Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 64 - 64
23 Feb 2023
Faruque R
Full Access

Tendon injuries after distal radius fractures Introduction: Tendon injuries after distal radius fractures are a well-documented complication that can occur in fractures managed both operatively and non-operatively. The extensor tendons, in particular the extensor pollicis longus (EPL) tendon, can be damaged and present late after initial management in a cast, or by long prominent screws that penetrate the dorsal cortex and cause attrition. Similarly, a prominent or distally placed volar plate can damage the flexor pollicis longus tendon (FPL). The aim of our study was to evaluate the incidence of tendon injuries associated with distal radius fractures. We conducted a single centre prospective observational study. Patients aged 18–99 who presented with a distal radius fracture between May 2018 to April 2020 were enrolled and followed-up for 24 months. Tendon injuries in the group were prospectively evaluated. Results: 199 patients with distal radius fractures were enrolled. 119 fractures (59.8%) had fixation and 80 (40.2%) were managed incast. In the non-operative group, 2 (2.5%) had EPL ruptures at approximately 4 weeks post injury. There were no extensor tendon ruptures in the operative group. In the operative group, there were 6 (5%) patients that required removal of metalware for FPL irritation. At the time of operation, there were no tendon ruptures noted. Within the operative group we evaluated plate prominence using a previously described classification (Soong et al.). 5 of the 6 patients (83%) with FPL irritation had Grade 3 prominence. The incidence of both flexor and extensor tendon injury in our cohort was 4%, extensor tendon rupture was 1% and flexor tendon rupture was avoided by early metalware removal. This study demonstrates tendon injuries are not uncommon after distal radius fractures, and close examination and follow-up are necessary to prevent eventual rupture. Plate prominence at the time of fixation should be minimised to reduce the risk of rupture


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 3 - 3
7 Nov 2023
Leslie K Matshidza S
Full Access

Intimate partner violence (IPV) causes significant morbidity and its unlikely to be reported compared to other forms of gender-based violence (GBV). For early detection, understanding Orthopaedic injuries from GBV is vital. This study assesses the pattern of musculoskeletal injuries from GBV and determines the factors associated with it. It is a retrospective observational study of patients aged ≥18 years, with GBV-related acute Orthopaedic injuries. Data was reviewed from January 2021 to December 2021, including, demographic information, soft tissue and bony injuries, relationship to assailant, substance abuse and the day and time of injury. Frequencies and percentages for categorical data were analysed. Chi-square test was used to calculate association. T-test was used to compare groups for continuous & categorical variables. Multivariate analysis was conducted to find the odds ratio and a p-value <0.05 was statistically significant. 138 patients were included, the mean age at presentation being 35.02 years (SD=11). 92.75% of GBV victims were females. Most were unemployed (66.7%). 30.43% (n-42) had a soft tissue injury; superficial laceration being the most common (23.1%), flexor tendon injury (10.87%), hand abscess (5.8%), and extensor tendon injury (5.07%). 71.02 % (n=98) sustained appendicular fractures. 51.45% (n=71) sustained upper limb fractures; distal radius fractures (10.86%) and distal 3rd ulnar fractures (9,42%). 19.57% (n=27) had lower limb fractures; 7.25% (n=10) had lateral malleolus ankle fractures. 63.7% (n=80) of cases were by an intimate partner on weekends (50.73%). 62.31% occurred between 16h00 and 0h00. 41.1% (n=65) reported alcohol abuse. 63.04% had surgery. GBV likely occurs in early middle-aged females by intimate partners influenced by alcohol over the weekends between 16h00 to 0h00. Distal radius/distal 3rd ulnar fractures are the most common bony injuries. Superficial wrist laceration is the commonest soft tissue injury. These findings may assist with early detection and intervention to prevent adverse outcomes in GBV


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 5 - 5
1 Dec 2022
Li T Beaudry E Westover L Chan R
Full Access

The Adams-Berger reconstruction is an effective technique for treating distal radioulnar joint (DRUJ) instability. Graft preparation techniques vary amongst surgeons with insufficient evidence to support one technique over another. Our study evaluated the biomechanical properties of four graft preparation techniques. Extensor tendons were harvested from fresh frozen porcine trotters obtained from a local butcher shop and prepared in one of three configurations (n=5 per group): tendon only; tendon prepared with non-locking, running suture (2-0 FiberLoop, Arthrex, Naples, FL) spaced at 6 mm intervals; and tendon prepared with suture spaced at 12 mm intervals. A fourth configuration of suture alone was also tested. Tendons were allocated in a manner to ensure comparable average diameters amongst groups. Biomechanical testing occurred using custom jigs simulating radial and ulnar tunnels attached to a Bose Electroforce 3510 mechanical testing machine (TA Instruments). After being woven through the jigs, all tendons were sutured end-to-end with 2-0 PROLENE suture (Ethicon). Tendons then underwent a staircase cyclic loading protocol (5-25 Newtons [N] at 1 hertz [Hz] for 1000 cycles, then 5-50 N at 1 Hz for 1000 cycles, then 5-75 N at 1 Hz for 1000 cycles) until graft failure; if samples did not fail during the protocol, they were then loaded to failure. Samples were visually inspected for mode of failure after the protocol. A one-way analysis of variance was used to compare average tendon diameter; post-hac Tuhey tests were used to compare elongation and elongation rate. Survival to cyclic loading was analyzed using Kaplan-Meier survival curves with log rank. Statistical significance was set at a = 0.05. The average tendon diameter of each group was not statistically different [4.17 mm (tendon only), 4.33 mm (FiberLoop spaced 6 mm), and 4.30 mm (FiberLoop spaced 12 mm)]. The average survival of tendon augmented with FiberLoop was significantly higher than tendon only, and all groups had significantly improved survival compared to suture only. There was no difference in survival between FiberLoop spaced 6 mm and 12 mm. Elongation was significantly lower with suture compared to tendon augmented with FiberLoop spaced 6 mm. Elongation rate was significantly lower with suture compared to all groups. Modes of failure included rupture of the tendon, suture, or both at the simulated bone and suture and/or tendon interface, and elongation of the entire construct without rupture. In this biomechanical study, augmentation of porcine tendons with FiberLoop suture spaced at either 6 or 12 mm for DRUJ reconstruction significantly increased survival to a staircase cyclic loading protocol, as suture material was significantly stiffer than any of the tendon graft configurations


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 76 - 76
1 May 2012
S. M P. V
Full Access

Introduction. Getting the distal locking screw lengths right in volar locking plate fixation of distal radius is crucial. Long screws can lead to extensor tendon ruptures whereas short screws can lead to failure of fixation, especially if there is dorsal comminution of the fracture. The aim of our study was to determine the distal radius anatomy in relation to sagittal lengths and distance between dorsal bone edge and extensor tendons based on MRI scan. Method. One hundred consecutive MRI scans of wrist were reviewed by two of the authors on two occasions. All MRI scans were performed for different wrist pathologies except distal radius fractures or tumours. An axial image, two cuts proximal to the last visible articular surface, was selected. Sagittal length at 5 different widths, maximum volar width, radial overhang over distal radio-ulnar joint and the distance between dorsal bone edge and extensor tendons were measured. Results. A total of 120 MRI scans were included of which 74 were women and 46 were men. Mean volar width was 32mm and longest sagittal length was 22 mm (at Lister's tubercle). Length radial to Lister's tubercle was the shortest (17mm) and ulnar sides were 21mm and 29mm. Male measurements were mean 3mm longer than females. Mean radial overhang over DRUJ was 4mm. Distance from bone to tendons was within 2mm of dorsal radius edge. Conclusion. The study provides a reference guide to average screw lengths at different widths of distal radius in males and females. EPL tendon is closest to bone although all the extensor tendons are within 2mm of bone edge and carry a risk of injury from drill and screw placement. DRUJ is also at risk of injury if screws are placed within 4mm of ulnar edge of distal radius


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 48 - 48
1 Dec 2016
Padmore C Stoesser H Nishiwaki M Gammon B Langohr D Lalone E Johnson J King G
Full Access

Distal radius fractures are the most common fracture of the upper extremity. Malunion of the distal radius is a common clinical problem after these injuries and frequently leads to pain, stiffness loss of strength and functional impairments. Currently, there is no consensus as to whether not the mal-aligned distal radius has an effect on carpal kinematics of the wrist. The purpose of this study was to examine the effect of dorsal angulation (DA) of the distal radius on midcarpal and radiocarpal joint kinematics, and their contributions to total wrist motion. A passive wrist motion simulator was used to test six fresh-frozen cadaveric upper extremities (age: 67 ± 17yrs). The specimens were amputated at mid humerus, leaving all wrist flexor and extensor tendons and ligamentous structures intact. Tone loads were applied to the wrist flexor and extensor tendons by pneumatic actuators via stainless steel cables. A previously developed distal radius implant was used to simulate native alignment and three DA deformity scenarios (DA 10 deg, 20 deg, and 30 deg). Specimens were rigidly mounted into the simulator with the elbow at 90 degrees of flexion, and guided through a full range of flexion and extension passive motion trials (∼5deg/sec). Carpal motion was captured using optical tracking; radiolunate and capitolunate joint motion was measured and evaluated. For the normally aligned radius, radiolunate joint motion predominated in flexion, contributing on average 65.4% (±3.4). While the capitolunate joint motion predominated in extension, contributing on 63.8% (±14.0). Increasing DA resulted in significant alterations in radiolunate and capitolunate joint kinematics (p<0.001). There was a reduction of contribution from the capitolunate joint to total wrist motion throughout flexion-extension, significant from 5 degrees of wrist extension to full extension (p = 0.024). Conversely, the radiolunate joint increased its contribution to motion with increasing DA; significant from 5 degrees of wrist extension to full extension as the radiolunate and capitolunate joint kinematics mirrored each other. A DA of 30 degrees resulted in an average radiolunate contribution of 72.6% ± 7.7, across the range of motion of 40 degrees of flexion to 25 degrees of extension. The results of our study for the radius in a normal anatomic alignment are consistent with prior investigators, showing the radiocarpal joint dominated flexion, and the midcarpal joint dominated extension; with an average 60/40 division in contributions for the radiocarpal in flexion and the midcarpal in extension, respectfully. As DA increased, the radiocarpal joint provided a larger contribution of motion throughout flexion and extension. This alteration in carpal kinematics with increased distal radius dorsal angulation may increase localised stresses and perhaps lead to accelerated joint wear and wrist pain in patients with malunited distal radial fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 16 - 16
1 Jul 2012
Granville-Chapman J Hacker A Keightley A Sarkhel T Monk J Gupta R
Full Access

Extensor tendon ruptures have been reported in up to 8.8% of patients after volar plating and long screws have been implicated. The dihedral dorsal surface of the distal radius hinders accurate screw length determination using standard radiographic views (lateral; pronation and supination). A ‘dorsal tangential’ view has recently been described, but has not been validated. To validate this view, we mounted a plate-instrumented sawbone onto a jig. Radiographs at different angles were reviewed independently by 11 individuals. Skyline views clearly demonstrated all screw tips, whereas only 69% of screw tips were identifiable on standard views. With screws 2mm proud of the dorsal surface, skyline views detected 67% of long screws (sensitivity). The best of the standard views achieved only 11% sensitivity. At 4mm long, skyline sensitivity was 85%, compared with 25% for standard views. At 6mm long, 100% of long screws were detected on skylines, but only 50% of 8mm long screws were detected by standard views. Inter and intra-observer variability was 0.97 (p=0.005). For dorsal screw length determination of the distal radius, the skyline view is superior to standard views. It is simple to perform and its introduction should reduce the incidence of volar plate-related extensor tendon rupture


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 81 - 81
1 Jan 2013
Evans J Giddins G Miles T
Full Access

Aim. The purpose of this study was to develop and test the utility of a hybrid barbed-suture in the core repair of digital flexor tendon injuries. Despite offering advantages over traditional suture methods, concerns over the cost, strength to failure and biocompatibility of barbed sutures have hindered their development. Moreover the recent designs have been very complex. We have attempted to develop and test a simple barbed suture, to assess it's viability in flexor tendon repair and in particular to establish a baseline for the efficacy and modes of failure barbed sutures, in order to help provide a basis for future research. Method. The barbed suture device was constructed by inserting 3 steel barbs into the weaved construct of a braided polyester suture. The barbed sutures were inserted into 28 porcine lateral extensor tendons yielding a single sided core repair. Tensile testing of the repair was undertaken using a tabletop load frame with the distal end of the tendon fixed in a cryo clamp. Linear load testing to failure was undertaken. Maximum load, repair excursion and repair stiffness were recorded. Results. The barbed suture technique demonstrated a maximum load to failure of 40.4±16.4N. The excursion of the repair at failure point was 31.4±11.6mm. The stiffness of the repair derived from the linear elastic portion of the load displacement curve was 1.0±0.6N/mm. Conclusions. Use of this barbed suture construct offers a fast, easily applied method of flexor tendon repair. The maximum load to failure is comparable to the commonly used non-barbed suture methods. The suture excursion and stiffness findings suggest gap formation at low loads. Failure of the barbed suture seemed to be resisted by the collagen links between longitudinal tendon fibres. Further developments of this very modifiable construct may lead to a viable alternative to the current repair techniques


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 82 - 82
1 Jan 2013
Mahajan R Sung-Jae K Rajgopalan S Mestha P
Full Access

The recognition of the role of TFCC as a major distal radioulnar joint stabilizer and a buffer to compressive forces indicates the importance of preserving as much of this structure as possible. We developed arthroscopic technique for repair of Palmer I B tears of TFCC using a hypodermic needle which obviates the need of any additional skin incision. With wrist under traction important landmarks like radial styloid process, ulnar styloid process, Lister's tubercle and extensor tendons are marked using skin marker. For placement of the arthroscope, 3–4 portal is used and for instruments 6 R and 6 U portals are used. An outside-in technique is used. A 19 G needle is inserted upward from 5mm proximal to the level of the 6 R portal through skin, subcutaneous tissue, capsular tissue and then through the 2mm inner side of detached area of TFCC, while stabilizing it with probe. A 2–0 polydioxanone-PDS suture is passed through needle and caught by grasper placed in the 6 R portal. Now needle is withdrawn and then suture is retrieved out of the joint through the 6 R portal. The procedure is repeated for required number of sutures for dorsal part of peripheral tear. Thus we have stitches with one limb exiting the joint through portal and the other limb entering the joint percutaneously. A small mosquito forceps is passed through the 6 R portal undermining subcutaneous area and these percutaneously passing limbs of sutures are withdrawn through the portal. Now we have sutures entering and exiting through the 6 R portal. Similar procedure is done for ulnar part of peripheral tear through the 6 U portal. Knots are tied and slid beneath the subcutaneous tissue. It offers advantages of a lower risk of neurovascular damage, reduced postoperative pain, faster rehabilitation and better cosmesis


Bone & Joint Open
Vol. 1, Issue 6 | Pages 229 - 235
9 Jun 2020
Lazizi M Marusza CJ Sexton SA Middleton RG

Aims

Elective surgery has been severely curtailed as a result of the COVID-19 pandemic. There is little evidence to guide surgeons in assessing what processes should be put in place to restart elective surgery safely in a time of endemic COVID-19 in the community.

Methods

We used data from a stand-alone hospital admitting and operating on 91 trauma patients. All patients were screened on admission and 100% of patients have been followed-up after discharge to assess outcome.