Advertisement for orthosearch.org.uk
Results 1 - 20 of 359
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 19 - 19
1 Jul 2022
Sweed T Boutefnouchet T Lim Z Amerasekera S Choudhary S Ashraf T
Full Access

Abstract. Introduction. There are several imaging-based measurements for patello-femoral height. Available methods rely predominantly on sagittal images. The latter can be misleading with sagittal oblique slices and when the patella is tilted and/or chronically subluxed. In this study we describe a simple method of patellar height measurement using axial MRI overlap. Materials and methods. A retrospective observational analysis of 97 knees from 251 patients was conducted. Cases were selected following the exclusion of scans with fractures, massive effusion, patello-femoral pathology. Axial patello-trochlear overlap (APTO) was measured on the axial MRI images as follows: (1) Patellar length (P): expressed as the number of axial images showing patellar articular surface (2) Trochlear overlap (T): the number of axial images showing overlap between patellar articular surface and articular surface of lateral trochlea. APTO is the ratio T/P. All measurements were carried out independently and on two separate occasions by 6 raters. As a control conventional patello-trochlear index were measured for all patients by a senior musculoskeletal radiologist. Results. The mean APTO value was 36.7 (range 14.2 to 66.6; SD 11.4). There was a positive correlation with patello-trochlear index (Pearson correlation coefficient: 0.76, P < 0.001). Intra-observer reliability was good (ICC: 0.66 95 CI 0.54, 0.76, P < 0.001). Inter-observer reliability was fair (ICC: 0.51, 95 CI 0.41, 0.6, P < 0.001). Conclusion. In the present proof of concept study APTO was a reliable measurement of patellar height and correlated with patella-trochlear indices. The method described can prove valuable in overcoming issues with sagittal image measurements


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 43 - 43
7 Aug 2023
Lewis A Bucknall K Davies A Evans A Jones L Triscott J Hutchison A
Full Access

Abstract. Introduction. A lipohaemarthrosis seen on Horizontal beam lateral X-ray in acute knee injury is often considered predictive of an intra-articular fracture requiring further urgent imaging. Methodology. We retrospectively searched a five-year X-ray database for the term “lipohaemarthrosis”. We excluded cases if the report concluded “no lipohaemarthrosis” or “lipohaemarthrosis” AND “fracture”. All remaining cases were reviewed by an Orthopaedic Consultant with a special interest in knee injuries (AD) blinded to the report. X-rays were excluded if a fracture was seen, established osteoarthritic change was present, a pre-existing arthroplasty present or no lipohaemarthrosis present. Remaining cases were then studied for any subsequent Radiological or Orthopaedic surgical procedures. Results. 136 cases were identified and reviewed by an Orthopaedic Consultant. 31 were excluded for no lipohaemarthrosis (n= 11), for degenerative change (n=9), for fracture (n=4), for existing arthroplasty (n=4) and for data errors (n=3). The remaining 105 patients had a mean age of 32, and range 5–90 years. 66 patients underwent further imaging in the form of MRI scan (n=47), CT Scan (n=9) repeat x-rays (n=9) and ultrasound (n=1). 27 fractures were identified. Surgery was performed in 12 cases (11%). Two (2%) urgently (One ACL reconstruction plus meniscus repair, one for ORIF of tibial plateau fracture). Ten (10%) had elective surgery (6 for ACL reconstruction, 2 for ACL reconstruction plus meniscus repair, 2 for loose body removal. Conclusion. The presence of a lipohaemarthrosis on x-ray following acute knee injury was a poor predictor of intra-articular fracture (26%) or need for urgent surgery (2%)


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims. The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). Methods. A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years. Results. The BCR-TKA demonstrated a kinematic pattern comparable to the natural knee’s screw-home mechanism in the step-up task. In the lunge task, the medial CP of the BCR-TKA was more anterior in the early flexion phase, while laterally the CP was more posterior during the entire movement cycle. The BCR-TKA group showed higher tibial migration. No differences were found for the clinical and functional outcomes. Conclusion. The BCR-TKA shows a different kinematic pattern in early flexion/late extension compared to the CR-TKA. The difference between both implants is mostly visible in the flexion phase in which the anterior cruciate ligament is effective; however, both designs fail to fully replicate the motion of a natural knee. The higher migration of the BCR-TKA was concerning and highlights the importance of longer follow-up. Cite this article: Bone Joint J 2023;105-B(1):35–46


Bone & Joint Open
Vol. 5, Issue 2 | Pages 101 - 108
6 Feb 2024
Jang SJ Kunze KN Casey JC Steele JR Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Aims. Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort. Methods. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length. Results. The algorithm measured 1,078 radiographs at a rate of 12.6 s/image (2,156 unique measurements in 3.8 hours). There was no significant difference or bias between reader and algorithm measurements for the FMAA (p = 0.130 to 0.563). The FMAA was 6.3° (SD 1.0°; 25% outside range of 5.0° (SD 2.0°)) using definition one and 4.6° (SD 1.3°; 13% outside range of 5.0° (SD 2.0°)) using definition two. Differences between males and females were observed using definition two (males more valgus; p < 0.001). Conclusion. We developed a rapid and accurate DL tool to quantify the FMAA. Considerable variation with different measurement approaches for the FMAA supports that patient-specific anatomy and surgeon-dependent technique must be accounted for when correcting for the FMAA using an intramedullary guide. The angle between the mechanical and anatomical axes of the femur fell outside the range of 5.0° (SD 2.0°) for nearly a quarter of patients. Cite this article: Bone Jt Open 2024;5(2):101–108


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 69 - 69
1 Jul 2022
Roebuck M Jamal J Wong P Lane B Wood A Bou-Gharios G Frostick S Santini A
Full Access

Abstract. Introduction. Articular cartilage degradation is a defining feature of osteoarthritis. Synovium is a reactive tissue with synovial villae, neoangiogenesis and intimal hyperplasia common to many joint pathologies. The consequences of cartilage debris in osteoarthritis impacting the synovial intima is not well understood. We analysed the immunohistology of synovium from 16 patients with osteoarthritis and 17 patients undergoing knee surgery for non-arthritic pathologies. This data was integrated with imaging and functional scores to correlate synovitis in osteoarthritis. Methodology. Formalin-fixed paraffin embedded synovial biopsy sections were cut in serial sequence and processed for routine staining (H&E or CD3, CD68, CD20, Vimentin, vWF and PCNA IHC) using standardised Dako monoclonal mouse anti-human antibodies. Digital images scanned at x20 were evaluated for fragments of cartilage and aggregates of inflammatory cells. Clinical data (gender, BMI, KL grade, WOMAC & SF-12 scores) was aligned with histopathological data. Results. Cartilage fragments were seen in the synovial intimal layer from end-stage osteoarthritis especially those with BMI<30kg/m2. Macrophages, T-cells and B-cells were identified surrounding cartilage inclusions. Inflammatory aggregates of T-cells, B-cells and macrophages were located peri-cartilage in the intima and peri-vascular in the sub-intimal layer of the synovium. Worse synovitis and function scores were significantly associated with both cartilage inclusions and inflammatory aggregates. X-ray features linked to longer duration of symptoms were associated with inflammatory aggregates. Conclusion. The histological features of the synovium clearly reflect deteriorating joint structures and compromised clinical function


Bone & Joint Open
Vol. 3, Issue 10 | Pages 767 - 776
5 Oct 2022
Jang SJ Kunze KN Brilliant ZR Henson M Mayman DJ Jerabek SA Vigdorchik JM Sculco PK

Aims. Accurate identification of the ankle joint centre is critical for estimating tibial coronal alignment in total knee arthroplasty (TKA). The purpose of the current study was to leverage artificial intelligence (AI) to determine the accuracy and effect of using different radiological anatomical landmarks to quantify mechanical alignment in relation to a traditionally defined radiological ankle centre. Methods. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A sub-cohort of 250 radiographs were annotated for landmarks relevant to knee alignment and used to train a deep learning (U-Net) workflow for angle calculation on the entire database. The radiological ankle centre was defined as the midpoint of the superior talus edge/tibial plafond. Knee alignment (hip-knee-ankle angle) was compared against 1) midpoint of the most prominent malleoli points, 2) midpoint of the soft-tissue overlying malleoli, and 3) midpoint of the soft-tissue sulcus above the malleoli. Results. A total of 932 bilateral full-limb radiographs (1,864 knees) were measured at a rate of 20.63 seconds/image. The knee alignment using the radiological ankle centre was accurate against ground truth radiologist measurements (inter-class correlation coefficient (ICC) = 0.99 (0.98 to 0.99)). Compared to the radiological ankle centre, the mean midpoint of the malleoli was 2.3 mm (SD 1.3) lateral and 5.2 mm (SD 2.4) distal, shifting alignment by 0.34. o. (SD 2.4. o. ) valgus, whereas the midpoint of the soft-tissue sulcus was 4.69 mm (SD 3.55) lateral and 32.4 mm (SD 12.4) proximal, shifting alignment by 0.65. o. (SD 0.55. o. ) valgus. On the intermalleolar line, measuring a point at 46% (SD 2%) of the intermalleolar width from the medial malleoli (2.38 mm medial adjustment from midpoint) resulted in knee alignment identical to using the radiological ankle centre. Conclusion. The current study leveraged AI to create a consistent and objective model that can estimate patient-specific adjustments necessary for optimal landmark usage in extramedullary and computer-guided navigation for tibial coronal alignment to match radiological planning. Cite this article: Bone Jt Open 2022;3(10):767–776


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 34 - 34
7 Aug 2023
Afzal I Radha S Mitchell P
Full Access

Abstract. Multidisciplinary team (MDT) meetings in orthopaedic surgery are evolving. The goals include patient optimisation, surgical planning and discharge arrangements, individually on a patient specific basis. In line with British Association Surgery of the Knee and GIRFT guidelines, we report our regional experience on the implementation and evolution of our regional Revision Knee Arthroplasty MDT. We undertook a retrospective review of the process, cases discussed and quality assurance conducted in the weekly MDT. Since implementation of the MDT meeting in January 2019, 550 patients with painful joint replacements have been discussed. In May 2021, we formalised our ‘terms of reference’ and ‘standard operating procedures’ which are adhered to by the consultants operating within the network, all of whom attend the meeting. A proforma has been developed and is completed for all cases capturing all pertinent information. All cases are graded according to R1, R2, or R3 complexity scale. Since its inception, the MDT has looked at all post-operative imaging, we now describe a new classification system for grading the appearances. Confirmation of the pre-operative plan and actual surgical intervention is reviewed and audited. In addition, confirmation of indication of revision at the time of operation is reviewed and validated for accuracy with benefits to the unit, individual surgeon and the NJR. In conclusion, the implementation of the revision MDT facilitating pre-operative revision arthroplasty discussion and post-operative quality assurance processes enable surgeons to educate, reflect on their practice and ensure that the highest standards of care are being provided


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 58 - 58
7 Aug 2023
Saghir R Watson K Martin A Cohen A Newman J Rajput V
Full Access

Abstract. Introduction. Knee arthroscopy can be used for ligamentous repair, reconstruction and to reduce burden of infection. Understanding and feeling confident with knee arthroscopy is therefore a highly important skillset for the orthopaedic surgeon. However, with limited training or experience, furthered by reduced practical education due to COVID-19, this skill can be under-developed amongst trainee surgeons. Methods. At a single institution, ten junior doctors (FY1 to CT2), were recruited as a part of a five, two-hour session, training programme utilising the Simbionix® ARTHRO Mentor knee arthroscopy simulator, supplemented alongside educational guidance with a consultant orthopaedic knee surgeon. All students had minimal to no levels of prior arthroscopic experience. Exercises completed included maintaining steadiness, image centering and orientation, probe triangulation, arthroscopic knee examination, removal of loose bodies, and meniscectomy. Pre and post-experience questionnaires and quantitative repeat analysis on simulation exercises were undertaken to identify levels of improvement. Results. Comparing pre and post-experience questionnaires significant improvements in levels of confidence were noted in the following domains: naming arthroscopic instruments, port positioning and insertion, recognising normal anatomy arthroscopically, holding and using arthroscopic instruments and assisting in a live theatre setting (p<0.05). Significant improvements were noted in time taken to complete, distance covered in metres and roughness of instruments used on the simulated exercises on repeat performance (p<0.05). Conclusion. With only five sessions under senior guidance, using a simulator such as the ARTHRO Mentor, significant improvements in both levels of confidence and skill can be developed even among individuals with no prior experience


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 39 - 39
7 Aug 2023
Hainsworth L Lankester B
Full Access

Abstract. Introduction. Isolated patellofemoral osteoarthritis accounts for 10% of knee osteoarthritis. Many of these will not require arthroplasty solutions, but for those who are sufficiently symptomatic, patellofemoral joint (PFJ) replacement has been shown to be an effective procedure. The National Joint Registry (NJR) has shown a higher revision rate for this operation, particularly in younger patients (males <55 years 13.3% failure at 5 years, females 9.6%). The aim of this study is to report on the medium-term outcome of the Avon patellofemoral joint arthroplasty in patients under 55 from a non-design centre. There is no other published case series on this young patient cohort. Methodology. 50 Avon PFJ replacements (Stryker, Kalamazoo USA) were undertaken in 46 patients under 55 years old (range 35 – 54, mean 48.8) between 2010 and 2022 for end-stage isolated PFJ arthritis shown on Xray and MRI scan. The outcome measure was all-cause revision rate. This was assessed by review of clinical notes, imaging and NJR data. Results. The mean follow up was 5.8 years (range 6 months to 12.9 years). Only one patient had a revision procedure (for progressive osteoarthritis) which was 3 years after the primary procedure. This patient has had no further surgery. The implant survival rate was 97.2% at 5 years and 97.2% at 10 years. Conclusion. This study shows that patellofemoral joint replacement with the Avon prosthesis can give a satisfactory revision rate in the medium term in patients under 55 if carefully selected


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 82 - 82
7 Aug 2023
Jones R Phillips J Panteli M
Full Access

Abstract. Introduction. Total joint arthroplasty (TJA) is one of the commonest and most successful orthopaedic procedures, used for the management of end-stage arthritis. With the recent introduction of robotic assisted joint replacement, Computed Tomography (CT) has become part of required pre-operative planning. The aim of this study is to quantify and characterise incidental CT findings, their clinical significance, and their effect on planned joint arthroplasty. Methodology. All consecutive patients undergoing an elective TJR (hip or knee arthroplasty) were retrospectively identified, over a 3-year period (December 2019 and December 2022). Data documented and analysed included patient demographics, type of joint arthroplasty, CT findings, their clinical significance, as well as potential delays to the planned arthroplasty because of these findings and subsequent further investigation. Results. A total of 624 patients (637 studies, 323 (51.8%) female, 301 (48.2%) male) were identified of which 163 (25.6%) showed incidental findings within the long bones or pelvis. Of these 52 (8.2%) were significant, potentially requiring further management, 32 (5.0%) represented potential malignancy and 4 (0.6%) resulted in a new cancer diagnosis. Conclusion. It is not currently national standard practice to report planning CT imaging as it is deemed an unnecessary expense and burden on radiology services. Within the study cohort 52 (8.2%) of patients had a significant incidental finding that required further investigation or management and 4 (0.6%) had a previously undiagnosed malignancy. In order to avoid the inevitability of a missed malignancy on a planning CT, we must advocate for formal reports in all cases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 46 - 46
7 Aug 2023
Rahman A Heath D Mellon S Murray D
Full Access

Abstract. Introduction. In cementless UKR, early post-operative tibial fractures are 7x more common in very small tibias. A smaller keel has been shown to reduce this fracture risk, but its effect on fixation is unassessed. This mechanical study assesses the effect of keel interference and size on sagittal micromotion of the tibial component in physiological loading positions. Method. A high-resolution Digital Image Correlation setup was developed and validated to an accuracy of 50 micrometres. Variants of tibial components were 3D-printed: standard, no-interference, no-keel, and a new small keel. Components were implanted into bone-analogue foam which was machined to a CT-reconstructed small tibia, using surgical technique. Tibias were loaded to 200N in physiological loading positions: 8mm (step-up) and 15mm (lunge) posterior to midpoint, and micromotion was assessed. Results. In all tests, anterior lift-off was the largest micromotion observed. In ‘step-up’, a standard keel moved more than the no-interference and no-keel variants (340μm-vs-63μm-vs-30μm, p=0.002). In ‘lunge’ loading, the no-interference and no-keel variants moved more than the standard (826μm-vs-1003μm-vs-521μm, p=0.039). The small keel experienced less micromotion in ‘step-up’ (245μm-vs-340μm p=0.233, overall p=0.009) and ‘lunge’ (378μm-vs-521μm p=0.265, overall p=0.006) than the standard keel. Conclusion. The keel protects against large tibial micromotion during lunge movement. Counterintuitively, interference increases micromotion during step-up movement, likely due to implant pivoting around the bone-keel interface. Results suggest patients should be advised against lunge movements early post-operatively. The new smaller keel fixes similarly or better than the standard keel, making it viable for replacing the standard keel to potentially reduce fracture risk


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 37 - 37
7 Aug 2023
Mudiganty S Jayadev C Carrington R Miles J Donaldson J Mcculloch R
Full Access

Abstract. Introduction. Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR. Methodology. We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed. Results. Achondroplasia was the most common skeletal dysplasia (8), followed by Chondrodysplasia punctata (7) and Spondyloepiphyseal dysplasia (5). There were fourteen men and eight women with mean age of 51 years (28 to 73). The average height of patients was 1.4 metres (1.16–1.75) and the mean weight was 64.8 Kg (34.3–100). The mean follow up duration was 68.32 months (1–161). Three patients died during follow up. Custom implants were required in twelve patients (38.71%). Custom jigs were utilised in six patients and two patients underwent robotic assisted surgery. Hinged TKR was used in seventeen patients (54.84%), posterior stabilised TKR in nine patients (29.03%), and cruciate retaining TKR in five patients (16.13%). One patient underwent a patella resurfacing for persistent anterior knee pain and another had an intra-operative medial tibial plateau fracture which was managed with fixation. No revisions occurred during the follow up period. Conclusion. Despite the technical challenges and complexity of TKR within this unique patient group, we demonstrate good implant survivorship during the study period. Cross sectional imaging is recommended preoperatively for precise planning and templating


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 89 - 89
1 Jul 2022
Rajput V Iqbal S Salim M Anand S
Full Access

Abstract. Introduction. Fractures of the articular surface of the patella or the lateral femoral condyle usually occur following acute dislocation of the patella. This study looked at the radiological and functional outcomes of fixation of osteochondral fractures. Methods. Twenty-nine patients (18 male, 11 female) sustained osteochondral fractures of the knee following patellar dislocation. All patients had detailed radiographic imaging and MRI scan of the knee preoperatively. An arthroscopic assessment was done, followed by fixation using bio-absorbable pins or headless screws either arthroscopically or mini-open arthrotomy. VMO plication or MPFL repair were done if necessary. MRI scan was done at follow-up to assess for healing of the fixed fragment prior to patient discharge. Results. The mean age of the patients was 21 yrs (9–74), 11 had osteochondral fracture of the patella (38%), while 18 were from the lateral femoral condyle (62%). 13 patients needed additional VMO plication. Mean follow up period was 7.7 years (1 to 12 years). As per Tegner activity scale, all patients returned to their pre-injury activity level (Mean score 7) and sports. None of the patients had a further episode of patellar dislocation. Mean postoperative IKDC score was 86.5 (SD 17.3), Kujala was 91.1(SD 15.5) and Tegner- lysholm was 88.7 (SD 14.4). All patients had statistically significant (p < 0.05) improvement. Post-operative MRI scan showed satisfactory union in all cases (100%). Conclusion. It is extremely important to identify this group of injury and treat them early to have satisfactory knee function and avoid long term complications of arthritis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 18 - 18
1 Jul 2022
Thompson R Cassidy R Hill J Bryce L Beverland D
Full Access

Abstract. Aims. The association between body mass index (BMI) and venous thromboembolism (VTE) is well studied, but remains unclear in the literature. We aimed to determine whether morbid obesity (BMI≥40) was associated with increased risk of VTE following total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA), compared to those of BMI<40. Methods. Between January 2016 and December 2020, our institution performed 4506 TKAs and 449 UKAs. 450 (9.1%) patients had a BMI≥40. CT pulmonary angiography (CTPA) for suspected pulmonary embolism (PE) and ultrasound scan for suspected proximal deep vein thrombosis (DVT) were recorded up to 90 days post-operatively. Results. When comparing those of BMI<40 to those with BMI≥40, there was no difference in incidence of PE (1.0% vs 1.1%, p=0.803) or proximal DVT (0.4% vs 0.2%, p=0.645). There was no difference in number of ultrasound scans ordered (p=0.668), or number of CTPAs ordered for those with a BMI≥40 (p=0.176). The percentage of patients with a confirmed PE or proximal DVT were 24.2% and 3.9% respectively in the BMI<40 group, compared to 20.0% (p=0.804) and 2.3% (p=0.598) in the BMI≥40 group. Conclusion. Morbid obesity was not associated with increased risk of PE or proximal DVT within 90 days of TKA or UKA. Overall, 76.3% of CTPAs and 96.2% of ultrasound scans were negative. Increasing the threshold for VTE investigation would reduce the rate of negative investigations. Establishing more effective risk stratification protocols, to guide investigation, would likely reduce unnecessary imaging


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 9 - 9
1 Jul 2022
Fleming T Torrie A Murphy T Dodds A Engelke D Curwen C Gosal H Pegrum J
Full Access

Abstract. INTRODUCTION. COVID-19 reduced availability of cross-sectional imaging, prompting the need to clinically justify pre-operative computed tomography (CT) in tibial plateau fractures (TPF). The study purpose was to establish to what extent does a CT alter the pre-operative plan in TPF compared to radiographs. There is a current paucity of evidence assessing its impact on surgical planning. METHODOLOGY. 50 consecutive TPF with preoperative CT were assessed by 4 consultant surgeons. Anonymised radiographs were assessed defining the column classification, planned setup, approach, and fixation technique. At a 1-month interval, randomised matched CT scans were assessed and the same data collected. A tibial plateau disruption score (TPDS) was derived for all 4 quadrants (no injury=0,split=1,split/depression=2 and depression=3). Radiograph and CT TPDS were assessed using an unpaired T-test. RESULTS. 26 female and 24 male patients, mean age 50.3, were included. Mean TPDS on radiographs and CT scans were 2.77 and 3.17 respectively. A significant higher net CT TPDS was observed of 0.4 (95%CI 0.10-0.71)[P=0.0093]. Both radiograph and CT TPDS ANOVA were significant (P<0.0001), showing high intraobserver variability for TPF classification. Fracture apex requiring fixation changed in 34% of cases between the radiographs and CT, whilst set-up and surgical approach changed in 27% and 28.5% of cases respectively. All surgeons agreed no CT was required in only 11 out of 50 cases. CONCLUSION. CT scanning in TPF significantly affects the classification, setup, approach and fixation technique when compared to radiographs alone and can justifiably be requested as part of pre-operative planning


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 44 - 44
1 Jul 2022
Aujla R Scanlon J Raymond A Ebert J Lam L Gohill S D'Alessandro P
Full Access

Abstract. Introduction. The incidence of significant acute chondral injuries with patella dislocation is around 10–15%. It is accepted that chondral procedures should only be performed in the presence of joint stability. Methodology. Patients were identified from surgeon/hospital logs. Patient demographics, lesion size and location, surgical procedure, patient reported outcome measures, post-operative MR imaging and complications were recorded. PROMs and patient satisfaction was obtained. Results. 20 knees (18 patients) were included. Mean age was 18.6 years (range; 11–39) and the mean follow-up was 16.6 months (range; 2–70). The defect locations were the lateral femoral condyle (9/20; 45%), patella (9/20; 45%), medial femoral condyle (1/20; 5%) and the trochlea (1/20; 5%). The mean defect size was 2.6cm2. Twelve knees were treated with cartilage fixation, 5 with microfracture and 3 with OATS. At follow up, the overall mean Lysholm score was 77.4 (± 17.1) with no chondral regenerative procedure being statistically superior. There was no difference in Lysholm scores between those patients having acute medial patellofemoral ligament reconstruction versus medial soft tissue plication (p=0.59). Five (25%) knees required re-operation (one arthroscopic arthrolysis; one patella chondroplasty; two removal of loose bodies; one implant adjustment). Overall 90% responded as being satisfied with surgery. Conclusion. Our aggressive pathway to identify and treat acute cartilage defects with early operative intervention and patella stabilisation has shown high rates of satisfaction and Lysholm scores with no major revisions. The full range of chondral restoration options should be considered by surgeons managing these patients


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 98 - 98
1 Jul 2022
Vidakovic H Meen R Ohly N
Full Access

Abstract. Introduction. Mako robotic assisted knee arthroplasty requires a planning CT scan within 8 weeks of surgery according to the supplier's protocol. This is often impractical, therefore we evaluated whether CT scans remain valid for an extended period. Methodology. Patients undergoing Mako partial (PKA) and total (TKA) knee arthroplasty were identified from our hospital database. The hospital PACS system was used to define the time interval between the initial planning CT scan and surgery, and whether further imaging was required prior to surgery. Results. 443 consecutive Mako cases (225 TKA and 218 PKA) were undertaken between November 2019 and December 2021 (33 cases to March 2020, and 410 cases from August 2020). CT scans were done within 8 weeks of surgery in 229 patients (51.7%); between 8 and 24 weeks in 148 patients (33.4%); between 24 and 48 weeks in 53 patients (12.0%); and more than 48 weeks in 13 patients (2.9%). Repeat pre-operative radiographs were done in the first 43 patients with a delay to surgery of more than 8 weeks following their CT scan. No gross anatomical changes were identified, and this practice was therefore discontinued. No patients required a repeat CT scan. There were no intra-operative registration errors in any patient in this series. Conclusion. Planning CT scans were valid for up to one year in a large series of patients undergoing Mako PKA and TKA. This may allow for more cost-effective use of resources, while minimising irradiation to patients


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1505 - 1513
1 Sep 2021
Stockton DJ Schmidt AM Yung A Desrochers J Zhang H Masri BA Wilson DR

Aims. Anterior cruciate ligament (ACL) rupture commonly leads to post-traumatic osteoarthritis, regardless of surgical reconstruction. This study uses standing MRI to investigate changes in contact area, contact centroid location, and tibiofemoral alignment between ACL-injured knees and healthy controls, to examine the effect of ACL reconstruction on these parameters. Methods. An upright, open MRI was used to directly measure tibiofemoral contact area, centroid location, and alignment in 18 individuals with unilateral ACL rupture within the last five years. Eight participants had been treated nonoperatively and ten had ACL reconstruction performed within one year of injury. All participants were high-functioning and had returned to sport or recreational activities. Healthy contralateral knees served as controls. Participants were imaged in a standing posture with knees fully extended. Results. Participants’ mean age was 28.4 years (SD 7.3), the mean time since injury was 2.7 years (SD 1.6), and the mean International Knee Documentation Subjective Knee Form score was 84.4 (SD 13.5). ACL injury was associated with a 10% increase (p = 0.001) in contact area, controlling for compartment, sex, posture, age, body mass, and time since injury. ACL injury was associated with a 5.2% more posteriorly translated medial centroid (p = 0.001), equivalent to a 2.6 mm posterior translation on a representative tibia with mean posteroanterior width of 49.4 mm. Relative to the femur, the tibiae of ACL ruptured knees were 2.3 mm more anteriorly translated (p = 0.003) and 2.6° less externally rotated (p = 0.010) than healthy controls. ACL reconstruction was not associated with an improvement in any measure. Conclusion. ACL rupture was associated with an increased contact area, posteriorly translated medial centroid, anterior tibial translation, and reduced tibial external rotation in full extension. These changes were present 2.7 years post-injury regardless of ACL reconstruction status. Cite this article: Bone Joint J 2021;103-B(9):1505–1513


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 81 - 86
1 Jun 2021
Mahfouz MR Abdel Fatah EE Johnson JM Komistek RD

Aims. The objective of this study is to assess the use of ultrasound (US) as a radiation-free imaging modality to reconstruct 3D anatomy of the knee for use in preoperative templating in knee arthroplasty. Methods. Using an US system, which is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allows 3D tracking of the probe, femur, and tibia. The raw US radiofrequency (RF) signals are acquired and, using real-time signal processing, bone boundaries are extracted. Bone boundaries and the tracking information are fused in a 3D point cloud for the femur and tibia. Using a statistical shaping model, the patient-specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was conducted for 17 cadavers by comparing the 3D US models with those created using CT. US scans from 15 users were compared in order to examine the effect of operator variability on the output. Results. The results revealed that the US bone models were accurate compared with the CT models (root mean squared error (RM)S: femur, 1.07 mm (SD 0.15); tibia, 1.02 mm (SD 0.13). Additionally, femoral landmarking proved to be accurate (transepicondylar axis: 1.07° (SD 0.65°); posterior condylar axis: 0.73° (SD 0.41°); distal condylar axis: 0.96° (SD 0.89°); medial anteroposterior (AP): 1.22 mm (SD 0.69); lateral AP: 1.21 mm (SD 1.02)). Tibial landmarking errors were slightly higher (posterior slope axis: 1.92° (SD 1.31°); and tubercle axis: 1.91° (SD 1.24°)). For implant sizing, 90% of the femora and 60% of the tibiae were sized correctly, while the remainder were only one size different from the required implant size. No difference was observed between moderate and skilled users. Conclusion. The 3D US bone models were proven to be closely matched compared with CT and suitable for preoperative planning. The 3D US is radiation-free and offers numerous clinical opportunities for bone visualization rapidly during clinic visits, to enable preoperative planning with implant sizing. There is potential to extend its application to 3D dynamic ligament balancing, and intraoperative registration for use with robots and navigation systems. Cite this article: Bone Joint J 2021;103-B(6 Supple A):81–86