plane of the body because both parameters can be included. But is it not clear which transversal CSA has the best correlation with muscle volume. Purpose:. To determine the optimal transversal CSA that has the best correlation with muscle volume. Material and Methods:. A total of 30 CT images containing the full scapula were used. Using Mimics® and 3-Matic® the correlation between CSA's and volume has been evaluated. Two methods have been evaluated. The first method was the CSA measured on transversal plane without 3D editing. The second method is a CSA measured on a new defined transversal plane using 3D reconstruction and reslice editing techniques. Results. Both techniques showed a very high inter and intraobserver reliability (ICC for single measures in both techniques > 0.97, p < 0.001). Correlation of the muscle volume/CSA of the subscapularis showed a high correlation in both the non-reconstructed (ρ = 0,699, p = 0,002) and reconstructed technique (ρ = 0,842, p < 0,001). Correlation of the muscle volume/CSA of the infraspinatus/teres minor showed a moderate correlation in the non-reconstructed (ρ = 0,591, p = 0,013) and a high correlation in reconstructed technique (ρ = 0,779, p < 0,001). There is a significant higher correlation with the volume with the reconstructed technique compared to the non-reconstructed technique (ρ = 0.638, p < 0.001 for the conventional transversal section versus ρ = 0.818, p < 0.001 for the resliced section). Conclusion. Muscular volume of the rotator cuff force couple can be quantified using a non-reconstructed CSA, but is significant more accurately quantified by a 3D reconstructed technique. In the future, balance of the force couple in different shoulder pathologies can be quantified with this measurement technique


A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robot assistance. This study was conducted to determine if robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. Twenty knee replacements of ten robot-assisted and another ten conventional operations were performed on ten cadavers. Two experienced surgeons performed the surgery. Both procedures were undertaken by one surgeon on each cadaver. The choice of which was to be done first was randomized. After the implantation of the prosthesis, the mechanical-axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via three-dimensional CT scanning. These variants were then compared with the preoperative planned values. In the robot-assisted surgery, the mechanical-axis deviation ranged from −1.94 to 2.13° (mean: −0.21°), the femoral coronal angle ranged from 88.08 to 90.99° (mean: 89.81°), the tibial coronal angle ranged from 89.01 to 92.36° (mean: 90.42°), the tibial sagittal angle ranged from 81.72 to 86.24° (mean: 83.20°), and the femoral rotational alignment ranged from 0.02 to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the conventional surgery, the mechanical-axis deviation ranged from −3.19 to 3.84°(mean: −0.48°), the femoral coronal angle ranged from 88.36 to 92.29° (mean: 90.50°), the tibial coronal angle ranged from 88.15 to 91.51° (mean: 89.83°), the tibial sagittal angle ranged from 80.06 to 87.34° (mean: 84.50°), and the femoral rotational alignment ranged from 0.32 to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional surgery, there were two cases of outlier outside the range of 3° varus or valgus of the mechanical-axis deviation. The robot-assisted surgery showed significantly superior femoral-rotational-alignment results compared with the conventional surgery (p=0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty in the other variants. All the variants were measured with high intraobserver and interobserver reliability. In conclusion, Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the three-dimensional CT. Especially, better accuracy in femoral rotational alignment was shown in the robot-assisted surgery than in the conventional surgery despite the fact that the surgeons who performed the operation were more experienced and familiar with the conventional surgery than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to the conventional total knee arthroplasty