Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 74 - 74
1 Dec 2020
Köse N Bayrak ÇH Köse AA Sevencan A Toktaş AG Doğan A
Full Access

Orthopaedic and trauma implant related infection remains one of the major complications that negatively impact clinical outcome and significantly increase healthcare expenditure. Hydroxyapatite has been used for many years to increase implant osseointegration. Silver has been introduced into hydroxyapatite as an antimicrobial coating for orthopedic implants. This surface coatings can both increase tissue compatibility and prevent implant-related infections. We examined infection markers and blood silver values, liver and kidney function tests of 30 patients with of three groups of orthopedic implants, external fixators, intramedullary nails and hip replacements, coated with Ag + ion doped CaP based ceramic powder to determine safety and effectiveness of this dual-function coating. During 1 year follow-up, the pin sites were observed at the external fixator group, and wound areas for the proximal femoral nail and hip arthroplasty group at regular intervals. In addition, liver and kidney function tests, infection markers and blood silver values were checked in patients. In the external fixator group, only 4 out of 91 pin sites (%4.39) were infected. The wound areas healed without any problem in patients with proximal femoral nails and hip arthroplasty. There was no side effect suggesting silver toxicity such as systemic toxic side effect or argyria in any patient and blood silver level did not increase. Compared to similar patient groups in the literature, much lower infection rates were obtained (p = 0.001), and implant osseointegration was good. In patients with chronic infection, the implants were applied acutely after removing the primary implant and with simple debridement. Unlike other silver coating methods, silver was trapped in hydroxyapatite crystals in the ionic form, which is released from the coating during the process of osseointegration, thus, the silver was released into the systemic circulation gradually that showed antibacterial activity locally. We conclude that the use of orthopedic implants with a silver ion added calcium phosphate-based special coating is a safe method to prevent the implant-related infection. This work was supported by TUBİTAK Project Number 315S101


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 283 - 283
1 Jul 2014
Post V Wahl P Uckay I Zimmerli W Corvec S Loiez C Ochsner P Moriarty F
Full Access

Summary. Staphylococcus aureus isolates from Fracture fixation device related infections contained fewer isolates that form a strong biofilm in comparison with isolates from Prosthetic joint infections. Both orthopaedic implant related infection groups possessed fnbB and sdrE more frequently than the non-implant related infection groups. Introduction. One of the most common pathogen causing musculoskeletal infections is Staphylococcus aureus. The aim was to characterise S. aureus isolated from these infections and to look for differences between the isolates from orthopaedic implant related infections (OIRI) and those in non-implant related infections (NIRI). The OIRI are further differentiated in those associated with fracture fixation (FFI) devices and those found in prosthetic joint infections (PJI). Methods. Three-hundred and five S. aureus isolates were collected from different Swiss and French hospitals (FFI, n=112; PJI, n=105; NIRI, n=88). The cases of NIRI were composed of 27 osteomyelitis (OM), 23 diabetic foot infections (DFI), 27 soft tissue infections (STI) and 11 postoperative spinal infections (SI). Isolates were tested for their ability to form a biofilm. They were typed by agr (accessory gene regulator) group and genes coding for the 13 most relevant MSCRAMMs, Panton-Valentine leukocidin (PVL), PIA (polysaccharide intercellular adhesin), γ-haemolysin, the five most relevant Staphylococcal enterotoxins (SEA-SEE), exfoliative toxins A and B (ETA and ETB) and toxic shock protein (TST) were screened for by PCR. Results. The majority of the S. aureus isolates were methicillin susceptible (MSSA) with 83.4% for the OIRI and 93.2% for the NIRI. All isolates were able to produce a biofilm. A strong biofilm was produced in 13.8% of the OIRI isolates compared to 10.2% of the NIRI isolates. The difference between the isolates of the PJI versus the FFI was statistically significant (20% vs 8%; p=0.011). All four agr types were present in all groups. agrI predominated in the OIRI (42.4%) as well as in the NIRI (44.4%). Comparing OIRI with NIRI, agrII was present in a higher prevalence in OIRI (30.9% vs 14.8%) and agrIII in a lower incidence (21.2% vs 30.7%). Genes cna, clfA and bbp were exhibited predominantly by isolates from the NIRI, while the fnbB and the sdrE gene were more frequently observed among OIRI. Conclusions. Methicillin susceptible S. aureus (MSSA) was more prevalent than methicillin resistant S. aureus (MRSA) in this collection. Possible trends for the orthopaedic device associated infection groups FFI and PJI could be observed whereby isolates from PJI produced stronger biofilm than isolates from the FFI group. The agr type agrII, the fnbB gene and sdrE gene were more prevalent present in the OIRI compared to the NIRI. In contrast, agrIII, and the bbp gene were more prevalent in the NIRI than in the OIRI


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 19 - 19
1 Nov 2018
Angrisani N Janssen H Kietzmann M Dahlhaus D Warwas D Behrens P Reifenrath J
Full Access

The field of nanoparticle related research for the diagnosis and therapy of diseases evolves rapidly. Magnetic nanoparticles in combination with magnetizable implant materials for the treatment of implant related infections present a possible implementation in orthopedics. Magnetic nanoporous silica nanoparticles (MNPSNPs) were developed and equipped with fluorescent dyes. In vitro/in vivo biocompatibility and in vivo biodistribution were examined to appraise their potential applicability. Cell culture tests with NIH-3T3 and HepG2 cell lines indicated a good in vitro biocompatibility. Ferritic and titanium alloy (control) plates were implanted subcutaneously at the hind legs of Balb/c mice. Immediately after i.v. or s.c. injection of MNPSNPs, the caudal half of the mice was placed between the poles of an electro magnet. Exposure to the electromagnetic field of approx. 1.7 T was maintained for 10 minutes. 10 animals each were euthanized at days 0, 1, 7, 21 or 42, respectively. Quantity of MNPSNPs in liver, spleen, kidney, lung and skin/muscle samples was assessed by fluorescent microscopic methods. MNPSNP existence on the implant surface was also appraised after several steps of detachment. MNPSNPs showed a time-dependent accumulation in the organs after i.v. injection with initial accumulation in the lungs followed by redistribution to liver and spleen. After s.c. injection no systemic distribution but local appearance of MNPSNPs could be found. First histological evaluation showed no pathological changes after i.v. injection. With good in vivo biocompatibility, future focus will be laid on increasing circle life time of MNPSNPs and evaluation in an infection model