To determine the outcome of subtrochanteric fractures treated by intramedullary (IM) nailing and identify causes for implant failure. We performed a retrospective analysis of all subtrochanteric fractures treated by intramedullary nailing in Belfast trauma units between February 2006 and 2009. This subgroup of patients was identified using the Fractures Outcome Research Database (FORD). Demographic data, implant type, operative details, duration of surgery and level of operator were collected and presented. Post-operative X-rays were assessed for accuracy of reduction. One hundred and twenty two (122) patients were identified as having a subtrochanteric fracture treated by IM nailing. There were 79 females and 43 males. Age range was 16 to 93 (mean 78). 95 (78%) cases were performed by training grades and 27 (22%) by consultants. Duration of surgery ranged from 73–129mins (mean 87mins). 47 patients (38.5%) were found to have a suboptimal reduction and 75 patients (61.5%) had an anatomical reduction on immediate post-operative x-ray. One year from surgery 73/122 patients were available for follow up. Of those patients with suboptimal reduction, 13/47 (27.7%) required further surgery. 8 required complete revision with bone grafting, and 5 underwent dynamisation. A further 6 patients had incomplete union. In the anatomical group, 4 patients underwent further surgery (5%). 3 required dynamisation and one had exchange nailing for an infected non-union. 3 patients had incomplete union at last follow up. 5/47 (10.6%) had open reduction in the suboptimal group compared to 25/75 (33.3%) in the anatomical group. Of the 27 cases performed by consultants, 13 (48%) were open reduction, compared to 17/93 (18%) by training grades. This study has shown that inadequate reduction of subtrochanteric fractures, leads to increased rates of non union and ultimately implant failure. We recommend a low threshold for performing open reduction to ensure anatomical reduction is achieved in all cases


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 36 - 36
1 Sep 2012
Ahmad M Obakponovwe O Mokawem M Kanakaris N Giannoudis P
Full Access

Background. The management of non-unions of subtrochanteric femoral fractures with associated implant failure is challenging. This study assessed the outcome of a cohort of patients treated according to the diamond concept. Methods. Between 2005–2010 all patients with subtrochanteric aseptic non-unions presented post implant failure (Gamma Nail breakage) were eligible in the absence of severe systemic pathologies and comorbidities. Demographics, initial fracture pattern, method of stabilisation, mode of failure of metal work, time to revision of fixation, complications, time to union, and functional outcome were recorded over a minimum period of follow-up of 12 months. The revision strategy was based on the “diamond concept;” optimising the mechanical and biological environment (revision of fixation, osteoinduction/BMP-7, osteoconduction/RIA harvested graft, and osteogenicity/concentrate of bone marrow aspirate). Results. Out of 280 nailing procedures 12 (4.3%) cases met the inclusion criteria. A consistent mode of metalwork failure was recorded with initial breakage of the proximal distal locking screw followed by nail breakage at the lag screw level. Biomechanical SEM analysis of the nails revealed no structural damage besides the standard fatigue striation. Varus mal-reduction was present in all cases, with an average of 7.3 degrees (5–11). The average time to screw failure was 4.3 months (2–6) and nail failure was 5.9 months (4–10). All but one of the cases were revised to a 95 degrees blade plate and one to an Affixus nail. Time to union was 6.5 months (5–10). All but one of the cases by 12 months have returned to their preinjury level of mobilisation. Conclusion. Varus mal-reduction must be avoided in the initial stabilisation of subtrochanteric fractures. Proximal distal screw failure is predictive of future fracture non-union and subsequent nail breakage. The diamond concept for optimising mechanics and bone biology is a successful method for managing complex sub-trochanteric non-unions with failed metalwork


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 305 - 305
1 Dec 2013
Fetto J
Full Access

355 non-cemented MOM arthroplasties, of a single surgeon, with a follow up of 3–16 years (avg. 7.5 years) were retrospectively reviewed for evidence of pseudotumor and aseptic mechanical failure. There were 186 with 28 mm heads, 126 with 34 mm heads, 47 with 38 mm heads, from a single manufacturer.

There were 5 revisions of 38 mm heads for atraumatic painful “metalosis” 4–8 years after implantation (10.7%).

There were 4 revisions of 34 mm heads for post-traumatic instability (dislocation) with secondary metalosis 4–7 years after implantation (3.1%)

There were 2 revisions of 28 mm heads for post-traumatic instability (dislocation) with secondary metalosis 6–12 years after implantation (1.1%).

There were 5 patients, all with 38 mm heads, with asymptomatic “psoas bursae” with elevated serum CR and Co levels (1.0–3.0).

All of the failed THR's had acetabular components with lateral tilt <50 degrees (35–50), and anteversion angles <15 degrees (0–15). 2 of the 34 mm and both 28 mm instabilities were the consequence of injuries sustained in motor vehicle accidents. The remaining 2 instabilities with 34 mm implants were the result of mechanical falls.

Particulate debris, whether secondary to polyethylene, ceramic or metal articulations has been well documented as a cause of synovitis and damage to bony and soft tissues adjacent to a THR. This debris appears to be the result of material wear and mechanical failure with use over time. Unlike native articular cartilage, these materials are incapable of self-lubrication. Therefore THR articulations are dependent upon the penetration of ambient synovial fluid to provide lubrication of the replacement surfaces. This study suggests that increase in head diameter may reduce penetration of synovial fluid between the articulating surfaces of a THR, compromising the lubrication of bearing surfaces; thereby contributing to accelerated wear and premature failure of larger MOM arthroplasties.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 7 - 7
1 Jul 2012
Agni N Sellers E Johnson R Gray A
Full Access

The aim of this study was to establish any association between implant cut-out and a Tip Apex Distance (TAD), ≥25mm, in proximal femoral fractures, following closed reduction and stabilisation, with either a Dynamic Hip Screw (DHS) or Intramedullary Hip Screw (IMHS) device. Furthermore, we investigated whether any difference in cut-out rate was related to fracture configuration or implant type.

WE conducted a retrospective review of the full clinical records and radiographs of 65 consecutive patients, who underwent either DHS or IMHS fixation of proximal femoral fractures. The TAD was measured in the standard fashion using the combined measured AP and lateral radiograph distances. Fractures were classified according to the Muller AO classification.

35 patients underwent DHS fixation and 30 patients had IMHS fixation. 5 in each group had a TAD≥25mm. There were no cut-outs in the DHS group and 3 in the IMHS group. 2 of the cut-outs had a TAD≥25mm. The 3 cut-outs in the IMHS group had a fracture classification of 31-A2, 31-A3 and 32-A3.1 respectively. In addition, the fractures were inadequately reduced and fixed into a varus position.

A TAD<25mm would appear to be associated with a lower rate of cut-out. The cut-out rate in the IMHS group was higher than the DHS group. Contributing factors may have included an unstable fracture configuration and inadequate closed fracture reduction at the time of surgery.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 539 - 550
21 Jul 2023
Banducci E Al Muderis M Lu W Bested SR

Aims. Safety concerns surrounding osseointegration are a significant barrier to replacing socket prosthesis as the standard of care following limb amputation. While implanted osseointegrated prostheses traditionally occur in two stages, a one-stage approach has emerged. Currently, there is no existing comparison of the outcomes of these different approaches. To address safety concerns, this study sought to determine whether a one-stage osseointegration procedure is associated with fewer adverse events than the two-staged approach. Methods. A comprehensive electronic search and quantitative data analysis from eligible studies were performed. Inclusion criteria were adults with a limb amputation managed with a one- or two-stage osseointegration procedure with follow-up reporting of complications. Results. A total of 19 studies were included: four one-stage, 14 two-stage, and one article with both one- and two-stage groups. Superficial infection was the most common complication (one-stage: 38% vs two-stage: 52%). There was a notable difference in the incidence of osteomyelitis (one-stage: nil vs two-stage: 10%) and implant failure (one-stage: 1% vs two-stage: 9%). Fracture incidence was equivocal (one-stage: 13% vs two-stage: 12%), and comparison of soft-tissue, stoma, and mechanical related complications was not possible. Conclusion. This review suggests that the one-stage approach is favourable compared to the two-stage, because the incidence of complications was slightly lower in the one-stage cohort, with a pertinent difference in the incidence of osteomyelitis and implant failure. Cite this article: Bone Jt Open 2023;4(7):539–550


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 13 - 13
3 Mar 2023
Rohra S Sinha A Kemp M Rethnam U
Full Access

Background. Dynamic Hip Screw (DHS) is the most frequently used implant in management of intertrochanteric femoral fractures. There is a known statistical relationship between a tip-apex distance (TAD) >25mm and higher rate of implant failure. Our aim was to analyse all DHS procedures performed in our trust from seventeen months and compare their TAD values to the acceptable standard of ≤25mm. Methods. All patients undergoing DHS between April 2020-August 2021 were identified from our theatre system. Additionally, those presenting to hospital with implant failures were included. Patient demographics, date of surgery, fracture classification (AO) and date/mode of failure were recorded. Intraoperative fluoroscopy images were reviewed to calculate TAD, screw location and neck shaft angles by two independent observers. Results. 215 patients were identified, five of which were excluded due to inadequate fluoroscopy. Failure was seen in 3.3% of the cohort (n=7), of which 71.4% had an unacceptable TAD. In total, 21 patients (10%) had TAD >25mm, of whom 12 had superiorly and 15 had posteriorly placed screws. There were no failures in patients with a TAD of <20mm whereas a TAD >30mm had 50% failure rate. Conclusion. This audit reinforces the importance of aiming for a low TAD (preferably <20mm) intraoperatively. It is also desirable to avoid superiorly and significantly posteriorly placed screws. Implications. Complex hip revision surgery in the elderly bears substantial financial implications to the NHS and, more importantly, causes prolonged morbidity to the patient. Adhering to established standards will ensure reduced implant failure and best patient care


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 62 - 62
24 Nov 2023
Rondaan C Maso A Birlutiu RM Fernandez M de Brito VD Salles MJC Junyent JG del Toro MD Hofstätter J Moreno JE Wouthuyzen-Bakker M
Full Access

Aim. The aim of this study was to investigate the clinical relevance of an isolated positive sonication fluid culture (SFC) in patients who underwent revision surgery of a prosthetic joint. We hypothesized that cases with a positive SFC have a higher rate of infection and prosthesis failure during follow-up compared to controls with a negative SFC. Method. This retrospective multicentre observational study was performed within the European Study Group of Implant-Associated Infections (ESGIAI). All patients who underwent revision surgery of a prosthetic joint between 2013 and 2019 and had a minimum follow-up of 1 year were included. Patients with positive tissue cultures or synovial fluid cultures were excluded from the study. Results. 95 cases (positive SFC) and 201 controls (negative SFC) were included. There was no difference in infection and prosthesis failure during follow-up between both groups. When solely analysing patients that were not treated with antibiotics, 16% of the cases had an infection during follow-up versus 5% of the controls (P 0.046). Conclusions. Withholding antimicrobial treatment in patients with an isolated positive SFC is associated with a higher reinfection rate. Antimicrobial treatment should be considered in isolated positive SFC, especially in case of high virulent pathogens


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 14 - 14
10 May 2024
Mooya S Berney M Cleary M Rowan F
Full Access

Introduction. The condition of the soft tissues surrounding an ankle fracture influences timing and treatment of injuries. Conventional treatment used an open approach to facilitate anatomical reduction and rigid internal fixation. Intramedullary devices for fibular fractures provide a safe alternative in patients in which the condition of the soft tissue envelope or the patient's co-morbidities may benefit from a less invasive approach. We compared outcomes for patients treated with open reduction internal fixation (ORIF) with those undergoing treatment with fibular nails (FN). Methods. 13 consecutive patients treated with fibular nails (FN) were compared with 13 age-matched patients that underwent open reduction and internal fixation (ORIF). All patients were followed to union. Study outcomes were time from admission to surgery, length of stay, wound failure, implant failure, revision surgery, OMAS and SF-36. Results. There was no difference in age or sex distribution between groups. There was no difference in OMAS at 1 year (83 ± 9 in FN group; 80± 21 in ORIF group) and SF-36 (94 ± 11 and 90 ± 20). There were 2 implant failures in the ORIF group and none in the FN group. There was one wound failure in the ORIF group and none in the FN group. Patients treated with FN had a shorter time to surgery (1 day ± 24 hours vs 3 days ± 24 hours) and shorter length of stay (1 day ± 24 hours vs 4 days ± 96 hours). Conclusion. FN is a safe method to treat patients with displaced distal fibular fractures that may have a poor soft tissue envelope and risk factors for wound healing. FN reduces the time to surgery and overall length of stay compared with similar patients treated with conventional ORIF


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims. Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. Methods. A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages. Results. Osteolysis next to the telescopic junction was observed in 31/48 segments (65%) lengthened with the STRYDE nail before implant removal compared to 1/91 segment (1%) in the PRECICE cohort. In the STRYDE cohort, osteolysis initially increased, but decreased or resolved in almost all lengthened segments (86%) after implant removal. Implant failure was observed in 9/48 STRYDE (19%) and in 8/92 PRECICE nails (9%). Breakage of the distal locking bolts was found in 5/48 STRYDE nails (10%) compared to none in the PRECICE cohort. Treatment-associated pain was generally recorded as mild and found in 30/48 patients (63%) and 39/92 (42%) in the STRYDE and PRECICE cohorts, respectively. Temporary range of motion (ROM) limitations under distraction were registered in 17/48 (35%) segments treated with the STRYDE and 35/92 segments (38%) treated with the PRECICE nail. Conclusion. Osteolysis and periosteal reaction, implant breakage, and pain during lengthening and consolidation is more likely in patients treated with the STRYDE nail compared to the PRECICE nail. Temporary ROM limitations during lengthening occurred independent of the applied device. Implant-related osseous alterations seem to remodel after implant removal. Cite this article: Bone Joint J 2023;105-B(1):88–96


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 31 - 31
1 Mar 2021
Sun M Buckler N AlNouri M Vaughan M Hilaire TS Sponseller P Smith J Thompson G Howard J El-Hawary R
Full Access

Scoliosis is estimated to occur between 21–64% of patients with cerebral palsy (CP), where a subset of patients develops early onset scoliosis (EOS) before the age of ten. Traditional growth friendly (TGF) surgeries in the context of traditional growing rods have been shown to be effective in treating scoliosis in this population, however significant complication rates are reported. Currently, no studies have been done to examine the effect of novel growth friendly surgeries such as magnetically controlled growing rods (MCGR) on EOS in CP patients. The objective of this study is to compare MCGR with TGF surgeries in this patient population, specifically by evaluating radiographic measurements and risk of unplanned reoperations (UPRORs). Patients with EOS secondary to CP were prospectively identified from an international database, with data retrospectively analyzed. Scoliosis (primary curve), maximum kyphosis, T1-S1 and T1-T12 height were measured pre-operation, immediate post-operation, and at two-years follow-up. The risk and etiology of UPRORs were compared between MCGR and TGF. P < 0.05 was considered statistically significant for all analyses. Of the 120 patients that met inclusion criteria, 86 received TGF (age 7.5 ± 1.8 years; follow-up 7.0 ± 2.9 years) and 34 received MCGR (age 7.1 ± 2.2 years, follow-up 2.8 ± 0.5 years). Compared to TGF, MCGR resulted in significant improvements in maintenance of scoliosis correction (p=0.04). At final follow-up, UPRORs were 24% for MCGR (8/34 patients) and 43% (37/86 patients) for TGF (p=0.05). To minimize the influence of follow-up period, UPRORs within the first two years post-operation were evaluated: MCGR (21%, 7/34 patients) vs. TGF (14%, 12/86 patients; p=0.37). Within the first two years, etiology of UPROR as a percentage of all patients per group were deep infection (5% TGF, 6% MCGR), implant failure/migration (5% TGF, 9% MCGR), dehiscence (2% TGF, 3% MCGR), and superficial infection (1% TGF, 3% MCGR). The most common etiology of UPROR for TGF was deep infection and implant failure/migration and for MCGR was implant failure/migration. For patients with CP, at final follow-up, MCGR had superior maintenance of scoliosis correction; however, there was no difference in risk of UPROR within the first two years post-operatively (21% MCGR, 14% TGF)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 7 - 7
12 Dec 2024
Shah D Shah A
Full Access

Introduction. Instability in ACL deficient knees can lead to medial compartment osteoarthritis. The risk of developing significant OA is 5x higher in knees with ACL deficiency. In associated Varus, there is quicker progression of the medial OA along with a varus thrust exerting strain on the ACL graft. The simultaneous valgus HTO and ACL reconstruction decompresses the medial tibiofemoral joint, corrects the mechanical-axis and reduces strain on the graft. Outcomes for this simultaneous procedure are still unclear in literature and we attempt evaluating its functional outcome. Methods. This Panel study was performed using data from 2019 to 2022 on 21 patients who had ACL insufficiency with Varus or medial OA and underwent a simultaneous Opening-wedge HTO with Arthroscopic ACL reconstruction. The mean follow-up was 2 years. The patients were evaluated with IKDC and Lysholm scores, Lachman test and ROM pre and post-operatively. The HKA was compared pre and post-operatively and the complications were evaluated. The progression of OA was evaluated with serial radiographs post-operatively. Results. There was a significant improvement in lifestyle and knee joint function post-operatively. The mechanical femorotibial angle was corrected from an average of 8.2° Varus to 0.8° Valgus. There was a significant improvement in IKDC and Lysholm scoring (IKDC score improved to 86.20 from 34.48 and the Lysholm score improved to 89 points from 37 points). There was significant improvement in the laxity which was evaluated by Lachman test. One patient had a clinical progression of medial-OA. No patients had non-union, graft or implant failure. Conclusion. Single stage HTO and ACL Reconstruction in patients with medial OA or Varus with ACL insufficiency is an option showing a satisfactory functional and radiological outcome along with activity scores


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 13 - 13
1 Jun 2023
Lu W Oomatia A Al Muderis M
Full Access

Introduction. This study reports on minimum 2 year follow up outcomes on functional and quality of life of patients after undergoing bilateral osseointegration in comparison to traditional socket prosthesis. Materials & Methods. This is a prospective pilot study of 35 patients, consisting of 30 males and 5 females, aged 22–66 (mean 36) years at surgery, with minimum two-year follow-up. Selection criteria were age over 18 years, bilateral amputees who had socket-related problems or were wheelchair-bound with short stumps and non-reconstructable limb pathology. Principle outcome measures included the Questionnaire for persons with a Trans-Femoral Amputation (Q-TFA), Short Form Health Survey 36 (SF-36), Six Minute Walk Test (6MWT), Timed Up and Go (TUG), and K-levels. Adverse events were recorded including infection, revision surgery, fractures, and implant failures. Results. Comparisons were made using differences between the mean pre-operative and mean post-operative values for each outcome measure. Significant improvements in all validated outcome measures were observed. All patient who were wheelchair bound prior to the surgery were able to mobilise post operatively. The occurrence levels of adverse events, including the infection rate and revision rate within this patient cohort, were similar to other established trans-femoral osseointegration studies. Conclusions. These preliminary results indicate that osseointegration surgery is a safe and effective alternative treatment for bilateral amputees experiencing socket-related discomfort. Compared to the suboptimal outcomes of socket prostheses, osseointegration currently provides one of the best chances for any bilateral amputee to walk again and regain the ability to perform daily activities


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 29 - 29
1 Nov 2022
Khan S Kapoor L Kumar V
Full Access

Abstract. Background. Reconstruction following resection of sarcomas of the upper extremity with methods described in the prevalent literature may not be possible in few selected cases. We describe Surgical Phocomelia or Phoco-reduction as a method of limb salvage in such cases of extensive sarcomas of the upper limb with its functional and oncological outcomes. Methods. Evaluation of functional and oncological outcomes was performed for 11 patients who underwent surgical phocomelia or phocoreduction for extensive sarcomas of the upper limb between 2010 and 2019. Results. Mean follow-up period in the study was27.8 months. Five patients required a segmental resection including the entire humerus while 6 patients underwent segmental resection around the elbow with a mean resection length of 21.5 cm. Mean MSTS 93 score was 22 depicting a good functional outcome. Mean hand grip strength on the operated side was 62% of the contralateral side with preservation of useful hand function. Mean time to humero-ulnar union was 6.7 months. Radial nerve palsy and implant failure occurred in 1 patient each. No patient developed local recurrence while 3 patients died of metastasis. Conclusion. Surgical phocomelia is a prudent alternative to severely incapacitating amputations in situations where other reconstruction methods are not feasible


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 83 - 83
10 Feb 2023
Lee H Lewis D Balogh Z
Full Access

Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of a readily available cost-effective medial implant option. A retrospective analysis from January 2014 to June 2022 was performed on DFF (primary or revision) managed with supplemental medial plating with a Large Fragment Locking Compression Plate (LCP) T-Plate (~$240 AUD) via a medial sub-vastus approach. The T-plate was contoured and placed superior to the medial condyle. A combination of 4.5mm cortical, 5mm locking and/or 6.5mm cancellous screws were used, with oblique screw trajectories towards the distal lateral cortex of the lateral condyle. All extra-articular fractures and revision fixation cases were allowed to weight bear immediately. The primary outcome was union rate. This technique was utilised on sixteen patients; 3 acute, 13 revisions; mean age 52 years (range 16-85), 81% male, 5 open fractures. The union rate was 100%, with a median time to union of 29 weeks (IQR 18-46). The mean follow-up was 15 months. There were two complications: a deep infection requiring two debridements and a prominent screw requiring removal. The mean range of motion was 1–108. o. . Supplemental medial plating of DFF with a Large Fragment LCP T-Plate is a feasible, safe, and economical option for both acute fixation and revisions. Further validation on a larger scale is warranted, along with considerations to developing a specific implant in line with these principles


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 54 - 54
24 Nov 2023
Buijs M Haidari S Ijpma F Hietbrink F Govaert G
Full Access

Aim. By gaining insight into the Quality of Life (QoL) status and occurrence of complications, critical facets in the care for patients with Fracture-Related Infection (FRI) can be mitigated and measures can be taken to improve their outcome. Therefore, the aims of this study were to 1) determine the QoL in FRI patients in comparison to non-FRI patients and 2) describe the occurrence of complications in both FRI and non-FRI patients. Method. An ambidirectional cohort study was conducted in a level-1 trauma centre between January 1st 2016 and November 1st 2021. All patients who underwent surgical stabilisation of a long bone fracture were eligible for inclusion. Patients with an Injury Severity Score (ISS) ≥16 or incomplete follow-up were excluded. QoL was assessed through the use of five-level EuroQol five-dimension (EQ-5D-5L) questionnaires twelve months post-injury. Results. A total of 134 patients were included, of whom 38 (28%) FRI patients and 96 (72%) non-FRI patients. In comparison to non-FRI patients, FRI patients scored significantly worse on the QoL assessment regarding the index value (p=0.012) and the domains mobility (p<0.001), usual activities (p=0.010) and pain/discomfort (p=0.009). During the median follow-up of 14.5 months (interquartile range (IQR) 9.5–26.5), 25 FRI patients developed a total of 49 distinctive complications besides FRI. The complications nonunion (18%, n=9/49), infection other than FRI (e.g. line infection, urinary tract infection, pneumonia) (18%, n=9/49) and implant failure (14%, n=7/49) were the most frequently described in the FRI group. Conclusions. Patients who suffered from an FRI have a decreased QoL in comparison to those without an FRI. Moreover, patients with an FRI have a higher rate of additional complications. These findings can help in patient counselling regarding the potential physical and mental consequences of having a complicated course of recovery due to an infection


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 26 - 26
10 Feb 2023
Chavan A Hoellwarth J Tetsworth K Lu W Oomatia A Alam S Vrazas E Al Muderis M
Full Access

Traditional socket prosthesis (TSP) rehabilitation for amputees is associated with substantial dissatisfaction due to poor mobility and pain from soft tissue squeezing. Osseointegration (OI), eliminates skin compression and prosthesis fit issues, providing superior mobility and quality of life (QOL) for most amputees. The potential for OI to benefit patients with exceptionally poor mobility is understudied. To address this knowledge gap, this project investigated the mobility and QOL changes. A retrospective review was performed to identify transfemoral amputees who presented with wheelchair-bound mobility (K0) and had at least five years of post-osseointegration follow-up. Outcome measures included changes in mobility (K-level, daily prosthesis wear hours, Timed Up and Go (TUG), 6 minute walk test (6MWT)) and QOL (Questionnaire for persons with a Transfemoral Amputation (QTFA); Short Form Health Survey 36 (SF36). Adverse events recorded included debridement for infection, implant revision surgery, fractures, and implant failures. 9 patients with mean age 48.2±7.7 (range 34-59) years were included. The proportion of patients achieving K-level >2 improved from 0/9=0% to [9/9=100%], p<0.001. The 6MWT improved from 0±0 to 320.65±57 meters (p<0.001). The TUG improved from incapable to 10.68±2.7 seconds (p<0.001). Statistically significant QOL metrics included QTFA global score (33.33±31 vs 68.52±21, p=0.039), SF36 physical component score (30.03±6.3 vs 42.34±12, p=0.023) and the SF36 mental component score (47.89±8.8 vs 51.95±10.4, p=0.332). Six patients required operative intervention to address complications. Five developed infections: three had debridement, and 2 required implant removal and reimplantation. Osseointegration does confer significant sustained mobility and quality of life improvement for wheelchair bound transfemoral amputees. All 9 K0 patients had statistically improved mobility and QOL after osseointegrated reconstruction. This supports osseointegration as an effective rapid and long-term rehabilitation alternative for patients who have the neurologic and muscular capacity to walk but are unable due to issues related to their TSP


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 4 - 4
1 Nov 2022
Adapa A Shetty S Kumar A Pai S
Full Access

Abstract. Background. Fractures Proximal humerus account for nearly 10 % of geriatric fractures. The treatment options varies. There is no consensus regarding the optimal treatment, with almost all modalities giving functionally poor outcomes. Hence literature recommends conservative management over surgical options. MULTILOC nail with its design seems to be a promising tool in treating these fractures. We hereby report our early experience in the treatment of 37 elderly patients. Objectives. To evaluate the radiological outcome with regards to union, collapse, screw back out/cut through, implant failures, Greater tuberosity migration. To evaluate the functional outcome at the end of 6 months using Constant score. Study Design & Methods. All patients aged >65 years who underwent surgery for 3,4-part fracture proximal humerus using the MULTILOC nail were included in the study after consent. Pre – existing rotator cuff disease were excluded. Within the time frame, a total of 39 patients underwent the said surgery. 2 patients were lost to follow up. All the measurements were taken at the end of 6 months and results tabulated and analysed. Results. Union was achieved in all the 37 patients. There were no varus collapse or screw backout/cut through seen in any of the patients. There was Greater tuberosity migration in 1 patient who underwent revision surgery at 6 weeks. All the patients got a minimum of 70 degrees of abduction and forward flexion. We had 29 excellent, 6 good, 2 fair and none poor results as per Constant scoring system. Study done in Tejasvini Hospital & SSIOT Mangaluru India


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 19 - 19
1 Oct 2022
Schenk HM Sebillotte M Lomas J Taylor A Benavent E Murillo O Fernandez-Sampedro M Huotari K Aboltins C Trebse R Soriano A Wouthuyzen-Bakker M
Full Access

Aim. Patients with late acute periprosthetic joint infections (PJI) and treated with surgical debridement have a high failure rate. Previous studies have shown that rheumatoid arthritis (RA) is an independent risk factor for treatment failure. We conducted a case-control study to identify predictors for failure in late acute PJI treatment in RA patients. We hypothesize that patients with RA have a higher failure rate compared to controls due to the use of immunosuppressive drugs. Method. Data of an international multicenter retrospective observational study was used. Late acute PJI was defined as a sudden onset of symptoms and signs of a PJI, more than 3 months after implantation. Failure of treatment was defined as persistent signs of infection, relapse with the same or reinfection with a different micro-organism, need for prosthesis removal or death. Cases with RA were matched with cases without RA based on the affected joint. A Cox survival analyses, stratified for RA, was used to calculate hazard ratio's (HR) for failure. Subgroup analyses were used to explore other predictors for treatment failure in RA patients. Results. A total of 40 patients with RA and 80 controls without RA were included. Treatment failure occurred in 65% patients with RA compared to 45% for controls (p= .052). 68% of patients with RA used immunosuppressive drugs at time of PJI diagnosis. The use or continuation of immunosuppressive drugs in PJI was not associated with a higher failure rate; neither were the duration of symptoms and causative microorganism. The time between implantation of the prosthetic joint and diagnosis of infection was longer in RA patients: median 110 (IQR 41-171) vs 29 months (IQR 7.5–101.25). Exchange of mobile components was associated with a lower risk of treatment failure (HR 0.489, 95% CI 0.242–0.989, p-value .047). Conclusions. The use of immunosuppressive drugs does not seem to be associated with a higher failure rate in patients with RA. Mobile exchange in RA patients is associated with a lower risk of failure. This might be due to the significantly older age of the prosthesis in RA patients. Future studies are needed to explore these associations and its underlying pathogenesis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 66 - 66
1 Dec 2022
Martin R Matovinovic K Schneider P
Full Access

Ligament reconstruction following multi-ligamentous knee injuries involves graft fixation in bone tunnels using interference screws (IS) or cortical suspensory systems. Risks of IS fixation include graft laceration, cortical fractures, prominent hardware, and inability to adjust tensioning once secured. Closed loop suspensory (CLS) fixation offers an alternative with fewer graft failures and improved graft-to-tunnel incorporation. However, graft tensioning cannot be modified to accommodate errors in tunnel length evaluation. Adjustable loop suspensory (ALS) devices (i.e., Smith & Nephew Ultrabutton) address these concerns and also offer the ability to sequentially tighten each graft, as needed. However, ALS devices may lead to increased graft displacement compared to CLS devices. Therefore, this study aims to report outcomes in a large clinical cohort of patients using both IS and CLS fixation. A retrospective review of radiographic, clinical, and patient-reported outcomes following ligament reconstruction from a Level 1 trauma centre was completed. Eligible patients were identified via electronic medical records using ICD-10 codes. Inclusion criteria were patients 18 years or older undergoing ACL, PCL, MCL, and/or LCL reconstruction between January 2018 and 2020 using IS and/or CLS fixation, with a minimum of six-month post-operative follow-up. Exclusion criteria were follow-up less than six months, incomplete radiographic imaging, and age less than 18 years. Knee dislocations (KD) were classified using the Schenck Classification. The primary outcome measure was implant removal rate. Secondary outcomes were revision surgery rate, deep infection rate, radiographic fixation failure rate, radiographic malposition, Lysholm and Tegner scores, clinical graft failure, and radiographic graft failure. Radiographic malposition was defined as implants over 5 mm off bone or intraosseous deployment of the suspensory fixation device. Clinical graft failure was defined as a grade II or greater Lachman, posterior drawer, varus opening at 20° of knee flexion, and/or valgus opening at 20° of knee flexion. Radiographic failure was defined when over 5 mm, 3.2 mm, and/or 2.7 mm of side-to-side difference occurred using PCL gravity stress views, valgus stress views, and/or varus stress views, respectively. Descriptive statistics were used. Sixty-three consecutive patients (mean age = 41 years, range = 19-58) were included. A total of 266 CLS fixation with Ultrabuttons and 135 IS were used. Mean follow-up duration was 383 days. Most injuries were KD type II and III. Graft revision surgery rate was 1.5%. Intraosseous deployment occurred in 6.2% and 17% had implants secured in soft tissue, rather than on bone. However, the implant removal rate was only 6.2%. Radiographic PCL gravity stress views demonstrated an average of 1.2 mm of side-to-side difference with 6.2% meeting criteria for radiographic failure. A single patient met radiographic failure criteria for collateral grafts. Mean Lysholm and Tegner scores were 87.3 and 4.4, respectively, with follow-up beyond one year. Both IS and CLS fixation demonstrate an extremely low revision surgery rate, a high rate of implant retention, excellent radiographic stability, and satisfactory patient-reported outcome scores. Incorrect implant deployment was seen in a total of 17% of patients, yet none required implant removal. A single patient required graft revision due to implant failure


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 1 - 1
1 Dec 2021
Puetzler J Moellenbeck B Gosheger G Schmidt-Braekliing T Schwarze J Ackmann T Theil C
Full Access

Aim. Due to medical and organizational factors, it occurs in everyday practice that spacers are left in place longer than originally planned during a two-stage prosthesis exchange in the case of prosthetic joint infections. Patients are severely restricted in their mobility and, after initial antibiotic administration, the spacer itself only acts as a foreign body. The aim of this study is to analyze whether the duration of the spacer in situ has an influence on the long-term success of treatment and mortality. Method. We retrospectively studied all 204 two-stage prosthesis replacements of the hip and knee from 2012 to 2016 with a minimum follow-up of two years at an arthroplasty center with 3 main surgeons. The duration of the spacer interval was divided into two groups. Patients replanted within ten weeks (as is standard in multiple algorithms) after systemic antibiotic treatment were assigned to the ‘Regular Spacer Interval (< 70 days)’ group. If the spacer interval was longer, they were assigned to the ‘Long Spacer Interval (≥ 70 days)’ group. Results. Patients were on average 67.69 years old (SD 12.3). The mean duration of the spacer-interval was 100.9 days (range: 423.0; SD, 60.0). In 62 patients reimplantation could be performed within 70 days after explantation, in 142 patients this took longer (max. 438 days). In 26 patients, the spacer had to be changed at least once during this period (11 patients in the hip group, and 15 patients in the knee group). In the remaining cases, other medical or organizational reasons delayed replantation. Both groups were comparable concerning Charlson Comorbity Index, age, number of previous surgeries and laboratory infection markers. There was no statistically significant influence of the duration of the spacer interval on the infection free survival (n=204, p=0.32). There was also no influence on mortality (n=204, p=0.35) and aseptic implant failure (n=204, p=0.15). Conclusions. The timely replantation of a knee or hip prosthesis seems to be reasonable in general because the patients are strongly limited in their mobility and daily activities by the spacer. However, there does not seem to be a negative influence on infection eradication and survival due to a long spacer interval