Introduction. Hemiarthroplasty is a treatment option for comminuted fractures and non-unions of the distal humerus. Unfortunately, the poor anatomical fit of off-the-shelf
Aims. Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty,
This study reviews the early results of Distal Humeral Hemiarthroplasty(DHH) for distal humeral fracture and proposed a treatment algorithm incorporating the use of this technique in the overall management of distal humeral fractures. DHH was performed on 30 patients (mean 65 years; 29-91) for unreconstructable fractures of the distal humerus or salvage of failed internal fixation. A triceps on approach was used in six and an olecranon osteotomy in 24. A Sorbie Questor prosthesis (Wright Medical Technology) was used in 14 patients and a Latitude (Tornier) in 16. Clinical review at a mean of 25 months (3–88) included the American Shoulder and Elbow Surgeons elbow outcomes instrument (ASES), Mayo Elbow Performance Index (MEPI) and radiological assessment. At follow up of 28 patients mean flexion deformity was 25 degrees, flexion 128 degrees, range of pronosupination 165 degrees, mean ASES 83, MEPI 77 and satisfaction 8/10. Acute cases scored better than salvage cases. Re- operation was required in 16 patients (53%); two revisions to a linked prosthesis for periprosthetic fracture and aseptic loosening at 53 and 16 months, 12 metalwork removals and four ulnar nerve procedures. Posterolateral rotatory instability was present in one elbow, four had laxity and mild pain on loading (two with prosthesis or pin loosening), four had laxity associated with column fractures (two symptomatic) and 10 had asymptomatic mild laxity only. The triceps on approach had worse instability and clinical scores. Uncomplicated union occurred in all olecranon osteotomies and 86% of column fractures. One elbow had an incomplete cement mantle and seven had lucencies >1 mm; one was loose but acceptable. Five prostheses were in slight varus. Two elbows had early degenerative changes and 15 developed a medial spur on the trochlea. This is the largest reported experience of DHH. Early results of DHH show good outcomes after complex distal humeral fractures, despite a technically demanding procedure. Better results are obtained for treatment in the acute setting and with use of an olecranon osteotomy. As a result of this experience anatomical and clinical pre-requisites and advise on technique are outlined. An algorithm for use of DHH in relation to total elbow arthroplasty and ORIF for the treatment of complex intra-articular distal humeral fractures with or without column fractures is proposed.
A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement. A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings.Aims
Methods
The aim of this audit was to assess and improve the completeness and accuracy of the National Joint Registry (NJR) dataset for arthroplasty of the elbow. It was performed in two phases. In Phase 1, the completeness was assessed by comparing the NJR elbow dataset with the NHS England Hospital Episode Statistics (HES) data between April 2012 and April 2020. In order to assess the accuracy of the data, the components of each arthroplasty recorded in the NJR were compared to the type of arthroplasty which was recorded. In Phase 2, a national collaborative audit was undertaken to evaluate the reasons for unmatched data, add missing arthroplasties, and evaluate the reasons for the recording of inaccurate arthroplasties and correct them.Aims
Methods
The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes. We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis.Aims
Methods
The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.Aims
Methods
The June 2023 Shoulder & Elbow Roundup360 looks at: Proximal humerus fractures: what does the literature say now?; Infection risk of steroid injections and subsequent reverse shoulder arthroplasty; Surgical versus non-surgical management of humeral shaft fractures; Core outcome set needed for elbow arthroplasty; Minimally invasive approaches to locating radial nerve in the posterior humeral approach; Predictors of bone loss in anterior glenohumeral instability; Does the addition of motor control or strengthening exercises improve rotator cuff-related shoulder pain?; Terminology and diagnostic criteria used in patients with subacromial pain syndrome.
The aims of this study were to identify and evaluate the current literature examining the prognostic factors which are associated with failure of total elbow arthroplasty (TEA). Electronic literature searches were conducted using MEDLINE, Embase, PubMed, and Cochrane. All studies reporting prognostic estimates for factors associated with the revision of a primary TEA were included. The risk of bias was assessed using the Quality In Prognosis Studies (QUIPS) tool, and the quality of evidence was assessed using the modified Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. Due to low quality of the evidence and the heterogeneous nature of the studies, a narrative synthesis was used.Aims
Methods
The October 2015 Shoulder &
Elbow Roundup360 looks at: Culture time important in propionibacterium acnes; Microvascularisation of the cuff footprint; Degenerative cuff tears: evidence for repair; Middle ground in distal humeral fractures?; Haste needed in elbow heterotopic ossification; Iatrogenic frozen shoulder; Salvage of failed humeral fixation
In light of the growing number of elderly osteopenic
patients with distal humeral fractures, we discuss the history of
their management and current trends. Under most circumstances operative
fixation and early mobilisation is the treatment of choice, as it
gives the best results. The relative indications for and results
of total elbow replacement