Advertisement for orthosearch.org.uk
Results 1 - 20 of 114
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1265 - 1270
1 Dec 2023
Hurley ET Sherman SL Chahla J Gursoy S Alaia MJ Tanaka MJ Pace JL Jazrawi LM

Aims. The aim of this study was to establish consensus statements on medial patellofemoral ligament (MPFL) reconstruction, anteromedialization tibial tubercle osteotomy, trochleoplasty, and rehabilitation and return to sporting activity in patients with patellar instability, using the modified Delphi process. Methods. This was the second part of a study dealing with these aspects of management in these patients. As in part I, a total of 60 surgeons from 11 countries contributed to the development of consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered unanimous. Results. Of 41 questions and statements on patellar instability, none achieved unanimous consensus, 19 achieved strong consensus, 15 achieved consensus, and seven did not achieve consensus. Conclusion. Most statements reached some degree of consensus, without any achieving unanimous consensus. There was no consensus on the use of anchors in MPFL reconstruction, and the order of fixation of the graft (patella first versus femur first). There was also no consensus on the indications for trochleoplasty or its effect on the viability of the cartilage after elevation of the osteochondral flap. There was also no consensus on postoperative immobilization or weightbearing, or whether paediatric patients should avoid an early return to sport. Cite this article: Bone Joint J 2023;105-B(12):1265–1270


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 94 - 94
1 Jul 2012
Sprowson AP Aldridge SA Rankin KS Packham IN Wood DG
Full Access

Purpose. The purpose of this study was to assess radiologically the absorption of a poly L-lactide bioabsorbable interference screw used in anterior ligament reconstruction. Methods. A case series of ten sequential patients undergoing anterior ligament reconstruction with a four-strand hamstrings technique were assessed with MRI scans at one, two, four, seven and ten years postoperatively. The scans were reported by an independent radiologist, with respect to resorption of the screw and post resorption changes in the bone. Fixation of the graft in ACL surgery is varied from metal interference screw, resorbable screws made of PLLA, and staple fixation. The advantage of resorbable screws allow imaging of the knee postoperatively, and the perceive benefit of screw resorption and replacement with host bone. Results. No resorption had occurred after 4 years in any of the patients. By seven years screw absorption was complete in seven patients and progressive in three. Five patients displayed new bone formation within the tibial tunnel. Of the five patients with no demonstrable new bone formation, a fluid collection was present within the tibial tunnel. In one of these patients, MRI revealed formation of a ganglion beyond the limit of the tunnel. We will present the final data after ten years. Conclusions. This study has shown that the bioabsorbable screws take longer to resorb than initial in vitro data. It is unclear as to whether any ganglion formation is related to the resorption, or the presence of the hamstring graft in the tunnel. The theoretical advantages of bio-absorbable screws must be weighed against these findings


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 593 - 603
1 May 2005
Harvey A Thomas NP Amis AA


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 943 - 946
1 Nov 1994
Stranks G Cecil T Jeffery I

We report a new method of ankle arthrodesis which combines an anterior approach with a dowel technique of bone grafting and screw fixation. In 20 ankles of 20 patients, ten with osteoarthritis, eight with rheumatoid arthritis and two others, we achieved 19 solid bony fusions and one painless fibrous ankylosis. The average time to union was 12.5 weeks. Patient satisfaction was high and the functional results were as good as for other reported methods, with fewer complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 121 - 126
1 Jan 2007
Jensen TB Overgaard S Lind M Rahbek O Bünger C Søballe K

Impacted bone allograft is often used in revision joint replacement. Hydroxyapatite granules have been suggested as a substitute or to enhance morcellised bone allograft. We hypothesised that adding osteogenic protein-1 to a composite of bone allograft and non-resorbable hydroxyapatite granules (ProOsteon) would improve the incorporation of bone and implant fixation. We also compared the response to using ProOsteon alone against bone allograft used in isolation. We implanted two non-weight-bearing hydroxyapatite-coated implants into each proximal humerus of six dogs, with each implant surrounded by a concentric 3 mm gap. These gaps were randomly allocated to four different procedures in each dog: 1) bone allograft used on its own; 2) ProOsteon used on its own; 3) allograft and ProOsteon used together; or 4) allograft and ProOsteon with the addition of osteogenic protein-1.

After three weeks osteogenic protein-1 increased bone formation and the energy absorption of implants grafted with allograft and ProOsteon. A composite of allograft, ProOsteon and osteogenic protein-1 was comparable, but not superior to, allograft used on its own.

ProOsteon alone cannot be recommended as a substitute for allograft around non-cemented implants, but should be used to extend the volume of the graft, preferably with the addition of a growth factor.


To illustrate our clinical experience of using a complete biological method of fixation in ACL surgery and correlate the histology at the graft and the host bone interface performed in an animal experiment.

Materials: 18 male patients of mean age were 31.2 years (range 18 to 50 years) were operated on. The autogenous graft prepared from lateral part of the quadriceps aponeurosis, part of the patella and ligament leaving distal tibial attachment, passed through the trans-osseous tunnel so that bony part of the graft stay within the femoral tunnel, remaining part was sutured with the iliotibial tract.

Patients began immediate knee exercises with continous-passive-motion devices in the recovery room. With 100 degrees of knee motion, they allowed to bear full weight on the operatively treated limb with knee in a brace in extension

Results: 3 patients had superficial wound infection and 2 had haemarthrosis. None had any laxity or flexion contracture, mean flexion arc was135 (130–145) degree.

Conclusion: Histology of the bone graft and host tunnel confirms full incorporation of the graft in experimental animals performed by our senior author. The procedure of biologic fixation method in ACL reconstruction surgery to preserve the biological integrity of the patellar ligament distally in the tibial end may avoid early failure in fixation method. The biological integration producing a bone block in the femoral tunnel may enable clinician to start early rehabilitation program.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 999 - 1003
7 Nov 2024
Tan SHS Pei Y Chan CX Pang KC Lim AKS Hui JH Ning B

Aims. Congenital pseudarthrosis of the tibia (CPT) has traditionally been a difficult condition to treat, with high complication rates, including nonunion, refractures, malalignment, and leg length discrepancy. Surgical approaches to treatment of CPT include intramedullary rodding, external fixation, combined intramedullary rodding and external fixation, vascularized fibular graft, and most recently cross-union. The current study aims to compare the outcomes and complication rates of cross-union versus other surgical approaches as an index surgery for the management of CPT. Our hypothesis was that a good index surgery for CPT achieves union and minimizes complications such as refractures and limb length discrepancy. Methods. A multicentre study was conducted involving two institutions in Singapore and China. All patients with CPT who were surgically managed between January 2009 and December 2021 were included. The patients were divided based on their index surgery. Group 1 included patients who underwent excision of hamartoma, cross-union of the tibia and fibula, autogenic iliac bone grafting, and internal fixation for their index surgery. Group 2 included patients who underwent all other surgical procedures for their index surgery, including excision of hamartoma, intramedullary rodding, and/or external fixation, without cross-union of the tibia and fibula. Comparisons of the rates of union, refracture, limb length discrepancy, reoperations, and other complications were performed between the two groups. Results. A total of 36 patients were included in the study. Group 1 comprised 13 patients, while Group 2 comprised 23 patients. The mean age at index surgery was four years (1 to 13). The mean duration of follow-up was 4.85 years (1.75 to 14). All patients in Group 1 achieved bony union at a mean of three months (1.5 to 4), but ten of 23 patients in Group 2 had nonunion of the pseudarthrosis (p = 0.006). None of the patients in Group 1 had a refracture, while seven of 13 patients who achieved bony union in Group 2 suffered a refracture (p = 0.005). None of the patients in Group 1 had a limb length discrepancy of more than 2 cm, while ten of 23 patients in Group 2 have a limb length discrepancy of more than 2 cm (p = 0.006). In Group 1, four of 13 patients had a complication, while 16 of 23 patients in Group 2 had a complication (p = 0.004). Excluding removal of implants, four of 13 patients in Group 1 had to undergo additional surgery, while 18 of 23 patients in Group 2 had to undergo additional surgery following the index surgery (p = 0.011). Conclusion. A good index surgery of excision of hamartoma, cross-union of the tibia and fibula, autogenic iliac bone grafting, and internal fixation for CPT achieves union and minimizes complications such as refractures, limb length discrepancy, and need for additional surgeries


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 66 - 66
1 Dec 2022
Martin R Matovinovic K Schneider P
Full Access

Ligament reconstruction following multi-ligamentous knee injuries involves graft fixation in bone tunnels using interference screws (IS) or cortical suspensory systems. Risks of IS fixation include graft laceration, cortical fractures, prominent hardware, and inability to adjust tensioning once secured. Closed loop suspensory (CLS) fixation offers an alternative with fewer graft failures and improved graft-to-tunnel incorporation. However, graft tensioning cannot be modified to accommodate errors in tunnel length evaluation. Adjustable loop suspensory (ALS) devices (i.e., Smith & Nephew Ultrabutton) address these concerns and also offer the ability to sequentially tighten each graft, as needed. However, ALS devices may lead to increased graft displacement compared to CLS devices. Therefore, this study aims to report outcomes in a large clinical cohort of patients using both IS and CLS fixation. A retrospective review of radiographic, clinical, and patient-reported outcomes following ligament reconstruction from a Level 1 trauma centre was completed. Eligible patients were identified via electronic medical records using ICD-10 codes. Inclusion criteria were patients 18 years or older undergoing ACL, PCL, MCL, and/or LCL reconstruction between January 2018 and 2020 using IS and/or CLS fixation, with a minimum of six-month post-operative follow-up. Exclusion criteria were follow-up less than six months, incomplete radiographic imaging, and age less than 18 years. Knee dislocations (KD) were classified using the Schenck Classification. The primary outcome measure was implant removal rate. Secondary outcomes were revision surgery rate, deep infection rate, radiographic fixation failure rate, radiographic malposition, Lysholm and Tegner scores, clinical graft failure, and radiographic graft failure. Radiographic malposition was defined as implants over 5 mm off bone or intraosseous deployment of the suspensory fixation device. Clinical graft failure was defined as a grade II or greater Lachman, posterior drawer, varus opening at 20° of knee flexion, and/or valgus opening at 20° of knee flexion. Radiographic failure was defined when over 5 mm, 3.2 mm, and/or 2.7 mm of side-to-side difference occurred using PCL gravity stress views, valgus stress views, and/or varus stress views, respectively. Descriptive statistics were used. Sixty-three consecutive patients (mean age = 41 years, range = 19-58) were included. A total of 266 CLS fixation with Ultrabuttons and 135 IS were used. Mean follow-up duration was 383 days. Most injuries were KD type II and III. Graft revision surgery rate was 1.5%. Intraosseous deployment occurred in 6.2% and 17% had implants secured in soft tissue, rather than on bone. However, the implant removal rate was only 6.2%. Radiographic PCL gravity stress views demonstrated an average of 1.2 mm of side-to-side difference with 6.2% meeting criteria for radiographic failure. A single patient met radiographic failure criteria for collateral grafts. Mean Lysholm and Tegner scores were 87.3 and 4.4, respectively, with follow-up beyond one year. Both IS and CLS fixation demonstrate an extremely low revision surgery rate, a high rate of implant retention, excellent radiographic stability, and satisfactory patient-reported outcome scores. Incorrect implant deployment was seen in a total of 17% of patients, yet none required implant removal. A single patient required graft revision due to implant failure


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims. Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. Methods. We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. Results. Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. Conclusion. Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation. Cite this article: Bone Jt Open 2022;3(12):991–997


Abstract. Background. Extracorporeal radiation therapy (ECRT) has been reported as an oncologically safe and effective reconstruction technique for limb salvage in diaphyseal sarcomas with promising functional results. Factors affecting the ECRT graft-host bone incorporation have not been fully investigated. Methods. In our series of 51 patients of primary bone tumors treated with ECRT, we improvised this technique by using a modified V-shaped osteotomy, additional plates and intra-medullary fibula across the diaphyseal osteotomy in an attempt to increase the stability of fixation, augment graft strength and enhance union at the osteotomy sites. We analyzed our patients for various factors that affected union time and union rate at the osteotomy sites. Results. On univariate analysis, age <20 years, metaphyseal osteotomy site, V-shaped diaphyseal osteotomy, extramedullary plate fixation and use of additional plate at diaphyseal ostetomy had a significantly faster time to union while gender, tumor type, resection length, chemotherapy and use of intra-medullary fibula did not influence union time. In multivariate analysis, metaphyseal ostoeotomy, V-shaped diaphyseal osteotomy and use of additional plate at diaphyseal ostetomy were the independent factors with favourable time to union. Although the rate of union was higher with V-shaped diaphyseal osteotomy and use of additional plate and intra-medullary fibula at diaphyseal ostetomy, this difference could not be established statistically. None of the analyzed factors apparently affected the union rate in univariate analysis. Conclusion. Judicious choice of osteosynthesis and augmentation of ECRT graft can enhance incorporation with reduced complications and good functional outcome


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 19 - 19
1 Nov 2019
Vijayan S Kulkarni MS Shetty S Naik AM Rao SK
Full Access

Anterior cruciate ligament (ACL) injuries are one of the most common ligament injury occurring in young and active individuals. Reconstruction of the torn ligament is the current standard of care. Of the many factors which determine the surgical outcome, fixation of the graft in the bony tunnels has significant role. This study compared the clinical and functional outcome in patients who underwent ACL reconstruction by standard anteromedial portal technique with single bundle hamstring graft anchored in the femoral tunnel using rigidfix and cortical button with adjustable loops. The tibial fixation and rehabilitation protocol were same in both groups. 107 patients underwent ACL reconstruction over a two-year period (87 males, 20 females, 44 after motor vehicle accident, 34 after sports injuries, 79 isolated ACL tear, 21 associated medial meniscus tear, 16 lateral meniscus tear and 11 both menisci). Rigid fix group had 47 patients and adjustable loop 60 patients. Clinical evaluation at end of one year showed better stability in rigid fix group regarding Lachman, anterior drawer, pivot shift tests, KT 1000 arthrometer side to side difference and hop limb symmetry index. However, the differences were not statistically significant. Functional evaluation using IKDC 2000 subjective score and Lysholm score showed better results in rigidfix group than variable loop, but was not statistically significant. However, lower scores were noted in patients with concomitant meniscal injury than in isolated acl tear patients and this was statistically significant in both groups. Rigidfix seems to give better graft fixation on femoral side than variable loop, but by the end of one year the functional outcome is comparable in isolated acl reconstructions


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 293 - 301
1 Jun 2020
Hexter AT Hing KA Haddad FS Blunn G

Aims. To evaluate graft healing of decellularized porcine superflexor tendon (pSFT) xenograft in an ovine anterior cruciate ligament (ACL) reconstruction model using two femoral fixation devices. Also, to determine if pSFT allows functional recovery of gait as compared with the preoperative measurements. Methods. A total of 12 sheep underwent unilateral single-bundle ACL reconstruction using pSFT. Two femoral fixation devices were investigated: Group 1 (n = 6) used cortical suspensory fixation (Endobutton CL) and Group 2 (n = 6) used cross-pin fixation (Stratis ST). A soft screw was used for tibial fixation. Functional recovery was quantified using force plate analysis at weeks 5, 8, and 11. The sheep were euthanized after 12 weeks and comprehensive histological analysis characterized graft healing at the graft-bone interface and the intra-articular graft (ligamentization). Results. The pSFT remodelled into a ligament-like structure and no adverse inflammatory reaction was seen. The ground reaction force in the operated leg of the Endobutton group was higher at 11 weeks (p < 0.05). An indirect insertion was seen at the graft-bone interface characterized by Sharpey-like fibres. Qualitative differences in tendon remodelling were seen between the two groups, with greater crimp-like organization and more aligned collagen fibres seen with Endobutton fixation. One graft rupture occurred in the cross-pin group, which histologically showed low collagen organization. Conclusion. Decellularized pSFT xenograft remodels into a ligament-like structure after 12 weeks and regenerates an indirect-type insertion with Sharpey-like fibres. No adverse inflammatory reaction was observed. Cortical suspensory femoral fixation was associated with more enhanced graft remodelling and earlier functional recovery when compared with the stiffer cross-pin fixation


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 474 - 480
1 May 2023
Inclan PM Brophy RH

Anterior cruciate ligament (ACL) graft failure from rupture, attenuation, or malposition may cause recurrent subjective instability and objective laxity, and occurs in 3% to 22% of ACL reconstruction (ACLr) procedures. Revision ACLr is often indicated to restore knee stability, improve knee function, and facilitate return to cutting and pivoting activities. Prior to reconstruction, a thorough clinical and diagnostic evaluation is required to identify factors that may have predisposed an individual to recurrent ACL injury, appreciate concurrent intra-articular pathology, and select the optimal graft for revision reconstruction. Single-stage revision can be successful, although a staged approach may be used when optimal tunnel placement is not possible due to the position and/or widening of previous tunnels. Revision ACLr often involves concomitant procedures such as meniscal/chondral treatment, lateral extra-articular augmentation, and/or osteotomy. Although revision ACLr reliably restores knee stability and function, clinical outcomes and reoperation rates are worse than for primary ACLr.

Cite this article: Bone Joint J 2023;105-B(5):474–480.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 997 - 1003
1 Jul 2015
Papanagiotou M Dailiana ZH Karachalios T Varitimidis S Vlychou M Hantes M Malizos KN

We report the outcome of 84 nonunions involving long bones which were treated with rhBMP-7, in 84 patients (60 men: 24 women) with a mean age 46 years (18 to 81) between 2003 and 2011. The patients had undergone a mean of three previous operations (one to 11) for nonunion which had been present for a mean of 17 months (4 months to 20 years). The nonunions involved the lower limb in 71 patients and the remainder involved the upper limb. A total of 30 nonunions were septic. Treatment was considered successful when the nonunion healed without additional procedures. The relationship between successful union and the time to union was investigated and various factors including age and gender, the nature of the nonunion (location, size, type, chronicity, previous procedures, infection, the condition of the soft tissues) and type of index procedure (revision of fixation, type of graft, amount of rhBMP-7) were analysed. The improvement of the patients’ quality of life was estimated using the Short Form (SF) 12 score. A total of 68 nonunions (80.9%) healed with no need for further procedures at a mean of 5.4 months (3 to 10) post-operatively. Multivariate logistic regression analysis of the factors affecting union suggested that only infection significantly affected the rate of union (p = 0.004).Time to union was only affected by the number of previous failed procedures (p = 0.006). An improvement of 79% and 32.2% in SF-12 physical and mental score, respectively, was noted within the first post-operative year. Rh-BMP-7 combined with bone grafts, enabled healing of the nonunion and improved quality of life in about 80% of patients. Aseptic nonunions were much more likely to unite than septic ones. The number of previous failed operations significantly delayed the time to union. Cite this article: Bone Joint J 2015;97-B:997–1003


Bone & Joint Research
Vol. 7, Issue 5 | Pages 327 - 335
1 May 2018
Sato Y Akagi R Akatsu Y Matsuura Y Takahashi S Yamaguchi S Enomoto T Nakagawa R Hoshi H Sasaki T Kimura S Ogawa Y Sadamasu A Ohtori S Sasho T

Objectives. To compare the effect of femoral bone tunnel configuration on tendon-bone healing in an anterior cruciate ligament (ACL) reconstruction animal model. Methods. Anterior cruciate ligament reconstruction using the plantaris tendon as graft material was performed on both knees of 24 rabbits (48 knees) to mimic ACL reconstruction by two different suspensory fixation devices for graft fixation. For the adjustable fixation device model (Socket group; group S), a 5 mm deep socket was created in the lateral femoral condyle (LFC) of the right knee. For the fixed-loop model (Tunnel group; group T), a femoral tunnel penetrating the LFC was created in the left knee. Animals were sacrificed at four and eight weeks after surgery for histological evaluation and biomechanical testing. Results. Histologically, both groups showed a mixture of direct and indirect healing patterns at four weeks, whereas only indirect healing patterns were observed in both groups at eight weeks. No significant histological differences were seen between the two groups at four and eight weeks in the roof zone (four weeks, S: mean 4.8 . sd. 1.7, T: mean 4.5 . sd. 0.5, p = 0.14; eight weeks, S: mean 5.8 . sd. 0.8, T: mean 4.8 . sd. 1.8, p = 0.88, Mann-Whitney U test) or side zone (four weeks, S: mean 5.0 . sd. 1.2, T: mean 4.8 . sd. 0.4, p = 0.43; eight weeks, S: mean 5.3 . sd. 0.8,T: mean 5.5 . sd. 0.8, p = 0.61, Mann-Whitney U test) . Similarly, no significant difference was seen in the maximum failure load between group S and group T at four (15.6 . sd. 9.0N and 13.1 . sd. 5.6N) or eight weeks (12.6 . sd. 3.6N and 17.1 . sd. 6.4N, respectively). Conclusion. Regardless of bone tunnel configuration, tendon-bone healing after ACL reconstruction primarily occurred through indirect healing. No significant histological or mechanical differences were observed between adjustable and fixed-loop femoral cortical suspension methods. Cite this article: Y. Sato, R. Akagi, Y. Akatsu, Y. Matsuura, S. Takahashi, S. Yamaguchi, T. Enomoto, R. Nakagawa, H. Hoshi, T. Sasaki, S. Kimura, Y. Ogawa, A. Sadamasu, S. Ohtori, T. Sasho. The effect of femoral bone tunnel configuration on tendon-bone healing in an anterior cruciate ligament reconstruction: An animal study. Bone Joint Res 2018;7:327–335. DOI: 10.1302/2046-3758.75.BJR-2017-0238.R2


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 997 - 1008
1 Aug 2022

Aims

The aim of this study was to describe the management and associated outcomes of patients sustaining a femoral hip periprosthetic fracture (PPF) in the UK population.

Methods

This was a multicentre retrospective cohort study including adult patients who presented to 27 NHS hospitals with 539 new PPFs between 1 January 2018 and 31 December 2018. Data collected included: management strategy (operative and nonoperative), length of stay, discharge destination, and details of post-treatment outcomes (reoperation, readmission, and 30-day and 12-month mortality). Descriptive analysis by fracture type was performed, and predictors of PPF management and outcomes were assessed using mixed-effects logistic regression.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 188 - 188
1 Mar 2010
Parker D Patel S Beatty K Tripovich J Coolican M
Full Access

Anterior Cruciate Ligament (ACL) reconstruction is a well established procedure for restoration of stability following ACL rupture. Several methods exist for fixation of soft tissue grafts on the tibia, without general agreement about the optimal method. This study compared two different methods of tibial fixation using hamstring grafts in ACL reconstruction. 113 consecutive patients were randomized into two groups at the time of surgery. In group one, fixation was with a metal interference screw (RCI) and staples and in group two, with a polyethylene screw and sheath (Intrafix). Evaluation of outcomes was conducted using KT-1000 arthrometer, Lysholm, IKDC subjective and Mohtadi scores. 7 reinjuries occurred within the time frame of the study, mostly related to sporting injuries, with 5 in group 2. 81% of remaining participants were successfully followed at 2 years post surgery. No significant difference in mean KT-1000 side-to-side measurements was found between groups at an average follow-up of 30 months (1.5 ± 1.9mm and 1.8 ± 1.9mm, respectively; p > 0.05). The mean Lysholm score for group one was 65.2 ± 15.5 preoperatively and 90.8 ± 9.5 postoperatively; for group two these scores were 62.0 ± 20.7 preoperatively and 88.8 ± 14.3 postoperatively. This improvement in scores after surgery was similar for both groups and was not significantly different between groups (p > 0.05). Both the IKDC subjective and Mohtadi scores showed significant (p < 0.05) improvements postoperatively compared with pre-operatively but no significant difference between fixation groups. There were no significant differences between the two groups for any outcome value, with both methods of graft fixation producing good results. The newer Intra-fix device had a higher reinjury rate but this was not significantly different from the screw and staple fixation, and on all other outcome measures the Intrafix device was equivalent to an interference screw and staples for tibial-sided graft fixation in ACL reconstruction


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 17 - 17
1 Nov 2016
Reeves J Athwal G Johnson J
Full Access

To evaluate the efficacy of using a novel button-suture construct in place of traditional screws to provide bone block fixation for the Latarjet procedure. Four paired cadaveric shoulders (n=8) were denuded, with the exception of the conjoint tendon on the coracoid, and were potted. A 15% anterior glenoid bone defect was simulated. Right and left specimens were randomised into two groups: double-screw versus quadruple-button Latarjet reconstruction techniques. A uniaxial mechanical actuator loaded the Latarjet reconstructed glenoid articular surface via a 47mm diameter metallic hemisphere. Cyclic loading between 50–200N was applied to the glenoid at a rate of 1Hz for 1000 cycles. Testing was repeated three times for conjoint tendon loads of 0N, 10N and 20N. The relative positions of three points on the inferior, central and superior edges of the coracoid bone fragment were optically tracked with respect to a glenoid coordinate system throughout testing. Screw and button constructs were compared on the basis of maximum relative displacement at these points (RINF, RCENT, RSUP). Statistical significance was assessed using a paired-samples t-test in SPSS. When conjoint tendon loading was not present the double screw and quadruple button constructs were not significantly (P>0.779) different (0N: RINF: 0.11 (0.05)mm vs. 0.12 (0.03)mm, RCENT: 0.12 (0.04)mm vs. 0.12 (0.03)mm, RSUP: 0.13 (0.04)mm vs. 0.12 (0.03)mm). Additionally, the double screw construct was not found to differ (P>0.062) from the quadruple button in terms of resultant coracoid displacement for all central and superior points, regardless of conjoint loading (10N: RCENT: 0.11 (0.03)mm vs. 0.19 (0.05)mm, RSUP: 0.11 (0.01)mm vs. 0.18 (0.04)mm; 20N: RCENT: 0.13 (0.01)mm vs. 0.30 (0.13)mm, RSUP: 0.13 (0.03)mm vs. 0.26 (0.14)mm). It was only for the inferior point with conjoint loading of 10N and 20N that the double screw construct began to produce significantly lower displacements than the quadruple button (10N: RINF: 0.11 (0.03)mm vs. 0.23 (0.05)mm, P=0.047; 20N: RINF: 0.12 (0.02)mm vs. 0.39 (0.15)mm, P=0.026). The results of the screw and button constructs when conjoint tendon loading was absent suggest that the button may be a suitable substitute to the screw when the coracoid is used as a bone block. Due to the small resultant displacements (max: screw = 0.19mm, button = 0.52mm), it is suggested that buttons may also act as a substitute to screws for Latarjet procedures, provided conjoint tendon overloading is minimised during the post-operative graft healing period. These in-vitro results support the in-vivo results of Boileau et al (2015) that demonstrated the suture-button technique to be an excellent alternative to screw fixation Latarjet, with graft healing in 91% of their subjects


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 549 - 558
1 May 2022
Duncumb JW Robinson PG Williamson TR Murray IR Campbell D Molyneux SG Duckworth AD

Aims

The purpose of this systematic review was to determine the rates of union for vascularized versus non-vascularized grafting techniques in the operative management of scaphoid nonunion. Secondary aims were to determine the effect of the fixation techniques used, the source of grafting, as well as the influence of fracture location (proximal pole) and avascular necrosis (AVN).

Methods

A search of PubMed, MEDLINE, and Embase was performed in June 2021 using the Preferred Reporting Items for Systematic Review and Meta-Analyses statement and registered using the PROSPERO International prospective register of systematic reviews. The primary outcome was union rate.