Chondral defects in the knee have cartilage biomechanical differences due to defect size and orientation. This study examines how the tibiofemoral contact pressure is affected by increasing full-thickness chondral defect size on the medial and lateral
Cartilage diseases have a significant impact on the patient's quality of life and are a heavy burden for the healthcare system. Better understanding, early detection and proper follow-up could improve quality of life and reduce healthcare related costs. Therefore, the aim of this study was to evaluate if difference between osteoarthritic (OA) and non-osteoarthritic (non-OA) knees can be detected quantitatively on cartilage and subchondral bone levels with advanced but clinical available imaging techniques. Two OA (mean age = 88.3 years) and three non-OA (mean age = 51.0 years) human cadaveric knees were scanned two times. A high-resolution peripheral quantitative computed tomography (HR-pQCT) scan (XtremeCT, Scanco Medical AG, Switzerland) was performed to quantify the bone microstructure. A contrast-enhanced clinical CT scan (GE Revolution Evo, GE Medical Systems AG, Switzerland) was acquired with the contrast agent Visipaque 320 (60 ml) to measure cartilage. Subregions dividing the
Total temporomandibular joint (TMJ) replacements reduce pain and improve quality of life in patients suffering from end-stage TMJ disorders, such as osteoarthritis and trauma. Jaw kinematics measurements following TMJ arthroplasty provide a basis for evaluating implant performance and jaw function. The aim of this study is to provide the first measurements of three-dimensional kinematics of the jaw in patients following unilateral and bilateral prosthetic TMJ surgeries. Jaw motion tracking experiments were performed on 7 healthy control participants, 3 unilateral and 1 bilateral TMJ replacement patients. Custom-made mouthpieces were manufactured for each participant's mandibular and maxillary teeth, with each supporting three retroreflective markers anterior to the participant's lip line. Participants performed 15 trials each of maximum jaw opening, lateral and protrusive movements. Marker trajectories were simultaneously measured using an optoelectronic tracking system. Laser scans taken of each dental plate, together with CT scans of each patient, were used to register the plate position to each participant's jaw geometry, allowing 3D condylar motion to be quantified from the marker trajectories. The maximum mouth opening capacity of joint replacement patients was comparable to healthy controls with average incisal inferior translations of 37.5mm, 38.4mm and 33.6mm for the controls, unilateral and bilateral joint replacement patients respectively. During mouth opening the maximum anterior translation of prosthetic
Physiological kinematics is very difficult to restore after total knee arthroplasty (TKA). A new model of medial stabilized (MS) TKA prosthesis has a high spherical congruence of the internal compartment, which guarantees anteroposterior (AP) stability associated with a flat surface of the insert in the lateral compartment, that allows a greater AP translation of the external
This study was proposed to evaluate the efficacy of fibrin clot augmentation in meniscal tear using inside-out meniscal repair. A total of 35 patients with meniscus tears were operated on with inside-out meniscus repair and fibrin clot augmentation. Patients were evaluated preoperatively and postoperatively with clinical criteria, Lysholm knee scoring system, and MRI. Out of the total 35 cases, 5 cases were lost to follow up. Clinical improvement was observed in 29 out of 30 patients (96.6%). The mean Lysholm score improved significantly from 67.63 ± 6.55 points preoperatively to 92.0 ± 2.9 points postoperatively (P < 0.05) in 2 years follow-up. Follow-up MRI in all patients revealed complete healing except in 1 case where the patient presented with recurrence of symptoms such as pain and locking which resolved with partial meniscectomy. Paraesthesia in the anterior part of the knee was observed in 2 cases. (6.6%). We conclude that fibrin clot augmentation is a good cost-effective modality of treatment for repairable meniscus tears to preserve the meniscus and decrease the point contact pressure on the
Abstract. Objectives. This study aids the control of remodelling and strain response in bone; providing a quantified map of apparent modulus and strength in the proximal tibia in 3 anatomically relevant directions in terms of apparent density and factor groups. Methods. 7 fresh-frozen cadaveric specimens were quantified computed tomography (qCT) scanned, segmented and packed with 3 layers of 9mm side length cubic cores aligned to anatomical mechanical axes. Cores were removed with printed custom cutting and their densities found from qCT. Cores (n = 195) were quasi-statically compression tested. Modulus was estimated from a load cycle hysteresis loop, between 40% and 20% of yield stress. Sequential testing order in 3 orthogonal directions was randomised. Group differences were identified via an analysis of variance for the factors density, age, gender, testing order, subchondral depth,
Introduction. Degenerative meniscal tears are the most common meniscal lesions, representing huge clinical and socio-economic burdens. Their role in knee osteoarthritis (OA) onset and progression is well established and demonstrated by several retrospective studies. Effective preventive measures and non-surgical treatments for degenerative meniscal lesions are still lacking, also because of the lack of specific and accurate animal models in which test them. Thus, we aim to develop and validate an accurate animal model of meniscus degeneration. Method. Three different surgical techniques to induce medial meniscus degenerative changes in ovine model were performed and compared. A total of 32 sheep (stifle joints) were subjected to either one of the following surgical procedures: a) direct arthroscopic mechanical meniscal injury; b) peripheral devascularization and denervation of medial meniscus; c) full thickness medial femoral condyle cartilage lesion. In all the 3 groups, the contralateral joint served as a control. Result. From a visual examination of the knee joint emerged a clear difference between control and operated groups, in the menisci but also in the cartilage, indicating the onset of OA-related cartilage degeneration. The meniscal and cartilaginous lesions were characterized by different severity and location in the different groups. For instance, a direct meniscal injury caused cartilaginous lesions especially in the medial part of the
No proven long-term joint-preserving treatment options exist for patients with irreparable meniscal damage. This study aimed to assess gait kinematics and contact pressures of novel fibre-matrix reinforced polyvinyl alcohol-polyethylene glycol (PVA-PEG) hydrogel meniscus implanted ovine stifle joints against intact stifles in a gait simulator. The gait simulator controlled femoral flexion-extension and applied a 980N axial contact force to the distal end of the tibia, whose movement was guided by the joint natural ligaments (Bartolo; ORS 2021;p1657- LB). Five right stifle joints from sheep aged >2 years were implanted with a PVA-PEG total medial meniscus replacement, fixed to the tibia via transosseous tunnels and interference screws. Implanted stifle joint contact pressures and kinematics in the simulator were recorded and compared to the intact group. Contact pressures on the medial and lateral
The fixation of articular fractures, with many small osteochondral fragments, is a challenging unmet need where a bone adhesive would be a useful adjunct to standard treatments. Whilst there are no such adhesives in current clinical use, preclinical animal models have demonstrated good healing of bone in unloaded models using an adhesive based on phosphoserine modified calcium phosphate cement (PM-CPC). An ex-vivo human bone core model has shown that this adhesive bonds freshly harvested human bone. To confirm this adhesive is capable of supporting loaded osteochondral fragments a porcine model has been developed initially ex-vivo on the path to an in-vivo study. In this model bone cores, harvested from the medial knee
Introduction. Osteoarthritis (OA) often results from joint misloading, which affects chondrocyte calcium signaling through mechano-sensitive receptors such as Piezo1, -2, and TRPV4. Activation of Piezo1, especially under inflammatory conditions, can trigger premature chondrocyte apoptosis. Intra-articular glucocorticoid therapy, while beneficial against inflammation and pain in osteoarthritis, may induce oxidative stress and chondrotoxicity at higher doses. This study aims to assess the effects of glucocorticoids, particularly triamcinolone, on chondrocyte elasticity and mechanosignaling. Method. Chondrocytes isolated from articular
Despite the growing success of OCA transplantation in treating large articular cartilage lesions in multiple joints, revisions and failures still occur. While preimplantation subchondral drilling is intended to directly decrease allograft bioburden and has been associated with significant improvements in outcomes after OCA transplantation, the effects of size, number, and spacing of subchondral bone drill sites have not been fully evaluated. This study aimed to investigate the effects of drill size with or without pulse-lavage of OCA subchondral bone by quantifying remnant marrow elements using histomorphometry. With IRB and ACUC approvals, human and canine OCAs were acquired for research purposes. Portions of human tibial plateau OCAs acquired from AATB-certified tissue banks that would otherwise be discarded were recovered and sectioned into lateral and medial hemiplateaus (n=2 each) with a thickness of 7 mm. Canine femoral condyles and tibial plateaus were split into lateral and medial components with a thickness of 7 mm (n=8). Using our clinical preimplantation preparation protocol, holes were drilled into the subchondral bone of each
In this study, we developed biocompatible adhesive which enables implanted chondrogenic-enhanced hASCs being strongly fixed to the lesion site of defected cartilage. The bioengineered mussel adhesive protein (MAP) was produced and purified using a bacterial expression system as previously reported. The cell encapsulated coacervate was formulated with two polyelectrolyte, the MAP and 723kDa hyaluronic acid (HA). MAP formed liquid microdroplets with HA and subsequently gelated into microparticles, which is highly viscous and strongly adhesive. The MAP with chondro-induced hASCs were implanted on the osteochondral defect created in the patellar groove/
Abstract. OBJECTIVE. Knee varus malalignment increases medial knee compartment loading and is associated with knee osteoarthritis (OA) progression and severity. 1. Altered biomechanical loading and dysregulation of joint tissue biology drive OA progression, but mechanistic links between these factors are lacking. Subchondral bone structural changes are biomechanically driven, involve bone resorption, immune cell influx, angiogenesis, and sensory nerve invasion, and contribute to joint destruction and pain. 2. We have investigated mechanisms underlying this involving RANKL and alkaline phosphatase (ALP), which reflect bone resorption and mineralisation respectively. 3. and the axonal guidance factor Sema3A. Sema3A is osteotropic, expressed by mechanically sensitive osteocytes, and an inhibitor of sensory nerve, blood vessel and immune cell invasion. 4. Sema3A is also differentially expressed in human OA bone. 5. HYPOTHESIS: Medial knee compartment overloading in varus knee malalignment patients causes dysregulation of bone derived Sema3A signalling directly linking joint biomechanics to pathology and pain. METHODS. Synovial fluid obtained from 30 subjects with medial knee OA (KL grade II-IV) undergoing high tibial osteotomy surgery (HTO) was analysed by mesoscale discovery and ELISA analysis for inflammatory, neural and bone turnover markers. 11 of these patients had been previously analysed in a published patient-specific musculoskeletal model. 6. of gait estimating joint contact location, pressure, forces, and medial-lateral
Introduction and Objective. TKA have shown both excellent long-term survival rate and symptoms and knee function improvement. Despite the good results, the literature reports dissatisfaction rates around 20%. This rate of dissatisfaction could be due to the overstuff that mechanically aligned prostheses could produce during the range of motion. Either size discrepancy between bone resection and prosthetic component and constitutional mechanical tibiofemoral alignment (MTFA) alteration might increase soft tissue tension within the joint, inducing pain and functional limitation. Materials and Methods. Total knee arthroplasties performed between July 2019 and September 2020 were examined and then divided into two groups based on the presence (Group A) or absence (Group B) of patellofemoral overstuff, defined as a thickness difference of more than 2 mm between chosen component and bone resection performed, taking into account at least one of the following: femoral medial and lateral
Focal cartilage defects (FCDs) found in medial and lateral compartments of the knee are accompanied with patient-reported pain and loss of joint function. There is a deficit of evidence to explain why they occur. We hypothesise that aberrant knee joint loading may be partially responsible for FCD pathology, therefore this study aims to use 3-dimensional motion capture (MoCap) analysis methods to investigate differences in gait biomechanics of subjects with symptomatic FCDs. 11 subjects with Outerbridge grade II FCDs of the tibiofemoral joint (5 medial compartment, 6 lateral compartment) and 10 non-pathological controls underwent level-gait MoCap analysis using an infra-red camera (Qualisys) and force-plate (Bertec) passive marker system. 6-degree of freedom models were generated and used to calculate spatio-temporal measures, and frontal and sagittal plane knee, hip and ankle rotation and moment waveforms (Visual 3D). Principle component analysis (PCA) was used to score subjects based on common waveform features, and PC scores were tested for differences using Mann-Whitney tests (SPSS). No group differences were found in BMI, age or spatio-temporal measures. Medial-knee FCD subjects experienced higher (p=0.05) overall knee adduction moments (KAMs) compared to controls. Conversely, lateral-knee FCD subjects found lower (p=0.031) overall KAMs. Knee flexion and extension moments (KFMs/KEMs) were relatively reduced (p=0.013), but only in medial FCD subjects. This was accompanied by a significantly (p=0.019) higher knee flexion angle (KFA) during late-stance. KAMs have been shown to be predictive of frontal plane joint contact forces, and therefore our results may be reflective of FCD subjects overloading their respective diseased knee
The Temporomandibular joint (TMJ) is a complex and important joint for daily activities, and the alloplastic implant is recommended as the best solution, after repeated surgeries, failed autogenous grafts, highly inflammatory metabolic arthritis, fibrous or bony ankyloses. Some complications in total TMJ replacement are associated with implant design, screw fixation failure, implant displacement, fibrous tissue formation, (Speculand, et al. 2000). Some numeric studies evaluate the number of screws needed to guarantee the good fixation and suggest a minimum of three (Ramos et al. 2015), but is a controversy conclusion. The Biomet Microfixation TMJ stock prosthesis, Jacksonville, FL, USA is one of the three or four in the market. Clinical studies published by this device between 2005 and 2015 indicate a success rate of around 84 to 91% with improvements in mouth opening, a decrease in pain score and improved quality of life. The present study analyses experimentally the load transfer of this device. The intact, clean cadaveric ramus was instrumented with four rosettes model (KFG-1-120-D17-11 L3M2S, by Kywoa Electronic Instruments Co™, Japan), one in lateral region, two in lateral region and one in lingual face. The
Due to the increasing life expectancy the incidence of gonarthrosis, the degeneration of articular cartilage and bone in the knee joint, is increasing worldwide. Although the success rate of knee arthroplasties is high, complications like the loosening of the implant necessitate subsequent treatments. Moreover, the morphology and microstructure of the knee joint varies considerably between patients, therefore the anatomical expertise of orthopedic surgeons is essential. In this analysis we therefore investigate the variation and micro-architectural alterations in subchondral bone in osteoarthritis (OA) patients undergoing a knee replacement surgery. We investigate OA bone degenerations using clinical X-rays and micro-computed tomography (micro-CT). Tibial bone samples are collected from 100 patients undergoing a total knee arthroplasty at the Klinikum Wels-Grieskirchen. Images are obtained using an industrial micro-CT scanner RayScan 250E. Microstructural parameters include bone volume fraction and cortical thickness of the subcondral bone and are obtained from micro-CT images with isometric voxel sizes of 50 µm. Using micro-CT, we show a high morphological variation in relation to cortical thickness, both within the respective
Healthy cartilage is essential for optimal joint function. Although, articular cartilage defects are highly prevalent in the active population and might hamper joint function, the effect of articular cartilage defects on knee contact forces and pressures is not yet documented. Therefore, the present study compared knee contact forces and pressures between patients with a tibiofemoral cartilage defect and healthy controls. This might provide additional insights in movement adaptations and the role of altered loading in the progression from defect to OA. Experimental gait data was collected in 15 patients with isolated articular cartilage defects (8 medial-affected, 7 lateral-affected) and 19 healthy asymptomatic controls and was processed using a musculoskeletal model to calculate contact forces and pressures. Differences between medial-affected, lateral-affected and controls were evaluated using Kruskal-Wallis tests and individually compared using Mann-Whitney-U tests (alpha <0.05). The lateral-affected group walked significantly slower compared to the healthy controls. No adaptations in the movement pattern that resulted in decreased loading on the injured
Osteosynthesis of high-energy metaphyseal proximal tibia fractures is still challenging, especially in patients with severe soft tissue injuries and/or short stature. Although the use of external fixators is the traditional treatment of choice for open comminuted fractures, patients' acceptance is low due to the high profile and therefore the physical burden of the devices. Recently, clinical case reports have shown that supercutaneous locked plating used as definite external fixation could be an efficient alternative. Therefore, the aim of this study was to evaluate the effect of implant configuration on stability and interfragmentary motions of unstable proximal tibia fractures fixed by means of externalized locked plating. Based on a right tibia CT scan of a 48 years-old male donor, a finite element model of an unstable proximal tibia fracture was developed to compare the stability of one internal and two different externalized plate fixations. A 2-cm osteotomy gap, located 5 cm distally to the articular surface and replicating an AO/OTA 41-C2.2 fracture, was virtually fixed with a medial stainless steel LISS-DF plate. Three implant configurations (IC) with different plate elevations were modelled and virtually tested biomechanically: IC-1 with 2-mm elevation (internal locked plate fixation), IC-2 with 22-mm elevation (externalized locked plate fixation with thin soft tissue simulation) and IC-3 with 32-mm elevation (externalized locked plate fixation with thick soft tissue simulation). Axial loads of 25 kg (partial weightbearing) and 80 kg (full weightbearing) were applied to the proximal tibia end and distributed at a ratio of 80%/20% on the medial/lateral
Osteoarthritis (OA) is a progressive and degenerative joint disease resulting in changes to articular cartilage. In focal early OA defects, autologous chondrocyte implantation (ACI) has a 2-fold failure rate due to poor graft integration and presence of inflammatory factors (e.g. Interleukin-1β). Bone marrow derived mesenchymal stem cells (MSCs) are an alternative cell source for cell-based treatments due to their chondrogenic capacity, though in vivo implantation leads to bone formation. In vivo, chondrocytes reside under an oxygen tension between 2–7% oxygen or physioxia. Physioxia enhances MSC chondrogenesis with reduced hypertrophic marker (collagen X and MMP13) expression compared to hyperoxic conditions (20% oxygen). This study sought to understand whether implantation of physioxic preconditioned MSCs improves cartilage regeneration in an early OA defect model compared to hyperoxic MSCs. Bone marrow extracted from New Zealand white rabbits (male: 5–6 months old; n = 6) was split equally for expansion under 2% (physioxia) or 20% (hyperoxia) oxygen. Chondrogenic pellets (2 × 105 cells/pellet) formed at passage 1 were cultured in the presence of TGF-β1 under their expansion conditions and measured for their wet weight and GAG content after 21 days. During bone marrow extraction, a dental drill (2.5mm diameter) was applied to medial femoral condyle on both the right and left knee and left untreated for 6 weeks. Following this period, physioxia and hyperoxia preconditioned MSCs were seeded into a hyaluronic acid (TETEC) hydrogel. Fibrous tissue was scraped and then MSC-hydrogel was injected into the right (hyperoxic MSCs) and left (physioxia MSCs) knee. Additional control rabbits with drilled defects had fibrous tissue scrapped and then left untreated without MSC-hydrogel treatment for the duration of the experiment. Rabbits were sacrificed at 6 (n = 3) and 12 (n = 3) weeks post-treatment,