Aims. Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model. Methods. We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation. Results. Multivariate Fine-Gray regression analyses revealed different hazards for each Henderson failure mode: percentage of
Aims. We have evaluated the survivorship, outcomes, and failures of an interlocking, reconstruction-mode stem-sideplate implant used to preserve the native hip joint and achieve proximal fixation when there is little residual femur during large endoprosthetic reconstruction of the distal femur. Methods. A total of 14 patients underwent primary or revision reconstruction of a large femoral defect with a short remaining proximal femur using an interlocking, reconstruction-mode stem-sideplate for fixation after oncological distal femoral and diaphyseal resections. The implant was attached to a standard endoprosthetic reconstruction system. The implant was attached to a standard endoprosthetic reconstruction system. None of the femoral revisions were amenable to standard cemented or uncemented stem fixation. Patient and disease characteristics, surgical history, final ambulatory status. ,. and Musculoskeletal Tumor Society (MSTS) score were recorded. The percentage of proximal femur remaining was calculated from follow-up radiographs. Results. All 14 at-risk native hip joints were preserved at a mean final follow-up of 6.0 years (SD 3.7), despite a short residual femur, often after proximal osteotomies through the lesser trochanter. Overall, 13 of 14 stems had long-term successful fixation. Eight patients required no reoperation. Three patients required reoperation due to implant-related issues, and three patients required reoperation for wound healing problems or infection. There were no dislocations or fractures. At final follow-up the mean MSTS score was 24.9 (SD 4.1). Nine patients required no ambulation aids, and only one had a Trendelenburg gait. Conclusion. This interlocking, reconstruction-mode stem-sideplate reliably preserves native hip joint anatomy and function after large
The aim of this study was to investigate the safety and efficacy of 3D-printed modular prostheses in patients who underwent joint-sparing limb salvage surgery (JSLSS) for malignant femoral diaphyseal bone tumours. We retrospectively reviewed 17 patients (13 males and four females) with femoral diaphyseal tumours who underwent JSLSS in our hospital.Aims
Methods
For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis. We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan.Aims
Methods
Dislocation of the hip remains a major complication after periacetabular tumour resection and endoprosthetic reconstruction. The position of the acetabular component is an important modifiable factor for surgeons in determining the risk of postoperative dislocation. We investigated the significance of horizontal, vertical, and sagittal displacement of the hip centre of rotation (COR) on postoperative dislocation using a CT-based 3D model, as well as other potential risk factors for dislocation. A total of 122 patients who underwent reconstruction following resection of periacetabular tumour between January 2011 and January 2020 were studied. The risk factors for dislocation were investigated with univariate and multivariate logistic regression analysis on patient-specific, resection-specific, and reconstruction-specific variables.Aims
Methods
Aim. To compare the functional outcome of proximal femoral reconstruction using endoprosthetic replacement and hip arthrodesis using a vascularised fibular graft. Material and Methods. The study included thirty-five patients who had proximal femoral reconstruction following resection of a malignant bone tumour. Patients were divided into 2 groups according to the reconstructive modality used. Group 1 (15 patients) reconstructed by hip arthrodesis using a vascularised fibular graft. Group 2 (20 patients) reconstructed by endoprosthesis. The mean age of group I was 14.9 years (range, 7-25). 8 patients had Ewing's sarcoma, 5 osteogenic sarcoma, and 2 chondrosarcoma. In group 2, the mean age was 35 years (range, 14-61). Eight patients had osteogenic sarcoma, 2 chondrosarcoma, 2 Ewing's sarcoma, 1 lymphoma, 1 MFH, 1 synovial sarcoma, 1 parosteal osteosarcoma, and 4 metastatic carcinomas. Results. In group 1 failure of the fixation occurred in two patients, and deep infection developed in one patient. These patients were managed with revision of internal fixation and debridement respectively. The mean MSTS functional score was 87% (range 70 – 96%) at the time of the latest follow-up (mean = 64 months). The average limb length discrepancy was 2 cm (range 1 to 4). In group 2, two patients developed deep infection, one patient had a dislocation, and one had loosening of the implant with a re-operation rate of 20%. After a mean follow up of 49.1 months, the mean MSTS functional score was 79% (range 60 – 93%). Conclusion. The functional outcome of hip arthrodesis using a vascularized fibular graft is comparable to endoprosthetic replacement after proximal
We undertook a retrospective review of 33 patients who underwent total femoral endoprosthetic replacement as limb salvage following excision of a malignant bone tumour. In 22 patients this was performed as a primary procedure following total
There is an increased risk of dislocation of the hip after the resection of a periacetabular tumour and endoprosthetic reconstruction of the defect in the hemipelvis. The aim of this study was to determine the rate and timing of dislocation and to identify its risk factors. To determine the dislocation rate, we conducted a retrospective single-institution study of 441 patients with a periacetabular tumour who had undergone a standard modular hemipelvic endoprosthetic reconstruction between 2003 and 2019. After excluding ineligible patients, 420 patients were enrolled. Patient-specific, resection-specific, and reconstruction-specific variables were studied using univariate and multivariate analyses.Aims
Methods
Aims
Patients and Methods
Pelvic reconstruction after the resection of a tumour around
the acetabulum is a challenging procedure due to the complex anatomy
and biomechanics. Several pelvic endoprostheses have been introduced,
but the rates of complication remain high. Our aim was to review
the use of a stemmed acetabular pedestal cup in the management of
these patients. The study involved 48 patients who underwent periacetabular reconstruction
using a stemmed pedestal cup (Schoellner cup; Zimmer Biomet Inc.,
Warsaw, Indiana) between 2000 and 2013. The indications for treatment included
a primary bone tumour in 27 patients and metastatic disease in 21
patients. The mean age of the patients at the time of surgery was
52 years (16 to 83).Aims
Patients and Methods
The aims of this study were to analyse the long-term outcome
of vascularised fibular graft (VFG) reconstruction after tumour
resection and to evaluate the usefulness of the method. We retrospectively reviewed 49 patients who had undergone resection
of a sarcoma and reconstruction using a VFG between 1988 and 2015.
Their mean follow-up was 98 months (5 to 317). Reconstruction was
with an osteochondral graft (n = 13), intercalary graft (n = 12),
inlay graft (n = 4), or resection arthrodesis (n = 20). We analysed
the oncological and functional outcome, and the rate of bony union
and complications.Aims
Patients and Methods
We determined the efficacy of a devitalised autograft
(n = 13) and allograft (n = 16) cortical strut bone graft combined
with long-stem endoprosthetic reconstruction in the treatment of
massive tumours of the lower limb. A total of 29 patients (18 men:11
women, mean age 20.1 years (12 to 45) with a ratio of length of
resection to that of the whole prosthesis of >
50% were treated
between May 2003 and May 2012. The mean follow-up was 47 months
(15 to 132). The stem of the prosthesis was introduced through bone
graft struts filled with cement, then cemented into the residual
bone. Bone healing was achieved in 23 patients (86%). The mean Musculoskeletal
Tumour Society functional score was 85% (57 to 97). The five-year
survival rate of the endoprostheses was 81% (95% confidence intervals
67.3 to 92.3). The mean length of devitalised autografts and allografts
was 8.6 cm (5 to 15), which increased the ratio of the the length
of the stem of the prosthesis to that of the whole length of the
prosthesis from a theoretical 35% to an actual 55%. Cortical strut bone grafting and long-stem endoprosthetic reconstruction
is an option for treating massive segmental defects following resection
of a tumour in the lower limb. Patients can regain good function
with a low incidence of aseptic loosening. The strut graft and the
residual bone together serve as a satisfactory bony environment
for a revision prosthesis, if required, once union is achieved. Cite this article:
Guidelines for the management of patients with metastatic bone
disease (MBD) have been available to the orthopaedic community for
more than a decade, with little improvement in service provision
to this increasingly large patient group. Improvements in adjuvant
and neo-adjuvant treatments have increased both the number and overall
survival of patients living with MBD. As a consequence the incidence
of complications of MBD presenting to surgeons has increased and
is set to increase further. The British Orthopaedic Oncology Society
(BOOS) are to publish more revised detailed guidelines on what represents
‘best practice’ in managing patients with MBD. This article is designed
to coincide with and publicise new BOOS guidelines and once again
champion the cause of patients with MBD. A series of short cases highlight common errors frequently being
made in managing patients with MBD despite the availability of guidelines.Objectives
Methods
We describe a retrospective review of 38 cases of reconstruction following resection of the metaphysiodiaphysis of the lower limb for malignant bone tumours using free vascularised fibular grafts. The mean follow-up was for 7.6 years (0.4 to 18.4). The mean Musculoskeletal Tumor Society score was 27.2 (20 to 30). The score was significantly higher when the graft was carried out in a one-stage procedure after resection of the tumour rather than in two stages. Bony union was achieved in 89% of the cases. The overall mean time to union was 1.7 years (0.2 to 10.3). Free vascularised fibular transfer is a major operation with frequent, but preventable, complications which allows salvage of the limb with satisfactory functional results.
We undertook a cemental unipolar proximal femoral endoprosthetic replacement in 131 patients with a mean age of 50 years (2 to 84). Primary malignant tumours were present in 54 patients and 67 had metastatic disease. In addition, eight patients had either lymphoma or myeloma and two had non-oncological disorders. The mean follow-up was 27 months (0 to 180). An acetabular revision was required later in 14 patients, 12 of whom had been under the age of 21 years at the time of insertion of their original prosthesis. The risk of acetabular revision in patients over 21 years of age was 8% at five years compared with 36% in those aged under 21 years. All the unipolar hips in this younger age group required revision within 11 years of the initial operation. We conclude that unipolar replacement should not be used in younger patients and should be avoided in patients with a life expectancy of more than five years.
A retrospective analysis was performed of eight patients with an open triradiate cartilage, who underwent resection for osteosarcoma and reconstruction of the proximal femur with a hemiarthroplasty, in order to identify changes of acetabular development. An analysis of the centre-edge angle, teardrop-to-medial prosthesis distance, superior joint space, teardrop-to-superior prosthesis distance, degree of lateral translation, and arthritic changes, was performed on serial radiographs. The median age at the time of the initial surgery was 11 years (5 to 14). All patients developed progressive superior and lateral migration of the prosthetic femoral head. Following hemiarthroplasty in the immature acetabulum, the normal deepening and enlargement of the acetabulum is arrested. The degree of superior and lateral migration of the prosthetic head depends on the age at diagnosis and the length of follow-up.
We report our early experience with the use of a non-invasive distal femoral expandable endoprosthesis in seven skeletally immature patients with osteosarcoma of the distal femur. The patients had a mean age of 12.1 years (9 to 15) at the time of surgery. The prosthesis was lengthened at appropriate intervals in outpatient clinics, without anaesthesia, using the principle of electromagnetic induction. The patients were functionally evaluated using the Musculoskeletal Tumour Society scoring system. The mean follow-up was 20.2 months (14 to 30). The prostheses were lengthened by a mean of 25 mm (4.25 to 55) and maintained a mean knee flexion of 110° (100° to 120°). The mean Musculoskeletal Tumour Society score was 68% (11 to 29). Complications developed in two patients; one developed a flexion deformity of 25° at the knee joint, which was subsequently overcome and one died of disseminated disease. The early results from patients treated with this device have been encouraging. The implant avoids multiple surgical procedures, general anaesthesia and assists in maintaining leg-length equality.