Advertisement for orthosearch.org.uk
Results 1 - 20 of 88
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1196 - 1201
1 Nov 2022
Anderson CG Brilliant ZR Jang SJ Sokrab R Mayman DJ Vigdorchik JM Sculco PK Jerabek SA

Aims

Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods.

Methods

In this study, 45 patients who underwent THA between February 2016 and February 2020 and had both a postoperative CT and EOS scan were included for evaluation. A fellowship-trained musculoskeletal radiologist and radiological technician measured femoral version for CT and 3D EOS, respectively. Comparison of values for each imaging modality were assessed for statistical significance.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 75 - 75
19 Aug 2024
Hieda Y Choe H Ike H Abe K Shimoda M Kumagai K Kobayashi N Inaba Y
Full Access

Dislocation is a serious complication to be avoided in total hip arthroplasty (THA) and its incidence risk increases in revision surgery. Combined anteversion (CA) of the cup and stem is a concept for appropriate implant positioning; however, the effect of functional changes in femoral rotation has not been well investigated. The aim of this study was to investigate whether functional CA, considering femoral rotation, is associated with dislocation in patients undergoing revision THA. Seventy-three patients who underwent revision THA and had at least one year of follow-up with pre- and postoperative supine CT imaging were included. Cup and stem were placed with a target combined angle of 37.3° using Widmer's formula. Anatomical and functional CA was calculated postoperatively using the following formula: Anatomical CA: cup anteversion + 0.7 × anatomical stem anteversion; Functional CA: cup anteversion + 0.7 × (anatomical stem anteversion + femoral rotation). Patient demographics, cup and stem angles, CA and their relationship to dislocation were statistically evaluated. Dislocation was observed in 12 patients. In these dislocated cases, there were no significant differences in cup angle, stem angle and anatomical CA compared to non-dislocated cases. However, dislocated cases showed significantly higher values of functional CA [52.7 ± 17.5° (range, 5.9–69.3) vs. 36.0 ± 12.5° (range, 8.6–68.8), p=0.009] and significant deviation from identical CA [17.3 ± 9.6° (range, 2.8–32) vs. 7.5 ± 7.1° (range, 0.1–28.7), p=0.010]. Functional CA considering femoral rotation was associated with dislocation in revision THA patients. This finding suggests that consideration of femoral rotation may be necessary for implant positioning in revision THA


Bone & Joint Open
Vol. 2, Issue 9 | Pages 757 - 764
1 Sep 2021
Verhaegen J Salih S Thiagarajah S Grammatopoulos G Witt JD

Aims. Periacetabular osteotomy (PAO) is an established treatment for acetabular dysplasia. It has also been proposed as a treatment for patients with acetabular retroversion. By reviewing a large cohort, we aimed to test whether outcome is equivalent for both types of morphology and identify factors that influenced outcome. Methods. A single-centre, retrospective cohort study was performed on patients with acetabular retroversion treated with PAO (n = 62 hips). Acetabular retroversion was diagnosed clinically and radiologically (presence of a crossover sign, posterior wall sign, lateral centre-edge angle (LCEA) between 20° and 35°). Outcomes were compared with a control group of patients undergoing PAO for dysplasia (LCEA < 20°; n = 86 hips). Femoral version was recorded. Patient-reported outcome measures (PROMs), complications, and reoperation rates were measured. Results. The mean Non-Arthritic Hip Score (NAHS) preoperatively was 58.6 (SD 16.1) for the dysplastic hips and 52.5 (SD 12.7) for the retroverted hips (p = 0.145). Postoperatively, mean NAHS was 83.0 (SD 16.9) and 76.7 (SD 17.9) for dysplastic and retroverted hips respectively (p = 0.041). Difference between pre- and postoperative NAHS was slightly lower in the retroverted hips (18.3 (SD 22.1)) compared to the dysplastic hips (25.2 (SD 15.2); p = 0.230). At mean 3.5 years’ follow-up (SD 1.9), one hip needed a revision PAO and no hips were converted to total hip arthroplasty (THA) in the retroversion group. In the control group, six hips (7.0%) were revised to THA. No differences in complications (p = 0.106) or in reoperation rate (p = 0.087) were seen. Negative predictors of outcome for patients undergoing surgery for retroversion were female sex, obesity, hypermobility, and severely decreased femoral anteversion. Conclusion. A PAO is an effective surgical intervention for acetabular retroversion and produces similar improvements when used to treat dysplasia. Femoral version should be routinely assessed in these patients and when extremely low (< 0°), as an additional procedure to address this abnormality may be necessary. Females with signs of hypermobility should also be consulted of the likely guarded improvement. Cite this article: Bone Jt Open 2021;2(9):757–764


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1615 - 1622
1 Dec 2015
Müller M Abdel MP Wassilew GI Duda G Perka C

The accurate reconstruction of hip anatomy and biomechanics is thought to be important in achieveing good clinical outcomes following total hip arthroplasty (THA). To this end some newer hip designs have introduced further modularity into the design of the femoral component such that neck­shaft angle and anteversion, which can be adjusted intra-operatively. The clinical effect of this increased modularity is unknown. We have investigated the changes in these anatomical parameters following conventional THA with a prosthesis of predetermined neck–shaft angle and assessed the effect of changes in the hip anatomy on clinical outcomes. . In total, 44 patients (mean age 65.3 years (standard deviation (. sd. ) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²) (. sd. 3.1)) underwent a pre- and post-operative three-dimensional CT scanning of the hip. The pre- and post-operative neck–shaft angle, offset, hip centre of rotation, femoral anteversion, and stem alignment were measured. Additionally, a functional assessment and pain score were evaluated before surgery and at one year post-operatively and related to the post-operative anatomical changes. The mean pre-operative neck–shaft angle was significantly increased by 2.8° from 128° (. sd.  6.2; 119° to 147°) to 131° (. sd. 2.1; 127° to 136°) (p = 0.009). The mean pre-operative anteversion was 24.9° (. sd. 8; 7.9 to 39.1) and reduced to 7.4° (. sd. 7.3; -11.6° to 25.9°) post-operatively (p < 0.001). The post-operative changes had no influence on function and pain. Using a standard uncemented femoral component, high pre- and post-operative variability of femoral anteversion and neck–shaft angles was found with a significant decrease of the post-operative anteversion and slight increase of the neck–shaft angles, but without any impact on clinical outcome. Cite this article: Bone Joint J 2015;97-B:1615–22


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 24 - 24
1 Jul 2020
Di Laura A Henckel J Belzunce M Hothi H Hart A
Full Access

Introduction

The achieved anteversion of uncemented stems is to a large extent limited by the internal anatomy of the bone. A better understanding of this has recently become an unmet need because of the increased use of uncemented stems.

We aimed to assess plan compliance in six degrees of freedom to evaluate the accuracy of PSI and guides for stem positioning in primary THAs.

Materials and Methods

We prospectively collected 3D plans generated from preoperative CTs of 30 consecutive THAs (17 left and 13 right hips), in 29 patients with OA, consisting of 16 males and 13 females (median age 68 years, range 46–83 years). A single CT-based planning system and cementless type of implant were used.

Post operatively, all patients had a CT scan which was reconstructed using state-of-the-art software solution: the plan and CT reconstruction models were

Outcome measures: 1) discrepancy between planned and achieved stem orientation angles Fig.2&3; 2) clinical outcome.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 11 - 11
1 Jun 2017
O'Connor J Rutherford M Hill J Beverland D Dunne N Lennon A
Full Access

Unknown femur orientation during X-ray imaging may cause inaccurate radiographic measurements. The aim of this study was to assess the effect of 3D femur orientation during radiographic imaging on the measurement of greater trochanter to femoral head centre (GT-FHC) distance.

Three-dimensional femoral shapes (n=100) of unknown gender were generated using a statistical shape model based on a training data of 47 CT segmented femora. Rotations in the range of 0° internal to 50° external and 50° of flexion to 0° of extension (at 10 degree increments) were applied to each femur. A ray tracing algorithm was then used to create 2D images representing radiographs of the femora in known 3D orientations. The GT-FHC distance was then measured automatically by identifying the femoral head, shaft axis and tip of greater trochanter.

Uniaxial rotations had little impact on the measurement with mean absolute error of 0.6 mm and 3.1 mm for 50° for pure external rotation and 50° pure flexion, respectively. Combined flexion and external rotation yielded more significant errors with 10° around each axis introducing a mean error of 3.6 mm and 20° showing an average error of 8.8 mm (Figure 1.). In the cohort we studied, when the femur was in neutral orientation, the tip of greater trochanter was never below the femoral head centre.

Greater trochanter to femoral head centre measurement was insensitive to rotations around a single axis (i.e. flexion or external rotation). Modest combined rotations caused the tip of greater trochanter to appear more distal in 2D and led to deviation from the true value. This study suggests that a radiograph with the greater trochanter appearing below femoral head centre may have been acquired with 3D rotation of the femur.

For any figures or tables, please contact the authors directly by clicking on ‘Info & Metrics’ above to access author contact details.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 10 - 10
2 May 2024
Amer M Smith C Kumar KHS Malviya A
Full Access

Adult hip dysplasia AHD is a complex 3D pathology of lateral coverage, version and/or volume and is often associated with increased femoral anteversion. The Mckibbin index MI is the combination of acetabular version AV and femoral version FV and is used as a measure of anterior hip Stability/ Impingement(1). The Bernese Periacetabular osteotomy PAO is a powerful tool in treating AHD, but it does not address FV. De-rotational femoral osteotomies FO increases risk of complications, operative time and might condemn the patient to Secondary osteotomies to balance the gait. We aim to investigate the effect of MI and FV on PROMs in patients undergoing PAO only. 593 PAOs identified on the Local Hip preservation registry between 01/2013 and 7/2023. PAOs for retroversion, residual Perthes and those combined with FO were excluded. Patients with no available PROMS at 2 years were excluded. Independent variables were collected from E-notes and imaging including MI and FV. A multiple linear regression analysis was performed against preoperative iHot12, and iHot12 change at 2years. The mean FV was 18.86± 12.4 SD. Mean MI was 36.07, SD 15.36. Mean preop iHot12 score was 29.83 ± 17.38 SD. Mean change in iHot12 at 2 years was+36.47 ± 28.44 SD. Females and a higher BMI were statistically correlated to a lower preoperative iHot12. A lower preop iHot12 score and a higher preop AI were correlated to a bigger change in iHot12 at 2years with statistical significance. MI and FV were not found to have a statistically significant correlation with Outcome measures,. An increased Mckibbin index and femoral anteversion were not correlated with worse outcomes at two years. PAO alone in the presence of increased femoral anteversion avoids risks associated with FO which can be performed later if required


Bone & Joint Open
Vol. 5, Issue 10 | Pages 858 - 867
11 Oct 2024
Yamate S Hamai S Konishi T Nakao Y Kawahara S Hara D Motomura G Nakashima Y

Aims. The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. Methods. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores. Results. Of the 58 patients (62 hips), two (two hips) presented with dislocation or reoperation, and Kaplan-Meier analysis indicated a five-year survival rate of 96.7% (95% CI 92.4 to 100). Mean stem anteversion was 35.2° (SD 18.2°) for the Taperloc stem and 29.8° (SD 7.9°) for the Wagner Cone stem; mean reduction from Taperloc to Wagner Cone was 5.4° (SD 18.8°). Overall, 55 hips (52 patients) were simulated, and the prevalence of prosthetic impingement was lower for the Wagner Cone (5.5%, 3/55) compared with the Taperloc (20.0%, 11/55) stem, with an odds ratio of 0.20 (p = 0.038). Among the 33 respondents to the postal survey (36 hips), the mean scores were VAS pain 10.9, VAS satisfaction 86.9, and OHS 44.7. A multivariable analysis revealed that reduction of stem anteversion from Taperloc to Wagner Cone was more favourable for VAS pain (p = 0.029) and VAS satisfaction (p = 0.002). Conclusion. The mid-term survival rate for THA using the Wagner Cone stem was high, which may be supported by a reduction in prosthetic impingement. The reduction in excessive stem anteversion by using a tapered cone stem was associated with reduced pain and increased patient satisfaction. Cite this article: Bone Jt Open 2024;5(10):858–867


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims. Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane. Methods. Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation. Results. Overall, 26/40 hips had a centre of rotation displaced posteriorly compared to the contralateral hip, increasing to 33/40 once corrected for sagittal tilt, with a mean posterior displacement of 7 mm. Linear regression analysis indicated that stem anteversion needed to be increased by 10.8° to recreate the head centre in the AP plane. Merely matching the native version would result in a 12 mm posterior displacement. Conclusion. This study demonstrates the significant incidence of posterior displacement of the head centre in uncemented hip arthroplasty. Effects of such displacement include a reduction in impingement free range of motion, potential alterations in muscle force vectors and lever arms, and impaired proprioception due to muscle fibre reorientation. Cite this article: Bone Joint Res 2022;11(3):180–188


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 77 - 77
19 Aug 2024
Fu H Singh G H C Lam J Yan CH Cheung A Chan PK Chiu KY
Full Access

Hip precautions following total hip arthroplasty (THA) limits flexion, adduction and internal rotation, yet these precautions cause unnecessary psychological stress. This study aims to assess bony and implant impingement using virtual models from actual patient's bony morphology and spinopelvic parameters to deduce whether hip precautions are necessary with precise implant positioning in the Asian population. Individualized sitting and standing sacral slope data of robotic THAs performed at two tertiary referral centers in Hong Kong was inputted into the simulation system based on patients’ pre-operative sitting and standing lumbar spine X-rays. Three-dimensional dynamic models were reconstructed using the Stryker Mako THA 4.0 software to assess bony and implant impingement both anteriorly and posteriorly, with default cup placement at 40° inclination and 20° anteversion. Femoral anteversion followed individual patient's native version. A 36mm hip ball was chosen for all cups equal or above 48mm and 32mm for those below. Anterior impingement was assessed by hip flexion and posterior impingement was assessed by hip extension. 113 patients were included. At neutral rotation and adduction, no patients had anterior implant impingement at hip flexion of 100°. 1.7% had impingement at 110°, 3.5% had impingement at 120°, 9.7% had impingement at 130°. With 20° of internal rotation and adduction, 0.8% had anterior implant impingement at hip flexion of 90°, 7.1% had impingement at 100° and 18.5% had impingement at 110°. With the hip externally rotated by 20°, 0.8% of patients had posterior implant impingement, and 8.8% bony impingement at 0° extension. With enabling technology allowing accurate component positioning, hip precautions without limiting forward flexion in neutral position is safe given precise implant positioning and adequate osteophyte removal. Patients should only be cautioned about combined internal rotation, adduction with flexion


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 822 - 831
1 Jul 2020
Kuroda Y Saito M Çınar EN Norrish A Khanduja V

Aims. This paper aims to review the evidence for patient-related factors associated with less favourable outcomes following hip arthroscopy. Methods. Literature reporting on preoperative patient-related risk factors and outcomes following hip arthroscopy were systematically identified from a computer-assisted literature search of Pubmed (Medline), Embase, and Cochrane Library using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and a scoping review. Results. Assessment of these texts yielded 101 final articles involving 90,315 hips for qualitative analysis. The most frequently reported risk factor related to a less favourable outcome after hip arthroscopy was older age and preoperative osteoarthritis of the hip. This was followed by female sex and patients who have low preoperative clinical scores, severe hip dysplasia, altered hip morphology (excess acetabular retroversion or excess femoral anteversion or retroversion), or a large cam deformity. Patients receiving workers’ compensation or with rheumatoid arthritis were also more likely to have a less favourable outcome after hip arthroscopy. There is evidence that obesity, smoking, drinking alcohol, and a history of mental illness may be associated with marginally less favourable outcomes after hip arthroscopy. Athletes (except for ice hockey players) enjoy a more rapid recovery after hip arthroscopy than non-athletes. Finally, patients who have a favourable response to local anaesthetic are more likely to have a favourable outcome after hip arthroscopy. Conclusion. Certain patient-related risk factors are associated with less favourable outcomes following hip arthroscopy. Understanding these risk factors will allow the appropriate surgical indications for hip arthroscopy to be further refined and help patients to comprehend their individual risk profile. Cite this article: Bone Joint J 2020;102-B(7):822–831


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1578 - 1584
1 Dec 2019
Batailler C Weidner J Wyatt M Pfluger D Beck M

Aims. A borderline dysplastic hip can behave as either stable or unstable and this makes surgical decision making challenging. While an unstable hip may be best treated by acetabular reorientation, stable hips can be treated arthroscopically. Several imaging parameters can help to identify the appropriate treatment, including the Femoro-Epiphyseal Acetabular Roof (FEAR) index, measured on plain radiographs. The aim of this study was to assess the reliability and the sensitivity of FEAR index on MRI compared with its radiological measurement. Patients and Methods. The technique of measuring the FEAR index on MRI was defined and its reliability validated. A retrospective study assessed three groups of 20 patients: an unstable group of ‘borderline dysplastic hips’ with lateral centre edge angle (LCEA) less than 25° treated successfully by periacetabular osteotomy; a stable group of ‘borderline dysplastic hips’ with LCEA less than 25° treated successfully by impingement surgery; and an asymptomatic control group with LCEA between 25° and 35°. The following measurements were performed on both standardized radiographs and on MRI: LCEA, acetabular index, femoral anteversion, and FEAR index. Results. The FEAR index showed excellent intraobserver and interobserver reliability on both MRI and radiographs. The FEAR index was more reliable on radiographs than on MRI. The FEAR index on MRI was lower in the stable borderline group (mean -4.2° (. sd. 9.1°)) compared with the unstable borderline group (mean 7.9° (. sd. 6.8°)). With a FEAR index cut-off value of 2°, 90% of patients were correctly identified as stable or unstable using the radiological FEAR index, compared with 82.5% using the FEAR index on MRI. The FEAR index was a better predictor of instability on plain radiographs than on MRI. Conclusion. The FEAR index measured on MRI is less reliable and less sensitive than the FEAR index measured on radiographs. The cut-off value of 2° for radiological FEAR index predicted hip stability with 90% probability. Cite this article: Bone Joint J 2019;101-B:1578–1584


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1140 - 1146
1 Sep 2017
Shoji T Yamasaki T Izumi S Murakami H Mifuji K Sawa M Yasunaga Y Adachi N Ochi M

Aims. Our aim was to evaluate the radiographic characteristics of patients undergoing total hip arthroplasty (THA) for the potential of posterior bony impingement using CT simulations. Patients and Methods. Virtual CT data from 112 patients who underwent THA were analysed. There were 40 men and 72 women. Their mean age was 59.1 years (41 to 76). Associations between radiographic characteristics and posterior bony impingement and the range of external rotation of the hip were evaluated. In addition, we investigated the effects of pelvic tilt and the neck/shaft angle and femoral offset on posterior bony impingement. Results. The range of external rotation and the ischiofemoral length were significantly lower, while femoral anteversion, the ischial ratio, and ischial angle were significantly higher in patients with posterior bony impingement compared with those who had implant impingement (p <  0.05). The range of external rotation positively correlated with ischiofemoral length (r = 0.49, p < 0.05), and negatively correlated with ischial length (r = -0.49, p < 0.05), ischial ratio (r =- 0.49, p < 0.05) and ischial angle (r = -0.55, p < 0.05). The range of external rotation was lower in patients with posterior pelvic tilt (p < 0.05) and in those with a high offset femoral component (p < 0.05) due to posterior bony impingement. Conclusion. Posterior bony impingement after THA is more likely in patients with a wider ischium and a narrow ischiofemoral space. A high femoral offset and posterior pelvic tilt are also risk factors for this type of impingement. Cite this article: Bone Joint J 2017;99-B:1140–6


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 11 - 11
1 Oct 2020
Wells JE Young WH Levy ET Fey NP Huo MH
Full Access

Purpose. Patients with acetabular dysplasia demonstrate altered biomechanics during gate and other activities. We hypothesized that these patients exhibit a compensatory increase in the anterior pelvic tilt during gait. Materials & Methods. Twelve patients were included in this prospective radiographic and gait analysis study prior to the PAO. All were women. The mean age was 27 years (+/− 8 yrs). Tonnis grade was zero in nine, and one in three hips. All patients performed multiple one-minute walking trials on the level, the incline, and the decline treadmill surfaces in an optical motion capture lab. Anterior pelvic tilt is reported in (+), while the posterior pelvic tilt is reported in (–) values. Results. Radiographic Data. : The mean alpha angle measured from the Dunn and the frog lateral images was 63.0º±17.4, and 54.7º±16.4, respectively. The mean LCEA was 14.9°±6.1, and the mean anterior center edge angle was 18.3°±8.9. the mean acetabular version at 1, 2, and 3 o'clock were 12.1°±11.6, 29.2°±9.9, and 23.3°±7.4, respectively. Intra-class correlation coefficient (ICC) for these measurements were 0.934, 0.895, and 0.971, respectively. The mean femoral anteversion, as measured on the 3D CT scan was 21.3°±16.1. The mean hip flexion range was 107.1°± 7.2. The mean pelvic tilt was 88.7 mm ± 14.4 using the PS-SI distance with an ICC of 0.998. Gait Data. : Baseline measurements were done in the standing position. On the leveled surface, 5 patients had anterior (+) while 7 had posterior (−) pelvic tilt. The mean posterior pelvic tilt was 1.0° with the range of −2.8° to +0.67°. On the inclined surface, all patients had posterior (−) pelvic tilt. The mean pelvic tilt was −4.9° with the range of −6.4° to −3.1°. On the declined surface, 8 patients had anterior (+) while 4 patients had posterior (−) pelvic tilt. The mean pelvic tilt was −0.39° with the range of −1.9° to +1.0°. The pelvic tilt was negatively correlated with the PS-SI distance on all three surfaces with the Spearman coefficients of −0.27, −0.04, and −0.18 on the 3 different surfaces, respectively. Conclusion. Our results demonstrated that the patients with hip dysplasia exhibit variable degrees of the pelvic tilt while walking on different surface inclinations. Weak negative correlation with the standing pelvic tilt measurements from the radiographs suggests that those patients with more anterior standing pelvic tilt tend to have greater compensatory posterior tilt during gait


Bone & Joint Open
Vol. 3, Issue 10 | Pages 759 - 766
5 Oct 2022
Schmaranzer F Meier MK Lerch TD Hecker A Steppacher SD Novais EN Kiapour AM

Aims

To evaluate how abnormal proximal femoral anatomy affects different femoral version measurements in young patients with hip pain.

Methods

First, femoral version was measured in 50 hips of symptomatic consecutively selected patients with hip pain (mean age 20 years (SD 6), 60% (n = 25) females) on preoperative CT scans using different measurement methods: Lee et al, Reikerås et al, Tomczak et al, and Murphy et al. Neck-shaft angle (NSA) and α angle were measured on coronal and radial CT images. Second, CT scans from three patients with femoral retroversion, normal femoral version, and anteversion were used to create 3D femur models, which were manipulated to generate models with different NSAs and different cam lesions, resulting in eight models per patient. Femoral version measurements were repeated on manipulated femora.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims

To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia.

Methods

We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure.


Bone & Joint Open
Vol. 4, Issue 1 | Pages 3 - 12
4 Jan 2023
Hardwick-Morris M Twiggs J Miles B Al-Dirini RMA Taylor M Balakumar J Walter WL

Aims

Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation.

Methods

This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC).


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 735 - 742
1 Jul 2023
Andronic O Germann C Jud L Zingg PO

Aims

This study reports mid-term outcomes after periacetabular osteotomy (PAO) exclusively in a borderline hip dysplasia (BHD) population to provide a contrast to published outcomes for arthroscopic surgery of the hip in BHD.

Methods

We identified 42 hips in 40 patients treated between January 2009 and January 2016 with BHD defined as a lateral centre-edge angle (LCEA) of ≥ 18° but < 25°. A minimum five-year follow-up was available. Patient-reported outcomes (PROMs) including Tegner score, subjective hip value (SHV), modified Harris Hip Score (mHHS), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were assessed. The following morphological parameters were evaluated: LCEA, acetabular index (AI), α angle, Tönnis staging, acetabular retroversion, femoral version, femoroepiphyseal acetabular roof index (FEAR), iliocapsularis to rectus femoris ratio (IC/RF), and labral and ligamentum teres (LT) pathology.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 32 - 32
1 Oct 2019
Matta J Delagramaticas D Tatka J
Full Access

Background. Total hip arthroplasty requires proper sizing and placing of implants to ensure excellent outcomes and reduce complications. Calculation of femoral offset is an important consideration for optimal reconstruction of the hip biomechanics. Femoral offset can be measured on plain films or with flouroscopy if the x-ray beam is perpendicular to the plane determined by the angle between the neck axis and femoral shaft axis. This distance is evident only with the femur in the correct degree of rotation. Though pre-operative templating for femoral component size and offset is a regular accepted practice, a consistent method for assessing correct femoral rotation on the AP x-ray view has not been established. Purpose/Hypthesis. The purpose of the current study was to establish and validate a method for identifying radiographic landmarks on the proximal femur that would reliably indicate that the femur was in the proper degree of rotation to represent the true offset from the head center to shaft center. Methods. Lead markers were placed on areas of the greater trochanter followed by xrays. Markers placed on locations on the anterior and posterior greater trochanter duplicated reliable radiographic lines. Proximal femurs were dissected to the bone and rotated about their long axis from neutral rotation, defined at the point when the anterior and posterior aspects of the greater trochanter were aligned radiographically. Radiographs were taken at 2 degree increments in both internal and external rotation until 10 degrees, then again at 30 degrees. A custom script was used to calculate the femoral offset at these rotations at these locations. Descriptive analysis was performed to assess the relationship between rotation angle and femoral offset. Results. The mean femoral offset was observed to be 38.21 mm (SD 4.93, median 37.82, range 30.52–46.27). The mean rotation of max offset was −3.6° (SD 5.6, median −6, range −10 to +8). The average underestimation error (the difference between calculated offset at neutral rotation and observed maximum femoral offset) was 0.92 mm (median 0.74, range 0 to 2.07 mm). Conclusion. Alignment of the radiographic lines created by the anterior and posterior aspects of the greater trochanter is a reliable and accurate rotational positioning method for measuring femoral offset when using plain films or fluoroscopy. It is a feasible method that can be applied preoperatively and/or intraoperatively to optimize accuracy of femoral offset for THA procedures. For any tables or figures, please contact the authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1586 - 1591
1 Dec 2007
Flecher X Parratte S Aubaniac J Argenson J

A clinical and radiological study was conducted on 97 total hip replacements performed for congenital hip dislocation in 79 patients between 1989 and 1998 using a three-dimensional custom-made cementless stem. The mean age at operation was 48 years (17 to 72) and the mean follow-up was for 123 months (83 to 182). According to the Crowe classification, there were 37 class I, 28 class II, 13 class III and 19 class IV hips. The mean leg lengthening was 25 mm (5 to 58), the mean pre-operative femoral anteversion was 38.6° (2° to 86°) and the mean correction in the prosthetic neck was −23.6° (−71° to 13°). The mean Harris hip score improved from 58 (15 to 84) to 93 (40 to 100) points. A revision was required in six hips (6.2%). The overall survival rate was 89.5% (95% confidence interval 89.2 to 89.8) at 13 years when two hips were at risk. This custom-made cementless femoral component, which can be accommodated in the abnormal proximal femur and will correct the anteversion and frontal offset, provided good results without recourse to proximal femoral corrective osteotomy