Acetabulum fractures caused by civilian firearms represent a unique challenge for orthopaedic surgeons. Treatment strategies should include the assessment of infection risk due to frequently associated abdominal injuries and maintenance of joint function. Still, internationally accepted treatment algorithms are not available. The aim of the study was to increase knowledge about civilian gunshot
Aims. Accurate placement of acetabular and femoral stem components in total hip arthroplasty (THA) is an important factor in the success of the procedure. A variety of free hand or navigated techniques is reported. Survivorship and complications have been shown to be directly related to implant position during THA. The aim of this cadaver study was to assess the accuracy of the placement of the components in THA using patient specific instruments (PSI) in combination with a 3D planning software and the direct anterior approach. Method. Patient specific instruments (PSI) were developed to guide the surgeon during THA that were 3D printed with their bone models following a 3D software planning protocol (LPH software V2.5.1, Onefit-Medical, Eos Imaging Company, Besancon, France). Acetabular guides: cup, offset and straight reamer handle and impactor, femoral- and chisel guides were used in each THA (Fig. 1). To define anatomic bone landmarks and to generate a 3D model of each hip joint CT scans were performed preoperatively. The planning of component position was done by one surgeon (AZ) preop. Surgery was performed by two experienced surgeons (AZ, SD) on cadaver specimen with 4 hips in two separate series. A total of 8 hip replacements were evaluated pre- and postoperatively using CT-scans of each hip joint to compare planned to achieved results. Mechanical simulations of the guides were carried out to verify that there were no conflicts between the different instruments. To meet the ISO standard 16061: 2015 the compatibility of the instruments with the guides has been checked. Parameters were evaluated in 3D pelvic and femoral planes: center cup position, inclination angle, anteversion angle, cutting height and plan orientation, anteversion angle, flexion/extension angle, varus/valgus angle, anatomical and functional leg length, offset. Acceptance criteria: postop. parameters evaluated must not have a deviation of more than 5 degrees, 2,5 mm according to preop. planning. For every THA the test protocol has been completely realized. Results. The difference between the preop. and postop. measures in the first series of 4 hips revealed 2 outliers because of
Objective. To investigate the relationship between the pattern of pelvic or acetabular fracture, and bladder injuries. Methods. A total of 173 patients admitted at our Academic Hospital from January 2006 to March 2012 with cystograms done for pelvic or acetabular fractures were studied retrospectively. Records of pelvic X-Rays, CT scans and cystograms were reviewed. Tile's classification and Young & Burgess classification were used for pelvic fractures and Judet & Letournel classification system for acetabular fractures. Results. Out of 173 patients 16% had bladder injuries of which 22% were intra-peritoneal and 70% were extra-peritoneal. The bladder injuries mostly occurred among male patients; 16 males compared to 9 female patients. Out of the 21
The inability to consistently position components is associated with the major complications of hip replacement including instability, wear, liner breakage, limb length discrepancy, and limited function. This was a major catalyst for the demise of hard-on-hard bearings. The greatest challenge is accurate, reproducible positioning of acetabular component which is obtained in a surprisingly low percentage of cases. Other major issues include consistently obtaining proper limb length, offset, component sizing, and complete seating without
Injury to the sciatic nerve is one of the more serious complications of acetabular fracture and traumatic dislocation of the hip, both in the short and long term. We have reviewed prospectively patients, treated in our unit, for acetabular fractures who had concomitant injury to the sciatic nerve, with the aim of predicting the functional outcome after these injuries. Of 136 patients who underwent stabilisation of acetabular fractures, there were 27 (19.9%) with neurological injury. At initial presentation, 13 patients had a complete foot-drop, ten had weakness of the foot and four had burning pain and altered sensation over the dorsum of the foot. Serial electromyography (EMG) studies were performed and the degree of functional recovery was monitored using the grading system of the Medical Research Council. In nine patients with a foot-drop, there was evidence of a proximal acetabular (sciatic) and a distal knee (neck of fibula) nerve lesion, the double-crush syndrome. At the final follow-up, clinical examination and EMG studies showed full recovery in five of the ten patients with initial muscle weakness, and complete resolution in all four patients with sensory symptoms (burning pain and hyperaesthesia). There was improvement of functional capacity (motor and sensory) in two patients who presented initially with complete foot-drop. In the remaining 11 with foot-drop at presentation, including all nine with the double-crush lesion, there was no improvement in function at a mean follow-up of 4.3 years.
This study was undertaken to evaluate the safety and efficacy of retrievable inferior vena cava filters in high-risk orthopaedic patients. A total of 58 patients had a retrievable inferior vena cava filter placed as an adjunct to chemical and mechanical prophylaxis, most commonly for a history of previous deep-vein thrombosis or pulmonary embolism, polytrauma, or expected prolonged immobilisation. In total 56 patients (96.6%) had an uncomplicated post-operative course. Two patients (3.4%) died in the peri-operative period for unrelated reasons. Of the 56 surviving patients, 50 (89%) were available for follow-up. A total of 32 filters (64%) were removed without complication at a mean of 37.8 days (4 to 238) after placement. There were four filters (8%) which were retained because of thrombosis at the filter site, and four (8%) were retained because of incorporation of the filter into the wall of the inferior vena cava. In ten cases (20%) the retrievable filter was left in place to continue as primary prophylaxis. No patient had post-removal thromboembolic complications. A retrievable inferior vena cava filter, as an adjunct to chemical and mechanical prophylaxis, was a safe and effective means of reducing the acute risk of pulmonary embolism in this high-risk group of patients. Although most filters were removed without complications, thereby avoiding the long-term complications that have plagued permanent indwelling filters, a relatively high percentage of filters had to be left