The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1385 - 1390
1 Oct 2005
Niva MH Kiuru MJ Haataja R Pihlajamäki HK

The purpose of this study was to describe the anatomical distribution and incidence of fatigue injuries of the femur in physically-active young adults, based upon MRI studies. During a period of 70 months, 1857 patients with exercise-induced pain in the femur underwent MRI of the pelvis, hips, femora, and/or knees. Of these, 170 patients had a total of 185 fatigue injuries, giving an incidence of 199 per 100 000 person-years. Bilateral injuries occurred in 9% of patients. The three most common sites affected were the femoral neck (50%), the condylar area (24%) and the proximal shaft (18%). A fatigue reaction was seen in 57%, and a fracture line in 22%. There was a statistical correlation between the severity of the fatigue injury and the duration of pain (p = 0.001). The location of the pain was normally at the site of the fatigue injury. Fatigue injuries of the femur appear to be relatively common in physically-active patients


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 241 - 248
1 Feb 2012
Firoozabadi R McDonald E Nguyen T Buckley JM Kandemir U

Filling the empty holes in peri-articular locking plates may improve the fatigue strength of the fixation. The purpose of this in vitro study was to investigate the effect of plugging the unused holes on the fatigue life of peri-articular distal femoral plates used to fix a comminuted supracondylar fracture model. A locking/compression plate was applied to 33 synthetic femurs and then a 6 cm metaphyseal defect was created (AO Type 33-A3). The specimens were then divided into three groups: unplugged, plugged with locking screw only and fully plugged holes. They were then tested using a stepwise or run-out fatigue protocol, each applying cyclic physiological multiaxial loads. All specimens in the stepwise group failed at the 770 N load level. The mean number of cycles to failure for the stepwise specimen was 25 500 cycles (. sd. 1500), 28 800 cycles (. sd.  6300), and 26 400 cycles (. sd. 2300) cycles for the unplugged, screw only and fully plugged configurations, respectively (p = 0.16). The mean number of cycles to failure for the run-out specimens was 42 800 cycles (. sd. 10 700), 36 000 cycles (. sd. 7200), and 36 600 cycles (. sd.  10 000) for the unplugged, screw only and fully plugged configurations, respectively (p = 0.50). There were also no differences in axial or torsional stiffness between the constructs. The failures were through the screw holes at the level of comminution. In conclusion, filling the empty combination locking/compression holes in peri-articular distal femur locking plates at the level of supracondylar comminution does not increase the fatigue life of the fixation in a comminuted supracondylar femoral fracture model (AO 33-A3) with a 6 cm gap


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (. sd. 33 900) vs 12 800 cycles (. sd. 6100); p = 0.007) and mean axial stiffness (220 N/mm (. sd. 80) vs 70 N/mm (. sd. 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (. sd. 0.9) vs 5.1 Nm/° (. sd. 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (. sd. 25 600) vs 52 400 cycles (. sd. 22 500); p = 0.04). The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients. Cite this article: Bone Joint J 2014;96-B:114–21


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 4 - 4
1 Oct 2021
Pleasant H Robinson P Robinson C Nicholson J
Full Access

Management of highly displaced acromioclavicular joint (ACJ) injuries remain contentious. It is unclear if delayed versus acute reconstruction has an increased risk of fixation failure and complications. The primary aim of this was to compare complications of early versus delayed reconstruction. The secondary aim was to determine modes of failure of ACJ reconstruction requiring revision surgery. A retrospective study was performed of all patients who underwent operative reconstruction of ACJ injuries over a 10-year period (Rockwood III-V). Reconstruction was classed as early (<12 weeks from injury) or delayed (≥12 weeks). Patient demographics, fixation method and post-operative complications were noted, with one-year follow-up a minimum requirement for inclusion. Fixation failure was defined as loss of reduction requiring revision surgery. 104 patients were analysed (n=60 early and n=44 delayed). Mean age was 42.0 (SD 11.2, 17–70 years), 84.6% male and 16/104 were smokers. No difference was observed between fixation failure (p=0.39) or deep infection (p=0.13) with regards to acute versus delayed reconstruction. No patient demographic or timing of surgery was predictive of fixation failure on regression modelling. Overall, eleven patients underwent revision surgery for loss of reduction and implant failure (n=5 suture fatigue, n=2 endo-button escape, n=2 coracoid stress fracture and n=2 deep infection). This study suggests that delayed ACJ reconstruction does not have a higher incidence of fixation failure or major complications compared to acute reconstruction. For those patients with ongoing pain and instability following a trial of non-operative treatment, delayed reconstruction would appear to be a safe treatment approach


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 466 - 466
1 Sep 2012
Ditsios K Kapoukranidou D Boutsiadis A Chatzisotiriou A Albani M Christodoulou A
Full Access

Purpose of this study is to create an experimental model of electrophysologic evaluation of the supraspinatus muscle on rats, after traumatic rupture of its tendon. The population of this study consisted of 10 male Sprague Dawley rats weighting 300–400g. Under general anaesthesia we proceeded with traumatic rupture of the supraspinatus tendon and exposure of the muscle. The scapula was immobilized, and the supraspinatus tendon was attached to a force transducer using a 3–0 silk thread. A dissection was performed in order to identify the suprascapular nerve, which was then stimulated with a silver electrode. Stimulations were produced by a stimulator (Digitimer Stimulator DS9A) and were controlled by a programmer (Digitimer D4030). Fiber length was adjusted until a single stimulus pulse elicited maximum force during a twitch under isometric conditions. Rectangular pulses of 0.5 ms duration were applied to elicit twitch contractions. During the recordings, muscles were rinsed with Krebs solution of approximately 37 8C (pH 7.2–7.4) and aerated with a mixture of 95% O2 and 5% CO2. The output from the transducer was amplified and recorded on a digital interface (CED). The following parameters were measured at room temperature (20–21 8C): single twitch tension; time to peak; half relaxation time; tetanic tensions at 10, 20, 40, 80 and 100 Hz; and fatigue index, which was evaluated using a protocol of low frequency (40 Hz) tetanic contraction, during 250 ms in a cycle of 1 s, for a total time of 180 s. The fatigue index value was then calculated by the formula [fatigue index=(initial tetanic tension − end tetanic tension) ∗ 100/(initial tetanic tension)]. In the end, the transducer was calibrated with standard weights and tensions were converted to grams. The mean single twitch was 8.2, the time to peak 0.034 msec and the half relaxation time 0.028 msec. The strength of titanic muscle contractures was 5.7 msec at 10Hz and 17.7 at 100Hz. Finally, the fatigue index was calculated at 48.4. We believe that electrophysiologic evaluation of the supraspinatus muscle in rats will help us understanding the pathology of muscle atrophy after rotator cuff tears and possibly the functional restoration after cuff repair


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1070 - 1077
1 Oct 2023
Png ME Costa M Nickil A Achten J Peckham N Reed MR

Aims

To compare the cost-effectiveness of high-dose, dual-antibiotic cement versus single-antibiotic cement for the treatment of displaced intracapsular hip fractures in older adults.

Methods

Using data from a multicentre randomized controlled trial (World Hip Trauma Evaluation 8 (WHiTE-8)) in the UK, a within-trial economic evaluation was conducted. Resource usage was measured over 120 days post randomization, and cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY), gained from the UK NHS and personal social services (PSS) perspective in the base-case analysis. Methodological uncertainty was addressed using sensitivity analysis, while decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 6 - 6
1 Sep 2012
Upadhyay P Beazley J Dunbar M Costa M
Full Access

Introduction. Locking compression plate (LCP) fixation is an established method of treatment of distal third tibial fractures. No biomechanical data exists in the literature regarding their use. Additionally no data exists on the biomechanical advantage of locking screw fixation over non-locking screw fixation for these fractures. In this study the axial and torsional stiffness, axial load to failure and fatigue performance of a 3.5 mm LCP medial distal tibia Synthes plate was evaluated for the stabilisation of distal third tibial fractures. Additionally the performance of the plate in uni and bicortical locked mode as well as non-locked mode was evaluated. Methods. A standardized oblique fracture pattern was created in the tibial metaphysis of 3rd generation composite tibias, 40 mm from the distal end of the tibia (AO 43-A2.3). A 10mm fracture gap was used to model a comminuted metaphyseal fracture. A 3.5 mm medial distal tibia LCP was applied with bi or unicortical locking or bicortical non-locking screws to 5 tibias respectively. All the bio-mechanical tests were performed on a Bose 3510 Electroforce material testing machine. A ramp to load, loading profile was used to determine the static axial and torsional performance of the construct. Fatigue testing simulated a 6 week gradual weight bearing régime with the load increasing every two weeks by 400N until either 250,000 cycles were completed or the construct failed. Results. The non-locked plate demonstrated a significantly higher load to failure than both the bicortical and unicortical locked plates, 683N vs. 575N vs. 483N respectively(p<0.01). The non locked plate also demonstrated significantly higher mean axial stiffness than the bicortical locked plate and unicortical locked plate 632±13 N/mm, 337±12N/mm and 266±6 N/mm respectively (p <0.01). The non locked plate demonstrated the highest torsional stiffness followed by the bi and unicortical locking plates 1.16 ±.08 Nmm vs. 0.79 ± .06 Nmm vs.0.40 ± 0.02 Nmm respectively (p < 0.01). The non locked plate demonstrated higher endurance than the bi and unicortical locking plates over a 6 week simulated fatigue cycle with 1.75mm, 2.10mm and 2.3mm residual displacement at 1600N respectively (p < 0.01). Discussion. This is the first study that has examined the biomechanical properties of the LCP when used for distal third tibial fractures. A review of the literature suggests LCPs outperform dynamic compression plates in osteoporotic bone but demonstrates no clear biomechanical advantage in using a locking construct in non-osteoporotic bone. In our study the non locked construct outperformed the locked constructs in all parameters assessed. We conclude there is no advantage in using a locking construct for distal third tibial fractures in good quality bone


Bone & Joint Open
Vol. 3, Issue 10 | Pages 746 - 752
1 Oct 2022
Hadfield JN Omogbehin TS Brookes C Walker R Trompeter A Bretherton CP Gray A Eardley WGP

Aims

Understanding of open fracture management is skewed due to reliance on small-number lower limb, specialist unit reports and large, unfocused registry data collections. To address this, we carried out the Open Fracture Patient Evaluation Nationwide (OPEN) study, and report the demographic details and the initial steps of care for patients admitted with open fractures in the UK.

Methods

Any patient admitted to hospital with an open fracture between 1 June 2021 and 30 September 2021 was included, excluding phalanges and isolated hand injuries. Institutional information governance approval was obtained at the lead site and all data entered using Research Electronic Data Capture. Demographic details, injury, fracture classification, and patient dispersal were detailed.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 584 - 593
15 Aug 2023
Sainio H Rämö L Reito A Silvasti-Lundell M Lindahl J

Aims

Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures.

Methods

We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture comminution, medial side comminution) in the first analysis and with treatment-related variables (different surgeon-controlled factors, e.g. plate length, screw placement, and proximal fixation) in the second analysis to predict the nonunion leading to secondary surgery in distal femur fractures.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 14 - 14
1 Apr 2013
Penzkofer U Schmidt R Bachmaier S Augat P
Full Access

Background. The inherently high stiffness of locked plate constructs is increasingly recognized as a potential cause of deficient healing observed in patients with periarticular locked plating systems. The objective of this study is to perform a biomechanical comparison of distal femur locked plating systems. Methods. Biomechanical study using bone substitutes in a distal femur fracture model (OTA/AO 33-A3). Four different locked plate fixation systems were compared (AxSOS, LCP, PERI-LOC, POLYAX). Eight bone implant constructs of each plating system were evaluated in a multiple testing model to examine static failure, stiffness under static and cyclic loading and cyclic fatigue. Results. The implant systems made of titanium alloy (POLYAX & LCP) supported smaller torsional stiffness values under static loads and smaller axial stiffness values under cyclic loads compared with the implant systems made of stainless steel (PERI-LOC & AxSOS). All bone implant constructs reached the cyclic failure criterion of 10 degrees displacement at the fracture area within the third load level (>50000 cycles) except for the LCP which failed earlier. Conclusion. The tested four different locked plating systems differ significantly in terms of stiffness and load to failure. Two of the clinical available systems differed almost 100% in stiffness values. And one system differed almost 100% in fatigue strength. For clinical use, this knowledge is essential for the practicing orthopaedic surgeon


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_12 | Pages 4 - 4
1 Jun 2016
Grant J Reekie T Rust P
Full Access

Introduction. Closed avulsion of the Flexor Digitorum Profundus (FDP) from distal phalanx most commonly affects the ring finger when an extensive force is applied to a finger in active flexion. Whilst it is undoubtably reasonable to provide treatment for those who present with symptoms, there may be a cohort of people who sustain an avulsion without noticing. This study aims to quantify the effect of ring finger FDP avulsion on overall grip strength to determine the functional effect of a missed injury. Method. Right handed volunteers, with no abnormality on examination were included (N= 42). Proximal muscle group action was excluded. Grip strength was tested using a Jamar dynamometer with and without splinting of the ring finger to block flexion at the DIPJ and repeated six times alternately to mitigate the effects of fatigue. Results. Most subjects showed a small (0.3–3kg) change in their average grip strength with the splint (N= 29). Some showed a dramatic change in their grip strength (6–11.4) (N=6) others showed no change or slight improvement with the splint (−3–0) (N=7). Data were not normally distributed (kolmogorov-smirnov p=0.023). A wilcoxon signed rank test showed a statistically significant difference in performance with, compared to without, the splint, mean 2.34kg reduction (−3.3 − 11.4) (p <0.0005. Discussion. Horton et al have examined the quadriga effect and shown that the individual strength of other digits is reduced when one FDP is isolated. This implies overall grip strength should be reduced; our data supports this assertion. However despite splinting, the majority of subjects were still within the normal range of power for age. Larger scale studies are required to assess the functional effect of repair vs conservative management


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 13 - 13
1 Apr 2013
Hoffmann S Paetzold R Mair S Stephan D Buehren V Augat P
Full Access

Hypothesis. The proximal geometry and design of trochanteric nails affects initial construct stiffness, fatigue survival, and preservation of biomechanical stability over time. Materials & Methods. Eight pairs of human cadaveric femora were implanted with two different short intramedullary nails with (Intertan, (S&N)) and without (Gamma 3, (Stryker)) interlocking lag screws. Femoral osteotomies were performed to generate a pertrochanteric multifragmentary unstable fracture (OTA 31-A 2.2). The bones were tested in a cyclic testing protocol with increasing loads of 100 N every 20.000 cycles (start point 50/500 N) simulating one leg stance. The position of the femur was 10° adduction and 10° extension. Stiffness, failure load, and cycles to failure were measured. Results. Initially, stiffness of the interlocking lag screw nail was 40 % higher (p < 0,05) than for the non-interlocking nail. During the test, the difference in stiffness gradually decreased. Load to failure (9 %, p < 0,05) and cycles to failure (13 %, p < 0,05) were also higher for the interlocking nail construct. Discussion & Conclusion. The interlocking screw design of intramedullary nail constructs improves the mechanical performance in unstable trochanteric fractures. This may result in improved clinical performance


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims

The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols.

Methods

A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 316 - 316
1 Sep 2012
Pandorf T Preuss R Flohr M Upmann C
Full Access

Introduction. In knee arthroplasty a ceramic component has several advantages: first, there is no ion release implying a risk for potential allergies. Second, the hardness of the material leads to a scratch resistance which ultimately reduces PE wear over time. In the past, ceramic components in knee applications were limited in the variety of design possibilities due to necessary thickness of the component resulting from the associated fracture risk of ceramics. By the development of an alumina matrix composite material with increased mechanical properties it is possible to develop ceramic knee components which have nearly the same design as a metal component and use the same implantation technique as well as the same instruments. This offers the surgeon the opportunity to choose intraoperatively between metal or ceramic knee components. Extensive in-vitro testing shows that ceramic knee components achieve superior mechanical test results. The reliability of the components is proven by two different burst tests and a fatigue test for both a femoral and a tibial ceramic knee component. Material and method. The mechanical proof-test was developed by subsequent steps of numerical load/stress analysis and design of an adequate mechanical test equipment. The procedure was organized as follows:. Oncologic: Analysis of relevant maximum in-vivo loading conditions. Analysis of the “boundary conditions”. Finite Element analysis: Identifying regions of highest stress concentration. Design analysis and accommodation if necessary. Development of an adequate mechanical test equipment which produces stresses comparable to the in-vivo conditions. Performing mechanical tests with ceramic femoral components. Validation of the test concept: comparison of test results and stress analysis. Assign “safety margin”,. Establish “proof test”. Results. Two independent load scenarios have been determined for each type of components as being in-vivo relevant. Hence, the developed proof-test consists of two subsequent load tests, the so-called regular test and the tension test for the femoral components, and the upper side test and the lower side test for the tibial components. In the regular test, the mechanical strength of the polished outer condyles is tested using a force which is equivalent to an in-vivo loading of 16 times bodyweight. In the tension test, the interior sides of the condyles are stressed in the sagittal plane ensuring a mechanically reliable implantation. This test is performed with a force equivalent to 10 times bodyweight. Discussion. The procedure to determine the proof loads using the maximum in-vivo loads together with a safety factor ensures the mechanical safety of the ceramic knee component. Together with the well-known excellent wear and biological behaviour of ceramics, this application provides an alternative to common metallic knee components. Clinical observations in the framework of a multi-centre study in different European countries have been started and show very promising results


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 17 - 25
1 Jan 2020
Trickett RW Mudge E Price P Pallister I

Aims

The aim of this study was to develop a psychometrically sound measure of recovery for use in patients who have suffered an open tibial fracture.

Methods

An initial pool of 109 items was generated from previous qualitative data relating to recovery following an open tibial fracture. These items were field tested in a cohort of patients recovering from an open tibial fracture. They were asked to comment on the content of the items and structure of the scale. Reduction in the number of items led to a refined scale tested in a larger cohort of patients. Principal components analysis permitted further reduction and the development of a definitive scale. Internal consistency, test-retest reliability, and responsiveness were assessed for the retained items.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1385 - 1391
1 Oct 2019
Nicholson JA Gribbin H Clement ND Robinson CM

Aims

The primary aim of this study was to determine if delayed clavicular fixation results in a greater risk of operative complications and revision surgery.

Patients and Methods

A retrospective case series was undertaken of all displaced clavicular fractures that underwent plate fixation over a ten-year period (2007 to 2017). Patient demographics, time to surgery, complications, and mode of failure were collected. Logistic regression was used to identify independent risk factors contributing towards operative complications. Receiver operating characteristic (ROC) curve analysis was used to determine if a potential ‘safe window’ exists from injury to delayed surgery. Propensity score matching was used to construct a case control study for comparison of risk.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 995 - 1001
1 Aug 2019
Nicholson JA Clement N Goudie E Robinson CM

Aims

The primary aim of this study was to establish the cost-effectiveness of the early fixation of displaced midshaft clavicle fractures.

Patients and Methods

A cost analysis was conducted within a randomized controlled trial comparing conservative management (n = 92) versus early plate fixation (n = 86) of displaced midshaft clavicular fractures. The incremental cost-effectiveness ratio (ICER) was used to express the cost per quality-adjusted life-year (QALY). The Six-Dimension Short-Form Health Survey (SF-6D) score was used as the preference-based health index to calculate the cost per QALY at 12 months after the injury.


Bone & Joint Research
Vol. 6, Issue 4 | Pages 216 - 223
1 Apr 2017
Ang BFH Chen JY Yew AKS Chua SK Chou SM Chia SL Koh JSB Howe TS

Objectives

External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised locking compression plate is a low profile alternative. However, the biomechanical differences have not been assessed. The objective of this study was to evaluate the axial and torsional stiffness of the externalised titanium locking compression plate (ET-LCP), the externalised stainless steel locking compression plate (ESS-LCP) and the unilateral external fixator (UEF).

Methods

A fracture gap model was created to simulate comminuted mid-shaft tibia fractures using synthetic composite bones. Fifteen constructs were stabilised with ET-LCP, ESS-LCP or UEF (five constructs each). The constructs were loaded under both axial and torsional directions to determine construct stiffness.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1520 - 1525
1 Nov 2017
Haines N Kempton LB Seymour RB Bosse MJ Churchill C Hand K Hsu JR Keil D Kellam J Rozario N Sims S Karunakar MA

Aims

To evaluate the effect of a single early high-dose vitamin D supplement on fracture union in patients with hypovitaminosis D and a long bone fracture.

Patients and Methods

Between July 2011 and August 2013, 113 adults with a long bone fracture were enrolled in a prospective randomised double-blind placebo-controlled trial. Their serum vitamin D levels were measured and a total of 100 patients were found to be vitamin D deficient (< 20 ng/ml) or insufficient (< 30 ng/mL). These were then randomised to receive a single dose of vitamin D3 orally (100 000 IU) within two weeks of injury (treatment group, n = 50) or a placebo (control group, n = 50). We recorded patient demographics, fracture location and treatment, vitamin D level, time to fracture union and complications, including vitamin D toxicity.

Outcomes included union, nonunion or complication requiring an early, unplanned secondary procedure. Patients without an outcome at 15 months and no scheduled follow-up were considered lost to follow-up. The t-test and cross tabulations verified the adequacy of randomisation. An intention-to-treat analysis was carried out.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 951 - 957
1 Jul 2017
Poole WEC Wilson DGG Guthrie HC Bellringer SF Freeman R Guryel E Nicol SG

Aims

Fractures of the distal femur can be challenging to manage and are on the increase in the elderly osteoporotic population. Management with casting or bracing can unacceptably limit a patient’s ability to bear weight, but historically, operative fixation has been associated with a high rate of re-operation. In this study, we describe the outcomes of fixation using modern implants within a strategy of early return to function.

Patients and Methods

All patients treated at our centre with lateral distal femoral locking plates (LDFLP) between 2009 and 2014 were identified. Fracture classification and operative information including weight-bearing status, rates of union, re-operation, failure of implants and mortality rate, were recorded.