Advertisement for orthosearch.org.uk
Results 1 - 20 of 79
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 83 - 83
1 Mar 2013
Iwase T Kouyama A Matsushita N
Full Access

Introduction. Segmental defects of the femur present a major problem during revision hip arthroplasty. In particular, calcar segmental defects may compromise initial and long-tem femoral stem stability. Objective. The objective of the present study is to assess mid-term clinical and radiographic follow-up results at least two years after femoral revision comprising reconstruction for calcar segmental defect using metal wire mesh and impacted morcellised allograft. Methods. We performed 26 femoral revisions with calcar reconstruction in 24 patients between 2002 and 2010. The average age was 69.7 years, and the average follow-up period was 5 years and 1 month. All surgeries were performed using a cemented polished collarless tapered stem. The segmental calcar defect was reconstructed with metal wire mesh with doubled stainless wires. Large sized morcellised cancellous allograft was tightly impacted into the cavity between the phantom stem and the metal wire mesh. Nineteen hips were reconstructed with impaction bone grafting of the femur, and 7 hips with cement-in-cement technique except for the reconstructed calcar region.ã�� For clinical assessment, Merle d'Aubigné and Postel hip scores were recorded. For radiological assessment, antero-posterior hip radiographs were analyzed pre-operatively, and post-operatively at one month, 6 months and every 6 months thereafter. Clear lines around the femoral component using Gruen zone classification, stem subsidence in cement mantle, and change of stem axis were recorded. Kaplan-Meier survival analyses were performed with any re-operation of the femoral component or aseptic loosening as end points. In one case, the histological appearance of a biopsy specimen of the most proximal part of the reconstructed calcar, which was obtained at a later surgery for infection at 4 years after the revision, is described. Results. For clinical assessment, the mean Merle d'Aubigné and Postel hip scores improved from 10.4 points before the operation to 14.7 points at the final follow-up. For radiological assessment, no clear lines at the cement-bone interface and no stem axis changes were detected. Twenty-five of 26 hips showed less than 2 mm of stem subsidence at the final follow-up and one hip showed 2.2 mm stem subsidence. Both hips of one female patient underwent a one stage stem exchange because of an infection that occurred 48 months after revision. No cases showed aseptic loosening up to and including the last follow-up. The Kaplan-Meier survival analysis revealed that the survival rate at five years after revision was 88.0% with any type of re-operation on the femoral side as the endpoint and 100% with aseptic stem loosening as the endpoint, respectively. A biopsy specimen taken from the most proximal part of the reconstructed calcar region at 4 years after surgery in the infected case showed almost complete regeneration of viable bone with normal marrow spaces with partially formed granulation tissue. Conclusion. Reconstruction using metal wire mesh and tightly impacted morcellised allograft is a favorable method for the correction a calcar segmental defect. The procedure is simple and reliable, achieving initial and mid-term stem stability even for femurs with a complete calcar defect


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 48 - 48
1 Dec 2017
Demay O Renaud S Bredin S Diallo S Ohl X
Full Access

Aim

Chronic osteomyelitis of the calcaneus is a frequent problem in a population of diabetic patients, patients with neurologic disorders or bedridden patients with ulcers. Partial calcanectomy is an alternative option which avoid major amputation. The aim of this retrospective study was to determine the effectiveness of partial calcanectomy for treating chronic osteomyelitis of the calcaneux.

Method

We conducted a retrospective review of patients who underwent in our department a partial calcanectomy between 2006 and 2015. All patients with a complete set of radiographs and adequate follow-up (minimum 2 years) were included. We reviewed these cases to determine healing rate, microbiological analysis, risk factors of failure (comorbidities), limb salvage rate and survival rate. We analyzed specifically the footwear and the functional subjective evaluation according to the LEFS score (Lower Extremity Functional Scale).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 7 - 7
1 Sep 2014
Ajai A
Full Access

The lack of a universal, consistent protocol for the subjective, objective and radiographic evaluation of these injuries has hampered the comparison of results.

Methods

45 patients with complex fractures of the calcaneus were included in this prospective study, which was undertaken from July 2003 to December 2005. The fracture classification of Essex-Lopresti was used. We also observed the extent of secondary fracture lines extending from the primary shear line (on axial and external oblique plain radiographs) to establish comminution. The external oblique view for subtalar joint was performed with the patient supine, the knee at about 60 degree of flexion and the limb rotated externally 45 degree with a vertical X ray beam. All of these patients were managed by an external fixator using the principle of ligamentotaxis. Patients were evaluated by AOFAS.

Results

We identified two broad patterns of secondary lines on plain X-rays:

with anterior secondary fracture lines and

with posterior secondary fracture lines.

There were 20 cases of tongue type and 25 of joint depression type fracture pattern by the Essex-Lopresti classification. Forty two (93.4%) patients had fractures with posterior secondary fracture line and 3 (6.7%) patients had anterior secondary lines.

The calcaneo-cuboid type of anterior secondary line pattern was present in 2 (4.5%) cases, and the plantar type in only 1 (2.5%) case.

We observed posterior secondary line Type A pattern in 2 (4.5%) cases, depression / central depression type B in 20 (44.5%) cases, tongue shaped Type C pattern in 16 (36.5%) cases and Type D severely comminuted fracture line pattern in 4 (8.7%) cases.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 18 - 18
1 Jul 2014
Sinha A Selvan D Sinha A James L
Full Access

We present our experience of using tension band plates to achieve guided growth in children for correction of calcaneus deformity of the ankle.

11 consecutive patients (13 ankles) fulfilled the inclusion criteria over a 4-year period. All underwent surgical treatment using a flexible two hole plate and screws on the posterior aspect of distal tibial physis. Measurements were done on preoperative, intraoperative screening and 1-year post operative plain AP and lateral ankle radiographs. The anterior distal tibia angle (ADTA), lateral distal tibial angle (LDTA) and screw divergence angle (angle subtended by lines passing through the long axis of the screws) were used to assess the deformity correction. A 2 tailed student t-test was carried out on the initial and 1-year post-op measurements to determine statistical significance with a p value <0.05 considered as significant

There were 10 residual clubfoot deformities, 2 post-traumatic deformities and 1 spinal tumor causing deformity. The average age of the patients was 10 years 5 months (range 4 to 13 years). There were 9 males and 2 females. The ADTA showed a statistically significant change with a p value of 0.0008 with a mean correction of 8.6 degrees (range of 2.3 to 15.6 degrees). The SDA demonstrated a mean correction of 15.4 degrees (range 0.3 to 41.8 degrees), p=0.002. The LDTA did not change significantly (p= 0.08), thus confirming no coincidental coronal plane deformity had occurred. 5 ankles required revision of fixation due to metalwork reaching its maximum limit of divergence at an average of 1 year. 2 ankles had screw pulled out due to osteolysis around the screw. There were no cases of infection.

We report satisfactory short-term results of correction of calcaneus deformity using a flexible tension band plate and screws system.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 118 - 118
1 Jul 2020
Fletcher J Windolf M Gueorguiev B Richards G Varga P
Full Access

Proximal humeral fractures occur frequently, with fixed angle locking plates often being used for their treatment. However, the failure rate of this fixation is high, ranging between 10 and 35%. Numerous variables are thought to affect the performance of the fixation used, including the length and configuration of screws used and the plate position. However, there is currently limited quantitative evidence to support concepts for optimal fixation. The variations in surgical techniques and human anatomy make biomechanical testing prohibitive for such investigations. Therefore, a finite element osteosynthesis test kit has been developed and validated - SystemFix. The aim of this study was to quantify the effect of variations in screw length, configuration and plate position on predicted failure risk of PHILOS plate fixation for unstable proximal humerus fractures using the test kit. Twenty-six low-density humerus models were selected and osteotomized to create a malreduced unstable three-part fracture AO/OTA 11-B3.2 with medial comminution which was virtually fixed with the PHILOS plate. In turn, four different screw lengths, twelve different screw configurations and five plate positions were simulated. Each time, three physiological loading cases were modelled, with an established finite element analysis methodology utilized to evaluate average peri-screw bone strain, this measure has been previously demonstrated to predict experimental fatigue fixation failure. All three core variables lead to significant differences in peri-screw strain magnitudes, i.e. predicted failure risk. With screw length, shortening of 4 mm in all screw lengths (the distance of the screw tips to the joint surface increasing from 4 mm to 8 mm) significantly (p < 0 .001) increased the risk of failure. In the lowest density bone, every additional screw reduced failure risk compared to the four-screw construct, whereas in more dense bone, once the sixth screw was inserted, no further significant benefit was seen (p=0.40). Screw configurations not including calcar screws, also demonstrated significant (p < 0 .001) increased risk of failure. Finally, more proximal plate positioning, compared to the suggested operative technique, was associated with reduced the predicted failure risk, especially in constructs using calcar screws, and distal positioning increased failure risk. Optimal fixation constructs were found when placing screws 4 mm from the joint surface, in configurations including calcar screws, in plates located more proximally, as these factors were associated with the greatest reduction in predicted fixation failure in 3-part unstable proximal humeral fractures. These results may help to provide practical recommendations on the implant usage for improved primary implant stability and may lead to better healing outcomes for osteoporotic proximal fracture patients. Whilst prospective clinical confirmation is required, using this validated computational tool kit enables the discovery of findings otherwise hidden by the variation and prohibitive costs of appropriately powered biomechanical studies using human samples


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 51 - 51
7 Nov 2023
Nyalungu M Gqamana L
Full Access

To identify the demographics, mechanisms of injury and treatment modalities of patients presenting at CHBAH with calcaneal fractures. A retrospective study of all admitted patients with calcaneal fractures from 01 January 2018 to 31 December 2022. The data collected includes age, gender, side of injury, mechanism of injury, isolated injury versus polytrauma, open and close fractures, different treatment modalities and time to surgery. The descriptive data will be analysed, with results presented as frequency charts, histograms, and percentages. A total of 98 patients showed a male predominance of 90.8% compared to 9.2% of females. The median age was 38 years, the commonest mechanism was from falls from height, accounting for 67.3% with gunshot injuries accounting for 5%. Bilateral fractures were observed in 5 patients, with similar total numbers between those isolated to the left (47) as compared to the injuries isolated to the right side (46). Calcaneus fractures associated with other injuries in polytrauma cases were observed in 17.4%, and open fractures were observed in 7 patients with 5 having occurred post gunshot injury. A total of 48 patient required surgical treatment with the average time to surgery found to be 15 days. The surgical management varied, with open reduction and internal fixation with plate and screws in 68.7%, followed by 16.7% of patients who were treated with open reduction and internal screw fixation. Calcaneal fractures occurred frequently amongst male patients secondary to fall from height. Half of the total patient number admitted had require a surgical intervention to treat the fracture, with open reduction and internal fixation with plate and screws being the frequent mode of fixation in this population group


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 78 - 78
7 Nov 2023
Sikhauli N Pietrzak JR Sekeitto AR Chuene M Almeida R Mokete L
Full Access

Hip and knee joint arthroplasty wait list has been getting outrageously long in South Africa with some tertiary hospital reporting more than 5 years of waiting time. This has been further compounded by covid 19 pandemic. There is plateau of ideas on how best to address the backlogs in high volume tertiary centers, with catchup list, out reach program, private partnership seeming unsustainable. We sought to look for sustainable solution to the problem and we looked not far but inside the system. Method. Triggered by the fire that engulfed part of the hospital, we found ourself refuged at the sister tertiary hospital with no access to theatre time. We visited districts hospitals within the cluster and discovered state of the art facility underutilized. We presented a plan to establish a satellite arthroplasty center which was greatly embraced by the management. We partnered with the trade to setup an arthroplasty service in this district hospital. Employed 3 retired nurses and 2 parttime anaesthetist all on yearly contract. We developed pathways for patient selection according to American Society of Anaesthesiologist(ASA). 232 total joint arthroplasties were performed in 15-month, 33%Hips and 67%Knees. The average hospital stay was 2,3± 2days. We had 1 mortality(# NOF) and 2 cases of PJI treated successfully with debridement antibiotic and implant retention. We had 5 cases of intraoperative calcar femur fracture managed with cables and all stable at 6weeksand 3month. Over 76% of the cases were performed by fellows as the primary surgeons. Primary hip and knee total joint replacement can be safely performed in a district hospital. Employing motivated retired staff was key to the success of this project. Fellowship trainees performed most of the operations. We suggest that other academic hospitals with long waiting list can look at emulating this model within their district


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 77 - 77
10 Feb 2023
Hooper G Thompson D Lash N Sharr J Faulkner D Frampton C Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 12 - 12
3 Mar 2023
Dewhurst H Boktor J Szomolay B Lewis P
Full Access

Background. In recent years, ‘Get It Right First Time (GIRFT)’ have advocated cemented replacements in femoral part of Total hip arthroplasty (THA) especially in older patients. However, many studies were unable to show any difference in outcomes and although cemented prostheses may be associated with better short-term pain outcomes there is no clear advantage in the longer term. It is not clear when and why to do cemented instead of cementless. Aim. To assess differences in patient reported outcomes in uncemented THAs based on patient demographics in order to decide when cementless THA can be done safely. Method. Prospective data collection of consecutive 1079 uncemented THAs performed for 954 patients in single trust between 2010 and 2020. Oxford Hip Score (OHS) and complications were analysed against demographic variables (age, sex, BMI, ASA) and prosthesis features (femoral and acetabular size, offset and acetabular screws). Results. The mean pre-operative OHS was 14.6 which improved to 39.0 at 1 year follow up (P Value=0.000). There was no statistically significant difference between OHS outcome in patients aged over 70 versus younger groups. With a small number of revisable complications increase with age from 50s upwards. Male patients’ OHS score was on average 2.4 points higher than women. Men, however were 2.9 times more likely to experience fractures and high offset hips were 2.5 times more likely to experience dislocations. DAIR, intraoperative calcar fractures, post-operative fractures and dislocations were not associated with worse OHS. Patients with increased BMI had worse pre and post-operative hip functions yet, there was a significant multivariate association between increased BMI and increased improvement in OHS from pre-op to 1 year in women aged 55–80 and men under the age of 60. Femoral stem size increases with age but decreases in male patients over 80. There was no difference found in OHS between bilateral hip replacements and unilateral, nor was there any change found with laterality side of the replacement. Conclusions. This study suggests that ageing >70 is not associated with poorer outcomes despite small number of revisable complication rates that increase with age from 50 upwards. Men had marginally higher average OHS than women At 1 year. Higher BMI or ASA scores are associated with worse pre-operative hips and worse final outcome score. Despite this, the Delta OHS increases with increased BMI shown in the 55–80 year old female patients and male patients under 60. Key Words: THR, Uncemented, Oxford hip score, outcome


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 49 - 49
1 Apr 2019
Harman C Afzal I Shardlow D Mullins M Hull J Kashif F Field R
Full Access

INTRODUCTION. Historically, the clinical performance of novel implants was usually reported by designer surgeons who were the first to acquire clinical data. Regional and national registries now provide rapid access to survival data on new implants and drive ODEP ratings. To assess implant performance, clinical and radiological data is required in addition to implant survival. Prospective, multi-surgeon, multi-centre assessments have been advocated as the most meaningful. We report the preliminary results of such a study for the MiniHip™femoral component and Trinity™ acetabular component (Corin Ltd, UK). METHODS. As part of a non-designer, multi-surgeon, multi-centre prospective surveillance study to assess the MiniHip™stem and Trinity™ cup, 535 operations on 490 patients were undertaken. At surgery, the average age and BMI of the study group was 58.2 years (range 21 to 76 years) and 27.9 (range 16.3 to 43.4) respectively. Clinical (Harris Hip Score, HHS) and radiological review have been obtained at 6 months, 3 and 5 years. Postal Oxford Hip Score (OHS) and EuroQol- 5D (EQ5D) score have been obtained at 6 months and annually thereafter. To date, 23 study subjects have withdrawn or lost contact, 11 have died, and 9 have undergone revision surgery. By the end of March 2018, 6 month, 1, 2, 3, 4, and 5 year data had been obtained for 511, 445, 427, 376, 296 and 198 subjects respectively. RESULTS. Implant revision rate is 1.68% (9/535), with revision for any reason as an endpoint; four of the nine involved the revision of the femoral component. At the 5-year time point, mean OHS had improved from 21.3 to 42.5 (p<0.01), EQ5D from 0.42 to 0.82 (p<0.01), and HHS from 51.6 to 92.5 (p<0.01). Radiological analysis is ongoing, and thus far has revealed more variation in stem alignment than is usually observed for more conventional length femoral components. This may indicate that optimal alignment of calcar loading short stems is different to that of longer, medullary canal aligned implants, consistent with the neck-stabilised design of the MiniHip™ stem. No other significant radiological findings were noted. During surgery, 31 calcar fractures were sustained, of which 20 were treated with cerclage wiring, 1 with femoral grafting and the remainder required no treatment. None of the hips with calcar fractures have been revised to date. DISCUSSION. The clinical and radiological performance of the MiniHip™ femoral stem is consistent with established femoral implants. Longer surveillance will determine whether this performance is maintained. Patients in this study will be continued to be followed-up and reviewed at the 7 and 10-year time points. CONCLUSION. The MiniHip™ stem is safe and efficacious at mid-term follow-up


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 50 - 50
1 Jul 2020
Rouleau D Balg F Benoit B Leduc S Malo M Laflamme GY
Full Access

Treatment of proximal humerus fractures (PHF) is controversial in many respects, including the choice of surgical approach for fixation when using a locking plate. The classic deltopectoral (DP) approach is believed to increase the risk of avascular necrosis while making access to the greater tuberosity more difficult. The deltoid split (DS) approach was developed to respect minimally invasive surgery principles. The purpose of the present study (NCT-00612391) was to compare outcomes of PHF treated by DP and DS approaches in terms of function (Q-DASH, Constant score), quality of life (SF12), and complications in a prospective randomized multicenter study. From 2007 to 2016, all patients meeting the inclusion/exclusion criteria in two University Trauma Centers were invited to participate in the study. Inclusion criteria were: PHF Neer II/III, isolated injury, skeletal maturity, speaking French or English, available for follow-up (FU), and ability to fill questionnaires. Exclusion criteria: Pre-existing pathology to the limb, patient-refusing or too ill to undergo surgery, patient needing another type of treatment (nail, arthroplasty), axillary nerve impairment, open fracture. After consent, patients were randomized to one of the two treatments using the dark envelope method. Pre-injury status was documented by questionnaires (SF12, Q-DASH, Constant score). Range of motion was assessed. Patients were followed at two weeks, six weeks, 3-6-12-18-24 months. Power calculation was done with primary outcome: Q-DASH. A total of 92 patients were randomised in the study and 83 patients were followed for a minimum of 12 months. The mean age was 62 y.o. (+- 14 y.) and 77% were females. There was an equivalent number of Neer II and III, 53% and 47% respectively. Mean FU was of 26 months. Forty-four patients were randomized to the DS and 39 to the DP approach. Groups were equivalent in terms of age, gender, BMI, severity of fracture and pre-injury scores. All clinical outcome measures were in favor of the deltopectoral approach. Primary outcome measure, Q-DASH, was better statistically and clinically in the DP group (12 vs 26, p=0,003). Patients with DP had less pain and better quality of life scores than with DS (VAS 1/10 vs 2/10 p=0,019 and SF12M 56 vs 51, p=0,049, respectively). Constant-Murley score was higher in the DP group (73 vs 60, p=0,014). However, active external rotation was better with the DS approach (45° vs 35°). There were more complications in DS patients, with four screw cut-outs vs zero, four avascular necrosis vs one, and five reoperations vs two. Calcar screws were used for a majority of DP fixations (57%) vs a minority of DS (27%) (p=0,012). The primary hypothesis on the superiority of the deltoid split incision was rebutted. Functional outcome, quality of life, pain, and risk of complication favoured the classic deltopectoral approach. Active external rotation was the only outcome better with DS. We believe that the difficulty of adding calcar screws and intramuscular dissection in the DS approach were partly responsible for this difference. The DP approach should be used during Neer II and III PHF fixation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 19 - 19
1 Dec 2016
Pagnano M
Full Access

Intraoperative fractures during primary total hip arthroplasty (THA) can occur on either the acetabular or the femoral side. A range of risk factors including smaller incision surgery, uncemented components, prior surgery, female sex, osteoporosis, and inflammatory arthritis have been identified. Acetabular fractures are rare but when they do occur often are underrecognised. It is not uncommon for intraoperative acetabular fractures to be discovered only postoperatively. Intraoperative acetabular fractures are associated with cementless implants and a number of identified anatomic risk factors. Factors related to surgical technique, including excessive under-reaming, excessive medialization with aggressive reaming, and implant designs such as an elliptical cup design are associated with higher risk. Treatment of acetabular fractures is dependent on whether they are diagnosed intraoperatively or postoperatively. When discovered intraoperatively, supplemental fixation should be added in the form of additional screw fixation, placing a pelvic plate, or using an acetabular reconstruction cage and morselised allografts. Acetabular reamings, obtained during preparation of the acetabulum, can be used for local bone graft. The goal should be stability of both the fracture and acetabular cup. Postoperatively, weight bearing and mobilization protocols may require modification, with many surgeons choosing a period of toe-touch weight-bearing in such cases. Acetabular fractures found postoperatively require the surgeon to make a judgement on the relative stability of the implant and the fracture to determine if immediate revision surgery or protected weight-bearing alone is appropriate. On the femoral side intraoperative fractures can occur around the greater trochanter, the calcar, or in the diaphysis. Fractures of the greater trochanter are problematic because of their tendency to displace due to the attachment of the abductors and the strong force they apply. Tension band wiring techniques will work for many greater trochanteric fractures while a trochanteric plate may be occasionally called for. With either form of fixation strong consideration should be given to 6–8 weeks of protected weight bearing postoperatively. Short longitudinal cracks in the medial calcar region are not rare with uncemented implants. Calcar fractures that do not extend below the lesser trochanter can often be managed with a single cerclage cable. Calcar fractures extending below the lesser trochanter should be scrutinised with additional intraoperative xrays; longer longitudinal cracks can be managed with 2 cables while more complex fractures that exit the diaphysis demand a change to a distally fixed implant and formal fracture reduction. Distal diaphyseal fractures are relatively uncommon in the primary setting, but not rare in the revision setting. When recognised intraoperatively, distal diaphyseal fractures can be treated effectively with cerclage cables. Distal diaphyseal longitudinal cracks noted postoperatively do not typically mandate a return to the OR and instead can be managed with 8 weeks of protected weight bearing


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 11 - 11
1 Apr 2018
Sas A Kolk S Pellikaan P Scheerlinck T Van Lenthe H
Full Access

Introduction. Although total hip arthroplasty is a very successful operation, complications such as: dislocation, aseptic loosening, and periprosthetic fracture do occur. These aspects have been studied in large populations for traditional stem designs, but not for more recent short stems. The design rationale of short stems is to preserve bone stock, without compromising stability. However, due to their smaller bone contact area, high peak stresses and areas of stress shielding could appear in the proximal femur, especially in the presence of atypical bone geometries. In order to evaluate this aspect, we quantified the stress distribution in atypical proximal femurs implanted with a commercially available calcar guided short stem. Methods. Geometrical shape variations in neck-shaft angle (NSA), neck-length (NL) and anteversion (AV), were determined three-dimensionally in the Mimics Innovation Suite (Materialise N.V., Leuven, Belgium) from a CT dataset of 96 segmented femurs. For each shape variation, the femurs that had the two lowest, two average and two highest values were included (18 femurs). Using scripting functionality in Mimics, CAD design files of the calcar guided Optimys short stem (Mathys, Bettlach, Switzerland) were automatically sized and aligned to restore the anatomical hip rotation center. Stem size and position were manually corrected by an orthopedic surgeon before finite element (FE) models were constructed using a non-manifold assembly approach (Figure 1). Material properties were estimated from the CT dataset and loads representing walking and stair climbing were applied [1]. Stress-shielding was evaluated by the change in average strain energy density pre- and post-operatively in three different regions (calcar, midstem, tip) each being subdivided in four quarters (medial, lateral, anterior, posterior) (Figure 2). Results. Stress shielding in the proximal femur was seen in all models, especially in the calcar-medial region. In that region, the largest variation in stress shielding was observed for the models with an atypical NSA, ranging from 57% to 96%. The lowest amount was found in a patient with an average NSA (124°), and the highest amount was found in a patient with a small NSA (109°) (Figure 2). In the models selected for their varying neck lengths, calcar-medial stress shielding increased from 69% (NL 53 mm) to 97% (NL 66 mm). Stress shielding was least sensitive to variations in AV, ranging from 79% to 92%. Similar patterns were observed for walking and stair climbing loads. Discussion. Stress shielding was smallest in femurs where the load-transfer between implant and bone was located more proximally, while higher levels of stress shielding occurred when the load transfer was more pronounced at the tip of the stem (Figure 3). Two femurs with an average NSA and NL showed substantially lower stress shielding than the 16 other femurs. This may suggest that the calcar guided Optimys short stem prevents stress shielding especially in average femurs, but less so in atypical femurs. Hence, a larger study population should be investigated to support this hypothesis. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 57 - 57
1 Apr 2018
Dong N Yang S Zhu Z Wang A Gao J Qiu Y Zhang X
Full Access

Introduction. One of the objectives of total hip arthroplasty is to restore femoral and acetabular combined anteversion. It is desirable to reproduce both femoral and acetabular antevesions to maximize the acetabular cup fixation coverage and hip joint stability. Studies investigated the resultant of implanted femoral stem anteversion in western populations showed that the implanted femoral stems had only a small portion can meet the desirable femoral anteversion angle. 1. , and anteversion angle increases after the implantation of an anatomical femoral stem with anteverted stem neck comparing to anatomical femoral neck. 2. The purpose of this study was to anatomically measure the anteversion angular difference between metaphyseal long axis and femoral neck in normal Chinese population. The metaphyseal long axis represents the coronal fixation plane of modern cementless medial-lateral cortical fitting taper stem. This angular difference or torsion Δ angle provides the estimation of how much the neck antevertion angle of femoral stem would be needed to match for desirable anatomical femoral neck version. Methods. 140 (77 male and 63 female) anonymous normal adult Chinese CT data with average age of 54.6 (male 54.6, female 54.5, P=0.95) were segmented and reconstructed to 3D models in Trauson Orthopeadic Modeling and Analytics (TOMA) program. Femoral head center, femoral neck axis and center point of diaphyseal canal 100mm bellow calcar formed the femoral neck plane. The metaphyseal stem implantation plane was determined by the center point of medial calcar, proximal canal central axis formed by femoral neck plane and the center point of diaphyseal canal 100mm bellow calcar. [Fig. 1] The angle between two planes was the torsion Δ angle between femoral placement plane and anatomical femoral neck. [Fig. 2] The torsion Δ angles were measured for all 140 cases. The traditional anteversion angle for anatomical femoral neck was also measured by Murphy's method. Student T test was perform to compare the angles for male and female. The 98% confidence level was assumed. Results. The average torsion Δ angle for whole population was 4.9°(0.04°-15.6°), SD=3.52°, male: 4.6° (0.42°-13.9°), SD=3.09°; female: 5.3° (0.04°-15.6°), SD=3.98°. There was no statistical significant difference between genders. P=0.28. All metaphyseal stem placement planes were less anteverted than anatomical femoral neck plane. [Fig. 3] The average anatomical femoral neck anteversion angle for total population was 18.6° (0.27°-42.6°), SD=7.54°; male: 18.6° (0.27°-32.9°), SD=7.37°; female: 18.7° (1.74°-42.6°), SD=7.81°. There was no statistical significance between male and female P=0.92. Only 26% of study population or 37 cases with unadjusted implant neck version had normal anteversion angle of 10°-15° (Tönnis). Discussion. The study suggested femoral stem neck anteversion angle adjustments up to 11° was necessary to match anatomical femoral neck for 94% of cases in Chinese population. And the adjustments of 0°-7° represented the 76% majority of population. This finding was in agreement with the published data in western population. 2. . Significance. Variable femoral stem neck anteversion angles up to 11° are necessary to reproduce the anatomical anteversions for 94% of normal Chinese population. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 54 - 54
1 May 2013
Cameron H
Full Access

Femoral components in total hip replacements fail in well-known ways. There is vertical sink, posterior rotation and pivot, either distal or mid-stem. In order to sink, the stem moves into valgus and then slides down the inside of the calcar. It does not cut through the calcar. To prevent sink and pivot, a canal filling stem is required. Canal fill prevents the stem from moving into valgus and, therefore, it will not sink. Two centimeters with complete canal fill is adequate in a primary stem. A long stem will give longer canal fill in a revision. Sharp distal flutes will prevent rotation. The distal end of the stem should be polished. One is looking for a distal stability, not distal fixation. If the isthmus is intact, a primary stem can be used. If the isthmus is damaged, a long stem is necessary. If the calcar is intact, a primary neck is adequate. If the calcar is missing down to the level of the lesser trochanter, a calcar replacement neck is required. If there is more than 70 millimeters of completely missing proximal femur, a structural allograft is required. If the proximal femur is damaged, the ability to place a sleeve or collar to seek the best bone available independently of the stem version is very helpful. No matter how poor the proximal bone quality is, it can be supplemented by cerclage wires. The implant will sink only if the cerclage wires break. The advantage of proximal fixation is that loading the proximal femur speeds recovery. The huge disadvantage of distal fixation is removal of the implant should it become necessary. My long term results for the S-ROM stem used in revision are now out over 20 years. There were 119 primary stems with a minimum follow up of 5 years with no revisions for aseptic loosening. There were 262 long stems used. Nine (3.7%) underwent aseptic loosening. Most of these were due to technical errors due to my inexperience in the learning process of revision surgery. Four were dependent on strut-grafts and should have been treated with structural allografts. There were seven cases with structural allografts. Three were revised. Again, these were largely from problems arising from inexperience. I believe proximal modularity with distal stability allows the vast majority of revision cases to be treated with proximal fixation


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 16 - 16
1 Apr 2013
Shah A Badge R Joshi Y Choudhary N Sochart D
Full Access

Introduction. Negative remodelling of the femoral cortex in the form of calcar resorption due to stress shielding and cortical hypertrophy at the level of the tip of the implant, due to distal load transfer, is frequently noted following cemented total hip replacement, most commonly with composite beam implants, but also with polished double tapers. The C-stem polished femoral component was designed with a third taper running from lateral to medial across and along the entire length of the implant, with the aim of achieving more proximal and therefore more natural loading of the femur. The hoop stresses generated in the cement mantle are transferred to the proximal bone starting at the calcar, which should theoretically minimise stress-shielding and calcar resorption, as well as reducing distal load transfer, as signified by the development of distal femoral cortical hypertrophy. Materials/Methods. We present the results of a consecutive series of 500 total hip replacements performed between March 2000 and December 2005 at a single institution, using a standard surgical technique and third generation cementing with Palacos-R antibiotic loaded cement. Data was collected prospectively and the patients remain under annual follow-up. 500 arthroplasties were performed on 455 patients with an average age of 68.3 years (23–92). 77 patients have died (73 arthroplasties) and the average duration of follow-up for the entire series is 81 months (52–124). Results. Only 2 femoral implants have been revised - one for deep sepsis and the other as part of a revision procedure for a loose acetabulum, although the femoral component itself was not loose. One implant is currently loose following a periprosthetic fracture treated by internal fixation, but none of the other remaining implants demonstrates any progressive radiolucencies in any Gruen zones, or any features suggestive of current or future loosening. Rounding of the calcar has been observed, but there have been no cases with obvious loss of calcar height and no cases of distal femoral cortical hypertrophy. Conclusion. The C-stem femoral component has therefore performed well in clinical practice and the objective of eradicating negative bone remodelling has been achieved. The study is ongoing


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 220 - 220
1 Jun 2012
Sochart D Chaudhary N
Full Access

Negative remodelling of the femoral cortex in the form of calcar resorption due to stress-shielding, and femoral cortical hypertrophy at the level of the tip of the implant due to distal load transfer, is frequenly noted following cemented total hip replacement, most commonly with composite beam implants, but also with polished double tapered components. The C-stem polished femoral component was designed with a third taper running from lateral to medial across and along the entire length of the implant, with the aim of achieving more proximal and therefore more natural loading of the femur. The implant is designed to subside within the femoral cement mantle utilising the cement property of creep, generating hoop stresses, which are transferred more proximally to the femoral bone, starting at the level of the medial calcar. The intention is to load the proximal femur minimising stress-shielding and calcar resorption, as well as reducing distal load transfer as signified by the lack of distal femoral cortical hypertrophy. We present the results of a consecutive series of 500 total hip replacements using C-stem femoral components, performed between March 2000 and December 2005 at a single institution. Data was collected prospectively and all patients remain under annual follow-up by a Specialist Arthroplasty Practitioner. The operations were performed using a standard surgical technique with third generation cementing using Palacos-R antibiotic loaded cement. 500 arthroplasties were performed on 455 patients with an average age at the time of surgery of 68.3 years (23-92). There were 282 (62%) female and 173 (38%) male patients with osteoarthritis being the predominant diagnosis. 77 patients have died (73 hips) and the average duration of follow-up for the entire series is 81 months (52-124). Only 2 femoral implants have been revised - one for deep sepsis and the other as part of a revision procedure for a loose acetabulum, although the femoral component itself was not loose. One implant is currently loose following a periprosthetic fracture treated by internal fixation, but none of the remaining implants demonstrates any progressive radiolucencies in any Gruen zones or any features suggestive of current or future loosening. Calcar rounding has been observed, but there have been no cases with obvious loss of calcar height and no cases of distal femoral cortical hypertrophy. The C-stem femoral component has therefore performed well in clinical practice and the objective of eradicating negative bone remodelling has been achieved. The study is ongoing


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 354 - 354
1 Mar 2013
van der Rijt A Solaiman R van der Rijt R
Full Access

Conventional hip arthroplasty femoral stems bypass the femoral neck for fixation. The femoral neck and proximal femur has a complex anatomy and interosseous structure to facilitate transfer of mechanical load in axial, compression bending and torsion mechanisms. von Mises analysis suggests a short stem, fixed in the femoral neck would maintain proximal femoral biomechanics, achieve physiological load transfer to the femoral neck and preserve bone stock and function. The strong calcar bone provides excellent opportunities for implant fixation and load transfer. Method. The Muscle Sparing Arthroplasty (MSA™) is a short femoral stem designed to achieve implant fixation in the femoral neck. The specific design features including a trapezoidal cross section; proximal conical flare; porous coating and lateral T back enhance proximal fixation and compressive load transfer to the calcar and femoral neck. Results. We report 54 hip arthroplasties in 49 patients with an average follow up of 18 months. All hip arthroplasties showed evidence of new bone formation in the proximal femoral neck and calcar region. This consisted of new bone streaming from the original calcar bone, in a strut fashion up to the conical flare of the implant. In 18 patients additional new bone formation occurred proximal to the neck osteotomy. This pattern of bone formation is consistent with predictions. Conclusion. A short femoral stem, fixed in the femoral neck can maintain biomechanical function of the femoral neck and result in preservation of bone and new bone stock


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 290 - 290
1 Mar 2013
Oh K Mishra A
Full Access

Interestingly, recent studies have shown promising outcomes in elderly. To the best of our knowledge there are no reports available assessing sequential bone remodelling around DCPD (dicalcium phosphate dehydrate) coated short metaphyseal loading stem using serial radiography. Hence we report the unique patterns of bone remodelling in patients 70 years and older and whether these patterns were different from those seen in younger patients. A total of 41 consecutive primary hip arthroplasties were performed in patients with averaged age of 78.3 years using short stem. The presence and patterns of radiolucent lines, radio-opaque lines, calcar rounding, proximal bone resorption, spot welds, cortical hypertrophy, and intramedullary bone formation around the distal tip were assessed at serial radiography up to averaged follow up of 24.5 months. In early stage of stability, the radio-opaque line appeared in lateral aspect of stem which might means the tension force of stem. On the contrary to this findings, the medial side of stem mainly showed the spot welds due to compression on calcar support. The sequential radiographic bone remodelling in 70 years and older showed the different pattern from those of 30 to 50 year-old. Formation of new endosteal trabeculation (spot welds) were seen only in 55.6% of stems among the elderly study group where as all patients showed spot welds in the younger group. Calcar resorption was often observed in younger group but the degree of calcar resorption was less. The other findings in elderly patients was not different compared to those of younger patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 16 - 16
1 Jun 2018
Berry D
Full Access

The Failed Femoral Neck Fracture. For the young patient: Attempt to preserve patient's own femoral head. Clinical results reasonably good even if there are patches of avascular necrosis. Preferred methods of salvage: valgus-producing intertrochanteric femoral osteotomy: puts the nonunion under compression. Other treatment option: Meyer's vascularised pedicle graft. For the older patient: Most reliable treatment is prosthetic replacement. Decision to use hemiarthroplasty (such as bipolar) or THA based on quality of articular cartilage, perceived risk of instability problem. In most patients THA provides higher likelihood of excellent pain relief. Specific technical issues: (1) hardware removal: usually remove after hip has first been dislocated (to reduce risk of femur fracture); (2) Hip stability: consider methods to reduce dislocation risk: larger diameter heads/dual mobility/anteriorly-based approaches; (3) Acetabular bone quality: poor because it is not sclerotic from previous arthritis; caution when impacting a pressfit cup; low threshold to augment fixation with screws; don't overdo reaming; just expose the bleeding subchondral bone. A reasonable alternative is a cemented cup. The Failed Intertrochanteric Hip Fracture. For the young patient: Attempt to salvage hip joint with nonunion takedown, autogenous bone grafting and internal fixation. For the older patient: Decision to preserve patient's own hip with internal fixation versus salvage with hip arthroplasty should be individualised based on patient circumstances, fracture pattern, bone quality. THA is an effective salvage procedure for this problem in older patients. If prosthetic replacement is chosen special considerations include:. THA vs. hemiarthroplasty: hemiarthroplasty better stability; THA more reliable pain relief. Removal of hardware: be prepared to remove broken screws in intramedullary canal. Management of bone loss: bone loss to level of lesser trochanter common. Often requires a calcar replacement implant. Proximal calcar build-up size dictated by bone loss. Length of stem: desirable to bypass screw holes from previous fixation, if possible. Stem fixation: cemented or uncemented fixation depending on surgeon preference, bone quality. If uncemented, consider diaphyseal fixation. Greater trochanter: often a separate piece, be prepared to fix with wires or cable grip. Residual trochanteric healing, hardware problems not rare after THA