Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 58 - 58
1 Oct 2019
Mirick GM Sabin A Hansen G Lindgren B Aparicio C Carlson CS Bue M Larsen O Schmidt AH Kyle R Gustilo RB Tsukayama D Bechtold JE
Full Access

Introduction. We studied free (= local powder) tobramycin and doxycycline, and controlled release (= local lipid bilayer) doxycycline formulations in a rat model representing a generic joint infection. We . hypothesized. that evidence of infection (quantitative colony forming units (CFU), qualitative SEM, histopathology) (1a) would be reduced with local vs. systemic antibiotic, (1b) any antibiotic would be superior to control (2) there would be a difference among antibiotics, and (3) antibiotic would not be detectable in serum at 4-week euthanasia. Methods. Study groups. included infected and non-infected (1) control, (2) systemic ceftriaxone (daily), (3) local tobramycin, (4) local doxycycline and (5) controlled release doxycycline. With IACUC approval, (10 rats/group; power =0.8), 50-μl, 10×4 CFU Staphylococcus aureus, slowly injecting into distal femoral medullary canal, reliably created joint infection. Antibiotic formulation was introduced locally into cavity and joint, pin was inserted, and tissues closed. After 4-weeks, serum, pin, bone and synovium were obtained. CFU/ml of bone and synovium were quantified using macrotiter method. SEM imaged biofilm on surface of pin, histopathology identified tissue response, liquid chromatography/mass spectrometry measured plasma antibiotic. Kruskal-Wallis one-way ANOVA compared groups. Results. Groups receiving antibiotic reported lower CFU/ml in synovium compared with control (no treatment) group (1b), but there was no difference between systemic, free or controlled antibiotics (1a). Different results with different antibiotics were shown, with free tobramycin reducing CFU/ml to a greater extent than free doxycycline in the synovium (2) (p<0.05). Antibiotic in plasma was nondetectable all groups (3). SEM revealed some biofilm on pin in all groups. . Limitations. include inoculation method, single observation period, administration of only one bacterial and antibiotic dose, and not including pairing local and systemic antibiotic. Conclusion. There was no difference in infection reduction nor detectable antibiotic in serum for any antibiotic formulation, but CFU's in synovium differed based on antibiotic formulation. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 57 - 57
1 Oct 2019
Gil D Grindy S Hugard S Muratoglu OK Oral E
Full Access

Introduction. Ultra-high molecular weight polyethylene (UHMWPE) can provide local sustained delivery of therapeutics. 1,2. For example, it can deliver analgesics to address post-arthroplasty pain. 2. Given that several analgesics, such as bupivacaine (anesthetic) and tolfenamic acid (NSAID), were shown to possess antibacterial activity against Staphylococci, we hypothesize that analgesic-loaded UHMWPE can also yield antimicrobial effects, preventing the development of periprosthetic joint infections. Methods. Bupivacaine and tolfenamic acid were incorporated into UHMWPE via phase-separated compression molding. Drug release from the prepared samples was measured using high-performance liquid chromatography. Antibacterial studies of the obtained materials were conducted against methicillin-sensitive, and methicillin-resistant S. aureus, as well as S. epidermidis. Time-kill curves were obtained to characterize antimicrobial activity against planktonic bacteria. The dynamics of bacterial adhesion were assessed to characterize antibiofilm activity. Scanning electron microscopy (SEM) was used to visualize adherent bacteria. Anticolonizing activity of the tested materials was characterized using the “daughter cell” method as outlined elsewhere. 3. Cytotoxicity profile of drug-loaded UHMWPEs was evaluated using MG-63 osteoblast cell line. Results. The bupivacaine release rate generally increased with increasing drug loading (e.g. a model knee implant loaded with bupivacaine would release ca. 15–500 mg over 24 hours). While also proportional, drug release from UHMWPE loaded with tolfenamic acid was much lower. The bacterial viability curves showed that bupivacaine-loaded UHMWPE possessed moderate antibacterial activity against planktonic MSSA, MRSA, and S. epidermidis, slowing bacteria proliferation by up to 70%. Bupivacaine-loaded UHMWPE also mitigated biofilm formation and development during the initial culture period. SEM images confirmed the observed antibiofilm effect (Fig. 1). Tolfenamic acid-loaded UHMWPE allowed proliferation of planktonic bacteria. At the same time, these materials showed pronounced dose-dependent anticolonizing activity against tested strains, providing 3-log reduction of “daughter” cells. Bupivacaine- and tolfenamic acid-loaded UHMWPEs showed little-to-no cytotoxicity against osteoblasts. Discussion & Conclusions. We demonstrated for the first time that bupivacaine-loaded UHMWPE possesses dose-dependent antibacterial properties against planktonic and adherent MSSA, MRSA, and S. epidermidis – pathogens commonly associated with periprosthetic joint infections. Pronounced anticolonizing activity was evident for tolfenamic acid-loaded UHMWPE. Due to the low solubility of tolfenamic acid, the material's antibacterial effect against planktonic bacteria was lower. These results demonstrate that analgesic-loaded UHMWPE, used as a tool in multimodal pain management, can also yield antibacterial effects, opening an entirely new avenue for providing post-arthroplasty antibacterial prophylaxis. This pioneering approach has a potential to reduce patients' morbidity and mortality after arthroplasty. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 51 - 51
1 Jun 2016
Frew N Nichol T Smith T Stockley I
Full Access

Introduction. Vancomycin is commonly added to acrylic bone cement during revision arthroplasty surgery. Proprietary cement preparations containing vancomycin are available but significantly more expensive. We investigated whether the antibiotic elution and mechanical strength of ‘home-made’ vancomycin containing bone cement was comparable to commercial vancomycin-impregnated cement. Methods. A total of 18 cement discs of constant size, containing either proprietary CopalG+V. ®. ; or ‘home-made’ CopalR+G. ®. with vancomycin added by hand, were made. Each disc contained the same antibiotic quantities (0.5g gentamycin, 2g vancomycin) and was immersed in ammonium acetate buffer in a sealed container. Fluid from each container was sampled at eight time points over a two week period. The concentration of gentamicin and vancomycin in the fluid was analysed using high performance liquid chromatography mass spectrometry. The impact strength of each PMMA cement preparation was measured using a Charpy-type impact tester. Results. Highest peak antibiotic concentrations were observed from the ‘home-made’ vancomycin containing cement, added as in the operating theatre. Overall antibiotic elution was, five-fold (vancomycin) and two-fold (gentamicin), greater from the ‘home-made’ mix compared to commercially mixed cement. However the ‘home-made’ cements showed greater variation in elution kinetics compared to the commercial mix. Use of a vacuum during mixing had no significant effect on antibiotic elution in any of the samples. Impact strength testing showed no significant differences between the groups. Discussion. Our findings suggest the addition of 2g vancomycin powder to gentamicin-impregnated bone cement in theatre, significantly increases elution of both antibiotics, with no significant loss of strength, compared to commercially prepared cement. Conclusion. We have found no significant advantages of expensive off-the-shelf vancomycin-impregnated bone cement and recommend the addition of vancomycin powder by hand when making cement beads and spacers


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1156 - 1161
1 Nov 2000
Rafiq M Worthington T Tebbs SE Treacy RBC Dias R Lambert PA Elliott TSJ

Coagulase-negative staphylococci produce an exocellular glycolipid antigen which has potential as a serological marker of infection in bone. The value of this newly detected antigen was investigated by enzyme-linked immunosorbent assay (ELISA) in 15 patients with culture-proven infection of prostheses caused by Gram-positive bacteria. The antigen was purified by gel-permeation chromatography from the culture supernatants of coagulase-negative staphylococci grown in a chemically defined medium. There were significant differences (p < 0.0001) between the serum IgG and IgM levels in patients with infection due to Gram-positive staphylococci and those of a control group of 32 patients with no infection. The ELISA test, which has potential for the diagnosis of infection, may be valuable in distinguishing between staphylococcal infection around prostheses and aseptic loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 21 - 25
1 Jan 2007
Khan A Yates P Lovering A Bannister GC Spencer RF

We determined the effect of the surgical approach on perfusion of the femoral head during hip resurfacing arthroplasty by measuring the concentration of cefuroxime in bone samples from the femoral head. A total of 20 operations were performed through either a transgluteal or an extended posterolateral approach.

The concentration of cefuroxime in bone was significantly greater when using the transgluteal approach (mean 15.7 mg/kg; 95% confidence interval 12.3 to 19.1) compared with that using the posterolateral approach (mean 5.6 mg/kg; 95% confidence interval 3.5 to 7.8; p < 0.001). In one patient, who had the operation through a posterolateral approach, cefuroxime was undetectable.

Using cefuroxime as an indirect measure of blood flow, the posterolateral approach was found to be associated with a significant reduction in the blood supply to the femoral head during resurfacing arthroplasty compared with the transgluteal approach.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1430 - 1437
1 Nov 2006
Michalak KA Khoo PPC Yates PJ Day RE Wood DJ

Revision arthroplasty after infection can often be complicated by both extensive bone loss and a relatively high rate of re-infection. Using allograft to address the bone loss in such patients is controversial because of the perceived risk of bacterial infection from the use of avascular graft material. We describe 12 two-stage revisions for infection in which segmental allografts were loaded with antibiotics using iontophoresis, a technique using an electrical potential to drive ionised antibiotics into cortical bone.

Iontophoresis produced high levels of antibiotic in the allograft, which eluted into the surrounding tissues. We postulate that this offers protection from infection in the high-risk peri-operative period. None of the 12 patients who had two-stage revision with iontophoresed allografts had further infection after a mean period of 47 months (14 to 78).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1149 - 1157
1 Sep 2006
Khoo PPC Michalak KA Yates PJ Megson SM Day RE Wood DJ

Iontophoresis is a novel technique which may be used to facilitate the movement of antibiotics into the substance of bone using an electrical potential applied externally. We have examined the rate of early infection in allografts following application of this technique in clinical practice. A total of 31 patients undergoing revision arthroplasty or surgery for limb salvage received 34 iontophoresed sequential allografts, of which 26 survived for a minimum of two years. The mean serum antibiotic levels after operation were low (gentamicin 0.37 mg/l (0.2 to 0.5); flucloxacillin 1 mg/l (0 to 1) and the levels in the drains were high (gentamicin 40 mg/l (2.5 to 131); flucloxacillin 17 mg/l (1 to 43). There were no early deep infections. Two late infections were presumed to be haemotogenous; 28 of the 34 allografts were retained. In 12 patients with pre-existing proven infection further infection has not occurred at a mean follow-up of 51 months (24 to 82).