Advertisement for orthosearch.org.uk
Results 1 - 20 of 76
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1550 - 1556
1 Dec 2019
Mc Colgan R Dalton DM Cassar-Gheiti AJ Fox CM O’Sullivan ME

Aims. The aim of this study was to examine trends in the management of fractures of the distal radius in Ireland over a ten-year period, and to determine if there were any changes in response to the English Distal Radius Acute Fracture Fixation Trial (DRAFFT). Patients and Methods. Data was grouped into annual intervals from 2008 to 2017. All adult inpatient episodes that involved emergency surgery for fractures of the distal radius were included. Results. In 2008 Kirschner-wire (K-wire) fixation accounted for 59% of operations for fractures of the distal radius, and plate fixation for 21%. In 2017, the rate of K-wire fixation had fallen to 30%, and the proportion of patients who underwent plate fixation had risen to 62%. Conclusion. There is an increasing trend towards open reduction and internal fixation for fractures of the distal radius in Ireland. This has been accompanied by a decrease in popularity for K-wire fixation. DRAFFT did not appear to influence trends in the management of fractures of the distal radius in Ireland. Cite this article: Bone Joint J 2019;101-B:1550–1556


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 963 - 969
1 Jul 2014
Mellstrand-Navarro C Pettersson HJ Tornqvist H Ponzer S

The aim of this study was to investigate the epidemiology of fractures of the distal radius in the Swedish population and to review the methods used to treat them between 2005 and 2010. The study population consisted of every patient in Sweden who was diagnosed with a fracture of the wrist between 1 January 2005 and 31 December 2010. There were 177 893 fractures of the distal radius. The incidence rate in the total population was 32 per 10 000 person-years. The mean age of the patients was 44 years (0 to 104). The proportion of fractures treated operatively increased from 16% in 2005 to 20% in 2010. The incidence rate for plate fixation in the adult population increased 3.61 fold. The incidence rate for external fixation decreased by 67%. The change was greatest in the 50 years to 74 years age group. In Sweden, there is an increasing tendency to operate on fractures of the distal radius. The previously reported increase in the use of plating is confirmed: it has increased more than threefold over a five-year period. Cite this article: Bone Joint J 2014;96-B:963–9


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 841 - 843
1 Jun 2005
Zamzam MM Khoshhal KI

We retrospectively reviewed 183 children with a simple fracture of the distal radius, with or without fracture of the ulna, treated by closed reduction and cast immobilisation. The fracture redisplaced after an initial, acceptable closed reduction in 46 (25%). Complete initial displacement was identified as the most important factor leading to redisplacement. Other contributing factors were the presence of an ipsilateral distal ulnar fracture, and the reduction of completely displaced fractures under deep sedation or local haematoma block. We recommend that completely displaced fractures of the distal radius in children should be reduced under general anaesthesia, and fixed by primary percutaneous Kirschner wires even when a satisfactory closed reduction has been achieved


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 837 - 840
1 Jun 2005
Azzopardi T Ehrendorfer S Coulton T Abela M

We performed a prospective, randomised study on 57 patients older than 60 years of age with unstable, extra-articular fractures of the distal radius to compare the outcome of immobilisation in a cast alone with that using supplementary, percutaneous pinning. Patients treated by percutaneous wires had a statistically significant improvement in dorsal angulation (mean 7°), radial length (mean 3 mm) and radial inclination (mean 3 mm) at one year. However, there was no significant difference in functional outcome in terms of pain, range of movement, grip strength, activities of daily living and the SF-36 score except for an improved range of movement in ulnar deviation in the percutaneous wire group. One patient developed a pin-track infection which required removal of the wires at two weeks. We conclude that percutaneous pinning of unstable, extra-articular fractures of the distal radius provides only a marginal improvement in the radiological parameters compared with immobilisation in a cast alone. This does not correlate with an improved functional outcome in a low-demand, elderly population


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 404 - 409
1 May 1996
McQueen MM Hajducka C Court-Brown CM

We performed a prospective, randomised trial on 120 patients with redisplaced fractures of the distal radius comparing four methods of treatment. The four treatment groups, each containing 30 patients, were remanipulation and plaster, open reduction and bone grafting, and closed external fixation with and without mobilisation of the wrist at three weeks. The radiological results showed improvement in angulation of the distal radius for the open reduction and bone grafting group. Functional results at six weeks, three and six months and at one year, however, showed no difference between any of the four groups. The main influence on final outcome was carpal malalignment which had a statistically significant negative effect on function


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 665 - 669
1 Jul 1998
McQueen MM

A randomised, prospective study was carried out on 60 patients with unstable fractures of the distal radius to compare bridging with non-bridging external fixation using pins placed in the distal fragment of the radius. The radiological results showed significant improvement in the non-bridging group at all stages of review. In particular, normal volar tilt and carpal alignment were regained and maintained. The functional results at six weeks, three months, six months and one year showed statistically better grip strength and flexion in the non-bridging group at all stages of review. Other ranges of movement showed an early advantage in the non-bridging group. Non-bridging external fixation is the treatment of choice for unstable fractures of the distal radius which have sufficient space for the placement of pins in the distal fragment


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 778 - 785
1 Jun 2008
Varitimidis SE Basdekis GK Dailiana ZH Hantes ME Bargiotas K Malizos K

In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant. Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 102 - 107
1 Jan 2009
Zenke Y Sakai A Oshige T Moritani S Nakamura T

A total of 118 consecutive patients with a fracture of the distal radius were treated with a volar locking plate; 50 patients had no ulnar styloid fracture, 41 had a basal ulnar styloid fracture, and 27 had a fracture of the tip of the ulnar styloid. There were no significant differences in radiological and clinical results among the three groups. The outcome was good and was independent of the presence of a fracture of the ulnar styloid. A total of five patients (4.2%) had persistent ulnar-sided wrist pain at final follow-up. Nonunion of the ulnar styloid fracture did not necessarily lead to ulnar wrist pain. Patients with persistent ulnar pain had a higher mean initial ulnar variance and increased post-operative loss of ulnar variance. The presence of an associated ulnar styloid fracture of the ulnar styloid does not adversely affect the outcome in patients with a fracture of the distal radius treated by volar plating


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 629 - 637
1 May 2008
Forward DP Davis TRC Sithole JS

Fractures of the distal radius occurring in young adults are treated increasingly by open surgical techniques, partly because of concern that failure to restore the alignment of the fracture accurately may cause symptomatic post-traumatic osteoarthritis in future years. We reviewed 106 adults who had sustained a fracture of the distal radius between 1960 and 1968 and who were below the age of 40 years at the time of injury. We carried out a clinical and radiological assessment at a mean follow-up of 38 years (33 to 42). No patient had required a salvage procedure. While there was radiological evidence of post-traumatic osteoarthritis after an intra-articular fracture in 68% of patients (27 of 40), the disabilities of the arm, shoulder and hand (DASH) scores were not different from population norms, and function, as assessed by the Patient Evaluation Measure, was impaired by less than 10%. Ordinal logistic regression analysis showed a significant relationship between narrowing of the joint space and extra-articular malunion (dorsal angulation and radial shortening) as well as intra-articular injury. Multivariate analysis revealed that grip strength had fallen to 89% of that of the uninjured side in the presence of dorsal malunion, but no measure of extra-articular malunion was significantly related to either the Patient Evaluation Measure or DASH scores. While anatomical reduction is the principal aim of treatment, imperfect reduction of these fractures may not result in symptomatic arthritis in the long term, and this should be considered when counselling patients on the risks and benefits of the many treatment options available


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 856 - 863
1 Aug 2000
Sanchez-Sotelo J Munuera L Madero R

We performed a prospective, randomised study on 110 patients more than 50 years old with fractures of the distal radius to compare the outcome of conservative treatment with that using remodellable bone cement (Norian skeletal repair system, SRS) and immobilisation in a cast for two weeks. Patients treated with SRS had less pain and earlier restoration of movement and grip strength. The results at one year were satisfactory in 81.54% of the SRS patients and 55.55% of the control group. The rates of malunion were 18.2% and 41.8%, respectively. There was a significant relationship between the functional and radiological results. Soft-tissue extrusion was present initially in 69.1% of the SRS patients; most deposits disappeared progressively, but persisted in 32.73% at one year. We conclude that the injection of a remodellable bone cement into the trabecular defect of fractures of the distal radius provides a better clinical and radiological result than conventional treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 670 - 672
1 Jul 1998
Flinkkilä T Nikkola-Sihto A Kaarela O Päakkö E Raatikainen T

Interobserver reliability of the AO system of classification of fractures of the distal radius was assessed using plain radiographs and CT. Five observers classified 30 Colles’-type fractures using only plain radiographs; two months later they were reclassified using CT in addition. Interobserver reliability was poor in both series when detailed classification was used. By reducing the categories to five, interobserver reliability was slightly improved, but was still poor. When only two AO types were used, the reliability was moderate using plain radiographs and good to excellent with the addition of CT. The use of CT as well as plain radiographs brings interobserver reliability to a good level in assessment of the presence or absence of articular involvement, but is otherwise of minor value in improving the interobserver reliability of the AO system of classification of fractures of the distal radius


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 972 - 976
1 Sep 2000
Wakefield AE McQueen MM

The capacity for physiotherapy to improve the outcome after fracture of the distal radius is unproven. We carried out a randomised controlled trial on 96 patients, comparing conventional physiotherapy with a regime of home exercises. The function of the upper limb was assessed at the time of removal of the plaster cast and at three and six months after injury. Factors which may predict poor outcome in these patients were sought. Grip strength and hand function did not significantly differ between the two groups. Flexion and extension of the wrist were the only movements to improve with physiotherapy at six months (p = 0.001). Predictors of poor functional outcome were malunion and impaired function before the fracture. These patients presented with pain, decreased rotation of the forearm and low functional scores at six weeks. Our study has shown that home exercises are adequate rehabilitation after uncomplicated fracture of the distal radius, and routine referral for a course of physiotherapy should be discouraged. The role of physiotherapy in patients at high risk of a poor outcome requires further investigation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 313 - 313
1 Sep 2012
Garg B Kotwal P
Full Access

Introduction. Scaphoid nonunions remain controversial with regard to optimal management. The objective of this article is to compare our clinical experience in the treatment of patients with scaphoid nonunion using distal radius non vascularised bone graft with that of iliac crest bone graft. Material & Methods. We conducted a prospective randomized study comparing the clinical, functional and radiographic results of 42 patients treated for scaphoid nonunion using a non-vascularised bone graft from the dorsal and distal aspect of the radius (group I), relative to 46 patients treated by means of a conventional non-vascularised bone graft from the iliac crest (group II). All nonunions were stabilized with single Herbert screw. Results. Bone fusion was achieved in 87.1% of group I and 86.5% of group II patients. Functional results were good to excellent in 76.0% of the patients in group I and 72.5% in group II. The average grip power, as well as wrist flexion and extension were similar in both groups. However, the donor site morbidity was much higher in group II (4 cases of hematoma, 6 cases of chronic pain and 1 anterior superior iliac spine avulsion) fracture. No complication was seen in group I. Conclusion. We conclude that nonvascularized distal radius bone grafting yields similar union rate as well as functional outcome as compared to iliac crest bone graft with no donor site morbidity


Bone & Joint Open
Vol. 3, Issue 8 | Pages 623 - 627
8 Aug 2022
Francis JL Battle JM Hardman J Anakwe RE

Aims. Fractures of the distal radius are common, and form a considerable proportion of the trauma workload. We conducted a study to examine the patterns of injury and treatment for adult patients presenting with distal radius fractures to a major trauma centre serving an urban population. Methods. We undertook a retrospective cohort study to identify all patients treated at our major trauma centre for a distal radius fracture between 1 June 2018 and 1 May 2021. We reviewed the medical records and imaging for each patient to examine patterns of injury and treatment. We undertook a binomial logistic regression to produce a predictive model for operative fixation or inpatient admission. Results. Overall, 571 fractures of the distal radius were treated at our centre during the study period. A total of 146 (26%) patients required an inpatient admission, and 385 surgical procedures for fractures of the distal radius were recorded between June 2018 and May 2021. The most common mechanism of injury was a fall from a height of one metre or less. Of the total fractures, 59% (n = 337) were treated nonoperatively, and of those patients treated with surgery, locked anterior-plate fixation was the preferred technique (79%; n = 180). Conclusion. The epidemiology of distal radius fractures treated at our major trauma centre replicated the classical bimodal distribution described in the literature. Patient age, open fractures, and fracture classification were factors correlated with the decision to treat the fracture operatively. While most fractures were treated nonoperatively, locked anterior-plate fixation remains the predominant method of fixation for fractures of the distal radius; this is despite questions and continued debate about the best method of surgical fixation for these injuries. Cite this article: Bone Jt Open 2022;3(8):623–627


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 829 - 836
1 Jun 2005
Kreder HJ Hanel DP Agel J McKee M Schemitsch EH Trumble TE Stephen D

A total of 179 adult patients with displaced intra-articular fractures of the distal radius was randomised to receive indirect percutaneous reduction and external fixation (n = 88) or open reduction and internal fixation (n = 91). Patients were followed up for two years. During the first year the upper limb musculoskeletal function assessment score, the SF-36 bodily pain sub-scale score, the overall Jebsen score, pinch strength and grip strength improved significantly in all patients. There was no statistically significant difference in the radiological restoration of anatomical features or the range of movement between the groups. During the period of two years, patients who underwent indirect reduction and percutaneous fixation had a more rapid return of function and a better functional outcome than those who underwent open reduction and internal fixation, provided that the intra-articular step and gap deformity were minimised


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 340 - 344
1 Apr 2000
Jakob M Rikli DA Regazzoni P

Stable fixation of fractures of the distal radius can be achieved by using two 2.0 mm titanium plates placed on the radial and intermediate columns angled 50° to 70° apart. We describe our results with this method in a prospective series of 74 fractures (58 severely comminuted) in 73 consecutive patients. Early postoperative mobilisation was possible in all except four wrists. All of the 73 patients, except two with other injuries, returned to work and daily activities with no limitations. The anatomical results were excellent or good in 72 patients and fair in one. Our discussion includes details of important technical considerations based on an analysis of the specific complications which were seen early in the series


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 42 - 42
1 Apr 2013
Medlock G Wohlgemut J Stevenson I Johnstone A
Full Access

Intro. Distal radial fractures are a commonly encountered fracture & anatomical reduction is the standard. Dorsal angulation is the traditional method of assessment but is inaccurate in rotated lateral xrays. Previously a relationship has been demonstrated between the dorsal cortex (DC) of the radius & the superior pole of the lunate (SL) & its sensitivity for assessing dorsal angulation & translation. Hypothesis. A constant anatomical relationship maintained between the DC and the SL when rotated up to 30 degrees from standard lateral?. Methods. MRI scans of 28 wrists including the distal third of the radius to the proximal carpal row. Beginning 5cm proximal to the distal radius articular surface, a line was superimposed upon the DC extending distally through the metaphysis. Lunate height (LH) & distance from the DC line to the SL (DC-SL) were measured at 5-degree rotational increments around the radial shaft central axis to 30 degrees of supination & pronation (S+P). The DC-SL/LH ratio was compared to 0 degrees (anatomical lateral) using the two-tailed paired student t-test. Results. No significant difference in DC-SL:LH between 0 degrees of rotation and any 5-degree increment up to 30 degrees of S+P (lowest p=0.075). The DC line lay consistently dorsal to the SL. Conclusion. A constant DC-SL relationship is maintained with up to 30 degrees of S+P. This reference can be quickly and accurately used to assess DRF reduction in poorly-taken films with malrotation


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1214 - 1221
1 Sep 2008
Egol K Walsh M Tejwani N McLaurin T Wynn C Paksima N

We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 346 - 346
1 Sep 2012
Baliga S Carnegie C Johnstone A
Full Access

Introduction. Several clinical and radiological studies have confirmed the benefits of using Volar Locking Plates (VLPs) to treat unstable distal radius fractures. The “theoretical” advantage of VLPs compared to standard plate fixation is that VLPs, through their design, intrinsically provide angular stability for most fracture configurations including comminuted fractures and, quite possibly, osteoporotic fractures. However few studies have compared the clinical results of patients of different ages who have been treated using VLPs. Aim. The aim of this study was to compare the clinical outcomes of VLP fixation of displaced distal radius in younger (<59 yrs) and older (>60yrs) patients. Patients & Methods. We reviewed 78 consecutive patients who had undergone ORIF of their displaced distal radial fractures using a VLP. All patients were reviewed at predetermined time points by an independent observer and the findings at 6 months are presented. In addition to documenting the standard demographics for each patient and classifying the fractures using the OTA/AO system, wrist function was assessed using Range of Movement (ROM), Grip strength (GS), the Modified Gartland & Werley score (MGWS), the Patient Rated Wrist Evaluation (PRWE), the Quick DASH scores, and overall scores of wrist Pain and Function using Visual Analogue Scores (VAS). Results. 43 patients were under 60 years of age and 35 patients were 60 years or over. The proportion of extra-articular to intra-articular fractures were similar for both age groups. There was little difference in terms of patient perception of Pain and Function, or ROM, MGWS (7.2 versus 6.9), PRWE (24 versus 23.6) and quick DASH scores (17.3 versus 19.1) between the two groups at 6 months. The younger group did have significantly better grip strength, but when compared as a percentage of the uninjured wrist, the results were also similar (83% vs 80%). Conclusions. VLPs are a suitable option for fixing distal radial fractures in older patients (>60yrs) and the clinical results appear to be just as good as they are in younger patients


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 87 - 87
1 Apr 2013
Yamazaki H Kitahara J Kodaira H Seino S Akaoka Y
Full Access

Background. The usefulness of arthroscopic reduction for the intra-articular fracture of the distal radius has been reported, although it is technically difficult. Hypothesis. Our hypothesis is that the reduction using the external fixator is useful as equivalent to the arthroscopic reduction for the intra-articular fracture of the distal radius fracture in the fixation with the volar locking plate. Materials & Methods. The surgery was performed in both methods randomly for 40 patients; average age 64(24 to 92) years, 11 male, 29 female. Image evaluations were performed at 24 weeks after surgery. Ulnar variance, Radial inclination, Volar tilt in the X-ray image, and gap and step in the computed tomogram were evaluated. Clinical evaluation was performed at 6, 12, 24 weeks after surgery. Objective evaluations were ranges of motion and grip strength. Subjective evaluations were disabilities of the arm, shoulder, and hand (DASH). Results. The results of image and objective evaluation had no significant difference between the two groups. DASH in arthroscopic group was significantly inferior at 24 weeks because of minor complications. Discussion & Conclusion. The external fixator and the arthroscopy are equally valuable in reduction of articular surface