Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 90 - 90
4 Apr 2023
Sharma M Khanal P Patel N Patel A
Full Access

To investigate the utility of virtual reality (VR) simulators in improving surgical proficiency in Orthopaedic trainees for complex procedures and techniques. Fifteen specialty surgeons attending a London Orthopaedic training course were randomised to either the VR (n = 7) or control group (n = 8). All participants were provided a study pack comprising an application manual and instructional video for the Trochanteric Femoral Nail Advanced (TFNA) procedure. The VR group underwent additional training for TFNA using the DePuy Synthes (Johnson and Johnson) VR simulator. All surgeons were then observed applying the TFNA in a Sawbones model and assessed by a blinded senior consultant using three metrics: time to completion, 22-item procedure checklist and 5-point global assessment scale. Participant demographics for the VR and control groups were similar in context of age (mean [SD]: VR group, 31.0 [2.38] years; control group, 30.6 [2.39] years), gender (VR group, 5 [71%] men; control group, 8 [100%] men) and prior experience with TFNA (had applied TFNA as primary surgeon: VR group, 6 [86%]; control group, 7 [88%]). Although statistical significance was not reached, the VR group, on average, outperformed the control group on all three metrics. They completed the TFNA procedure faster (mean [SD]: 18.2 [2.16] minutes versus 19.78 [1.32] minutes; p<0.189), performed a greater percentage of steps correctly (79% versus 66%; p<0.189) and scored a higher percentage on the global assessment scale (75% versus 65%; p<0.232). VR simulators offer a safe and accessible means for Orthopaedic trainees to prepare for and supplement their theatre-based experience. It is vital, therefore, to review and validate novel simulation-based systems and in turn facilitate their improvement. We intend to increase our sample size and expand this preliminary study through a second upcoming surgical course for Orthopaedic trainees in London


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 96 - 96
1 Mar 2021
Abood A Rahbek O Moeller-Madsen B Kold S
Full Access

The use of retrograde femoral intramedullary nails in children for deformity correction is controversial. It is unknown if the injury to the central part of the growth plate results in premature bony union, leading to limb deformities or discrepancies. The aim of this study was to assess physeal healing and bone growth after insertion of a retrograde femoral nail thorough the centre of the physis in a skeletally immature experimental porcine model. Eleven immature pigs were included in the study. One leg was randomised for operation with a retrograde femoral nail (diameter 10.7 mm), whilst the non-operated contralateral remained as control. All nails were inserted centrally in coronal and sagittal plane under fluoroscopic guidance, and the nails spanned the physis. The nails were removed at 8 weeks. Both femora in all animals underwent MRI at baseline (pre-operatively), 8 weeks (after nail removal) and 16 weeks (before euthanasia). Femoral bone length was measured at 5 sites (anterior, posterior, central, lateral and medial) using 3d T1-weighted MRI. Growth was calculated after 8 weeks (growth with nail) and 16 weeks (growth without nail). Physeal cross-sectional area and percentage violated by the nail was determined on MRI. Operated side was compared to non-operated. Corresponding 95% confidence intervals were calculated. No differences in axial growth were observed between operated and non-operated sides. Mean growth difference was 0,61 mm [−0,78;2,01] whilst the nail was inserted into the bone and 0,72 mm [−1,04;1,65] after nail removal. No signs of angular bone deformities were found when comparing operated side to non-operated side. No premature bony healing at the physis occurred. Histology confirmed fibrous healing. Mean physeal violation was 5.72% [5.51; 5.93] by the femoral nail. The insertion of a retrograde femoral nail through the centre of an open physis might be a safe procedure with no subsequent growth arrest. However, experiments assessing the long term physeal healing and growth are needed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 70 - 70
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Carvalho R
Full Access

Renal Osteodystrophy is a type of metabolic bone disease characterized by bone mineralization deficiency due to electrolyte and endocrine abnormalities. Patients with chronic kidney disease (CKD) are more likely to experience falls and fractures due to renal osteodystrophy and the high prevalence of risk factors for falls. Treatment involves medical management to resolve the etiology of the underlying renal condition, as well as management (and prevention) of pathological fractures. A 66-year-old female patient, with severe osteoporosis and chronic kidney disease undergoing haemodialysis, has presented with multiple fractures along the years. She was submitted to bilateral proximal femoral nailing as fracture treatment on the left and prophylactically due to pathological bone injury on the right, followed by revision of the left nail with a longer one after varus angulation and fracture distal to the nail extremity. Meanwhile, the patient suffered a pathological fracture of the radial and cubital diaphysis and was submitted to conservative treatment with cast, with consolidation of the fracture. Posteriorly, she re-fractured these bones after a fall and repeated the conservative treatment. Clinical management: There is a multidisciplinary approach to manage the chronic illness of the patient, including medical management to resolve the etiology and consequences of her chronic kidney disease, pain control, conservative or surgical fracture management and prevention of falls. The incidence of chronic renal disease is increasing and the patients with this condition live longer than previously and are more physically active. Thus, patients may experience trauma as a direct result of increased physical activity in a setting of weakened pathologic bone. Their quality of life is primarily limited by musculoskeletal problems, such as bone pain, muscle weakness, growth retardation, and skeletal deformity. A multidisciplinary approach is required to treat these patients, controlling their chronic diseases, managing fractures and preventing falls


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 74 - 74
1 Dec 2020
Köse N Bayrak ÇH Köse AA Sevencan A Toktaş AG Doğan A
Full Access

Orthopaedic and trauma implant related infection remains one of the major complications that negatively impact clinical outcome and significantly increase healthcare expenditure. Hydroxyapatite has been used for many years to increase implant osseointegration. Silver has been introduced into hydroxyapatite as an antimicrobial coating for orthopedic implants. This surface coatings can both increase tissue compatibility and prevent implant-related infections. We examined infection markers and blood silver values, liver and kidney function tests of 30 patients with of three groups of orthopedic implants, external fixators, intramedullary nails and hip replacements, coated with Ag + ion doped CaP based ceramic powder to determine safety and effectiveness of this dual-function coating. During 1 year follow-up, the pin sites were observed at the external fixator group, and wound areas for the proximal femoral nail and hip arthroplasty group at regular intervals. In addition, liver and kidney function tests, infection markers and blood silver values were checked in patients. In the external fixator group, only 4 out of 91 pin sites (%4.39) were infected. The wound areas healed without any problem in patients with proximal femoral nails and hip arthroplasty. There was no side effect suggesting silver toxicity such as systemic toxic side effect or argyria in any patient and blood silver level did not increase. Compared to similar patient groups in the literature, much lower infection rates were obtained (p = 0.001), and implant osseointegration was good. In patients with chronic infection, the implants were applied acutely after removing the primary implant and with simple debridement. Unlike other silver coating methods, silver was trapped in hydroxyapatite crystals in the ionic form, which is released from the coating during the process of osseointegration, thus, the silver was released into the systemic circulation gradually that showed antibacterial activity locally. We conclude that the use of orthopedic implants with a silver ion added calcium phosphate-based special coating is a safe method to prevent the implant-related infection. This work was supported by TUBİTAK Project Number 315S101


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 62 - 62
1 May 2012
Chan K Wong J Thompson N
Full Access

INTRODUCTION. Intramedullary nail fixation has been used for successful treatment of long bone fracture such as humerus, tibia and femur. We look at the experience of our trauma unit in treating long bone fracture using the AO approved Expert femoral/tibial nail and proximal femoral nail antirotation (PFNA). We look at the union and complication rates in patients treated with AO approved nailing system for pertrochanteric, femoral and tibial shaft fracture. METHODS. We carried out retrospective case notes review of patients that underwent femoral and tibial nailing during the period of study- October 2007 to August 2009. All patients were treated using the AO approved nailing system. We identified all trauma patients that underwent femoral and tibial nailing through the trauma register. Further information was then obtained by going through medical notes and reviewing all followed-up X-rays stored within the online radiology system. RESULTS. 149 patients, 85 male and 64 female were included into the study. 150 procedures were carried out during period of study as 1 patient underwent conversion of lateral entry femoral nail to PFNA due to refracture. Patients' age ranged from 14-96 with mean of 55. 140 patients had isolated long bone fracture (either femur or tibia) compared to 9 patients with multiple bone fractures. Our unit performed 64 Expert tibial nail, 36 PFNA, 31 Expert lateral entry femoral nail and 19 Expert retrograde femoral nail during period of study. 13 patients treated with intramedullary nail sustained open fracture, 9 of them were compound tibial fracture compared to 4 compound femoral fractures. All patients were followed-up between 2 to 24 months or until death. 9 out of 17 patients that died in this study had diagnosis of tumour. Complication rates were 17% for Expert tibial nail (1 patient with valgus deformity, peroneal nerve palsy and delayed union, 3 with delayed union, 4 with broken locking screw, 2 with wound infection and 1 with abscess over wound site), 4% for lateral/retrograde femoral nail (1 each for pulmonary embolism and broken locking screw) and 4% for PFNA (1 each for delayed union and deep vein thrombosis). The overall complication rates were 10% from this study. DISCUSSION & CONCLUSIONS. We conclude that the AO approved nailing system used for treating pertrochanteric, femoral and tibial fractures were effective with high union rate. The overall complication rates were 10% from this study. Complication rates for tibial nail were as high as 17% compared to 4% for femoral nail or PFNA. The complication rates for PFNA in our study were lower compared to 29% in PFN that was reported in one literature


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 104 - 104
1 Jan 2017
Kan C Chan Y Selvaratnam V Donnachie N
Full Access

The femur is a common site for skeletal bony metastases. The aim of this study is to evaluate the outcomes of femoral intramedullary nailing in prophylactic versus therapeutic treatment in femoral metastases. All femoral nails between April 2011 and November 2015 at a district general hospital were assessed. Intramedullary nailing performed for prophylactic or therapeutic management were included. Outcomes include mortality, survival time and length of stay in hospital. A total of 40 cases were included. In the prophylactic group there were 25 patients and in the therapeutic group there were 15 patients. In the prophylactic group, mean age was 70 years (range 41–91); male to female ratio is 23:17 and 26 patients of this group was deceased. In the therapeutic group, mean age was 76 years (range 56–92); male to female ratio 15:10 and 10 patients were deceased in this group. The most common primary was prostate carcinoma followed by breast carcinoma. In the prophylactic group, mean survival was 25 weeks (range 2–147) and in the therapeutic group mean survival was 20 weeks (range 2–39). The length of stay was 21 days (range 3–80) in the prophylactic group and 28 days (range 7–63) in the therapeutic group. Femoral nailing for metastases helps improve quality of life and we observed a mean survival time of 20–25 weeks postoperatively in both therapeutic and prophylactic nailing


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 82 - 82
1 Dec 2020
Zderic I Breceda A Schopper C Schader J Gehweiler D Richards G Gueorguiev B Sands A
Full Access

It is common belief that consolidated intramedullary nailed trochanteric femur fractures can result in secondary midshaft or supracondylar fractures, involving the distal screws, when short or long nails are used, respectively. In addition, limited data exists in the literature to indicate when short or long nails should be selected for treatment. The aim of this biomechanical cadaveric study was to investigate short versus long Trochanteric Femoral Nail Advanced (TFNA) fixation in terms of construct stability and generation of secondary fracture pattern following trochanteric fracture consolidation. Eight intact human cadaveric femur pairs were assigned to 2 groups of 8 specimens each for nailing using either short or long TFNA with blade as head element. Each specimen was first biomechanically preloaded at 1 Hz over 2000 cycles in superimposed synchronous axial compression to 1800 N and internal rotation to 11.5 Nm. Following, internal rotation to failure was applied over an arc of 90° within 1 second under 700 N axial load. Torsional stiffness, torque at failure, angle at failure and energy at failure were evaluated. Fracture patterns were analyzed. Outcomes in the groups with short and long nails were 9.7±2.4 Nm/° and 10.2±2.9 Nm/° for torsional stiffness, 119.8±37.2 Nm and 128.5±46.7 Nm for torque at failure, 13.5±3.5° and 13.4±2.6° for angle at failure, and 887.5±416.9 Nm° and 928.3±461.0 Nm° for energy at failure, respectively, with no significant differences between them, P≥0.167. Fractures through the distal locking screw occurred in 5 and 6 femora instrumented with short and long nails, respectively. Fractures through the lateral entry site of the head element were detected in 3 specimens within each group. For short nails, fractures through the distal shaft region, not interfacing with the implant, were detected in 3 specimens. From biomechanical perspective, the risk of secondary peri-implant fracture after intramedullary nailed trochanteric fracture consolidation is similar when using short or long TFNA. Moreover, for both nail versions the fracture pattern does not unexceptionally involve the distal locking screw


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 21 - 21
1 Nov 2018
Gbejuade H Elsakka M
Full Access

Surgical training in the UK is under increasing pressure with a high demand for service provision. This raises concerns about the resultant negative impact this is having on training opportunities for surgical trainees in theatre due to a high demand for surgical procedures to be performed expediently by consultants. This is due to the assumption that trainee take significantly longer time to operate in theatre and thus result in a slow progress of theatre lists. Our study evaluated the differences in operative time between orthopaedic trainees and orthopaedic consultants, as well as provide realistic timings for each stage encompassed within the entire duration a patient is in theatre. From our trauma unit electronic theatre database, we retrospectively collected data for six Joint Committee of Surgical Training (JCST) mandatory procedures. Information collected included patients' ASA grading, total surgical time and grade of surgeons. A total of 956 procedures were reviewed: 71.8% hip procedures, 14.2% intramedullary nail fixations and 14.2% ankle fixations. 46.2% and 53.8% of the procedures were performed by consultants and trainees as first surgeon, respectively. On average, consultants were found to be 13 minutes quicker in performing the hip procedures and this difference was found to be statically significant (p < 0.05). However, trainees were found to be quicker in performing intramedullary femoral nailings and simple ankle fixations, but consultant were faster at performing intramedullary tibial nailings and complex ankle fixations. However, the differences were not found to be statistically significant (p > 0.05)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 54 - 54
1 May 2017
Roberton A Walker R Perera S Shah Z Bankes M George M
Full Access

Background. A dedicated referral pathway for patients with bony metastases was introduced at Guy's and St Thomas’ Hospitals (GSTT) in 2009. The aim was to facilitate prompt, consultant-led decision-making and intervention for patients at risk of pathological fracture of long bones. Methods. We performed a clinical audit and service evaluation of the referral pathway through retrospective review of referrals over 3.5 years. Results. 75 patients referred from 7 different specialties, (34:41 male:female), mean age 64. 16 different types of primary cancer identified, the most common being breast (22/75). Location of metastasis was most commonly the femur (59/75). 24 patients underwent surgery, with femoral nail the most common procedure (13/24). Patients in the surgery group were younger, with higher Mirel's score, less visceral metastases and survived longer after surgery than patients treated non-operatively. Median referral-clinic time was 10 days and referral-surgery time was 14 days. Conclusions. Our data demonstrate the importance of this service and the growing demand. We have updated trust guidelines and improved our referral process through GSTT's Electronic Patient Record system. We have presented this data at local level to improve awareness and intend to reduce referral-clinical review time and have recently established a multidisciplinary meeting to improve patient outcome. Level of Evidence. 3


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 77 - 77
1 Apr 2017
Rashid M Aziz S Heydar S Fleming S Datta A
Full Access

Background. Radiation exposure remains a significant occupational hazard for Orthopaedic surgeons. There are no references values for trauma procedures performed with Image Intensifier (II). We aimed to determine and compare reference values for patient radiation exposure for common trauma operations, and to analyse the effect of surgeon grade on II usage. Methods. Data collected prospectively from 849 cases between 01/05/2013 and 01/10/2014 were analysed. Statistical analysis was performed to calculate reference values for dose area product (DAP), screening time (ST), and number of II images taken for common trauma procedures where n>9 (n=808). Results. Dynamic hip screw (DHS) fixation required significantly less radiation than proximal femoral nail (PFN) for intertrochanteric hip fractures for median DAP (668mG/cm2 vs 1040mG/cm2, p<0.001), ST (00:36 vs 00:48, p<0.001), and number of II images (65 vs 110, p<0.001). Radiation exposure was statistically significantly less when Consultant Orthopaedic surgeons were first surgeon compared to Staff grade doctors and Orthopaedic trainees for DAP (90.55mGy/cm2 vs 175.5mGy/cm2 vs 366.5mGy/cm2), screening time (00:26 vs 00:32 vs 00:36), and number of II images (49 vs 59 vs 66). Conclusions. We reported reference values for common trauma operations that are essential to enable monitoring of patient radiation exposure. PFN required greater radiation exposure than DHS for intertrochanteric hip fracture. Increased surgical experience lead to lower radiation exposure in trauma operations, which could be developed to assess trauma competence within surgical training. Level of evidence. III


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 356 - 361
1 Mar 1999
Giannoudis PV Smith RM Bellamy MC Morrison JF Dickson RA Guillou PJ

It has been suggested that reamed intramedullary nailing of the femur should be avoided in some patients with multiple injuries. We have studied prospectively the effect of femoral reaming on the inflammatory process as implicated in the pathogenesis of acute respiratory distress syndrome (ARDS) and multiple-organ failure (MOF). We studied changes in the levels of serum interleukin-6 (IL-6) (proinflammatory cytokine), neutrophil CD11b (C3) receptor expression (activated neutrophil adhesion molecule), serum soluble intracellular adhesion molecule (s-ICAM-1), serum soluble E-selectin (the soluble products of endothelial adhesion molecules) and plasma elastase (neutrophil protease) in a series of patients with femoral fractures treated by nailing. We have also compared reamed nailing with unreamed nailing. We found that the levels of serum IL-6 and elastase rose significantly during the nailing procedure indicating a measurable ‘second hit’. There was no clear response in leukocyte activation and no difference in the release of endothelial adhesion molecule markers. There was no significant difference between groups treated by reamed and unreamed nailing. Although clinically unremarkable, the one patient who died from ARDS was shown to be hyperstimulated after injury and again after nailing, suggesting the importance of an excessive inflammatory reaction in the pathogenesis of these serious problems. Our findings have shown that there is a second hit associated with femoral nailing and suggest that the degree of the inflammatory reaction may be important in the pathogenesis of ARDS and MOF


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 393 - 399
1 Mar 2008
Morley JR Smith RM Pape HC MacDonald DA Trejdosiewitz LK Giannoudis PV

We have undertaken a prospective study in patients with a fracture of the femoral shaft requiring intramedullary nailing to test the hypothesis that the femoral canal could be a potential source of the second hit phenomenon. We determined the local femoral intramedullary and peripheral release of interleukin-6 (IL-6) after fracture and subsequent intramedullary reaming.

In all patients, the fracture caused a significant increase in the local femoral concentrations of IL-6 compared to a femoral control group. The concentration of IL-6 in the local femoral environment was significantly higher than in the patients own matched blood samples from their peripheral circulation. The magnitude of the local femoral release of IL-6 after femoral fracture was independent of the injury severity score and whether the fracture was closed or open.

In patients who underwent intramedullary reaming of the femoral canal a further significant local release of IL-6 was demonstrated, providing evidence that intramedullary reaming can cause a significant local inflammatory reaction.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1274 - 1281
1 Sep 2014
Farhang K Desai R Wilber JH Cooperman DR Liu RW

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined.

The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded.

The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (sd 4.0) and 4.6 mm (sd 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (sd 4.6) and 6.4 mm (sd 4.6), respectively.

Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset.

Cite this article: Bone Joint J 2014;96-B:1274–81.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 865 - 874
1 Jul 2012
Mills LA Simpson AHRW

This review is aimed at clinicians appraising preclinical trauma studies and researchers investigating compromised bone healing or novel treatments for fractures. It categorises the clinical scenarios of poor healing of fractures and attempts to match them with the appropriate animal models in the literature.

We performed an extensive literature search of animal models of long bone fracture repair/nonunion and grouped the resulting studies according to the clinical scenario they were attempting to reflect; we then scrutinised them for their reliability and accuracy in reproducing that clinical scenario.

Models for normal fracture repair (primary and secondary), delayed union, nonunion (atrophic and hypertrophic), segmental defects and fractures at risk of impaired healing were identified. Their accuracy in reflecting the clinical scenario ranged greatly and the reliability of reproducing the scenario ranged from 100% to 40%.

It is vital to know the limitations and success of each model when considering its application.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 823 - 827
1 Jun 2006
White TO Clutton RE Salter D Swann D Christie J Robinson CM

The stress response to trauma is the summation of the physiological response to the injury (the ‘first hit’) and by the response to any on-going physiological disturbance or subsequent trauma surgery (the ‘second hit’).

Our animal model was developed in order to allow the study of each of these components of the stress response to major trauma. High-energy, comminuted fracture of the long bones and severe soft-tissue injuries in this model resulted in a significant tropotropic (depressor) cardiovascular response, transcardiac embolism of medullary contents and activation of the coagulation system. Subsequent stabilisation of the fractures using intramedullary nails did not significantly exacerbate any of these responses.