Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 902 - 907
1 May 2021
Marson BA Ng JWG Craxford S Chell J Lawniczak D Price KR Ollivere BJ Hunter JB

Aims. The management of completely displaced fractures of the distal radius in children remains controversial. This study evaluates the outcomes of surgical and non-surgical management of ‘off-ended’ fractures in children with at least two years of potential growth remaining. Methods. A total of 34 boys and 22 girls aged 0 to ten years with a closed, completely displaced metaphyseal distal radial fracture presented between 1 November 2015 and 1 January 2020. After 2018, children aged ten or under were offered treatment in a straight plaster or manipulation under anaesthesia with Kirschner (K-)wire stabilization. Case notes and radiographs were reviewed to evaluate outcomes. In all, 16 underwent treatment in a straight cast and 40 had manipulation under anaesthesia, including 37 stabilized with K-wires. Results. Of the children treated in a straight cast, all were discharged with good range of mo (ROM). Five children were discharged at six to 12 weeks with no functional limitations at six-month follow-up. A total of 11 children were discharged between 12 and 50 weeks with a normal ROM and radiological evidence of remodelling. One child had a subsequent diaphyseal fracture proximal to the original injury four years after the initial fracture. Re-displacement with angulation greater than 10° occurred for 17 children who had manipulation under anaesthesia. Four had a visible cosmetic deformity at discharge and nine had restriction of movement, with four requiring physiotherapy. One child developed over- granulation at the pin site and one wire became buried, resulting in a difficult retrieval in clinic. No children had pin site infections. Conclusion. Nonoperative management of completely displaced distal radial fractures in appropriately selected cases results in excellent outcomes without exposing the child to the risks of surgery. This study suggests that nonoperative management of these injuries is a viable and potentially underused strategy. Cite this article: Bone Joint J 2021;103-B(5):902–907


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1264 - 1270
1 Sep 2015
Karantana A Scammell BE Davis TRC Whynes DK

This study compares the cost-effectiveness of treating dorsally displaced distal radial fractures with a volar locking plate and percutaneous fixation. It was performed from the perspective of the National Health Service (NHS) using data from a single-centre randomised controlled trial. In total 130 patients (18 to 73 years of age) with a dorsally displaced distal radial fracture were randomised to treatment with either a volar locking plate (n = 66) or percutaneous fixation (n = 64). The methodology was according to National Institute for Health and Care Excellence guidance for technology appraisals. . There were no significant differences in quality of life scores between groups at any time point in the study. Both groups returned to baseline one year post-operatively. . NHS costs for the plate group were significantly higher (p < 0.001, 95% confidence interval 497 to 930). For an additional £713, fixation with a volar locking plate offered 0.0178 additional quality-adjusted life years in the year after surgery. The incremental cost-effectiveness ratio (ICER) for plate fixation relative to percutaneous fixation at list price was £40 068. When adjusting the prices of the implants for a 20% hospital discount, the ICER was £31 898. Patients who underwent plate fixation did not return to work earlier. We found no evidence to support the cost-effectiveness, from the perspective of the NHS, of fixation using a volar locking plate over percutaneous fixation for the operative treatment of a dorsally displaced radial fracture. Cite this article: Bone Joint J 2015;97-B:1264–70


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 346 - 346
1 Sep 2012
Baliga S Carnegie C Johnstone A
Full Access

Introduction. Several clinical and radiological studies have confirmed the benefits of using Volar Locking Plates (VLPs) to treat unstable distal radius fractures. The “theoretical” advantage of VLPs compared to standard plate fixation is that VLPs, through their design, intrinsically provide angular stability for most fracture configurations including comminuted fractures and, quite possibly, osteoporotic fractures. However few studies have compared the clinical results of patients of different ages who have been treated using VLPs. Aim. The aim of this study was to compare the clinical outcomes of VLP fixation of displaced distal radius in younger (<59 yrs) and older (>60yrs) patients. Patients & Methods. We reviewed 78 consecutive patients who had undergone ORIF of their displaced distal radial fractures using a VLP. All patients were reviewed at predetermined time points by an independent observer and the findings at 6 months are presented. In addition to documenting the standard demographics for each patient and classifying the fractures using the OTA/AO system, wrist function was assessed using Range of Movement (ROM), Grip strength (GS), the Modified Gartland & Werley score (MGWS), the Patient Rated Wrist Evaluation (PRWE), the Quick DASH scores, and overall scores of wrist Pain and Function using Visual Analogue Scores (VAS). Results. 43 patients were under 60 years of age and 35 patients were 60 years or over. The proportion of extra-articular to intra-articular fractures were similar for both age groups. There was little difference in terms of patient perception of Pain and Function, or ROM, MGWS (7.2 versus 6.9), PRWE (24 versus 23.6) and quick DASH scores (17.3 versus 19.1) between the two groups at 6 months. The younger group did have significantly better grip strength, but when compared as a percentage of the uninjured wrist, the results were also similar (83% vs 80%). Conclusions. VLPs are a suitable option for fixing distal radial fractures in older patients (>60yrs) and the clinical results appear to be just as good as they are in younger patients


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 503 - 507
1 Apr 2017
White TO Mackenzie SP Carter TH Jefferies JG Prescott OR Duckworth AD Keating JF

Aims

Fracture clinics are often characterised by the referral of large numbers of unselected patients with minor injuries not requiring investigation or intervention, long waiting times and recurrent unnecessary reviews. Our experience had been of an unsustainable system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order to rationalise and regulate access to our fracture service. The British Orthopaedic Association’s guidelines have required a prospective evaluation of this change of practice, and we report our experience and results.

Patients and Methods

We review the management of all 12 069 patients referred to our service in the calendar year 2014, with a minimum of one year follow-up during the calendar year 2015.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 410 - 413
1 Mar 2016
Costa ML Jameson SS Reed MR

Aims

Our aim, using English Hospital Episode Statistics data before during and after the Distal Radius Acute Fracture Fixation Trial (DRAFFT), was to assess whether the results of the trial affected clinical practice.

Patients and Methods

Data were grouped into six month intervals from July 2005 to December 2014. All patient episodes in the National Health Service involving emergency surgery for an isolated distal radial fracture were included.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 817 - 823
1 Jun 2011
Solomon LB Callary SA Stevenson AW McGee MA Chehade MJ Howie DW

We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured −0.30 mm (−0.73 to 0.02) at two weeks and 0.00 mm (−0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was −0.34 mm (−1.64 to 1.51).

Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 841 - 843
1 Jun 2005
Zamzam MM Khoshhal KI

We retrospectively reviewed 183 children with a simple fracture of the distal radius, with or without fracture of the ulna, treated by closed reduction and cast immobilisation. The fracture redisplaced after an initial, acceptable closed reduction in 46 (25%). Complete initial displacement was identified as the most important factor leading to redisplacement. Other contributing factors were the presence of an ipsilateral distal ulnar fracture, and the reduction of completely displaced fractures under deep sedation or local haematoma block. We recommend that completely displaced fractures of the distal radius in children should be reduced under general anaesthesia, and fixed by primary percutaneous Kirschner wires even when a satisfactory closed reduction has been achieved.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1065 - 1070
1 Aug 2006
Appleton P Moran M Houshian S Robinson CM

Although the use of constrained cemented arthroplasty to treat distal femoral fractures in elderly patients has some practical advantages over the use of techniques of fixation, concerns as to a high rate of loosening after implantation of these prostheses has raised doubts about their use. We evaluated the results of hinged total knee replacement in the treatment of 54 fractures in 52 patients with a mean age of 82 years (55 to 98), who were socially dependent and poorly mobile.

Within the first year after implantation 22 of the 54 patients had died, six had undergone a further operation and two required a revision of the prosthesis. The subsequent rate of further surgery and revision was low.

A constrained knee prosthesis offers a useful alternative treatment to internal fixation in selected elderly patients with these fractures, and has a high probability of surviving as long as the patient into whom it has been implanted.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1214 - 1221
1 Sep 2008
Egol K Walsh M Tejwani N McLaurin T Wynn C Paksima N

We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities.

Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups.

No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group.