Advertisement for orthosearch.org.uk
Results 1 - 20 of 240
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 108 - 112
1 Jan 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Buckley L

Endoprosthetic replacement of the proximal femur may be required to treat primary bone tumours or destructive metastases either with impending or established pathological fracture. Modular prostheses are available off the shelf and can be adapted to most reconstructive situations for this purpose. We have assessed the clinical and functional outcome of using the METS (Stanmore Implants Worldwide) modular tumour prosthesis to reconstruct the proximal femur in 100 consecutive patients between 2001 and 2006. We compared the results with the published series for patients managed with modular and custom-made endoprosthetic replacements for the same conditions. There were 52 males and 48 females with a mean age of 56.3 years (16 to 84) and a mean follow-up of 24.6 months (0 to 60). In 65 patients the procedure was undertaken for metastases, in 25 for a primary bone tumour, and in ten for other malignant conditions. A total of 46 patients presented with a pathological fracture, and 19 presented with failed fixation of a previous pathological fracture. The overall patient survival was 63.6% at one year and 23.1% at five years, and was significantly better for patients with a primary bone tumour than for those with metastatic tumour (82.3% vs 53.3%, respectively at one year (p = 0.003)). There were six early dislocations of which five could be treated by closed reduction. No patient needed revision surgery for dislocation. Revision surgery was required by six (6%) patients, five for pain caused by acetabular wear and one for tumour progression. Amputation was needed in four patients for local recurrence or infection. The estimated five-year implant survival with revision as the endpoint was 90.7%. The mean Toronto Extremity Salvage score was 61% (51% to 95%). The implant survival and complications resulting from the use of the modular system were comparable to the published series of both custom-made and other modular proximal femoral implants. We conclude that at intermediate follow-up the modular tumour prosthesis for proximal femur replacement provides versatility, a low incidence of implant-related complications and acceptable function for patients with metastatic tumours, pathological fractures and failed fixation of the proximal femur. It also functions as well as a custom-made endoprosthetic replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1513 - 1520
1 Nov 2009
Sewell MD Spiegelberg BGI Hanna SA Aston WJS Bartlett W Blunn GW David LA Cannon SR Briggs TWR

We undertook a retrospective review of 33 patients who underwent total femoral endoprosthetic replacement as limb salvage following excision of a malignant bone tumour. In 22 patients this was performed as a primary procedure following total femoral resection for malignant disease. Revision to a total femoral replacement was required in 11 patients following failed segmental endoprosthetic or allograft reconstruction. There were 33 patients with primary malignant tumours, and three had metastatic lesions. The mean age of the patients was 31 years (5 to 68). The mean follow-up was 4.2 years (9 months to 16.4 years). At five years the survival of the implants was 100%, with removal as the endpoint and 56% where the endpoint was another surgical intervention. At five years the patient survival was 32%. Complications included dislocation of the hip in six patients (18%), local recurrence in three (9%), peri-prosthetic fracture in two and infection in one. One patient subsequently developed pulmonary metastases. There were no cases of aseptic loosening or amputation. Four patients required a change of bushings. The mean Musculoskeletal Tumour Society functional outcome score was 67%, the mean Harris Hip Score was 70, and the mean Oxford Knee Score was 34. Total femoral endoprosthetic replacement can provide good functional outcome without compromising patient survival, and in selected cases provides an effective alternative to amputation


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1633 - 1640
1 Oct 2021
Lex JR Evans S Parry MC Jeys L Stevenson JD

Aims. Proximal femoral endoprosthetic replacements (PFEPRs) are the most common reconstruction option for osseous defects following primary and metastatic tumour resection. This study aimed to compare the rate of implant failure between PFEPRs with monopolar and bipolar hemiarthroplasties and acetabular arthroplasties, and determine the optimum articulation for revision PFEPRs. Methods. This is a retrospective review of 233 patients who underwent PFEPR. The mean age was 54.7 years (SD 18.2), and 99 (42.5%) were male. There were 90 patients with primary bone tumours (38.6%), 122 with metastatic bone disease (52.4%), and 21 with haematological malignancy (9.0%). A total of 128 patients had monopolar (54.9%), 74 had bipolar hemiarthroplasty heads (31.8%), and 31 underwent acetabular arthroplasty (13.3%). Results. At a mean 74.4 months follow-up, the overall revision rate was 15.0%. Primary malignancy (p < 0.001) and age < 50 years (p < 0.001) were risk factors for revision. The risks of death and implant failure were similar in patients with primary disease (p = 0.872), but the risk of death was significantly greater for patients who had metastatic bone disease (p < 0.001). Acetabular-related implant failures comprised 74.3% of revisions; however, no difference between hemiarthroplasty or arthroplasty groups (p = 0.209), or between monopolar or bipolar hemiarthroplasties (p = 0.307), was observed. There was greater radiological wear in patients with longer follow-up and primary bone malignancy. Re-revision rates following a revision PFEPR was 34.3%, with dual-mobility bearings having the lowest rate of instability and re-revision (15.4%). Conclusion. Hemiarthroplasty and arthroplasty PFEPRs carry the same risk of revision in the medium term, and is primarily due to acetabular complications. There is no difference in revision rates or erosion between monopolar and bipolar hemiarthroplasties. The main causes of failure were acetabular wear in the hemiarthroplasty group and instability in the arthroplasty group. These risks should be balanced and patient prognosis considered when contemplating the bearing choice. Dual-mobility, constrained bearings, or large diameter heads (> 32 mm) are recommended in all revision PFEPRs. Cite this article: Bone Joint J 2021;103-B(10):1633–1640


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 190 - 190
1 Mar 2006
David L Blunn G Cannon S Briggs T
Full Access

Introduction: Total femoral endoprosthetic replacement can be an alternative to amputation following extensive tumour excision or in cases of severe bone loss. In skeletally immature patients the problem of leg length inequality may be overcome by the use of extendable prostheses. The aim of this study is to assess the functional outcome of patients following total femoral endoprosthetic replacement. Methods: This is a retrospective, single centre study of 16 patients who underwent consecutive total femoral replacements between 1978 and 1999. Information was collected from the Bone Tumour database, medical records and clinical review. The prostheses were custom made by the Biomedical Engineering Department of University College London and Stanmore Implants Worldwide. The implants are composed of a Titanium alloy shaft with Cobalt-Chrome bearing surfaces, incorporating a SMILES (Stanmore Modular Individualised Lower Extremity System) knee joint. Outcome was assessed using the Musculoskeletal Tumour Society (MTS) rating score. Sample: Eight patients were male and eight female. Mean age was 35 years (range 5–75 years). Ten patients underwent total femoral replacement as a primary procedure; nine for malignant tumour and one for hydatid disease. Of the patients with malignancy five had metastases at the time of presentation. The other indications were failed distal femoral replacement in four cases and periprosthetic fractures in the remaining two. Four children received extendable prostheses. Results: Of the patients with malignant disease, all but one had complete tumour excision. Three patients developed local recurrence. Two patients died of metastases within one year of diagnosis and three more died within five years. Three required revision procedures. Two more dislocated at the hip joint. Other complications included infection and lymphoedema. In patients surviving longer than one year the average range of motion at the hip was 85 degrees and at the knee 80 degrees. Using the MTS rating score the mean functional outcome was 60% of normal (range 27–90%). Of the survivors one achieved an excellent result, five were good, four fair and one poor. Conclusion: Total femoral endoprosthetic replacement can be effective in limb salvage and provide an alternative to amputation. Good functional results can often be achieved. However, the complication rate is high and the outcome extremely varied


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims. The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). Patients and Methods. In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors. Results. The revision-free survival of the implant was 71% at five years and 63.3% at ten years. Three prostheses reached 15 years without revision. The mean Musculoskeletal Tumor Society score in the group was 26 (23 to 28). The mechanisms of failure were infection in 18%, structural failures in 6%, tumour progression in 5%, aseptic loosening in 2%, and soft-tissue failures in 1%. Prostheses used for primary reconstruction after oncological resections had lower infection rates than revision implants (8% vs 25%; p = 0.001). The rates of infection in silver-coated and non-silver-coated prosthesis were similar (17.4% vs 19.%; p = 0.869). The incidence of hip dislocation was 10%. Rotating hinge prosthesis had a lower failure rate than fixed hinge prosthesis (5.3% vs 11%). After Cox regression, the independent factors associated with failures were the history of previous operations (hazard ratio (HR) 3.7; p = 0.041), and the associated arthroplasty of the proximal tibia (HR 3.8; p = 0.034). At last follow-up, 11 patients (13%) required amputation. Conclusion. TFEPR offers a reliable reconstruction option for massive bone loss of the femur, with a good survival when the prosthesis is used as a primary implant. The use of a rotating hinge at the knee and dual mobility bearing at the hip may be adequate to reduce the risk of mechanical and soft-tissue failures. Infection remains the main concern and there is insufficient evidence to support the routine use of silver-coated endoprosthesis. Cite this article: Bone Joint J 2019;101-B:522–528


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 717 - 722
1 Jul 2003
Kumar D Grimer RJ Abudu A Carter SR Tillman RM

We studied 100 patients who had undergone endoprosthetic replacement of the proximal humerus between 1976 and 1998. The outcome was assessed with regard to the survivorship of the patients, the salvaged limbs and the prostheses. Function was determined in the 47 surviving patients, of whom 30 were assessed using the Musculo-Skeletal Tumour Society (MSTS) rating scale and 38 completed the Toronto Extremity Salvage Score (TESS) questionnaire. The median age of the patients was 34 years (10 to 80). The mean follow-up period for surviving patients was nine years (2 to 20). The mean MSTS score at follow-up was 79% and the mean TESS score was 72%. The length of bone which was resected influenced the functional outcome. Abduction of the shoulder was to 45° in most patients. The overall survival was 42% at ten years and that of the limb without amputation 93%. The survival of the prostheses using mechanical failure as the endpoint was 86.5% at 20 years. Endoprosthetic replacement of the proximal humerus is a predictable procedure providing reasonable function of the arm with a low rate of complications at long-term follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 708 - 710
1 May 2011
Gaston CL Tillman RM Grimer RJ

We report a case of spontaneous physeal growth arrest of the distal femur in a nine-year-old child with Ewing’s sarcoma of the proximal femur treated with chemotherapy and endoprosthetic replacement. Owing to the extent of disuse osteoporosis at the time of surgery, the entire intramedullary canal up to the distal femoral physis was filled with cement. Three years later, the femur remained at its pre-operative length of 19 cm. Pre-operative calculations of further growth failed to account for the growth arrest, and the initial expandable growing prosthesis inserted has been revised to a longer one in order to address the leg-length discrepancy. To our knowledge, this is the only reported case of distal femoral physeal growth arrest following cemented endoprosthetic replacement of the proximal femur


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 521 - 526
1 Apr 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the distal femur after resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database, review of the design of the implant and case records. In total, 335 patients underwent a distal femoral replacement, 162 having a fixed-hinge design and 173 a rotating-hinge. The median age of the patients was 24 years (interquartile range 17 to 48). A total of 192 patients remained alive with a mean follow-up of 12 years (5 to 30). The risk of revision for any reason was 17% at five years, 33% at ten years and 58% at 20 years. Aseptic loosening was the main reason for revision of the fixed-hinge knees while infection and fracture of the stem were the most common for the rotating-hinge implant. The risk of revision for aseptic loosening was 35% at ten years with the fixed-hinge knee, which has, however, been replaced by the rotating-hinge knee with a hydroxyapatite collar. The overall risk of revision for any reason fell by 52% when the rotating-hinge implant was used. Improvements in the design of distal femoral endoprostheses have significantly decreased the need for revision operations, but infection remains a serious problem. We believe that a cemented, rotating-hinge prosthesis with a hydroxyapatite collar offers the best chance of long-term survival of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 240 - 243
1 Mar 2003
Kulkarni A Fiorenza F Grimer RJ Carter SR Tillman RM

Ten patients underwent endoprosthetic replacement of the distal humerus for bone tumours over a period of 30 years. There were eight primary and two secondary tumours in four men and six women with a mean age of 47.5 years (15 to 76). The mean follow-up was eight years (9 months to 31 years). Four patients required further surgery, three having revision for aseptic loosening; two of these and one other later needing a rebushing. There were no cases of postoperative nerve palsy, infection, local recurrence or mechanical failure of the implant. Four patients died from their disease, all with the prosthesis functioning satisfactorily. At follow-up the mean flexion deformity of the elbow was 15° (0 to 35) and the mean range of flexion was 115° (110 to 135). The functional results showed a mean Toronto extremity salvage score of 73% of normal. Endoprosthetic replacement of the distal humerus and elbow is a satisfactory method of treating these rare tumours


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 290 - 290
1 May 2006
Srikanth K Revell M Abudu A Carter S Tillmann R Grimer R
Full Access

Purpose: The aim of this study was to understand the effect of endoprosthetic reconstruction in treatment of solitary bone plasmacytoma threatening structural integrity of bone. Materials and methods: We retrospectively studied 11 patients who underwent endoprosthetic reconstruction for solitary bone plasmacytoma between 1988 and 2003 with more than 1 year follow up. Most had radiotherapy and those who sustained structural damage to a joint or thought to be salvageable were treated with endoprosthetic replacement. Results: There were 7 males and 4 females, with M: F ratio of 1.75:1, the median age at diagnosis was 53.61years (35–74). Average duration of symptoms prior to presentation at oncology unit was 7.27 months. We had 4 proximal femoral, 2 pelvic, 4 humeral and one tibial Plasmacytomas that were treated with endoprosthetic replacements.8/11 had preoperative radiotherapy for at least 4weeks and 3 did not. Two had postoperative radiotherapy and one adjuvant chemotherapy. Average follow up is 5.45 years (range 1–16years). We had one death due to unrelated causes, one progression to Myeloma treated with adjuvant chemotherapy, two revisions and one dislocation which was reduced by open method. The cumulative overall survival for all patients was 91% at 5 years. The cumulative risk of failure of reconstruction including; infection, dislocation, local recurrence/progression to Myeloma was 27% at 5 years. Conclusion: Literature review shows that nearly 53% of SBP progress despite radiotherapy to Myeloma at a median time of 1.8 years (2–4 years). But despite average follow up of 5.45 years, progression to Myeloma after endoprosthetic replacement at our unit is 9.09%. We concluded that the use of endoprostheses for reconstruction after excision of solitary bone plasmacytomas threatening structural integrity of bone combined with radiotherapy decreases the disease progression to Myeloma than radiotherapy alone and offers a reasonable but not absolute chance of cure


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 401 - 404
1 Mar 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Jeys LM

We undertook a cemental unipolar proximal femoral endoprosthetic replacement in 131 patients with a mean age of 50 years (2 to 84). Primary malignant tumours were present in 54 patients and 67 had metastatic disease. In addition, eight patients had either lymphoma or myeloma and two had non-oncological disorders. The mean follow-up was 27 months (0 to 180). An acetabular revision was required later in 14 patients, 12 of whom had been under the age of 21 years at the time of insertion of their original prosthesis. The risk of acetabular revision in patients over 21 years of age was 8% at five years compared with 36% in those aged under 21 years. All the unipolar hips in this younger age group required revision within 11 years of the initial operation. We conclude that unipolar replacement should not be used in younger patients and should be avoided in patients with a life expectancy of more than five years


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1632 - 1637
1 Dec 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and infection in the current version. The risk of revision for aseptic loosening in the fixed-hinge knees was 46% at ten years. This was reduced to 3% in the rotating-hinge knee with a hydroxyapatite collar. The cemented, rotating hinge design currently offers the best chance of long-term survival of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 219 - 224
1 May 1981
Dobbs H Scales J Wilson J Kemp H Burrows H Sneath R

A series of 81 patients has been reviewed to determine the value of endoprosthetic replacement of the proximal femur and hip in the treatment of bone tumours. Standard statistical methods were used to evaluate the survival of the replacements and the patients. Taking removal of the prosthesis, irrespective of the cause, as the criterion for failure the survival of the replacements was found to be 63 per cent after 10 years. If deaths are regarded as failures, then the survival value falls to 48 per cent. The survival of patients with chondrosarcoma and osteoclastoma treated by endoprosthetic replacement compares favourably with survival after amputation or excision of the tumour


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1352 - 1355
1 Oct 2007
Jeys LM Luscombe JS Grimer RJ Abudu A Tillman RM Carter SR

Between 1966 and 2001, 1254 patients underwent excision of a bone tumour with endoprosthetic replacement. All patients who had radiotherapy were identified. Their clinical details were retrieved from their records. A total of 63 patients (5%) had received adjunctive radiotherapy, 29 pre-operatively and 34 post-operatively. The mean post-operative Musculoskeletal Tumor Society scores of irradiated patients were significantly lower (log-rank test, p = 0.009). The infection rate in the group who had not been irradiated was 9.8% (117 of 1191), compared with 20.7% (6 of 29) in those who had pre-operative radiotherapy and 35.3% (12 of 34) in those who radiotherapy post-operatively. The infection-free survival rate at ten years was 85.5% for patients without radiotherapy, 74.1% for those who had pre-operative radiotherapy and 44.8% for those who had post-operative radiotherapy (log-rank test, p < 0.001). The ten-year limb salvage rate was 89% for those who did not have radiotherapy and 76% for those who did (log-rank test, p = 0.02). Radiotherapy increased the risk of revision (log-rank test, p = 0.015). A total of ten amputations were necessary to control infection, of which nine were successful. Radiotherapy may be necessary for the treatment of a bone sarcoma but increases the risk of deep infection for which amputation may be the only solution


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1498 - 1503
1 Nov 2007
Hanna SA David LA Aston WJS Gikas PD Blunn GW Cannon SR Briggs TWR

Between 1988 and 2006, 18 patients had a custom-made endoprosthetic replacement of the distal humerus for bone tumours at our institution. There were 11 primary malignant neoplasms, six secondary deposits, and one benign aggressive tumour. The mean follow-up was for 4.4 years (1 to 18.2). Complications occurred in nine patients and included aseptic loosening in three (16.6%), local recurrence in two (11%), infection in two (11%), neuropraxia of the radial nerve in one (5.5%) and a peri-prosthetic fracture in one (5.5%). Excision was inadequate in four patients (22%), all of which developed local recurrence and/or metastases. There were seven deaths from the primary disease after a mean of 2.3 years (1 to 5), one of whom had an above-elbow amputation for local recurrence seven months before death. The remaining six had satisfactory elbow function at their last follow-up. The 11 living patients were evaluated using the Musculoskeletal Tumour Society and Toronto Extremity Salvage scoring systems. The mean scores achieved were 76% (67% to 87%) and 73% (59% to 79%), respectively. Overall, 17 of 18 patients had significant improvement in the degree of their pain following operation. Custom-made endoprosthetic reconstruction of the elbow for bone tumours is a viable treatment in carefully selected patients. It maintains satisfactory function and provides good pain relief


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 234 - 234
1 Mar 2003
Foukas AF Jane MJ Journeaux SF
Full Access

We report the use of contained impacted morsellized allograft to revise an aseptically loose, massive distal femoral endoprosthetic replacement in a 27-year old Caucasian lady. The prosthesis was inserted 4 years earlier, following neo-adjuvant chemotherapy and resection of a distal femoral high grade osteosarcoma. Impaction grafting was used to restore bone stock and maintain femoral length. The patient remains disease-free, with excellent function, at two years after revision with no evidence of loosening and maintenance of bone stock. This is the first time this technique has been used in revision of a distal femoral endoprosthetic replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 656 - 661
1 Aug 1987
Ross A Wilson J Scales J

Endoprosthetic replacement of the proximal humerus has been performed in our unit on 25 occasions between 1950 and 1982. The indication for surgery was destruction of the proximal half of the humerus so extensive that the only alternatives were reconstruction or amputation. Of the patients with tumours two died from metastases, and three from unrelated causes; local recurrence necessitated amputation in two patients. Minor complications were frequent, but there were no deep infections and, after 1964, no prosthesis became loose. Active shoulder movement after operation was considerably limited, but passive movement was good and function of the elbow and hand were preserved


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 488 - 494
1 May 1999
Grimer RJ Carter SR Tillman RM Sneath RS Walker PS Unwin PS Shewell PC

We have performed endoprosthetic replacement after resection of tumours of the proximal tibia on 151 patients over a period of 20 years. During this period limb-salvage surgery was achieved in 88% of patients with tumours of the proximal tibia. Both the implant and the operative technique have been gradually modified in order to reduce complications. An initial rate of infection of 36% has been reduced to 12% by the use of a flap of the medial gastrocnemius, to which the divided patellar tendon is attached. Loosening and breakage of the implant have been further causes of failure. We found that the probability of further surgical procedures being required was 70% at ten years and the risk of amputation, 25%. The development of a new rotating hinge endoprosthesis may lower the incidence of mechanical problems. Limb salvage for tumours of the proximal tibia is fraught with complications, but the good functional outcome in successful cases justifies its continued use


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 112 - 113
1 Feb 2003
Kumar D Grimer RJ Tillman RM Carter SR
Full Access

Reconstruction of the shoulder joint following resection of the proximal humerus for bone tumours remains controversial. We report the long term functional results of the simplest form of reconstruction – an endoprosthesis. One hundred patients underwent endoprosthetic replacement of the proximal humerus between 1976 and 1998. Thirty eight had osteosarcoma, 17 had chondrosarcoma, 16 had metastases and 9 had Ewing’s sarcoma. Mean age was 36 years (range 10 to 80 yrs). Survivorship of patients and prostheses were calculated. Function was assessed using the Musculoskeletal tumour society (MSTS) and Toronto extremity salvage (TESS) scoring systems. Thirty patients could come to the clinics for MSTS scoring and 38 out of 49 alive patients replied to the TESS questionnaires sent out to them. The overall survival of the patients was 42% at 10 years. Local recurrence (LR) arose in 16 patients, being most common in chondrosarcoma (26%) and osteosarcoma (22%) and arose in 50% of patients with these tumours who had marginal excisions. Of these 16 patients, 8 had forequarter amputations whilst the remainder had excisions and radiotherapy. Mean time to LR was 12 months and all but two of these 16 patients subsequently died within a mean of 18 months. The prostheses proved reliable and dependable. Only 9 required further surgery of any sort, 2 needing minor surgery to correct subluxation and 7 needing revisions, one for infection after radiotherapy and six for loosening – three after trauma. The survivorship of the prosthesis without any further surgery was 86. 5% at 20years. The survivorship of the limb without amputation was 93% at 20 years. The functional outcome was very predictable. Most patients had only 45 degrees of abduction although three patients had normal movements. The mean MSTS functional score was 79% and the mean TESS score was also 79%. There was a high level of patient satisfaction but difficulty was encountered especially in lifting and in all activities above shoulder height. Endoprosthetic replacement of the proximal humerus is a predictable procedure providing reasonable function of the arm below shoulder height. The endoprostheses have proved highly dependable with a low re-operation rate. There is a high risk of local recurrence after inadequate surgery which should be avoided if possible


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 64 - 64
1 Mar 2010
Sewell M Spiegelberg B Hanna S Aston W Cannon S Briggs T
Full Access

Introduction: Total femoral endoprosthetic replacement can be used as an alternative to hip disarticulation following extensive tumour excision or in cases of more severe bone loss. To date there have been no long term studies on the oncological and functional outcome of patients who have had this procedure for malignant bone disease. We report our experience of over 25 years employing this procedure using a custom-made and modular total femoral endoprosthetic replacement. Methods: This is a retrospective, single centre study of 27 patients who underwent consecutive total femoral replacement as a primary procedure between 1978 and 2005. Information was collected from the bone tumour database, medical records and clinic review. Outcome was assessed using the Musculoskeletal Tumour Society (MSTS) rating score, the Harris Hip Score (HHS) and the Oxford Knee Score (OKS). Results: There were 15 males and 12 females, with a mean age of 30 years (5 to 65). The overall mean follow-up was 4.3 years (1 to 16.4) for all patients, 9.1 years (1 to 16.4) for the 7 patients who were alive at the time of this review, and 2.6 years (1 to 13) for the 20 patients who had died. 24 patients had primary malignant bone tumours of the femur and 3 had metastatic disease from a known primary elsewhere. 3 patients developed local recurrence, 1 patient developed new lung metastases. Mean MSTS score was 63% (19/30), mean HHS was 68/100 and mean OKS was 34/48. Discussion: Total femoral replacement can be an effective alternative to hip disarticulation in patients with malignant bone disease. Good functional outcomes can be achieved without compromising survival