Advertisement for orthosearch.org.uk
Results 1 - 20 of 26
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 265 - 269
1 Feb 2015
Mace J Paton RW

Over a 15-year prospective period, 201 infants with a clinically unstable hip at neonatal screening were subsequently reviewed in a ‘one stop’ clinic where they were assessed clinically and sonographically. Their mean age was 1.62 weeks (95% confidence interval (CI) 1.35 to 1.89). Clinical neonatal hip screening revealed a sensitivity of 62% (mean, 62.6 95%CI 50.9 to 74.3), specificity of 99.8% (mean, 99.8, 95% CI 99.7 to 99.8) and positive predictive value (PPV) of 24% (mean, 26.2, 95% CI 19.3 to 33.0). Static and dynamic sonography for Graf type IV dysplastic hips had a 15-year sensitivity of 77% (mean, 75.8 95% CI 66.9 to 84.6), specificity of 99.8% (mean, 99.8, 95% CI 99.8 to 99.8) and a PPV of 49% (mean, 55.1, 95% CI 41.6 to 68.5). There were 36 infants with an irreducible dislocation of the hip (0.57 per 1000 live births), including six that failed to resolve with neonatal splintage. Most clinically unstable hips referred to a specialist clinic are female and stabilise spontaneously. Most irreducible dislocations are not identified from this neonatal instability group. There may be a small subgroup of females with instability of the hip which may be at risk of progression to irreducibility despite early treatment in a Pavlik harness. A controlled study is required to assess the value of neonatal clinical screening programmes. Cite this article: Bone Joint J 2015;97-B:265-9


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 245 - 248
1 Feb 2009
Myers J Hadlow S Lynskey T

Since September 1964, neonates born in New Plymouth have undergone clinical examination for instability of the hip in a structured clinical screening programme. Of the 41 563 babies born during this period, 1639 were diagnosed as having unstable hips and 663 (1.6%) with persisting instability were splinted, five of which failed. Also, three unsplinted hips progressed to congenital dislocation, and there were four late-presenting (walking) cases, giving an overall failure rate of 0.29 per 1000 live births, with an incidence of late-walking congenital dislocation of the hip of 0.1 per 1000 live births.

This study confirms that clinical screening for neonatal instability of the hip by experienced orthopaedic examiners significantly reduces the incidence of late-presenting (walking) congenital dislocation of the hip.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_11 | Pages 8 - 8
1 Jun 2017
Rymaruk S Rashed R Nie K Choudry Q Paton R
Full Access

Purpose

There is concern that the positive predictive value (PPV) of neonatal screening for instability may have deteriorated over recent years, this study aims to evaluate this.

Method

This is a prospective observational longitudinal study from 2012 – 2016. Patients that were referred from paediatric neonatal screening with hip instability (Ortolani / Barlow positive, clunks) were identified and underwent ultrasound and clinical examination in the one stop hip clinic by the senior author. Referrals were taken from a range of screeners from paediatric doctors to midwives and advanced neonatal practitioners. Syndromic or neurological dislocated hips were excluded. The outcome measures were the presence of a subluxated / dislocated hip on ultrasound as per Graf and Harcke classification and a positive provocative manoeuvre on examination. This allowed a PPV to be evaluated for both ultrasound and clinical examination.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 806 - 810
1 Jun 2018
Choudry QA Paton RW

Aims. The aim of this prospective cohort study was to evaluate the effectiveness of the neonatal hip instability screening programme. Patients and Methods. The study involved a four-year observational assessment of a neonatal hip screening programme. All newborns were examined using the Barlow or Ortolani manoeuvre within 72 hours of birth; those with positive findings were referred to a ‘one-stop’ screening clinic for clinical and sonographic assessment of the hip. The results were compared with previous published studies from this unit. Results. A total of 124 newborns with a positive Barlow or Ortolani manoeuvre, clunk positive, or ‘unstable’ were referred. Five were found to have clinical instability of the hip. Sonographically, 92 newborns had Graf Type I hips, 12 had Graf Type II hips, and 20 had Graf Type IV hips. The positive predictive value (PPV) of clinical screening was 4.0% and the PPV of sonography was 16.1%. This has led to an increased rate of surgery for DDH. Conclusion. Compared with previously published ten-year and 15-year studies, there has been a marked deterioration in the PPV in those referred with potential instability of the hip. There appears to be a paradox, with rising referrals and a decreasing PPV combined with an increasing rate of surgery in newborns with developmental dysplasia of the hip. Cite this article: Bone Joint J 2018;100-B:806–10


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_11 | Pages 5 - 5
1 Jun 2017
Nie K Rymaruk S Paton R
Full Access

Purpose. This 20-year prospective longitudinal observational study aims to determine the incidence of pathological developmental dysplasia of the hip (DDH) in children referred with clicky hips and define the risk posed to inform neonatal hip screening programmes including the role of ultrasound. Method. 355 children from 1997 to 2016 were referred with clicky hips to our “one stop” paediatric hip clinic under the local neonatal hip screening programme. Hips were assessed clinically for instability and by ultrasound using a simplified Graf classification. Dislocated or dislocatable hips were classed as Graf type IV. Results. The mean age at presentation was 13.9 (1–56) weeks. 343 out of 355 (96.6%) were Graf type I which required no treatment. 9 (2.5%) were Graf type II but all converted to Graf type I on follow up scans. 2 (0.6%) had Graf type III dysplasia and 1 (0.3%) had irreducible dislocation but all three were associated with limited hip abduction or other hip pathology. Referrals increased from 12.9 to 22.6 per year (p=0.002) from first decade of the study to the second, driven by rising primary care referrals (5.5 vs. 16.5 per year p=0.00002). Conclusion. The study provided robust evidence that overwhelming majority of clicky hips required no treatment other than reassurance to parents. Clicky hips with normal hip examination should be considered a variant of normal childhood and not a risk factor for DDH. However clicky hips with limited hip abduction may represent a separate clinical entity at risk of hip pathology and therefore warrant further investigations


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1533 - 1536
1 Nov 2017
Nie K Rymaruk S Paton RW

Aims. A clicky hip is a common referral for clinical and sonographic screening for developmental dysplasia of the hip (DDH). There is controversy regarding whether it represents a true risk factor for pathological DDH. Therefore a 20-year prospective, longitudinal, observational study was undertaken to assess the relationship between the presence of a neonatal clicky hip and pathological DDH. Patients and Methods. A total of 362 infants from 1997 to 2016 were referred with clicky hips to our ‘one-stop’ paediatric hip screening clinic. Hips were assessed clinically for instability and by ultrasound imaging using a simplified Graf/Harcke classification. Dislocated or dislocatable hips were classified as Graf Type IV hips. Results. The mean age at presentation was 13.8 weeks (12.8 to 14.7). In all 351 out of 362 children (97.0%) had Graf Type I hips (normal) that required no treatment. Nine children (2.5%) had Graf Type II hips but all resolved to Graf Type I hips on follow-up scans. One child (0.3%) had Graf Type III hip dysplasia and one child (0.3%) had an irreducible hip dislocation. The two pathological hips were associated with unilateral limited hip abduction. Mean referrals increased from 12.9 to 23.3 each year (p = 0.002) from the first decade of the study to the second, driven by increasing primary care referrals (5.5 versus 16.7 per year, p < 0.001). Conclusion. Most clicky hips required no treatment other than reassurance to parents. Clicky hips with a normal hip examination should be considered a variant of normal childhood and not a risk factor for DDH. However, an abnormal hip examination including unilateral limited hip abduction should prompt urgent further investigations. Cite this article: Bone Joint J 2017;99-B:1533–6


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 495 - 500
1 Apr 2020
Milligan DJ Cosgrove AP

Aims. To monitor the performance of services for developmental dysplasia of the hip (DDH) in Northern Ireland and identify potential improvements to enhance quality of service and plan for the future. Methods. This was a prospective observational study, involving all infants treated for DDH between 2011 and 2017. Children underwent clinical assessment and radiological investigation as per the regional surveillance policy. The regional radiology data was interrogated to quantify the use of ultrasound and ionizing radiation for this population. Results. Evidence-based changes were made to the Northern Ireland screening programme, including an increase in ultrasound scanning capacity and expansion of nurse-led screening clinics. The number of infant hip ultrasound scans increased from 4,788 in 2011, to approximately 7,000 in 2013 and subsequent years. The number of hip radiographs on infants of less than one year of age fell from 7,381 to 2,208 per year. There was a modest increase in the treatment rate from 10.9 to 14.3 per 1,000 live births but there was a significant reduction in the number of closed hip reductions. The incidence of infants diagnosed with DDH after one year of age was 0.30 per 1,000 live births over the entire period. Conclusion. Improving compliance with the regional infant hip screening protocols led to reduction in operative procedures and reduced the number of pelvic radiographs of infants. We conclude that performance monitoring of screening programmes for DDH is essential to provide a quality service. Cite this article: Bone Joint J 2020;102-B(4):495–500


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_15 | Pages 17 - 17
1 Sep 2016
Nogaro M Monk A Wittmann U Buckingham R
Full Access

The aim was to determine reliability in treatment threshold based on USS angular measurements between observers involved in the DDH hip screening programme at the NOC and assess the effect of image orientation on the accuracy of these measurements. 3 independent observers measured alpha and beta angles on bilateral hips in 10 consecutive patients seen in the DDH hip screening clinic. All scans were performed by a single radiographer and observers used the same set of USS images for a given patient. Each observer measured alpha and beta angles a total of 4 times: conventional ultrasound image projection (with the ilium horizontal) (round 1), Graf's anatomical projection (round 2), and both techniques repeated 1 month later (round 3 and 4 respectively) to assess intra-observer reliability. To determine its effect on treatment threshold taking into account alpha and beta angles and patient's age, the consistency between observers' management recommendations was evaluated for each round. Possible outcomes were: 1) patient discharged, 2) no treatment needed yet, but follow-up required, 3) start treatment. Intra-observer reliability for conventional projection was moderate (Kappa 0.58), and improved for anatomical projection (Kappa 0.65). Inter-observer reliability, as a surrogate measure of consistency in management recommendations between observers, ranged from fair to moderate across the 4 rounds (Kappa 0.30 – 0.50). However, contrary to previous recommendations, reliability was better with conventional projection (Kappa 0.41 (95% CI 0.11–0.72)) compared to anatomical projection (Kappa 0.36 (95% CI −0.01–0.73)). The overall agreement in management recommendations, pooling all results across 4 rounds, was 51.3% (Kappa 0.39 (95%CI 0.15–0.63)). This audit supports the argument that anatomical image projection improves intra-observer consistency. However, as with all USS measurements, angular measurements were highly user dependent and treatment threshold based on USS may not be as consistent as anticipated


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_15 | Pages 5 - 6
1 Sep 2016
Davies R Mace J Talbot C Paton R
Full Access

The aim was to assess the value of the GP 6–8 week hip examination. In a 15-year prospective observational longitudinal cohort study, every infant referred by the GP with suspected pathological developmental dysplasia of the hip (DDH) had their hip joints clinically and sonographically examined in a specialist hip screening clinic. Graf Type IV and dislocated hips were classified as pathological. Screening failures were defined as those who had not been identified by the 6–8 week check and presented with late instability. Secondary univariate and multivariable analysis was performed to determine which clinical findings are predictive of instability. 64,518 infants underwent the 6–8 week GP check. Of 176 referrals, 5 had pathological hips. 13 screening failures, presented between the ages of 17 and 80 weeks. The 6–8 week check has a sensitivity of 28% and a specificity of 99.7%. Univariate analysis revealed positive Ortolani tests and patients referred as ‘unstable hip’ to be significant predictors of hip pathology. Clicky hips, asymmetric skin creases, and leg length inequality were not predictive of pathological hips. A multivariable model showed a positive Ortolani test to be the sole independent predictor of instability at 6–8 weeks. This is the first attempt to test the validity of the 6–8 week GP clinical hip check. A low rate of hip pathology was identified. The high rate of false negatives raises questions about the value of screening at this age. At 6–8 weeks, clinical signs of hip instability are unreliable as hips become irreducible and stiff. Based on our findings, we recommend that at 6–8 weeks, referrals are only made if the Ortolani test is positive. We advocate the reintroduction of the 8-month check, including an assessment for limited hip abduction, which may improve the detection rate of those missed by initial screening


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 585 - 589
1 May 2004
Wirth T Stratmann L Hinrichs F

Between 1985 and 1998, 12 331 patients were included in the general neonatal ultrasound hip screening programme for developmental dysplasia of the hip (DDH). Patients who needed treatment (604) were compared with a second group of 73 unscreened children treated conservatively and surgically for DDH. The incidence of Graf sonographic hip types IIc to IV varied throughout the observation period. Femoral and pelvic osteotomies were almost entirely restricted to the unscreened group of patients. The six to ten per year recorded in the period 1985 to 1990 declined subsequently to three or less per year. The yearly admissions to hospital fell noticeably after six years of screening. Late presentations of DDH were reduced to three or less per year from 1990 to 1994, none between 1995 and 1998 and one or two per year from 2000. We conclude that general neonatal sonographic hip screening can reduce significantly surgical procedures, hospitalisation and late presentation of DDH


Bone & Joint Open
Vol. 4, Issue 5 | Pages 363 - 369
22 May 2023
Amen J Perkins O Cadwgan J Cooke SJ Kafchitsas K Kokkinakis M

Aims

Reimers migration percentage (MP) is a key measure to inform decision-making around the management of hip displacement in cerebral palsy (CP). The aim of this study is to assess validity and inter- and intra-rater reliability of a novel method of measuring MP using a smart phone app (HipScreen (HS) app).

Methods

A total of 20 pelvis radiographs (40 hips) were used to measure MP by using the HS app. Measurements were performed by five different members of the multidisciplinary team, with varying levels of expertise in MP measurement. The same measurements were repeated two weeks later. A senior orthopaedic surgeon measured the MP on picture archiving and communication system (PACS) as the gold standard and repeated the measurements using HS app. Pearson’s correlation coefficient (r) was used to compare PACS measurements and all HS app measurements and assess validity. Intraclass correlation coefficient (ICC) was used to assess intra- and inter-rater reliability.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 3 - 8
2 Jan 2024
Husum H Hellfritzsch MB Maimburg RD Møller-Madsen B Henriksen M Lapitskaya N Kold S Rahbek O

Aims

The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%.

Methods

We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 913 - 923
28 Nov 2022
Hareendranathan AR Wichuk S Punithakumar K Dulai S Jaremko J

Aims

Studies of infant hip development to date have been limited by considering only the changes in appearance of a single ultrasound slice (Graf’s standard plane). We used 3D ultrasound (3DUS) to establish maturation curves of normal infant hip development, quantifying variation by age, sex, side, and anteroposterior location in the hip.

Methods

We analyzed 3DUS scans of 519 infants (mean age 64 days (6 to 111 days)) presenting at a tertiary children’s hospital for suspicion of developmental dysplasia of the hip (DDH). Hips that did not require ultrasound follow-up or treatment were classified as ‘typically developing’. We calculated traditional DDH indices like α angle (αSP), femoral head coverage (FHCSP), and several novel indices from 3DUS like the acetabular contact angle (ACA) and osculating circle radius (OCR) using custom software.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 198 - 208
1 Feb 2023
Cheok T Smith T Wills K Jennings MP Rawat J Foster B

Aims

We investigated the prevalence of late developmental dysplasia of the hip (DDH), abduction bracing treatment, and surgical procedures performed following the implementation of universal ultrasound screening versus selective ultrasound screening programmes.

Methods

A systematic search of PubMed, Embase, The Cochrane Library, OrthoSearch, and Web of Science from the date of inception of each database until 27 March 2022 was performed. The primary outcome of interest was the prevalence of late detection of DDH, diagnosed after three months. Secondary outcomes of interest were the prevalence of abduction bracing treatment and surgical procedures performed in childhood for dysplasia. Only studies describing the primary outcome of interest were included.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_1 | Pages 3 - 3
1 Jan 2014
Hughes S Jugdey R Choudry Q Paton R
Full Access

Aim:. An assessment of the relationship between pathological Developmental Dysplasia of the Hip (DDH) and Congenital Talipes Equinovarus (CTEV). Introduction:. Traditional UK guidelines consider abnormalities of the foot to be a risk factor for DDH. 1,2. Currently, there is controversy whether congenital foot abnormalities are true risk factors for pathological DDH. 3,4. There is a relationship between CTCV and hip dysplasia though the relationship between CTEV and pathological DDH is less clear. 5. In a previous 11 year prospective longitudinal study no case of Graf Types III, IV or irreducible hip dislocation were associated with CTEV. 5. Subsequent correspondence and case histories have challenged this view. 6. Methods:. In order to clarify this issue, a 20-year prospective longitudinal observational study was undertaken. All cases of fixed CTEV (Harold & Walker types 1 to 3) referred to the sub-regional Paediatric Orthopaedic clinic at the Royal Blackburn Hospital were evaluated, the feet and hips clinically assessed (Ortolani & Barlow manoeuvres) and the hips ultra-sounded by the senior author (RWP). Modified Graf and Harcke hip ultrasound classification systems were employed. Graf Type III, IV and irreducible hip dislocation were considered pathological. Results:. The incidence of CTEV was 1.46 per 1000 live births (nationally quoted incidence of 1 to 2 per 1000 live births. 7. ). There was one case of Graf Type III dysplasia with no cases of clinical hip instability. Currently, the clinical significance of this type of dysplasia is uncertain. There were no cases of Graf Type IV dislocations or radiological irreducible hip dislocation. Conclusion:. Fixed CTEV should not be considered as a risk factor for pathological DDH and routine sonographic hip screening of CTEV should not be advocated. This is supportive evidence for the current English NIPE guidelines in which the only risk factors screened are family history and breech presentation. Level of evidence: II


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 104 - 107
1 Jan 2002
Jari S Paton RW Srinivasan MS

Between 1992 and 1997, we undertook a prospective, targeted clinical and ultrasonographic hip screening programme to assess the relationship between ultrasonographic abnormalities of the hip and clinical limitation of hip abduction. A total of 5.9% (2 of 34) of neonatal dislocatable hips and 87.5% (7 of 8) of ‘late’ dislocated hips seen after the age of six months, presented with unilateral limitation of hip abduction. All major (Graf type III) and 44.5% of minor (Graf type II) dysplastic hips presented with this sign. Statistically, bilateral limitation of hip abduction was not a useful clinical indicator of underlying hip abnormality because of its poor sensitivity, but unilateral limitation of abduction of the hip was a highly specific (90%) and reasonably sensitive sign (70%). It was more sensitive than the neonatal Ortolani manoeuvre, which has been considered to be the method of choice. It was, however, not sensitive enough to be of value as a routine screening test in developmental dysplasia of the hip. We consider unilateral limitation of hip abduction to be an important clinical sign and its presence in an infant over the age of three to four months makes further investigation essential


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1126 - 1130
1 Aug 2011
Thaler M Biedermann R Lair J Krismer M Landauer F

Between 1978 and 1997 all newborns in the Austrian province of Tyrol were reviewed regarding hip dysplasia and related surgery. This involved a mean of 8257 births per year (7766 to 8858). Two observation periods were determined: 1978 to 1982 (clinical examination alone) and 1993 to 1997 (clinical examination and universal ultrasound screening). A retrospective analysis compared the number and cost of interventions due to hip dysplasia in three patient age groups: A, 0 to < 1.5 years; B, ≥ 1.5 to < 15 years; and C, ≥ 15 to < 35 years. In group A, there was a decrease in hip reductions from a mean of 25.2 (. sd. 2.8) to 7.0 (. sd. 1.4) cases per year. In group B, operative procedures decreased from a mean of 17.8 (. sd. 3.5) to 2.6 (. sd. 1.3) per year. There was a 75.9% decrease in the total number of interventions for groups A and B. An increase of €57 000 in the overall cost per year for the second period (1993 to 1997) was seen, mainly due to the screening programme. However, there was a marked reduction in costs of all surgical and non-surgical treatments for dysplastic hips from €410 000 (1978 to 1982) to €117 000 (1993 to 1997). We believe the small proportional increase in costs of the universal ultrasound screening programme is justifiable as it was associated with a reduction in the number of non-surgical and surgical interventions. We therefore recommend universal hip ultrasound screening for neonates


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1582 - 1586
1 Nov 2020
Håberg Ø Foss OA Lian ØB Holen KJ

Aims

To assess if congenital foot deformity is a risk factor for developmental dysplasia of the hip (DDH).

Methods

Between 1996 and 2012, 60,844 children were born in Sør-Trøndelag county in Norway. In this cohort study, children with risk factors for DDH were examined using ultrasound. The risk factors evaluated were clinical hip instability, breech delivery, a family history of DDH, a foot deformity, and some syndromes. As the aim of the study was to examine the risk for DDH and foot deformity in the general population, children with syndromes were excluded. The information has been prospectively registered and retrospectively analyzed.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1767 - 1773
1 Dec 2020
Maikku M Ohtonen P Valkama M Leppilahti J

Aims

We aimed to determine hip-related quality of life and clinical findings following treatment for neonatal hip instability (NHI) compared with age- and sex-matched controls. We hypothesized that NHI would predispose to hip discomfort in long-term follow-up.

Methods

We invited those born between 1995 and 2001 who were treated for NHI at our hospital to participate in this population-based study. We included those that had Von Rosen-like splinting treatment started before one month of age. A total of 96 patients treated for NHI (75.6 %) were enrolled. A further 94 age- and sex-matched controls were also recruited. The Copenhagen Hip and Groin Outcome Score (HAGOS) questionnaire was completed separately for both hips, and a physical examination was performed.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 635 - 638
1 Jun 2019
Marson BA Hunter JB Price KR

Aims

The aim of this study was to review the value of accepting referrals for children with ‘clicky hips’ in a selective screening programme for hip dysplasia.

Patients and Methods

A single-centre prospective database of all referrals to the hip clinic was examined to identify indication for referrals, diagnosis, and treatment. All patients referred received a standardized ultrasound scan and clinical examination by an orthopaedic consultant.