Advertisement for orthosearch.org.uk
Results 1 - 20 of 134
Results per page:
Bone & Joint Open
Vol. 3, Issue 10 | Pages 786 - 794
12 Oct 2022
Harrison CJ Plummer OR Dawson J Jenkinson C Hunt A Rodrigues JN

Aims. The aim of this study was to develop and evaluate machine-learning-based computerized adaptive tests (CATs) for the Oxford Hip Score (OHS), Oxford Knee Score (OKS), Oxford Shoulder Score (OSS), and the Oxford Elbow Score (OES) and its subscales. Methods. We developed CAT algorithms for the OHS, OKS, OSS, overall OES, and each of the OES subscales, using responses to the full-length questionnaires and a machine-learning technique called regression tree learning. The algorithms were evaluated through a series of simulation studies, in which they aimed to predict respondents’ full-length questionnaire scores from only a selection of their item responses. In each case, the total number of items used by the CAT algorithm was recorded and CAT scores were compared to full-length questionnaire scores by mean, SD, score distribution plots, Pearson’s correlation coefficient, intraclass correlation (ICC), and the Bland-Altman method. Differences between CAT scores and full-length questionnaire scores were contextualized through comparison to the instruments’ minimal clinically important difference (MCID). Results. The CAT algorithms accurately estimated 12-item questionnaire scores from between four and nine items. Scores followed a very similar distribution between CAT and full-length assessments, with the mean score difference ranging from 0.03 to 0.26 out of 48 points. Pearson’s correlation coefficient and ICC were 0.98 for each 12-item scale and 0.95 or higher for the OES subscales. In over 95% of cases, a patient’s CAT score was within five points of the full-length questionnaire score for each 12-item questionnaire. Conclusion. Oxford Hip Score, Oxford Knee Score, Oxford Shoulder Score, and Oxford Elbow Score (including separate subscale scores) CATs all markedly reduce the burden of items to be completed without sacrificing score accuracy. Cite this article: Bone Jt Open 2022;3(10):786–794


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 59 - 59
1 Dec 2022
Hiemstra LA Bentrim A Kerslake S Lafave M
Full Access

The Banff Patellofemoral Instability Instrument 2.0 (BPII 2.0) is a patient-reported disease-specific quality of life (QOL) outcome measure used to assess patients with recurrent lateral patellofemoral instability (LPI) both pre- and post-operatively. The purpose of this study was to compare the BPII 2.0 to four other relevant patient reported outcome measures (PROMs): the Tampa Scale-11 for kinesiophobia (TSK-11), the pain catastrophizing scale (PCS), a general QOL (EQ-5D-5L), and a return to sport index (ACL-RSI). This concurrent validation sought to compare and correlate the BPII 2.0 with these other measures of physical, psychological, and emotional health. The psychological and emotional status of patients can impact recovery and rehabilitation, and therefore a disease-specific PROM may be unable to consistently identify patients who would benefit from interventions encompassing a holistic and person-focused approach in addition to disease-specific treatment. One hundred and ten patients with recurrent lateral patellofemoral instability (LPI) were assessed at a tertiary orthopaedic practice between January and October 2021. Patients were consented into the study and asked to complete five questionnaires: the BPII 2.0, TSK-11, PCS, EQ-5D-5L, and the ACL-RSI at their initial orthopaedic consultation. Descriptive demographic statistics were collected for all patients. A Pearson's r correlation coefficient was employed to examine the relationships between the five PROMs. These analyses were computed using SPSS 28.0 © (IBM Corporation, 2021). One hundred and ten patients with a mean age of 25.7 (SD = 9.8) completed the five PROMs. There were 29 males (26.3%) and 81 females (73.6%) involving 50% symptomatic left knees and 50% symptomatic right knees. The mean age of the first dislocation was 15.4 years (SD = 7.3; 1-6) and the mean BMI was 26.5 (SD = 7.3; range = 12.5-52.6) The results of the Pearson's r correlation coefficient demonstrated that the BPII 2.0 was statistically significantly related to all of the assessed PROM's (p. There was significant correlation evident between the BPII 2.0 and the four other PROMs assessed in this study. The BPII 2.0 does not explicitly measure kinesiophobia or pain catastrophizing, however, the significant statistical relationship of the TSK-11 and PCS to the BPII 2.0 suggests that this information is being captured and reflected. The preliminary results of this concurrent validation suggest that the pre-operative data may offer predictive validity. Future research will explore the ability of the BPII 2.0 to predict patient quality of life following surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 38 - 38
1 Feb 2020
Tamaoka T Muratsu H Tachibana S Suda Y Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction. Patients-reported outcome measures (PROMs) have been reported as the important methods to evaluate clinical outcomes in total knee arthroplasty (TKA). The patient satisfaction score in Knee Society Score (KSS-2011) has been used in the recent literatures. Patient satisfaction was subjective parameter, and would be affected by multiple factors including psychological factors and physical conditions at not only affected joint but also elsewhere in the body. The question was raised regarding the consistency of patient satisfaction score in KSS-2011 to other PROMs. The purpose of this study was to investigate the correlation of patient satisfaction in KSS-2011 to other categories in KSS-2011 and to other PROMs including Forgotten Joint Score (FJS-12), EuroQol-5 Dimensions (EQ-5D) and 25-questions in Geriatric Locomotive Function Scale (GLFS-25). Material & Method. 83 patients over 65 years old with osteoarthritic knees were involved in this study. All patients underwent CR-TKAs (Persona CR. R. ). The means and ranges of demographics were as follows: age; 74.5 years old (65–89), Hip-Knee-Ankle (HKA) angle; 12.4 (−6.2–22.5) in varus. We asked patients to fulfill the questionnaire including KSS-2011, FJS-12, EQ-5D and GLFS-25 at 1-year postoperative follow-up visit. KSS-2011 consisted of 4 categories of questions; patient satisfaction (PS), symptoms, patient expectations (PE), functional activities (FA). We evaluated the correlation of PS to other PROMs using simple linear regression analyses (p<0.001). Results. The means and standard deviations of 1-year postoperative scores were as follows: PS; 28.5 ± 7.0, symptoms; 19.1 ± 4.3, PE; 11.2 ± 2.9, FA; 71.5 ± 16.6, FJS-12; 51.5 ± 18.6, EQ5D; 0.69 ± 0.10, GLFS-25; 25.7 ± 16.9. PSs were moderately positively correlated to other categories in KSS-2011(correlation coefficient (r): symptoms; 0.69, PE; 0.73, FA; 0.69). PSs were positively correlated to both FJS-12 and EQ5D (r: FJS-12; 0.72, EQ-5D; 0.67) and negatively correlated to GLFS-25(r; −0.74). Discussions. Patient satisfaction score positively correlated to the symptoms, patient expectation and functional activities in KSS-2011 with moderately high correlation coefficient. This meant the better pain relief and functional outcome improved patient satisfaction. Although there had be reported preoperative higher expectation would lead to poor patient satisfaction postoperatively, we interestingly found positive correlation between patient satisfaction and expectation at 1 year after TKA. Patient with the higher satisfaction tended to expect more in the future, on the other hand, unsatisfied patient with residual pain and/or poor function would resign themselves to the present status and reduced their expectation in our patient population. We have found patient satisfaction score in KSS-2011 significantly correlated to FJS-12 and GLFS-25 with strong correlation coefficient. This meant patient satisfaction could be considered consist to other PROMS in relatively younger patient with better functional status in this study. Conclusion. The patient satisfaction score in KSS-2011 was found to be consistent with moderately high correlations coefficient to other categories in KSS-2011 and other PROMs including FJS-12, EQ-5D, GLFS-25 at 1 year after (CR)-TKA. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 92 - 92
1 Dec 2022
Gazendam A Schneider P Busse J Bhandari M Ghert M
Full Access

Functional outcomes are commonly reported in studies of musculoskeletal oncology patients undergoing limb salvage surgery; however, interpretation requires knowledge of the smallest amount of improvement that is important to patients – the minimally important difference (MID). We established the MIDs for the Musculoskeletal Tumor Society Rating Scale (MSTS) and Toronto Extremity Salvage Score (TESS) in patients with bone tumors undergoing lower limb salvage surgery. This study was a secondary analysis of the recently completed PARITY (Prophylactic Antibiotic Regimens in Tumor Surgery) study. This data was used to calculate: (1) the anchor-based MIDs using an overall function scale and a receiver operating curve analysis, and (2) the distribution-based MIDs based on one-half of the standard deviation of the change scores from baseline to 12-month follow-up, for both the MSTS and TESS. There were 591 patients available for analysis. The Pearson correlation coefficients for the association between changes in MSTS and TESS scores and changes in the external anchor scores were 0.71 and 0.57, indicating “high” and “moderate” correlation. Anchor-based MIDs were 12 points and 11 points for the MSTS and TESS, respectively. Distribution-based calculations yielded MIDs of 16-17 points for the MSTS and 14 points for the TESS. The current study proposes MID scores for both the MSTS and TESS outcome measures based on 591 patients with bone tumors undergoing lower extremity endoprosthetic reconstruction. These thresholds will optimize interpretation of the magnitude of treatment effects, which will enable shared decision-making with patients in trading off desirable and undesirable outcomes of alternative management strategies. We recommend anchor-based MIDs as they are grounded in changes in functional status that are meaningful to patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 1 - 1
3 Mar 2023
Kinghorn AF Whatling G Bowd J Wilson C Holt C
Full Access

This study aimed to examine the effect of high tibial osteotomy (HTO) on the ankle and subtalar joints via analysis of static radiographic alignment. We hypothesised that surgical alteration of the alignment of the proximal tibia would result in compensatory distal changes. 35 patients recruited as part of the wider Biomechanics and Bioengineering Centre Versus Arthritis HTO study between 2011 and 2018 had pre- and postoperative full-length weightbearing radiographs taken of their lower limbs. In addition to standard alignment measures of the limb and knee (mechanical tibiofemoral angle, Mikulicz point, medial proximal tibial angle), additional measures were taken of the ankle/subtalar joints (lateral distal tibial angle, ground-talus angle, joint line convergence angle of the ankle) as well as a novel measure of stance width. Results were compared using a paired T-test and Pearson's correlation coefficient. Following HTO, there was a significant (5.4°) change in subtalar alignment. Ground-talus angle appeared related both to the level of malalignment preoperatively and the magnitude of the alignment change caused by the HTO surgery; suggesting subtalar positioning as a key adaptive mechanism. In addition to compensatory changes within the subtalar joints, the patients on average had a 31% wider stance following HTO. These two mechanisms do not appear to be correlated but the morphology of the tibial plafond may influence which compensatory mechanisms are employed by different subgroups of HTO patients. These findings are of vital importance in clinical practice both to anticipate potential changes to the ankle and subtalar joints following HTO but it could also open up wider indications for HTO in the treatment of ankle malalignment and osteoarthritis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 28 - 28
1 Jun 2023
Musielak B Green N Giles S Madan S Fernandes J
Full Access

Introduction. Intramedullary lengthening devices have been in use in older children with closed /open growth plates with good success. This study aims to present the early experience of the FITBONE nail since withdrawal of the PRECICE nail. Materials & Methods. Retrospective analysis of both antegrade and retrograde techniques were utilized. Only patients where union was achieved and full weight bearing commenced were included. The complication rate, length gained, distraction index, weight bearing index (WBI) as well as mechanical axes were analysed. Results. 14 (7 males, 7 females) of a total of 16 (7 males, 7 females) patients with a mean age of 16.9 years with varied diagnosis of LLD were analysed. The mean length gained was 38 mm with an average distraction index of 0,74 mm/day. WBI in these patients on average was 59,6 days/cm lengthened. 6 complications were observed, including two nonunions (successfully treated) and a knee subluxation. Mechanical axis deviation improved from 13,3 mm to 6 mm on average. Overall there has been a nonsignificant tendency for WBI to decrease (Spearman's rank correlation coefficient −0.47, p=0.08) with increasing number of cases done, while no correlation between length gained and WBI (−0.01, p=0.96, respectively) was observed. Some nuances will be discussed. Conclusions. Limb lengthening with the FITBONE nail is relatively safe and efficient, however no significant change was seen in the outcome with previous motorized nails


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 114 - 114
23 Feb 2023
Chai Y Boudali A Farey J Walter W
Full Access

Human error is usually evaluated using statistical descriptions during radiographic annotation. The technological advances popularized the “non-human” landmarking techniques, such as deep learning, in which the error is presented in a confidence format that is not comparable to that of the human method. The region-based landmark definition makes an arbitrary “ground truth” point impossible. The differences in patients’ anatomies, radiograph qualities, and scales make the horizontal comparison difficult. There is a demand to quantify the manual landmarking error in a probability format. Taking the measurement of pelvic tilt (PT) as an example, this study recruited 115 sagittal pelvic radiographs for the measurement of two PTs. We proposed a method to unify the scale of images that allows horizontal comparisons of landmarks and calculated the maximum possible error using a density vector. Traditional descriptive statistics were also applied. All measurements showed excellent reliabilities (intraclass correlation coefficients > 0.9). Eighty-four measurements (6.09%) were qualified as wrong landmarks that failed to label the correct locations. Directional bias (systematic error) was identified due to cognitive differences between observers. By removing wrong labels and rotated pelves, the analysis quantified the error density as a “good doctor” performance and found 6.77°-11.76° maximum PT disagreement with 95% data points. The landmarks with excellent reliability still have a chance (at least 6.09% in our case) of making wrong landmark decisions. Identifying skeletal contours is at least 24.64% more accurate than estimating landmark locations. The landmark at a clear skeletal contour is more likely to generate systematic errors. Due to landmark ambiguity, a very careful surgeon measuring PT could make a maximum 11.76° random difference in 95% of cases, serving as a “good doctor benchmark” to qualify good landmarking techniques


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 116 - 116
23 Feb 2023
Chai Y Khadra S Boudali A Darwish I Walter W
Full Access

Accurate measurement of pelvic tilt (PT) is critical in diagnosing hip and spine pathologies. Yet a sagittal pelvic radiograph with good quality is not always available. Studies explored the correlation between PT and sacro-femoral-pubic (SFP) angle from anteroposterior (AP) radiographs yet demonstrated conflicting conclusions about its feasibilities. This study aims to perform a cohort-controlled meta-analysis to examine the correlation between the SFP angle and PT and proposes an application range of the method. This study searched PubMed, Embase, Cochrane, and Web of Science databases for studies that evaluated the correlation between SFP angle and PT. The Pearson's correlation coefficient r from studies were tabulated and compared. Pooled r for overall and gender/age (teenage or adult) controlled subgroup were reported using Fisher's Z transformation. Heterogeneity and publication bias were evaluated using Egger's regression test for the funnel plot asymmetry. Eleven studies were recruited, with nine reported r (totalling 1,247 patients). The overall pooled r was 0.61 with high inter-study heterogeneity (I2 = 75.95%). Subgroup analysis showed that the adult group had a higher r than the teenage group (0.70 versus 0.56, p < 0.001). Although statistically insignificant (p = 0.062), the female group showed a higher r than the male group (0.72 versus 0.65). The SFP method must be used with caution and should not be used in the male teenage group. The current studies did not demonstrate that the SFP method was superior to other AP landmarks correlating to PT. Identical heterogeneity was observed among studies, indicating that more ethnicity-segregated and gender-specific subgroup studies might be necessary. More data input analysing the errors will be useful


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 100 - 100
23 Feb 2023
Tran T Driessen B Yap V Ng D Khorshid O Wall S Yates P Prosser G Wilkinson M Hazratwala K
Full Access

Clinical success of prostheses in joint arthroplasty is ultimately determined by survivorship and patient satisfaction. The purpose of this study was to compare (non-inferiority) a new morphometric designed stem for total hip arthroplasty (THA) against an established comparator. A prospective randomised multi-centre study of 144 primary cementless THA performed by nine experienced orthopaedic surgeons was completed (70 received a fully coated collarless tapered stem and 74 received a morphometric designed proximally coated tapered stem). PROMs and blood serum markers were assessed preoperatively and at intervals up to 2-years postoperatively. In addition, measures of femoral stem fit, fill and subsidence at 2-years post-operatively were measured from radiographs by three observers, with an intra-class correlation coefficient of 0.918. A mixed effects model was employed to compare the two prosthesis over the study period. A p-value <0.05 was considered statistically significant. Demographics, Dorr types and blood serum markers were similar between groups. Both stems demonstrated a significant improvement in PROMs between the pre- and post-operative measurements, with no difference at any timepoint (p > 0.05). The fully coated tapered collarless femoral stem had a non-significantly higher intra-operative femoral fracture rate (5.8% vs 1.4%, p = 0.24), with all patients treated with cable fixation and partial weight bearing. The mean subsidence at 2-years was 2.5mm +/- 2.3mm for the morphometric stem and 2.4mm +/- 1.8mm for the fully coated tapered collarless femoral stem (p = 0.879). There was one outlier in each group with increased subsidence (fully coated tapered collarless femoral stem 6.9mm, morphometric wedge stem 7.4mm), with both patients reporting thigh pain at 2 years. When compared with an established stem, the newer designed morphometric wedge stem performed well with comparable radiological and PROM outcomes at 2 year follow up. Continued follow-up is required for long term benchmarking


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 36 - 36
10 Feb 2023
Driessen B Yap V Ng D Korshid O Wall S Yates P Prosser G Wilkinson M Hazratwala K Tran. T
Full Access

Clinical success of prostheses in joint arthroplasty is ultimately determined by survivorship and patient satisfaction. The purpose of this study was to compare (non-inferiority) a new morphometric designed stem for total hip arthroplasty (THA) against an established comparator. A prospective randomised multi-centre study of 144 primary cementless THA performed by nine experienced orthopaedic surgeons was completed (70 received a fully coated collarless tapered stem and 70 received a morphometric designed proximally coated tapered stem). PROMs and blood serum markers were assessed preoperatively and at intervals up to 2-years postoperatively. In addition, measures of femoral stem fit, fill and subsidence at 2-years post-operatively were measured from radiographs by three observers, with an intra-class correlation coefficient of 0.918. A mixed effects model was employed to compare the two prostheses over the study period. A p-value <0.05 was considered statistically significant. Demographics and Dorr types were similar between groups. Both stems demonstrated a significant improvement in PROMs between the pre- and post-operative measurements, with no difference at any timepoint (p > 0.05). The fully coated tapered collarless femoral stem had a non-significantly higher intra-operative femoral fracture rate (5.8% vs 1.4%, p = 0.24), with all patients treated with cable fixation and partial weight bearing. The mean subsidence at 2-years was 2.5mm +/- 2.3mm for the morphometric stem and 2.4mm +/- 1.8mm for the fully coated tapered collarless femoral stem (p = 0.879). There was one outlier in each group with increased subsidence (fully coated tapered collarless femoral stem 6.9mm, morphometric wedge stem 7.4mm), with both patients reporting thigh pain at 2 years. When compared with an established stem, the newer designed morphometric wedge stem performed well with comparable radiological and PROM outcomes at 2 year follow up. Continued follow-up is required for long term benchmarking


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 28 - 28
23 Feb 2023
Boudali A Chai Y Farey J Vigdorchik J Walter W
Full Access

The spinopelvic alignment is often assessed via the Pelvic Incidence-Lumbar Lordosis (PI-LL) mismatch. Here we describe and validate a simplified method to evaluating the spinopelvic alignment through the L1-Pelvis angle (L1P). This method is set to reduce the operator error and make the on-film measurement more practicable. 126 standing lateral radiographs of patients presenting for Total Hip Arthroplasty were examined. Three operators were recruited to label 6 landmarks. One operator repeated the landmark selection for intra-operator analysis. We compare PI-LL mismatch obtained via the conventional method, and our simplified method where we estimate this mismatch using PI-LL = L1P - 90°. We also assess the method's reliability and repeatability. We found no significant difference (p > 0.05) between the PI-LL mismatch from the conventional method (mean 0.22° ± 13.6) compared to L1P method (mean 0.0° ± 13.1). The overall average normalised root mean square error (NRMSE) for PI-LL mismatch across all operators is 7.53% (mean -3.3° ± 6.0) and 6.5% (mean -2.9° ± 4.9) for the conventional and L1P method, respectively. In relation to intra-operator repeatability, the correlation coefficients are 0.87 for PI, 0.94 for LL, and 0.96 for L1P. NRMSE between the two measurement sets are PI: 9.96%, LL: 5.97%, and L1P: 4.41%. A similar trend is observed in the absolute error between the two sets of measurements. Results indicate an equivalence in PI-LL measurement between the methods. Reproducibility of the measurements and reliability between operators were improved. Using the L1P angle, the classification of the sagittal spinal deformity found in the literature translates to: normal L1P<100°, mild 100°<L1P<110°, and severe L1P>110°. Surgeons adopting our method should expect a small improvement in reliability and repeatability of their measurements, and a significant improvement of the assessment of the mismatch through the visualisation of the angle L1P


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 37 - 37
10 Feb 2023
McPhee I
Full Access

There are numerous patient satisfaction questionnaires by none specific for an Independent Medical Examination (IME). The aim of this study was to develop and evaluate a questionnaire suitable for an IME. The questionnaire (IMESQ) consisted of five process domains (“Interpersonal manner”, “Communication”, “Technical ability”, “Information exchange”, “Time allocation”) and an outcome domain (“Satisfaction”), each with a five-scale Likert response. An 11-point numerical satisfaction scale (NSS) and a 3-point scale question on the “willing to undergo another examination with the doctor if required” were alternative measures of validation. The questionnaire was tested against numerous independent variables. Statistical analysis included Spearman correlation ((r. S. ) between the items in the questionnaire and the total score with the NSS, and “willing to undergo another examination with the doctor if required” with point-biserial correlation (r. pb. ). Internal consistent reliability was tested using split-half correlation coefficient (r. SB. ) and Cronbach's alpha coefficient (α). The construct was subjected to Factor Analysis. The results from 53 respondents were analysed. There was moderate to strong inter-item correlation (r. s. range 0.57 to 0.83, median 0.67, p < 0.01) and good correlation with the NSS (r. s. = 0.79, p < 0.01) and dichotomous question (r. pb. = 0.45, p < 0.01). Five respondents were “neither satisfied or dissatisfied” (Item 6) and 12 recorded “maybe” to further examination. The split-half correlation was strong (r. SB. = 0.76, p < 0.01). There was good internal consistency reliability (α = 0.92). “Interpersonal manner” (ψ = 4.3) was the only item to have an eigenvalue greater than one, accounting to 72% of the variance across the scale. Eigenvector analysis confirmed the questionnaire was unidimentional. The IMESQ is a brief questionnaire to assess satisfaction with an IME. It is validated and has good internal consistency reliability. The five process domains can identify areas of suboptimal performance: useful for a 360° audit


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 64 - 64
1 Dec 2022
Orloff LE Carsen S Imbeault P Benoit D
Full Access

Anterior cruciate ligament (ACL) injuries have been increasing, especially amongst adolescents. These injuries can increase the risk for early-onset knee osteoarthritis (OA). The consequences of late-stage knee OA include structural joint change, functional limitations and persistent pain. Interleukin-6 (IL-6) is a pro-inflammatory biomarker reflecting knee joint healing, and increasing evidence suggests that IL-6 may play a critical role in the development of pathological pain. The purpose of this study was to determine the relationship between subjective knee joint pain and function, and synovial fluid concentrations of the pro-inflammatory cytokine IL-6, in adolescents undergoing anterior cruciate ligament reconstruction surgery. Seven youth (12-17 yrs.) undergoing anterior cruciate ligament (ACL) reconstruction surgery participated in this study. They completed the Pedi International Knee Documentation Committee (Pedi-IKDC) questionnaire on knee joint pain and function. At the time of their ACL reconstruction surgery, synovial fluid samples were collected through aspiration to dryness with a syringe without saline flushing. IL-6 levels in synovial fluid (sf) were measured using enzyme linked immunosorbent assay. Spearman's rho correlation coefficient was used to determine the correlation between IL-6 levels and scores from the Pedi-IKDC questionnaire. There was a statistically significant correlation between sfIL-6 levels and the Pedi-IKDC Symptoms score (-.929, p=0.003). The correlations between sfIL-6 and Pedi-IKDC activity score (.546, p = .234) and between sfIL-6 and total Pedi-IKDC score (-.536, p = .215) were not statistically significant. This is the first study to evaluate IL-6 as a biomarker of knee joint healing in an adolescent population, reported a very strong correlation (-.929, p=0.003) between IL-6 in knee joint synovial fluid and a subjective questionnaire on knee joint pain. These findings provide preliminary scientific evidence regarding the relationship between knee joint pain, as determined by a validated questionnaire and the inflammatory and healing status of the patient's knee. This study provides a basis and justification for future longitudinal research on biomarkers of knee joint healing in patients throughout their recovery and rehabilitation process. Incorporating physiological and psychosocial variables to current return-to-activity (RTA) criteria has the potential to improve decision making for adolescents following ACL reconstruction to reduce premature RTA thereby reducing the risk of re-injury and risk of early-onset knee OA in adolescents


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 7 - 7
1 Oct 2022
Bottagisio M Viganò M Zagra L Pellegrini A De Vecchi E
Full Access

Aim. The analysis of synovial fluid has proved to be of crucial importance in the diagnostic process of prosthetic joint infections (PJI), suggesting the presence of an infection before the microbiological culture results. In this context, several studies illustrated the efficacy of synovial calprotectin in supporting the diagnosis of PJI [1, 2]. However, several testing methods have been explored to detect synovial calprotectin levels, emphasizing the need to use a standardized, rapid and rapid test. In this study, synovial calprotectin was analyzed by means of a commercial stool test [3] to explore whether the detected levels might predict PJIs and, therefore, being a promising tool for the fast and reliable diagnosis of this complication. Method. The synovial fluid of 55 patients underwent to revision of the prosthetic implant were analyzed. The measurement of calprotectin was carried out by of commercial stool test, following the protocol for liquid samples. Calprotectin levels were then compared to other synovial biomarkers of PJI such as leucocyte esterase and count and percentage of polymorphonuclear cells. Data analysis were performed using R software v4.1.1 (R Core Team) and package “pROC” [4]. Receiver operator characteristics curves were designed using culture test as gold standard to evaluate the area under curve (AUC) of each method (with DeLong method for confidence-interval calculation). Thresholds were calculated to maximize Youden's index; sensitivity and specificity were reported. One-to-one Pearson's correlations coefficient were calculated for each pair of methods. P value <0.05 were considered statistically significant. Results. Of the 55 synovial fluids analyzed, 13 patients were diagnosed with PJI and 42 with an aseptic failure of the implant. The specificity, sensitivity, and AUC of calprotectin resulted 0.90, 0.85, and 0.86 (95%CI: 0.72–0.99), respectively with a set threshold of 226.5 µg/g. The values of calprotectin had a moderate and statistically relevant correlation with the synovial leucocyte counts (r. s. = 0.54, p = 0.0003) and the percentage of polymorphonuclear cells (r. s. = 0.68, p = 0.0000). Conclusions. From this analysis, it can be concluded that synovial calprotectin is a valuable biomarker that correlates with other established indicator of local infection, delivering a rapid and reliable results and supporting the diagnostic process of PJI


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 85 - 85
1 Jul 2020
Willing R Soltanmohammadi P
Full Access

Statistical shape modeling (SSM) and statistical density modeling (SDM) are tools capable of describing the main modes of deviation in the shape and density distribution of the shoulder using a set of uncorrelated variables called principal components (PCs). We hypothesize that the first PC of the SDM, which scales overall density up/down, will be inversely correlated with age and will, on average, be greater for males than females. We also hypothesize that there is a correlation between some PCs of shape and density. SSM and SDM were developed for scapulae and humeri by segmenting surface meshes from computed tomographic images of 75 cadaveric shoulders. Bones were co-registered and defined by the same surface mesh. Volumetric tetrahedral meshes were defined for one of the specimens serving as base meshes for SDM. Base meshes were morphed to each individual bone's surface and superimposed upon the corresponding CT data to determine image intensity in Hounsfield units at each node. Principal component analysis was performed on the exterior shape and internal density distribution of bones. T-tests were performed to find any differences in PC scores between males and females, and Pearson correlation coefficients were calculated for age and PC scores. Finally, correlation coefficients between each of the PCs of the shape and density models were calculated. For the humerus, the first three PCs of the SDM were significantly correlated with age (ρ = 0.40, −0.46, and 0.36, all p ≤ 0.007). For the scapula, the first and ninth PCs showed such correlation (ρ = −0.31, and −0.32, all p ≤ 0.02). Statistically significant differences due to sex were found for the second to sixth SDM PCs of the humerus, with differences in average PC scores of 1, 1, −0.7, −0.8, and −0.6 standard deviations, respectively, for males relative to females. For the scapula, the second, fifth and seventh SDM PCs were significantly different between males and females, with average PC scores differing by 1.1, 0.7, and −0.6 standard deviations. Finally, for both bones, the first PC of SSM showed a weak but significant correlation with the second PC of the SDM (ρ = 0.47, p < 0.001 for the humerus, and ρ = 0.39, p < 0.001 for the scapula). The results of this study suggest that age has a significant influence on the first PC of the SDM, associated with scaling the density in the cortical boundary. Moreover, the negative correlation of age with the second PC of the humerus in SDM which mostly influences the thickness of the cortical boundary implies cortical thinning with age. The second PC of both bones differed significantly between males and females, implying that cortical thickness differs between sexes. Also, there was a significant correlation between the size of the bones and the thickness of the cortical boundary. These findings can help guide the designs of population-based prosthesis components


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 57 - 57
1 Dec 2022
Champagne A McGuire A Shearer K Brien D Martineau PA Bardana DD
Full Access

Reconstruction of the anterior cruciate ligament (ACL) allows to restore stability of the knee, in order to facilitate the return to activity (RTA). Although it is understood that the tendon autograft undergoes a ligamentous transformation postoperatively, knowledge about longitudinal microstructural differences in tissue integrity between types of tendon autografts (ie, hamstring vs. patella) remains limited. Diffusion tensor imaging (DTI) has emerged as an objective biomarker to characterize the ligamentization process of the tendon autograft following surgical reconstruction. One major limitation to its use is the need for a pre-injury baseline MRI to compare recovery of the graft, and inform RTA. Here, we explore the relationship for DTI biomarkers (fractional anisotropy, FA) between knees bilaterally, in healthy participants, with the hypothesis that agreement within a patient's knees may support the use of the contralateral knee as a reference to monitor recovery of the tendon autograft, and inform RTA. Fifteen participants with no previous history of knee injuries were enrolled in this study (age, 26.7 +/− 4.4 years; M/F, 7/8). All images were acquired on a 3T Prisma Siemens scanner using a secured flexible 18-channel coil wrapped around the knee. Both knees were scanned. A 3D anatomical Double Echo Steady State (DESS) sequence was acquired on which regions of interest (ROI) were placed consistent with the footprints of the ACL (femur, posteromedial corner on medial aspect of lateral condyle; tibia, anteromedial to intercondylar eminence). Diffusion images were acquired using fat saturation based on optimized parameters in-house. All diffusion images were pre-processed using the FMRIB FSL toolbox. The footprint ROIs of the ACL were then used to reconstruct the ligament in each patient with fiber-based probabilistic tractography (FBPT), providing a semi-automated approach for segmentation. Average FA was computed for each subject, in both knees, and then correlated against one another using a Pearson correlation to assess the degree of similarity between the ACLs. A total of 30 datasets were collected for this study (1/knee/participant; N=15). The group averaged FA (+/− standard deviation) for the FBPT segmented ACLs were found to equal 0.1683 +/− 0.0235 (dominant leg) and 0.1666 +/− 0.0225 (non-dominant leg). When comparing both knees within subjects, reliable agreement was found for the FBPT-derived ACL with a linear correlation coefficient (rho) equal to 0.87 (P < 0 .001). We sought to assess the degree of concordance in FA between the knees of healthy participants with hopes to provide a method for using the contralateral “healthy” knee in the comparison of autograft-dependent longitudinal changes in microstructural integrity, following ACL reconstruction. Our results suggest that good agreement in anisotropy can be achieved between the non-dominant and dominant knees using DTI and the FBPT segmentation method. Contralateral anisotropy of the ACL, assuming no previous injuries, may be used as a quantitative reference biomarker for monitoring the recovery of the tendon autograft following surgical reconstruction, and gather further insight as to potential differences between chosen autografts. Clinically, this may also serve as an index to supplement decision-making with respect to RTA, and reduce rates of re-injuries


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 17 - 17
3 Mar 2023
Warder H Semple A Johnson DS
Full Access

A hip fracture represents the extreme end of osteoporosis, placing a significant burden on secondary care, society, and the individual patient. The National Hip Fracture Database (NHFD) reports each hospital's attainment of the BPT with other measures, along with reporting outcomes. There is clearly wide variability in provision of orthogerriatrician (OG) services across the dataset. Unfortunately, despite overwhelming evidence that provision of an OG service is of benefit, it is presently challenging to recruit to this important specialty within the UK. Publicly available reports from the NHFD were obtained for each of the 177 participating hospitals for 2017. This was matched with information held within the annual NHFD Facilities Audit for the same period, which include hours of OG support for each hospital. This information was combined with a Freedom of Information request made by email to each hospital for further details concerning OG support. The outcome measures used were Length of Stay (LoS), mortality, and return to usual residence. Comparison was made with provision of OG services by use of Pearson's correlation coefficient. In addition, differences in services were compared between the 25% (44) hospitals delivering outcomes at the extremes for each measure. Attainment of BPT correlated fairly with LoS (−0.48) and to less of a degree with mortality (−0.1) and return home (0.05). Perioperative medical assessment contributed very strongly with BPT attainment (0.75). In turn perioperative medical assessment correlated fairly with LoS (−0.40) and mortality (−0.23) but not return home (0.02). Provision of perioperative medical assessment attainment was correlated fairly with total OG minutes available per new patient (0.22), total OG minutes available per patient per day (0.29) and number of days per week of OG cover (0.34); with no link for number of patients per orthogeriatrician (0.01). Mortality for the best units were associated with 30% more consultant OG time available per patient per day, and 51% more OG time available per patient. Units returning the most patients to their usual residence had little association with OG time, although had 59% fewer patients per OG, the best units had a 19% longer LoS. For all three measures results for the best had on average 0.5 days per week better routine OG access. There is no doubt that good quality care gives better results for this challenging group of patients. However, the interaction of BPT, other care metrics, level of OG support and patient factors with outcomes is complex. We have found OG time available per patient per day appears to influence particularly LoS and mortality. Options to increase OG time per patient include reducing patient numbers (ensuring community osteoporosis/falls prevention in place, including reducing in-patient falls); increasing OG time across the week (employing greater numbers/spreading availability over 7 days per week); and reducing LoS. A reduction in LoS has the largest effect of increasing OG time, and although it is dependent on OG support, it is only fairly correlated with this and many other factors play a part, which could be addressed in units under pressure


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 130 - 130
1 Apr 2019
Tamura K Takao M Hamada H Sakai T Sugano N
Full Access

Introduction. Most of patients with unilateral hip disease shows muscle volume atrophy of pelvis and thigh in the affected side because of pain and disuse, resulting in reduced muscle weakness and limping. However, it is unclear how the muscle atrophy correlated with muscle strength in the patient with hip disorders. A previous study have demonstrated that the volume of the gluteus medius correlated with the muscle strength by volumetric measurement using 3 dimensional computed tomography (3D-CT) data, however, muscles influence each other during motions and there is no reports focusing on the relationship between some major muscles of pelvis and thigh including gluteus maximus, gluteus medius, iliopsoas and quadriceps and muscle strength in several hip and knee motions. Therefore, the purpose of the present study is to evaluate the relationship between muscle volumetric atrophy of major muscles of pelvis and thigh and muscle strength in flexion, extension and abduction of hip joints and extension of knee joint before surgery in patients with unilateral hip disease. Material and Methods. The subjects were 38 patients with unilateral hip osteoarthritis, who underwent hip joint surgery. They all underwent preoperative computed tomography (CT) for preoperative planning. There were 6 males and 32 females with average age 59.5 years old. Before surgery, isometric muscle strength in hip flexion, hip extension, hip abduction and knee extension were measured using a hand held dynamometer (µTas F-1, ANIMA Japan). Major muscles including gluteus maximus, gluteus medius, iliopsoas and quadriceps were automatically extracted from the preoperative CT using convolutional neural networks (CNN) and were corrected manually by the experienced surgeon. The muscle volumetric atrophy ratio was defined as the ratio of muscle volume of the affected side to that of the unaffected side. The muscle weakness ratio was defined as the ratio of muscle strength of the affected side to that of the unaffected side. The correlation coefficient between the muscle atrophy ratio and the muscle weakness ratio of each muscle were calculated. Results. The average muscle atrophy ratio was 84.5% (63.5%–108.2%) in gluteus maximus, 86.6% (65.5%–112.1%) in gluteus medius, 81.0% (22.1%–130.8%) in psoas major, and 91.0% (63.8%–127.0%) in quadriceps. The average muscle strength ratio was 71.5% (0%–137.5%) in hip flexion, 88.1% (18.8%–169.6%) in hip abduction, 78.6% (21.9%–130.1%) in hip extension and 84.3% (13.1%–122.8%) in knee extension. The correlation coefficient between the muscle atrophy and the ratio of each muscle strength between the affected and unaffected side were shown in Table 1. Conclusion. In conclusion, the muscle atrophy of gluteus medius muscle, psoas major muscle and quadriceps muscle significantly correlated with the muscle weakness in hip flexion. The muscle atrophy of psoas major muscle and quadriceps muscle also significantly correlated with the muscle weakness in knee extension. There were no significant correlation between the muscle atrophy and the muscle weakness in hip extension and abduction


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 120 - 120
1 Sep 2012
Shantz JA Leiter J MacDonald PB
Full Access

Purpose. The development of skills in arthroscopic surgery is essential to the training of modern orthopedic surgeons. Few validated, objective tools exist which track improvement in arthroscopic skills. The purpose of this study was to validate an objective global assessment of arthroscopic skills employing videotape footage of diagnostic arthroscopy performed by participants of various skill levels on a cadaveric knee. Method. A total of 22 participants with varying arthroscopic experience performed a recorded diagnostic knee arthroscopy on a cadaveric knee. Recorded footage of the procedures from an arthroscopic and external view was assessed by five blinded evaluators and scored on a global skills evaluation and checklist evaluation form. Interclass correlation coefficient analyses were used to determine the inter-rater reliability. Mean scores of novice and experienced residents and practicing arthroscopists (based on rank and experience) were compared using a students t-test. Results. Interclass correlation coefficient for the five raters on the global rating scale was 0.626 indicating moderate to good agreement. Interclass correlation coefficient for visual analogue scale skill measurement was 0.645. Discriminant validity was shown by the ability of the global assessment to differentiate novice (95% CI=24-29%) and experienced residents (95% CI=33-59%) from fellows (95% CI=70-87%) and knee arthroscopy staff (95% CI=79-84%). There was a ceiling effect based on the inability to differentiate fellows from knee arthroscopy staff. Conclusion. The Objected Assessment of Arthroscopic Skills global rating scale is a valid, reliable measure of arthroscopic skills in residents. It could be used for evaluative or educational purposes in orthopedic training. The method of blinded evaluation of participants provides a feasible method for the evaluation of resident arthroscopic skills with limited bias which could be implemented in training programs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 38 - 38
1 Mar 2013
Shon WY Suh DH Chun SK
Full Access

Introduction. Periprosthetic osteolysis following total hip arthroplasty is caused mainly by polyethylene wear particles and necessitates revision surgery at some stage even in the presence of well-fixed implants. Therefore, methods to estimate the polyethylene wear become important, with manual wear measurement methods as the main outcome measurement even in the presence of computer-assisted measurement methods on account of easy availability and simplicity in their use with reasonable accuracy. The purposes of this study were to quantify the accuracy and reproducibility of the slide presentation software method on clinical radiographs and to compare it with that of the previously described Livermore's method, and to determine the usefulness of the slide presentation software methods for highly cross linked polyethylene wear measurement. Materials and Methods. 81 hips out of 61 patients who underwent primary total hip arthroplasty between October 2000 and January 2006 were retrospectively evaluated for polyethylene wear by two independent observers using the Livermore's and the slide presentation software methods. All the hips were implanted with highly cross linked polyethylene acetabular liners with cementless acetabular components. The 28 mm sized cobalt chrome alloy femoral heads were used in all cases. The mean age of the patients was 50.8 years(range, 27–73 years), and the mean follow-up period was 6.6 years (range, 2–11 years). Paired radiographs were analyzed using the Livermore's and the slide presentation software method. For the Livermore's methods, radiographs were magnified to 200%, printed, and readings taken with digital calipers with an accuracy of 0.01 mm(Figure 1). For the slide presentation software method, we used Microsoft Office PowerPoint software(Microsoft Corp., Redmond, WA, USA) as described in a previous our study(Figure 2). Results. The mean polyethylene wear rate in 81 hips measured by the Livermore's method was found to be 0.071±0.12 and 0.081±0.09 mm/year by observer 1 and 2 respectively. The mean polyethyelene wear rate measured by slide presentation software method was found to be equally 0.069±0.07 mm/year by observer 1 and 2. Interobserver and intraobserver variance were evaluated using Pearson correlation coefficient. Correlation coefficients for interobserver variance were 0.802 for the Livermore's method and 0.979 for the slide presentation software method. Correlation coefficient for intraobserver variance were 0.777 for the Livermore's method and 0.965 for the slide presentation software method in observer 1, 0.303 for the Livermore's method and 0.941 for the slide presentation software method. The mean time consumed in each radiographic measurement with the Livermore's method was 15.52 minutes (range, 10.67–22 minutes) as compared to 9.55 minutes (range, 5.42–13.5 minutes) measured with the slide presentation software method (p < 0.001). Conclusion. The slide presentation software method was more accurate in serial intra-observer measurements and more reproducible in inter-observer readings for polyethylene wear than the traditional Livermore method, and was simple to use and less time consuming. Not all orthopaedic surgeons have access to CT for measuring polyethylene wear, hence the use of this type of manual method becomes a necessity on account of its easy availability and repeatability in serial measurements