Advertisement for orthosearch.org.uk
Results 1 - 20 of 285
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1745 - 1753
1 Dec 2021
Walinga AB Stornebrink T Langerhuizen DWG Struijs PAA Kerkhoffs GMMJ Janssen SJ

Aims. This study aimed to answer two questions: what are the best diagnostic methods for diagnosing bacterial arthritis of a native joint?; and what are the most commonly used definitions for bacterial arthritis of a native joint?. Methods. We performed a search of PubMed, Embase, and Cochrane libraries for relevant studies published between January 1980 and April 2020. Of 3,209 identified studies, we included 27 after full screening. Sensitivity, specificity, area under the curve, and Youden index of diagnostic tests were extracted from included studies. We grouped test characteristics per diagnostic modality. We extracted the definitions used to establish a definitive diagnosis of bacterial arthritis of a native joint per study. Results. Overall, 28 unique diagnostic tests for diagnosing bacterial arthritis of a native joint were identified. The following five tests were deemed most useful: serum ESR (sensitivity: 34% to 100%, specificity: 23% to 93%), serum CRP (sensitivity: 58% to 100%, specificity: 0% to 96%), serum procalcitonin (sensitivity: 0% to 100%, specificity: 68% to 100%), the proportion of synovial polymorphonuclear cells (sensitivity: 42% to 100%, specificity: 54% to 94%), and the gram stain of synovial fluid (sensitivity: 27% to 81%, specificity: 99% to 100%). Conclusion. Diagnostic methods with relatively high sensitivities, such as serum CRP, ESR, and synovial polymorphonuclear cells, are useful for screening. Diagnostic methods with a relatively high specificity, such as serum procalcitonin and synovial fluid gram stain, are useful for establishing a diagnosis of bacterial arthritis. This review helps to interpret the value of various diagnostic tests for diagnosing bacterial arthritis of a native joint in clinical practice. Cite this article: Bone Joint J 2021;103-B(12):1745–1753


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 61 - 61
1 Dec 2018
Loppini M Traverso F Ferrari MC Avigni R Leone R Bottazzi B Mantovani A Grappiolo G
Full Access

Aim. Diagnosis of periprosthetic joint infection (PJI) is challenging given the limitations of available diagnostic tests. Recently, several studies have shown a role of the long pentraxin PTX3 as a biomarker in inflammatory diseases and infections. This single-center prospective diagnostic study evaluated the diagnostic ability of synovial fluid and serum PTX3 for the infection of total hip arthroplasty (THA) and total knee arthroplasty (TKA). Method. Consecutive patients undergoing revision surgery for painful THA or TKA were enrolled. Patients with antibiotic therapy suspended for less than 2 weeks prior to surgery and patients eligible for metal-on-metal implant revision or spacer removal and prosthesis re-implantation were excluded. Quantitative assessment of synovial fluid and serum PTX3 was performed with ELISA method. Musculoskeletal Infection Society (MSIS) criteria were used as reference standard for diagnosis of PJI. Continuous data values were compared for statistical significance with univariate unpaired, 2-tailed Student's t-tests. Receiver operating characteristic (ROC) curve analyses was performed to assess the ability of serum and synovial fluid PTX3 concentration to determine the presence of PJI. Youden's J statistic was used to determine optimum threshold values for the diagnosis of infection. Sensitivity (Se), specificity (Sp), positive (PPV) and negative (NPV) predictive values, positive (LR+) and negative (LR-) likelihood ratio, area under the ROC curve (AUC) were calculated. Results. One-hundred fifteen patients (M:F=49:66) with a mean age of 62 years (40–79) underwent revision of THA (n=99) or TKA (n=16). According with MSIS criteria, 18 cases were categorized as septic and 97 as aseptic revisions. The average synovial fluid concentration of PTX3 was significantly higher in patients with PJI compared to patients undergoing aseptic revision (24,3 ng/dL vs 3,64 ng/dL; P=0.002). There was no significant difference in terms of serum concentration of PTX3 between the two groups. Synovial fluid PTX3 demonstrated an AUC of 0.96 (95%IC 0.89–0.98) with Se 94%, Sp 90%, PPV 67%, NPV 100%, LR+ 9.4 and LR- 0.06 for a threshold value of 4.5 ng/dL. Serum PTX3 demonstrated an AUC of 0.70 (95%IC 0.51–0.87) with Se 72%, Sp 67%, PPV 30%, NPV 93%, LR+ 2.2 and LR- 0.42 for a threshold value of 4.5 ng/dL. Conclusions. In patients undergoing revision surgery for painful THA or TKA, synovial PTX3 demonstrated a strong diagnostic ability for PJI. Synovial PTX3 could represent a more useful biomarker for detection of PJI compared with serum PTX3


Bone & Joint Research
Vol. 12, Issue 9 | Pages 559 - 570
14 Sep 2023
Wang Y Li G Ji B Xu B Zhang X Maimaitiyiming A Cao L

Aims. To investigate the optimal thresholds and diagnostic efficacy of commonly used serological and synovial fluid detection indexes for diagnosing periprosthetic joint infection (PJI) in patients who have rheumatoid arthritis (RA). Methods. The data from 348 patients who had RA or osteoarthritis (OA) and had previously undergone a total knee (TKA) and/or a total hip arthroplasty (THA) (including RA-PJI: 60 cases, RA-non-PJI: 80 cases; OA-PJI: 104 cases, OA-non-PJI: 104 cases) were retrospectively analyzed. A receiver operating characteristic curve was used to determine the optimal thresholds of the CRP, ESR, synovial fluid white blood cell count (WBC), and polymorphonuclear neutrophil percentage (PMN%) for diagnosing RA-PJI and OA-PJI. The diagnostic efficacy was evaluated by comparing the area under the curve (AUC) of each index and applying the results of the combined index diagnostic test. Results. For PJI prediction, the results of serological and synovial fluid indexes were different between the RA-PJI and OA-PJI groups. The optimal cutoff value of CRP for diagnosing RA-PJI was 12.5 mg/l, ESR was 39 mm/hour, synovial fluid WBC was 3,654/μl, and PMN% was 65.9%; and those of OA-PJI were 8.2 mg/l, 31 mm/hour, 2,673/μl, and 62.0%, respectively. In the RA-PJI group, the specificity (94.4%), positive predictive value (97.1%), and AUC (0.916) of synovial fluid WBC were higher than those of the other indexes. The optimal cutoff values of synovial fluid WBC and PMN% for diagnosing RA-PJI after THA were significantly higher than those of TKA. The specificity and positive predictive value of the combined index were 100%. Conclusion. Serum inflammatory and synovial fluid indexes can be used for diagnosing RA-PJI, for which synovial fluid WBC is the best detection index. Combining multiple detection indexes can provide a reference basis for the early and accurate diagnosis of RA-PJI. Cite this article: Bone Joint Res 2023;12(9):559–570


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 431 - 438
15 Mar 2023
Vendeuvre T Tabard-Fougère A Armand S Dayer R

Aims. This study aimed to evaluate rasterstereography of the spine as a diagnostic test for adolescent idiopathic soliosis (AIS), and to compare its results with those obtained using a scoliometer. Methods. Adolescents suspected of AIS and scheduled for radiographs were included. Rasterstereographic scoliosis angle (SA), maximal vertebral surface rotation (ROT), and angle of trunk rotation (ATR) with a scoliometer were evaluated. The area under the curve (AUC) from receiver operating characteristic (ROC) plots were used to describe the discriminative ability of the SA, ROT, and ATR for scoliosis, defined as a Cobb angle > 10°. Test characteristics (sensitivity and specificity) were reported for the best threshold identified using the Youden method. AUC of SA, ATR, and ROT were compared using the bootstrap test for two correlated ROC curves method. Results. Of 212 patients studied, 146 (69%) had an AIS. The AUC was 0.74 for scoliosis angle (threshold 12.5°, sensitivity 75%, specificity 65%), 0.65 for maximal vertebral surface rotation (threshold 7.5°, sensitivity 63%, specificity 64%), and 0.82 for angle of trunk rotation (threshold 5.5°, sensitivity 65%, specificity 80%). The AUC of ROT was significantly lower than that of ATR (p < 0.001) and SA (p < 0.001). The AUCs of ATR and SA were not significantly different (p = 0.115). Conclusion. The rasterstereographic scoliosis angle has better diagnostic characteristics than the angle of trunk rotation evaluated with a scoliometer, with similar AUCs and a higher sensitivity. Cite this article: Bone Joint J 2023;105-B(4):431–438


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 86 - 86
1 Jul 2020
Innmann MM Grammatopoulos G Beaulé P Merle C Gotterbarm T
Full Access

Spinopelvic mobility describes the change in lumbar lordosis and pelvic tilt from standing to sitting position. For 1° of posterior pelvic tilt, functional cup anteversion increases by 0.75° after total hip arthroplasty (THA). Thus, spinopelvic mobility is of high clinical relevance regarding the risk of implant impingement and dislocation.

Our study aimed to 1) determine the proportion of OA-patients with stiff, normal or hypermobile spino-pelvic mobility and 2) to identify clinical or static standing radiographic parameters predicting spinopelvic mobility.

This prospective diagnostic cohort study followed 122 consecutive patients with end-stage osteoarthritis awaiting THA. Preoperatively, the Oxford Hip Score, Oswestry Disability Index and Schober's test were assessed in a standardized clinical examination. Lateral view radiographs were taken of the lumbar spine, pelvis and proximal femur using EOS© in standing position and with femurs parallel to the floor in order to achieve a 90°-seated position. Radiographic measurements were performed for the lumbar lordosis angle (LL), sacral slope (SS), pelvic tilt (PT), pelvic incidence (PI) and pelvic-femoral-angle (PFA). The difference in PT between standing and seated allowed for patient classification based on spino-pelvic mobility into stiff (±30°).

From the standing to the sitting position, the pelvis tilted backwards by a mean of 19.6° (SD 11.6) and the hip was flexed by a mean of 57° (SD 17). Change in pelvic tilt correlated inversely with change in hip flexion.

Spinopelvic mobility is highly variable in patients awaiting THA and we could not identify any clinical or static standing radiographic parameter predicting the change in pelvic tilt from standing to sitting position. In order to identify patients with stiff or hypermobile spinopelvic mobility, we recommend performing lateral view radiographs of the lumbar spine, pelvis and proximal femur in all patients awaiting THA. Thereafter, implants and combined cup inclination/anteversion can be individually chosen to minimize the risk of dislocation.

No predictors could be identified. We recommend performing sitting and standing lateral view radiographs of the lumbar spine and pelvis to determine spinopelvic mobility in patients awaiting THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 734 - 736
1 Sep 1993
Otremski I Newman R Kahn P Stadler J Kariv N Skornik Y Goldman G

This new blood test for infection is based on the phenomenon of leukergy in which white cells agglomerate in the peripheral blood of patients with inflammatory diseases. It was used in 26 patients with proven bone or joint infection and was positive in 25. The leukergy test was more accurate than the ESR, white cell count or blood culture. The percentage of cells agglomerated correlated with the clinical severity of the infection and the test detected reactivation of the septic process better than the other haematological tests. It is a rapid and inexpensive method which is useful in the diagnosis and management of bone and joint infections.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 796 - 805
1 Oct 2021
Plumarom Y Wilkinson BG Willey MC An Q Marsh L Karam MD

Aims

The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing.

Methods

A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point.



The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 21 - 28
1 Jan 2023
Ndlovu S Naqshband M Masunda S Ndlovu K Chettiar K Anugraha A

Aims. Clinical management of open fractures is challenging and frequently requires complex reconstruction procedures. The Gustilo-Anderson classification lacks uniform interpretation, has poor interobserver reliability, and fails to account for injuries to musculotendinous units and bone. The Ganga Hospital Open Injury Severity Score (GHOISS) was designed to address these concerns. The major aim of this review was to ascertain the evidence available on accuracy of the GHOISS in predicting successful limb salvage in patients with mangled limbs. Methods. We searched electronic data bases including PubMed, CENTRAL, EMBASE, CINAHL, Scopus, and Web of Science to identify studies that employed the GHOISS risk tool in managing complex limb injuries published from April 2006, when the score was introduced, until April 2021. Primary outcome was the measured sensitivity and specificity of the GHOISS risk tool for predicting amputation at a specified threshold score. Secondary outcomes included length of stay, need for plastic surgery, deep infection rate, time to fracture union, and functional outcome measures. Diagnostic test accuracy meta-analysis was performed using a random effects bivariate binomial model. Results. We identified 1,304 records, of which six prospective cohort studies and two retrospective cohort studies evaluating a total of 788 patients were deemed eligible for inclusion. A diagnostic test meta-analysis conducted on five cohort studies, with 474 participants, showed that GHOISS at a threshold score of 14 has a pooled sensitivity of 93.4% (95% confidence interval (CI) 78.4 to 98.2) and a specificity of 95% (95% CI 88.7 to 97.9) for predicting primary or secondary amputations in people with complex lower limb injuries. Conclusion. GHOISS is highly accurate in predicting success of limb salvage, and can inform management and predict secondary outcomes. However, there is a need for high-quality multicentre trials to confirm these findings and investigate the effectiveness of the score in children, and in predicting secondary amputations. Cite this article: Bone Joint J 2023;105-B(1):21–28


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 158 - 165
1 Feb 2023
Sigmund IK Yeghiazaryan L Luger M Windhager R Sulzbacher I McNally MA

Aims. The aim of this study was to evaluate the optimal deep tissue specimen sample number for histopathological analysis in the diagnosis of periprosthetic joint infection (PJI). Methods. In this retrospective diagnostic study, patients undergoing revision surgery after total hip or knee arthroplasty (n = 119) between January 2015 and July 2018 were included. Multiple specimens of the periprosthetic membrane and pseudocapsule were obtained for histopathological analysis at revision arthroplasty. Based on the Infectious Diseases Society of America (IDSA) 2013 criteria, the International Consensus Meeting (ICM) 2018 criteria, and the European Bone and Joint Infection Society (EBJIS) 2021 criteria, PJI was defined. Using a mixed effects logistic regression model, the sensitivity and specificity of the histological diagnosis were calculated. The optimal number of periprosthetic tissue specimens for histopathological analysis was determined by applying the Youden index. Results. Based on the EBJIS criteria (excluding histology), 46 (39%) patients were classified as infected. Four to six specimens showed the highest Youden index (four specimens: 0.631; five: 0.634; six: 0.632). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of five tissue specimens were 76.5% (95% confidence interval (CI) 67.6 to 81.4), 86.8% (95% CI 81.3 to 93.5), 66.0% (95% CI 53.2 to 78.7), and 84.3% (95% CI 79.4 to 89.3), respectively. The area under the curve (AUC) was calculated with 0.81 (as a function of the number of tissue specimens). Applying the ICM and IDSA criteria (excluding histology), 40 (34%) and 32 (27%) patients were categorized as septic. Three to five specimens had the highest Youden index (ICM 3: 0.648; 4: 0.651; 5: 0.649) (IDSA 3: 0.627; 4: 0.629; 5: 0.625). Conclusion. Three to six tissue specimens of the periprosthetic membrane and pseudocapsule should be collected at revision arthroplasty and analyzed by a pathologist experienced and skilled in interpreting periprosthetic tissue. Cite this article: Bone Joint J 2023;105-B(2):158–165


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 18 - 25
1 Jan 2021
McNally M Sousa R Wouthuyzen-Bakker M Chen AF Soriano A Vogely HC Clauss M Higuera CA Trebše R

Aims. The diagnosis of periprosthetic joint infection (PJI) can be difficult. All current diagnostic tests have problems with accuracy and interpretation of results. Many new tests have been proposed, but there is no consensus on the place of many of these in the diagnostic pathway. Previous attempts to develop a definition of PJI have not been universally accepted and there remains no reference standard definition. Methods. This paper reports the outcome of a project developed by the European Bone and Joint Infection Society (EBJIS), and supported by the Musculoskeletal Infection Society (MSIS) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Implant-Associated Infections (ESGIAI). It comprised a comprehensive review of the literature, open discussion with Society members and conference delegates, and an expert panel assessment of the results to produce the final guidance. Results. This process evolved a three-level approach to the diagnostic continuum, resulting in a definition set and guidance, which has been fully endorsed by EBJIS, MSIS, and ESGIAI. Conclusion. The definition presents a novel three-level approach to diagnosis, based on the most robust evidence, which will be useful to clinicians in daily practice. Cite this article: Bone Joint J 2021;103-B(1):18–25


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 36 - 36
7 Nov 2023
Waters R Held M Dunn R Laubscher M Adikary N Coussens A
Full Access

Specific and rapid detection methods for spinal tuberculosis, with sufficient sensitivity in HIV-1 co-infected individuals, are needed, to ensure early initiation of appropriate treatment to prevent physical disability and neurological fallout. In addition, understanding the systemic and local pathophysiology of spinal tuberculosis, and its interaction with HIV-1 infection, is crucial to guide future therapeutic interventions. We prospectively enrolled adult patients presenting with signs and symptoms of suspected spinal tuberculosis, at Groote Schuur Hospital, between November 2020 and December 2021. TB diagnostic testing was performed on open and CT-guided spinal biopsies using Xpert MTB/RIF Ultra compared to gold standards TB culture and histology. A highly sensitive droplet digital PCR assay for detecting and quantifying Mycobacterium tuberculosis complex (MTBC) and HIV-1 DNA was tested. Plasma inflammatory proteins were measured to assess systemic inflammation. Xpert Ultra had a high sensitivity of 94.7% and specificity of 100% for STB against TB culture and histology in both open and CT-guided biopsy samples. The ddPCR assay confirmed TB detection in 94% of patients with positive Xpert Ultra results. Four patients with negative TB diagnostic results had MTBC DNA detected by ddPCR. HIV-1 DNA was detected in the spinal tissues from all HIV-1-infected patients. MTBC DNA levels were significantly higher in HIV-1-co-infected spinal tissue samples (p< 0.01). We identified four biomarkers significantly associated with higher bacterial burden at the disease site (p< 0.01). Xpert Ultra and MTBC ddPCR improve the detection of STB. DdPCR can be utilized as an additional, highly sensitive tool for detecting and quantifying Mtb, in pathological samples that may be paucibacillary. These findings provide novel diagnostic and pathophysiologic insight into STB, in the context of HIV-1 infection, and provide rationale to include these tests in hospital and research settings for patients from communities burdened by TB and HIV-1


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 79 - 79
22 Nov 2024
Luger M Böhler C Staats K Windhager R Sigmund IK
Full Access

Aim. Diagnosing low-grade periprosthetic joint infections (PJI) can be very challenging due to low-virulent microorganisms capable of forming biofilm. Clinical signs can be subtle and may be similar to those of aseptic failure. To minimize morbidity and mortality and to preserve quality of life, accurate diagnosis is essential. The aim of this study was to assess the performance of various diagnostic tests in diagnosing low-grade PJI. Methods. Patients undergoing revision surgery after total hip and knee arthroplasty were included in this retrospective cohort study. A standardized diagnostic workup was performed using the components of the 2021 European Bone and Joint Infection Society (EBJIS) definition of PJI. For statistical analyses, the respective test was excluded from the infection definition to eliminate incorporation bias. Receiver-operating-characteristic curves were used to calculate the diagnostic performance of each test, and their area-under-the-curves (AUC) were compared using the z-test. Results. 422 patients undergoing revision surgery after total hip and knee arthroplasty were included in this study. 208 cases (49.3%) were diagnosed as septic. Of those, 60 infections (28.8%) were defined as low-grade PJI (symptoms >4 weeks and caused by low-virulent microorganisms (e. g. coagulase-negative staphylococci, Cutibacterium spp., enterococci and Actinomyces)). Performances of the different test methods are listed in Table 1. Synovial fluid (SF) - WBC (white blood cell count) >3000G/L (0.902), SF - %PMN (percentage of polymorphonuclear neutrophils) > 65% (0.959), histology (0.948), and frozen section (0.925) showed the best AUCs. Conclusion. The confirmatory criteria according to the EBJIS definition showed almost ideal performances in ruling-in PJI (>99% specificity). Histology and synovial fluid cell count (SF-WBC and SF-%PMN) showed excellent accuracies for diagnosing low-grade PJI. However, a reduced immune reaction in these cases may necessitate lower cut-off values. Intraoperative frozen section may be valuable in cases with inconclusive preoperative diagnosis. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 43 - 43
22 Nov 2024
Bekkers W Zwart V Swietoslawki A Oost IK Nijs A Emmen J Van Geenen R
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the main reasons for revision surgery after primary unicompartmental knee arthroplasty (UKA), total knee arthroplasty (TKA) or total hip arthroplasty (THA). Currently the MSIS and EBJIS criteria sets are considered to be the gold standards in determining PJI. These criteria sets are complex and contain tests that are time-consuming and many are rather costly. Therefore, further research is indicated to find a simpler but equally reliable diagnostic test. In this study we evaluated the additional value of calprotectine measurement in synovial fluid in patients undergoing hip and knee (revision) arthroplasty following routine work-up. Method. In a retrospective cohort study, we analyzed 182 synovial fluid samples from 143 patients with suspected PJI after UKA, TKA, THA or revision arthroplasty. Twenty-six of those cases were classified as PJI according to the MSIS and EBJIS criteria. Subsequently, synovial calprotectin was determined, using a lateral flow assay and two cut-off thresholds of ≥14 mg/L and ≥50 mg/L. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of synovial calprotectin was determined. Results. When applying the MSIS and EBJIS criteria and a calprotectin level ≥14 mg/L, synovial calprotectin revealed an area under the curve of 0.96 (95% CI 0.90-1.00), with 92.3% sensitivity and 100% specificity. The PPV and NPV were 100% and 92.9% respectively. When applying the MSIS and EBJIS criteria and a calprotectin level ≥ 50 mg/L, synovial calprotectin revealed an area under the curve of 0.94 (95% CI 0.87-1.00), with 88.5% sensitivity and 100% specificity. The PPV and NPV were 100% and 89.7% respectively. Conclusions. The value of calprotectin in synovial fluid gives valuable information with a single test result, resulting in high predictive value in the diagnosis of PJI after hip or knee arthroplasty and should seriously be considered as part of PJI diagnostics in an outpatient clinical setting. The high specificity can help rule in patients that are suspected of PJI. Therefor this test can be helpful in a preop diagnostic work-up to avoid unnecessary revisions in patients with well-placed and well-fixed arthroplasties with a suspected PJI. These conclusions are independent of which criteria set was used as a gold standard


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 458 - 464
1 Apr 2017
Abrahams JM Kim YS Callary SA De Ieso C Costi K Howie DW Solomon LB

Aims. This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria. Patients and Methods. Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed. Results. Using EBRA, both proximal translation and sagittal rotation were excellent diagnostic tests for detecting aseptic loosening. The area under the receiver operating characteristic (ROC) curves was 0.94 and 0.93, respectively. The thresholds of 2.5 mm proximal translation or 2° sagittal rotation (EBRA) in combination with radiolucency criteria had a sensitivity of 93% and specificity of 88% to detect aseptic loosening. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of radiolucency criteria were 41%, 100%, 100% and 68% respectively. Manual measurements of both proximal translation and sagittal rotation were very good diagnostic tests. The area under the ROC curve was 0.86 and 0.92 respectively. However, manual measurements had a decreased specificity compared with EBRA. Radiolucency criteria had a poor sensitivity and NPV of 41% and 68% respectively. Conclusion. This study shows that EBRA and manual migration measurements can be used as accurate diagnostic tools to detect aseptic loosening of cementless acetabular components used at revision THA. Radiolucency criteria should not be used in isolation to exclude loosening of cementless acetabular components used at revision THA given their poor sensitivity and NPV. Cite this article: Bone Joint J 2017;99-B:458–64


Bone & Joint Open
Vol. 1, Issue 12 | Pages 737 - 742
1 Dec 2020
Mihalič R Zdovc J Brumat P Trebše R

Aims. Synovial fluid white blood cell (WBC) count and percentage of polymorphonuclear cells (%PMN) are elevated at periprosthetic joint infection (PJI). Leucocytes produce different interleukins (IL), including IL-6, so we hypothesized that synovial fluid IL-6 could be a more accurate predictor of PJI than synovial fluid WBC count and %PMN. The main aim of our study was to compare the predictive performance of all three diagnostic tests in the detection of PJI. Methods. Patients undergoing total hip or knee revision surgery were included. In the perioperative assessment phase, synovial fluid WBC count, %PMN, and IL-6 concentration were measured. Patients were labeled as positive or negative according to the predefined cut-off values for IL-6 and WBC count with %PMN. Intraoperative samples for microbiological and histopathological analysis were obtained. PJI was defined as the presence of sinus tract, inflammation in histopathological samples, and growth of the same microorganism in a minimum of two or more samples out of at least four taken. Results. In total, 49 joints in 48 patients (mean age 68 years (SD 10; 26 females (54%), 25 knees (51%)) were included. Of these 11 joints (22%) were infected. The synovial fluid WBC count and %PMN predicted PJI with sensitivity, specificity, accuracy, PPV, and NPV of 82%, 97%, 94%, 90%, and 95%, respectively. Synovial fluid IL-6 predicted PJI with sensitivity, specificity, accuracy, PPV, and NPV of 73%, 95%, 90%, 80%, and 92%, respectively. A comparison of predictive performance indicated a strong agreement between tests. Conclusions. Synovial fluid IL-6 is not superior to synovial fluid WBC count and %PMN in detecting PJI. Level of Evidence: Therapeutic Level II. Cite this article: Bone Jt Open 2020;1-12:737–742


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 34 - 34
1 Dec 2022
Lapner P Pollock J Hodgdon T Sheikh A Shamloo A Fernandez AA McIlquham K Desjardins M Drosdowech D Nam D Rouleau D
Full Access

The diagnosis of infection following shoulder arthroplasty is notoriously difficult. The prevalence of prosthetic shoulder infection after arthroplasty ranges from 3.9 – 15.4% and the most common infective organism is Cutibacterium acnes. Current preoperative diagnostic tests fail to provide a reliable means of diagnosis including WBC, ESR, CRP and joint aspiration. Fluoroscopic-guided percutaneous synovial biopsy (PSB) has previously been reported in the context of a pilot study and demonstrated promising results. The purpose of this study was to determine the diagnostic accuracy of percutaneous synovial biopsy compared with open culture results (gold standard). This was a multicenter prospective cohort study involving four sites and 98 patients who underwent revision shoulder arthroplasty. The cohort was 60% female with a mean age was 65 years (range 36-83 years). Enrollment occurred between June 2014 and November 2021. Pre-operative fluoroscopy-guided synovial biopsies were carried out by musculoskeletal radiologists prior to revision surgery. A minimum of five synovial capsular tissue biopsies were obtained from five separate regions in the shoulder. Revision shoulder arthroplasty was performed by fellowship-trained shoulder surgeons. Intraoperative tissue samples were taken from five regions of the joint capsule during revision surgery. Of 98 patients who underwent revision surgery, 71 patients underwent both the synovial biopsy and open biopsy at time of revision surgery. Nineteen percent had positive infection based on PSB, and 22% had confirmed culture positive infections based on intra-operative tissue sampling. The diagnostic accuracy of PSB compared with open biopsy results were as follows: sensitivity 0.37 (95%CI 0.13-0.61), specificity 0.81 (95%CI 0.7-0.91), positive predictive value 0.37 (95%CI 0.13 – 0.61), negative predictive value 0.81 (95%CI 0.70-0.91), positive likelihood ratio 1.98 and negative likelihood ratio 0.77. A patient with a positive pre-operative PSB undergoing revision surgery had an 37% probability of having true positive infection. A patient with a negative pre-operative PSB has an 81% chance of being infection-free. PSB appears to be of value mainly in ruling out the presence of peri-prosthetic infection. However, poor likelihood ratios suggest that other ancillary tests are required in the pre-operative workup of the potentially infected patient


Bone & Joint Research
Vol. 10, Issue 8 | Pages 536 - 547
2 Aug 2021
Sigmund IK McNally MA Luger M Böhler C Windhager R Sulzbacher I

Aims. Histology is an established tool in diagnosing periprosthetic joint infections (PJIs). Different thresholds, using various infection definitions and histopathological criteria, have been described. This study determined the performance of different thresholds of polymorphonuclear neutrophils (≥ 5 PMN/HPF, ≥ 10 PMN/HPF, ≥ 23 PMN/10 HPF) , when using the European Bone and Joint Infection Society (EBJIS), Infectious Diseases Society of America (IDSA), and the International Consensus Meeting (ICM) 2018 criteria for PJI. Methods. A total of 119 patients undergoing revision total hip (rTHA) or knee arthroplasty (rTKA) were included. Permanent histology sections of periprosthetic tissue were evaluated under high power (400× magnification) and neutrophils were counted per HPF. The mean neutrophil count in ten HPFs was calculated (PMN/HPF). Based on receiver operating characteristic (ROC) curve analysis and the z-test, thresholds were compared. Results. Using the EBJIS criteria, a cut-off of ≥ five PMN/HPF showed a sensitivity of 93% (95% confidence interval (CI) 81 to 98) and specificity of 84% (95% CI 74 to 91). The optimal threshold when applying the IDSA and ICM criteria was ≥ ten PMN/HPF with sensitivities of 94% (95% CI 79 to 99) and 90% (95% CI 76 to 97), and specificities of 86% (95% CI 77 to 92) and 92% (95% CI 84 to 97), respectively. In rTKA, a better performance of histopathological analysis was observed in comparison with rTHA when using the IDSA criteria (p < 0.001). Conclusion. With high accuracy, histopathological analysis can be supported as a confirmatory criterion in diagnosing periprosthetic joint infections. A threshold of ≥ five PMN/HPF can be recommended to distinguish between septic and aseptic loosening, with an increased possibility of detecting more infections caused by low-virulence organisms. However, neutrophil counts between one and five should be considered suggestive of infection and interpreted carefully in conjunction with other diagnostic test methods. Cite this article: Bone Joint Res 2021;10(8):536–547


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 66 - 72
1 Jan 2017
Sigmund IK Holinka J Gamper J Staats K Böhler C Kubista B Windhager R

Aims. The diagnosis of periprosthetic joint infection (PJI) remains demanding due to limitations of all the available diagnostic tests. The synovial fluid marker, α-defensin, is a promising adjunct for the assessment of potential PJI. The purpose of this study was to investigate the qualitative assessment of α-defensin, using Synovasure to detect or exclude periprosthetic infection in total joint arthroplasty. Patients and Methods. We studied 50 patients (28 women, 22 men, mean age 65 years; 20 to 89) with a clinical indication for revision arthroplasty who met the inclusion criteria of this prospective diagnostic study. The presence of α-defensin was determined using the qualitative Synovasure test and compared with standard diagnostic methods for PJI. Based on modified Musculoskeletal Infection Society (MSIS) criteria, 13 cases were categorised as septic and 36 as aseptic revisions. One test was inconclusive. Results. The Synovasure test achieved a sensitivity of 69% and a specificity of 94%. The positive and negative likelihood ratios were 12.46 and 0.33, respectively. A good diagnostic accuracy for PJI, with an area under the curve of 0.82, was demonstrated. Adjusted p-values using the method of Hochberg showed that Synovasure is as good at diagnosing PJI as histology (p = 0.0042) and bacteriology with one positive culture (p = 0.0327). Conclusion. With its ease of use and rapid results after approximately ten minutes, Synovasure may be a useful adjunct in the diagnosis of PJI. Cite this article: Bone Joint J 2017;99-B:66–72


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 904 - 911
1 Jul 2020
Sigmund IK Dudareva M Watts D Morgenstern M Athanasou NA McNally MA

Aims. The aim of this study was to evaluate the diagnostic value of preoperative serum CRP, white blood cell count (WBC), percentage of neutrophils (%N), and neutrophil to lymphocyte ratio (NLR) when using the fracture-related infection (FRI) consensus definition. Methods. A cohort of 106 patients having surgery for suspected septic nonunion after failed fracture fixation were studied. Blood samples were collected preoperatively, and the concentration of serum CRP, WBC, and differential cell count were analyzed. The areas under the curve (AUCs) of diagnostic tests were compared using the z-test. Regression trees were constructed and internally cross-validated to derive a simple diagnostic decision tree. Results. Using the FRI consensus definition, 46 patients (43%) were identified as infected. Sensitivity, specificity, and AUC of CRP were 67% (95% confidence interval (CI) 52% to 80%), 61% (95% CI 47% to 74%), and 0.64 (95% CI 0.54 to 0.74); of WBC count were 17% (95% CI 9% to 31%), 95% (95% CI 86% to 99%), and 0.57 (95% CI 0.50 to 0.62); of %N 13% (95% CI 6% to 26%), 87% (95% CI 76% to 93%), and 0.50 (95% CI 0.43 to 0.56); and of NLR 28% (95% CI 17% to 43%), 80% (95% CI 68% to 88%), and 0.54 (95% CI 0.46 to 0.63), respectively. A better performance of serum CRP was shown in comparison to the leucocyte count (p = 0.006), %N (p < 0.001), and NLR (p = 0.001). A statistically lower serum CRP level was shown in patients with an infection caused by a low virulence microorganism in comparison to high virulence bacteria (p = 0.008). We found that a simple decision tree approach using only low serum neutrophils (< 3.615 × 10. 9. /l) and low CRP (< 2.45 mg/l) may allow better identification of aseptic cases. Conclusion. The evaluated serum inflammatory markers showed limited diagnostic value in the preoperative diagnosis of FRI when using the uniform FRI Consensus Definition. Therefore, they should remain as suggestive criteria in diagnosing FRI. Although CRP showed a higher performance in comparison to the other serum markers, it is insufficiently accurate to diagnose a septic nonunion, especially when caused by low virulence microorganisms. Cite this article: Bone Joint J 2020;102-B(7):904–911