Advertisement for orthosearch.org.uk
Results 1 - 20 of 70
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 34 - 34
1 May 2016
Hayashi S Hashimoto S Kanzaki N Kuroda R Kurosaka M
Full Access

Purpose. The purpose of this study was to evaluate periprosthetic bone mineral density (BMD) changes around a cementless short tapered-wedge stem and determine correlations between BMD changes and various clinical factors, including daily activity, after total hip arthroplasty (THA) with a short tapered-wedge stem. Methods. The study included 65 patients (65 joints) who underwent THA with a TriLock stem. At baseline, and 6, 12, and 24 months postoperatively, BMDs of the seven Gruen zones were evaluated using dual-energy X-ray absorptiometry. Correlations were determined between BMD changes and clinical factors, including the Harris hip score, body mass index, University of California at Los Angeles (UCLA) activity rating score, age at surgery, and initial lumbar BMD. Results. Minimal BMD changes were noted in the distal femur (Gruen zones 3, 4, and 5). However, significant BMD loss was noted in zone 7 at each time point. BMD loss was also noted in zone 1 at 6 and 12 months postoperatively, but BMD recovered after 18 months. Significant positive correlations were noted between BMD changes and the UCLA activity rating score in zones 1, 6, and 7. Additionally, negative correlations were noted between BMD changes and initial spine BMD in zones 2 and 3. Table legends. Table 1 Background of the patients. Table 2 Bone mineral density changes (%) at 6, 12, and 24 months postoperatively in the seven Gruen zones. Columns represent mean ± standard deviation. ※indicates P < 0.05 compared with baseline bone mineral density. Table 3 Correlations between periprosthetic bone mineral density changes and clinical factors (the Harris hip score, body mass index, University of California at Los Angeles activity rating score, age at surgery, and initial lumbar bone mineral density) in the seven Gruen zones at 24 months postoperatively. Correlation coefficients and P-values are presented. Boldface indicates P < 0.05. Conclusion. Periprosthetic BMD was maintained in the proximal femur, especially Gruen zone 1, with a short tapered stem. Daily activity may reflect improvements in periprosthetic bone quality after THA with a short tapered stem; however, this stem is not recommended in patients with low bone quality. To view tables, please contact authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 77 - 77
10 Feb 2023
Hooper G Thompson D Lash N Sharr J Faulkner D Frampton C Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 525 - 525
1 Dec 2013
Scott D
Full Access

Introduction:. Significant proximal femoral remodeling occurs after total hip arthroplasty (THA), with regions of bone loss, and regions of hypertrophy. This study compared three implants for changes in femoral bone mineral density over 2 years following primary uncemented hip arthroplasty with a conventional stem (THA), a novel femoral neck-sparing short hip stem (NS-THA), and resurfacing hip arthroplasty (RHA). Methods:. Seventy-one patients participated in this non-randomized, prospective study. All patients had a diagnosis of osteoarthritis and underwent primary uncemented hip arthroplasty. Dual Energy XRay Absorptomitry (DXA) scans were performed at preoperative, 3–7 days post-op, 6 weeks, 6 months, one, and two years post-op. Using custom 2 cm zones, 19 zones were observed for percent changes in bone mineral density (BMD). Radiographs and Harris Hip scores were obtained at each visit. Results:. Age, gender, and BMI were found to be statistically different with fewer females and lower age in the RHA group, and a lower age in the NS-THA group. In all three groups, regions that were located proximally were shown to be the most susceptible to bone loss. Combined 2 cm zones 1C/7C, 2A/6A, and 2B/6B showed statistical significance (p < 0.05). Bone loss in the proximal regions was 8–10% lower with the femoral neck-sparing short stem, and least in the RHA group, causing little to no BMD loss in proximal regions. Radiographic outcomes and clinical results including Harris Hip scores were equal between the groups. Conclusion:. Consistent with our hypothesis, it was found that hip arthroplasty with a conventional stem resulted in the highest proximal femoral bone loss, and resurfacing arthroplasty was associated with the least bone loss. The femoral neck-sparing short stem ameliorated the bone loss seen with traditional hip arthroplasty, and approximated the bone preservation seen with hip resurfacing. The short stem neck-sparing device may provide some of the benefits of hip resurfacing, but could potentially have wider indications for use


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 65 - 65
1 Aug 2013
Munting T Verrier M
Full Access

Purpose of study:. The purpose of the study is to evaluate the changes in peri-prosthetic bone mineral density following cemented and cementless total hip arthroplasty over a follow up period of 1 year. Description of methods:. Ethics approval was sought and granted by the South African Medical Association Research Ethics Committee (SAMAREC). Patient consent for participation was obtained. Recruitment of the cohort took place over 2 years. Patients received an uncemented (Synergy) or cemented (Spectron) prosthesis as clinically appropriate. Functional status according to the University of California Los Angeles activity scale (UCLA scale) and bone mineral density as measured by Dual Energy X-ray Absorptiometry (DEXA) was assessed pre-operatively and at 3 months, 6 months and 12 months post-operatively. An independent Contract Research Organisation was used to monitor the site. Summary of results:. As at August 2010, 59 unique patients had undergone 59 hip replacements, and 7 patients (8.5%) were still due their 12 month evaluation. The mean UCLA scored showed a marked and steady improvement post-operatively, with most of the gain demonstrated by 3 months. When evaluating all patients, the mean pre-operative values for Gruen Zones 2, 4, and Net were significantly lower than the mean 12 month values. When evaluating patients who received the uncemented prosthesis (n=40), the mean pre-operative values for Gruen Zones 2 and Net were significantly lower than the mean 12 month values, and the mean pre-operative values for Gruen Zones 1 and 3 were significantly higher than the mean 12 month values. When evaluating patients who received the cemented prosthesis (n=19), the median pre-operative values for Gruen Zones 1, 2, 3, 4, 7 and Net were significantly lower than the median 12 month values. Conclusion:. At 1 year post surgery overall bone density showed a significant increase in both the cemented and uncemented cohort


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 239 - 239
1 Dec 2013
Berahmani S Janssen D Wolfson D De Waal Malefijt M Verdonschot N
Full Access

To achieve desirable outcomes in cementless total knee replacement (TKR), sufficient primary stability is essential. The primary stability inhibits excessive motions at the bone-implant interface, hence providing the necessary condition for osseointegration [1]. Primary stability for cementless TKR is provided by press-fit forces between the bone and implant. The press-fit forces depend on several factors including interference fit, friction between bone and implant surface, and the bone material properties. It is expected that bone mineral density (BMD) will affect the stability of cementless TKR [2]. However, the effect of BMD on the primary stability of cementless femoral knee component has not been investigated in vitro. Phantom calibrated CT-scans of 9 distal femora were obtained after the surgical cuts were made by an experienced surgeon. Since the press-fit forces of the femoral component mainly occur in the Anteroposterior (AP) direction, the BMD was measured in the anterior and posterior faces for a depth of 5 mm; this depth was based on stress distributions from a Finite Element Analysis of the same implant design. In addition, four strain gauges were connected to different locations on the implant's outer surface and implant strain measured throughout as an indication of underlying bone strain. A cementless Sigma CR femoral component (DePuy Synthes Joint Reconstruction, Leeds, UK) was then implanted using an MTS machine. In order to simulate a ‘normal’ bone condition, the implanted bone was preconditioned for one hour at a cyclic load of 250–1500 N, and a rate of 1 Hz. Finally, the implants were pushed-off from the bone in a high-flex position. Forces and displacements were recorded both during insertion and push-off tests. Strong correlations were found for insertion and push-off forces with BMD, R. 2. = 0.88 and R. 2. = 0.88, respectively (p < 0.001), so although implantation may be harder in patients with higher BMD, initial stability is also improved. A correlation was also found between final strain and push-off forces (R. 2. = 0.89, p < 0.01) and BMD also showed a strong reverse correlation with total bone relaxation (R. 2. = 0.76, p = 0.023). These results indicate that higher BMD induces higher bone strain, which can lead to improved fixation strength. There is no consensus on the best fixation method for the TKR but some surgeons prefer a cementless design for young and active patients. The results of our study showed that the primary stability of a cementless femoral knee component is directly correlated with the bone mineral density. Therefore, patient selection based on bone quality may increase the likelihood of good osseointegration and adequate long-term fixation for cementless femoral knee components


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 42 - 42
1 Sep 2012
Hooper G Gilchrist N Frampton C Maxwell R Heard A Mcguire P
Full Access

Bone mineral density (BMD) and bone mineral content (BMC) have not been previously assessed in unicompartmental knee replacement (UKR). We studied the early bone changes beneath the uncemented Oxford medial UKR. Our hypothesis was that this implant should decrease the shear stresses across the bone-implant interface and result in improved BMD and BMC beneath the tibial component. Using the Lunar iDXA and knee specific software we developed 7 regions of interest (ROI) in the proximal tibia and assessed 38 patients with an uncemented Oxford UKR at 2 years. We measured the replaced knee and contralateral unreplaced knee using the same ROI and compared the BMD and BMC. The initial precision study in 20 patients demonstrated high precision in all areas. There were 12 males and 16 females with an average age of 65.8 years (46–84 years). ROI 1 and 2 were beneath the tibial tray and had significantly less BMC (p=0.023 and 0.001) and BMD (p=0.012 and 0.002). ROI 3 was the lateral tibial plateau and this area also had significantly less BMC (p=0.007) and BMD (p=0.0001). ROI 4 and 5 immediately below the tibial keel had no significant change. These changes were independent of gender and age. These results were surprising in that the universal loss of BMC and BMD suggested that bone loading of the proximal tibia was not improved even after a UKR. The better BMD and BMC adjacent to the keel confirms other studies that show improved bone in-growth around keels and pegs in the uncemented tibial component. A prospective longitudinal study has been developed to compare BMD and BMC changes over time to see whether these changes are dynamic


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 40 - 40
1 Jul 2020
Farzi M Pozo JM McCloskey E Eastell R Frangi A Wilkinson JM
Full Access

In conventional DXA (Dual-energy X-ray Absorptiometry) analysis, pixel bone mineral density (BMD) is often averaged at the femoral neck. Neck BMD constitutes the basis for osteoporosis diagnosis and fracture risk assessment. This data averaging, however, limits our understanding of localised spatial BMD patterns that could potentially enhance fracture prediction. DXA region free analysis (RFA) is a validated toolkit for pixel-level BMD analysis. We have previously deployed this toolkit to develop a spatio-temporal atlas of BMD ageing in the femur. This study aims first to introduce bone age to reflect the overall bone structural evolution with ageing, and second to quantify fracture-specific patterns in the femur. The study dataset comprised 4933 femoral DXA scans from White British women aged 75 years or older. The total number of fractures was 684, of which 178 were reported at the hip within a follow-up period of five years. BMD maps were computed using the RFA toolkit. For each BMD map, bone age was defined as the age for which the L2-norm between the map and the median atlas at that age is minimised. Next, bone maps were normalised for the estimated bone age. A t-test followed by false discovery rate (FDR) analysis was applied to compare between fracture and non-fracture groups. Excluding the ageing effect revealed subtle localised patterns of loss in BMD oriented in the same direction as principal tensile curves. A new score called f-score was defined by averaging the normalised pixel BMD values over the region with FDR q-value less than 1e–6. The area under the curve (AUC) was 0.731 (95% confidence interval (CI)=0.689–0.761) and 0.736 (95% CI=0.694–0.769) for neck BMD and f-score. Combining bone age and f-score improved the AUC significantly by 3% (AUC=0.761, 95% CI=0.756–0.768) over the neck BMD alone (AUC=0.731, 95% CI=0.726–0.737). This technique shows promise in characterizing spatially-complex BMD changes, for which the conventional region-based technique is insensitive. DXA RFA shows promise to further improve fracture prediction using spatial BMD distribution


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 159 - 159
1 Sep 2012
Beaulé PE Dinh L Gauthier L Kim PR Feibel RJ Thurston PR Giachino AA
Full Access

Purpose. Use of a large femoral head metal-on-metal bearing in total hip arthroplasty may offer an advantage in terms of dislocation rates and more natural joint kinematics. The acetabular component is more rigid however in these prostheses and if not placed accurately can lead to increased levels of metal ion release. A prospective randomized controlled trial was conducted to quantify bone mineral density on the acetabular side, as well as compare metal ion levels from a standard metal-on-polyethylene bearing to a large head metal-on-metal bearing in primary total hip arthroplasty. Method. Fifty patients were randomized to receive total hip arthroplasty with either the CONSERVE A-Class Total Hip with BFH femoral head or the Lineage acetabular component with polyethylene insert and cobalt chrome femoral head. There were 27 females (11 BFH) and 23 males (14 BFH), with a mean overall age of 61.6 (range 47.7–73.2). Serum levels of cobalt, chromium, and titanium were measured at regular intervals up to two years. Harris Hip Score, WOMAC, UCLA, and RAND-36 were completed at these same intervals. Standard radiographs as well as periprosthetic BMD were performed. Results. Bone mineral density in acetabular zones II, III, and IV was greater in the BFH group compared with the metal on poly group (p= 0.030, 0.046, and 0.019 respectively). Serum levels of cobalt (2.31 microg/mL vs 0.23 microg/mL, p=<0.001) and chromium (1.53 microg/mL vs 0.21 microg/mL, p=<0.001) were statistically higher in the BFH group compared with the metal-on-polyethylene group at one year post-op. There was no significant difference in serum titanium levels between groups. Conclusion. At short term follow up the load transfer to the acetabular bony bed differed between the two groups, with the more rigid shells demonstrating increased BMD in certain zones when compared with metal on poly. Serum levels of certain ions were 7–15 fold higher in the metal-on-metal large femoral head design compared with a standard metal-on-polyethylene. We await results on any clinical differences in performance and complications in this group of patients. Systemic implications of these ion levels are not known and further study is warranted


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 4 - 4
1 Apr 2018
Baetz J Messer P Lampe F Pueschel K Klein A Morlock M Campbell G
Full Access

INTRODUCTION. Loosening is a major cause for revision in uncemented hip prostheses due to insufficient primary stability. Primary stability after surgery is achieved through press-fit in an undersized cavity. Cavity preparation is performed either by extraction (removing bone) or compaction (crushing bone) broaching. Densification of trabecular bone has been shown to enhance primary stability in human femora; however, the effect of clinically used compaction and extraction broaches on human bone with varying bone mineral density (BMD) has not yet been quantified. The purpose of this study was to determine the influence of the broach design and BMD on the level of densification at the bone-cavity interface, stem seating, the bone-implant contact area and the press-fit achieved. METHODS. Paired human femora (m/f=11/12, age=60±18 y) were scanned with quantitative computed tomography (QCT, Philips Brilliance 16) before broaching, with the final broach, after its removal and after stem implantation. Compaction broaching (n=4) was compared in an in situ (cadaver) study against extraction broaching with blunt tooth types (n=3); in an ex situ (excised femora) study, compaction broaching was compared against extraction broaching with sharp tooth types (n=8 each). QCT data were resampled to voxel sizes of 1×1×1 mm (in situ) and 0.5×0.5×1 mm (ex situ). Mean trabecular BMD of the proximal femur was determined. The cavity volumes were segmented in the post-broach images (threshold: −250 mgHA/cm3, Avizo 9.2) and a volume of interest (VOI) of one-voxel thickness was added around the cavity to capture the interfacial bone. VOIs were transferred to the pre-broach image and bone densification was calculated within each VOI as the increase from pre- to post-broach image (MATLAB). Detailed surface data sets of broaches and stems were collected with a 3D laser-scanner (Creaform Handyscan 700) and aligned with the segmented components in the CT scans (Fig. 1). Stem seating was defined as the difference between the top edge of the stem coating and the final broach. Distance maps between the stem and cavity surface were generated to determine the bone-implant contact area and press-fit. All parameters were analysed between 5 mm distal to the coating and 1 cm distal to the lesser trochanter and analysed with related-samples Wilcoxon signed rank and Spearman's correlation tests (IBM SPSS Statistics 22). RESULTS. Trabecular BMD ranged from 81 to 221 mgHA/cm3. Densification was higher with compaction compared to sharp (p=0.034), but not blunt extraction broaching (p=1.000). Proximal bone-implant contact area, press-fit and stem seating did not differ between broaching methods. Bone-implant contact area and bone densification increased with trabecular BMD (rs=0.658, p=0.001 and rs=0.443, p=0.034), press-fit with stem seating (rs=0.746, p<0.001) and contact area with bone densification (rs=0.432, p=0.039). DISCUSSION. Sharp extraction broaching reduces densification at the bone-cavity interface, but does not affect the press-fit or contact area. Trabecular BMD was positively associated with contact area, and stem seating with press-fit. Future studies will aim to link these findings to primary stability and influence on periprosthetic fractures. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 39 - 39
1 Aug 2020
Ma C Li C Jin Y Lu WW
Full Access

To explore a novel machine learning model to evaluate the vertebral fracture risk using Decision Tree model and train the model by Bone Mineral Density (BMD) of different compartments of vertebral body. We collected a Computed Tomography image dataset, including 10 patients with osteoporotic fracture and 10 patients without osteoporotic fracture. 40 non-fracture Vertebral bodies from T11 to L5 were segmented from 10 patients with osteoporotic fracture in the CT database and 53 non-fracture Vertebral bodies from T11 to L5 were segmented from 10 patients without osteoporotic fracture in the CT database. Based on the biomechanical properties, 93 vertebral bodies were further segmented into 11 compartments: eight trabecular bone, cortical shell, top and bottom endplate. BMD of these 11 compartments was calculated based on the HU value in CT images. Decision tree model was used to build fracture prediction model, and Support Vector Machine was built as a compared model. All BMD data was shuffled to a random order. 70% of data was used as training data, and 30% left was used as test data. Then, training prediction accuracy and testing prediction accuracy were calculated separately in the two models. The training accuracy of Decision Tree model is 100% and testing accuracy is 92.14% after trained by BMD data of 11 compartments of the vertebral body. The type I error is 7.14% and type II error is 0%. The training accuracy of Support Vector Machine model is 100% and the testing accuracy is 78.57%. The type I error is 17.86% and type II error is 3.57%. The performance of vertebral body fracture prediction using Decision Tree is significantly higher than using Support Vector Machine. The Decision Tree model is a potential risk assessment method for clinical application. The pilot evidence showed that Decision Tree prediction model overcomes the overfitting drawback of Support Vector Machine Model. However, larger dataset and cohort study should be conducted for further evidence


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 12 - 12
1 Apr 2018
Moharamzadeh D Piarulli G Molisani D Andreoletti G
Full Access

Cementless total knee replacement (TKR) is at the present date a controversial topic. Aim of the study was to compare the effect on tibial periprosthetic bone mineral density (BMD) between different implant materials and designs. During the two-year period between January 2005 and December 2006, we analysed data of 45 patients who underwent consecutively cementless TKR (49 implants) at our Institution for primary osteoarthritis. Data was divided in 2 groups: A) 26 implants with tantalium tibial component (Zimmer NexGen Trabecular Metal. TM. Monoblock); B) 23 implants with porous titanium tibial component (Lima MultiGen. TM. ). Data was comparable per sex, age, BMI, post-op alignment, post-op KSS > 75, absence of major post-op complications. Standard AP x-rays were taken 4 months post-op and 8 years post-op. In order to quantify the reduction of BDM, we determined using ImageJ (an open source software) the Mean Grey Value (MGV) of a specific area on the 4 months- and 8 yrs-postop AP x-rays. Group A and Group B had an average MGV variation of, respectively, 11.79% and 10.51%; there was no statistically significant difference between the two groups. Reduction of BMD in a TKR is known to be a biomechanical response to load and it is conditioned by the alignment of the components and their design. Our study shows that the different materials (porous titanium vs. tantalium), in relation to the different implant design, have a similar effect on the surrounding bone. The overall results show a valid osseointegration in both group of patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_13 | Pages 19 - 19
1 Jun 2016
Nataraj A Harikrishna M Puduval M Sridhar M
Full Access

Vitamin D is vital for bone health because it assists in the absorption and utilisation of calcium. Vitamin D deficiency may predispose individuals to developing osteoporosis and subsequent osteoporotic fracture. There are various studies in elderly females with hip fractures correlating the low bone mineral density (BMD) with vitamin D levels. But very few studies have evaluated the influence on elderly males. Therefore this study was conducted. All male patients aged more than 50 years presenting to orthopaedic department, in JIPMER, Puducherry, with either fracture neck of femur or intertrochanteric fracture were included. Serum vitamin D level was assessed in them and BMD of both the hips was evaluated by DEXA scan. The vitamin D levels, T-scores, Z-scores were then analysed and correlated. Of the total 41 patients evaluated 21 (51%) had fracture neck of the femur and 20 (49%) patients had intertrochanteric fractures. We found that 11 (26.8%) patients had osteoporosis, 17 (41.5%) had osteopenia, and 13 (31.7%) had normal values. The mean value of total T-scores on fracture side was −1.55 and on no fracture side was −1.88. Among them 9 (22%) patients had vitamin D level <20 ng /mL, 15 (36%) had levels between 20ng–30ng/mL and 17 (41%) had >30ng/mL. Total T-score and Z-score on fracture side and no fracture side showed no correlation with vitamin D (p value >0.05) in these patients. We found significant osteoporosis in both neck and trochanteric regions on both fracture and no fracture sides, yet we had some patients with trochanteric fracture and some with neck fracture on only one side. In view of this other factors like mode of injury, velocity of injury, muscle wasting might have contributed significantly to the type of fracture and side involved. The BMD was found to be lower in patients with neck of femur fracture compared to intertrochanteric fracture, but no correlation was found between vitamin D and BMD scores at neck and trochanteric region. From this study it appears that there is no direct relationship between the vitamin D level and BMD in elderly males with hip fractures. It may emphasise that in male patients with hip fractures vitamin D may not have critical role in development of osteoporosis. The treatment of such patients with vitamin D supplements to prevent hip fractures is still debatable. However further studies in very large groups and controls may bring more light on this subject


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 49 - 49
1 May 2016
Inaba Y Kobayashi N Oba M Ike H Tezuka T Kubota S Saito T
Full Access

Introduction. Resorptive bone remodeling secondary to stress shielding has been a concern associated with cementless total hip arthroplasty (THA). At present, various types of cementless implants are commercially available. The difference in femoral stem design may affect the degree of postoperative stress shielding. In the present study, we aimed to compare the difference in bone mineral density (BMD) change postoperatively in femurs after the use of 1 of the 3 types of cementless stems. Methods. Ninety hips of 90 patients who underwent primary cementless THA for the treatment of osteoarthritis were included in this study. A fit-and-fill type stem was used for 28 hips, a tapered-rectangular Zweymüller type stem was used for 32 hips, and a tapered-wedge type stem was used for 30 hips. The male/female ratio of the patients was 7/21 in the fit-and-fill type stem group, 6/26 in the tapered-rectangular Zweymüller type stem group, and 6/24 in the tapered-wedge type stem group. The mean age at surgery was 59.9 (39–80) in the fit-and-fill type stem group, 61.7 (48–84) in the tapered-rectangular Zweymüller type stem group and 59.6 (33–89) in the tapered-wedge type stem group. To assess BMD change after THA, we obtained dual-energy X-ray absorptiometry scans preoperatively and at 6, 12, 24, and 36 months postoperatively. Results. There were no differences in demographic data, such as gender, age at surgery, and body mass index, among the 3 groups (Table1). In terms of BMD change after THA, no differences were observed in Gruen zones 1–5 among the 3 groups during the 3-year follow-up. The BMD in Gruen zone 6 was maintained in the tapered-wedge type stem group, but decreased by 5% in the fit-and-fill type stem group and by 20% in the tapered-rectangular Zweymüller type stem group (p < 0.01). The BMD loss in Gruen zone 7 was observed in all stem types; however, the BMD loss at 36 months in the tapered-wedge type stem group (−15%) was significantly less than that of the other 2 groups (the fit-and-fill type stem group: −29%; the tapered-rectangular Zweymüller type stem group: −30%; p < 0.001 for both groups) (Figure). Discussion and Conclusion. A difference in postoperative BMD loss was observed among the 3 stem designs. This may be a result of the different fixation concept associated with each stem design. In the present study, we compared the postoperative BMD change after THA among a fit-and-fill type stem, a tapered-rectangular Zweymüller type stem, and a tapered-wedge type stem. BMD in the medial-proximal femur was maintained 3 years after THA in the group with the tapered-wedge type stem, which is fixed in a more proximal part of the femur compared to the other stems


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 26 - 26
1 May 2016
Mauck J Kebbach M Schulze C Bader R Kluess D
Full Access

Introduction. The influence of the bone mineral density (BMD) on the mechanical behavior of bones can be examined using computer tomography (CT) data and finite element (FE) simulations, because the BMD correlates with the Hounsfield scale (HU) of the CT data. Therefor the material mapping strategy, which is required to assign the HU values to the FE mesh, is of crucial importance. In this study a nodal mapping strategy was analyzed concerning its sensitivity towards FE mesh parameters and an averaging of HU values from the area around the respective nodes. Method. The FE simulation is based on CT data of a human proximal femur. Once the bone shape was reconstructed, the resulting model was meshed with quadratic tetrahedral elements in ABAQUS/CAE and all nodes were assigned an HU value from the CT data by using the respective node coordinates. In this process, the mesh density, the threshold, which could be used to exclude connective tissue and fat from the material mapping process, the considered volume around the nodes and the method of averaging were varied. The material assignment was realized by an HU value dependent, linear elastic material definition. The femur model was clamped at the level of the isthmus and a displacement of 0.5 mm was applied at the femoral head. The evaluation was based on the resulting reaction forces. Results. The sensitivity analysis demonstrated, that threshold and mesh density mainly influenced the reaction force [Fig. 1]. If a threshold was applied, the reaction force increased by about 20 % in average. A threefold increase of the mesh density led to an average gain of the results of about 24 %. For a specific mesh density the curve progressions of the respective results intersected, i.e. an alteration of the considered volume or the method of averaging barely affected the reaction force [Fig. 2, Fig. 3]. Apart from this intersection, the comparison of the small and the large average volume led to a deviation of up to 11 %. On the other hand, the examination of different methods of averaging revealed only a maximum deviation of 4 % between “mean” and “median”. Discussion. The present study indicates, that the material mapping strategy is an influential part of the modeling process, which should be validated to avoid misjudgments of the load situation. Accordingly, the use of a threshold to exclude non-bone tissue could be a helpful tool. But with the exclusion of lower HU values, the load-bearing structure gains stiffness and the reaction force in the femur rises. A finer mesh leads to a higher resolution of the bone structure and, therefore, to a higher accuracy of the results. The “equilibrium” between the different models at the intersection is caused by a more homogeneous distribution of the material property which is increased by a larger considered volume and the method “mean”


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 81 - 81
1 Dec 2022
Straatman L Walton D Lalone E
Full Access

Pain and disability following wrist trauma are highly prevalent, however the mechanisms underlying painare highly unknown. Recent studies in the knee have demonstrated that altered joint contact may induce changes to the subchondral bone density and associated pain following trauma, due to the vascularity of the subchondral bone. In order to examine these changes, a depth-specific imaging technique using quantitative computed tomography (QCT) has been used. We've demonstrated the utility of QCT in measuring vBMD according to static jointcontact and found differences invBMD between healthy and previously injured wrists. However, analyzing a static joint in a neutral position is not necessarily indicative of higher or lower vBMD. Therefore, the purposeof this study is to explore the relationship between subchondral vBMDand kinematic joint contact using the same imaging technique.

To demonstrate the relationship between kinematic joint contact and subchondral vBMDusing QCT, we analyzed the wrists of n = 10 participants (n = 5 healthy and n = 5 with previous wrist trauma). Participantsunderwent 4DCT scans while performing flexion to extension to estimate radiocarpal (specifically the radiolunate (RL) and radioscaphoid (RS)) joint contact area (JCa) between the articulating surfaces. The participantsalso underwent a static CT scan accompanied by a calibration phantom with known material densities that was used to estimate subchondral vBMDof the distal radius. Joint contact is measured by calculatinginter-bone distances (mm2) using a previously validated algorithm. Subchondral vBMD is presented using mean vBMD (mg/K2HPO4) at three normalized depths from the subchondral surface (0 to 2.5, 2.5 to 5 and 5 to 7.5 mm) of the distal radius.

The participants in the healthy cohort demonstrated a larger JCa in the RS joint during both extension and flexion, while the trauma cohort demonstrated a larger JCa in the RL during extension and flexion. With regards to vBMD, the healthy cohort demonstrated a higher vBMD for all three normalized depths from the subchondral surface when compared to the trauma cohort.

Results from our preliminary analysis demonstrate that in the RL joint specifically, a larger JCa throughout flexion and extension was associated with an overall lower vBMD across all three normalized layers. Potential reasoning behind this association could be that following wrist trauma, altered joint contact mechanics due to pathological changes (for example, musculoskeletal trauma), has led to overloading in the RL region. The overloading on this specific region may have led to a decrease in the underlying vBMD when compared to a healthy wrist. However, we are unable to conclude if this is a momentary decrease in vBMD that could be associated with the acute healing phase following trauma given that our analysis is cross-sectional. Therefore, future work should aim to analyze kinematic JCa and vBMD longitudinally to better understand how changes in kinematic JCa over time, and how the healing process following wrist trauma, impacts the underlying subchondral bone in the acute and longitudinal phases of recovery.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 50 - 50
1 Nov 2022
Nayak M Rambani R
Full Access

Abstract. Background. Although tantalum is a well recognised implant material used for revision arthroplasty, little is known regarding the use of the same in primary total hip arthroplasty. Methods. A literature search was performed to find all relevant clinical studies until March 2020, which then underwent a further selection criteria. The inclusion criteria was set as follows: Reporting on human patients undergoing primary total hip arthroplasty; Direct comparison between tantalum acetabular cups with conventional acetabular cups. for use in primary total hip arthroplasty; Radiological evaluation (cup migration, osteointegration); Clinical (functional scores, need for subsequent revision, patient-reported outcomes; Post-operative complications; Reporting findings in the English Language. After a thorough search a total of six studies were included in the review. The primary outcome. measures were clinical outcomes, implant migration, change in bone mineral density and rate of revision and infection. Results. Tantalum was found superior to titanium with regards to fewer radiolucencies, survivorship, osteointegration, decreased osteolysis and mechanical loosening. No significant difference in radioisometric analysis, bone mineral density or Harris Hip Score was found. Revision and infection rates were found to be significantly lower in tantalum group at 10 years from pooled data of national joint registry. Conclusion. The use of tantalum can be reserved for cases of high risk of failure or mechanical loosening, where failure of a contralateral joint occurred as it carries lower risk of failure and infection. Further studies with longer follow-up would be useful in drawing further conclusions


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 81 - 81
1 Jul 2020
Wang F Sun Y Ke H
Full Access

Osteoporosis accounts for a leading cause of degenerative skeletal disease in the elderly. Osteoblast dysfunction is a prominent feature of age-induced bone loss. While microRNAs regulate osteogenic cell behavior and bone mineral acquisition, however, their function to osteoblast senescence during age-mediated osteoporosis remains elusive. This study aims to utilize osteoblast-specific microRNA-29a (miR-29a) transgenic mice to characterize its role in bone cell aging and bone mass. Young (3 months old) and aged (9 months old) transgenic mice overexpressing miR-29a (miR-29aTg) driven by osteocalcin promoter and wild-type (WT) mice were bred for study. Bone mineral density, trabecular morphometry, and biomechanical properties were quantified using μCT imaging, material testing system and histomorphometry. Aged osteoblasts and senescence markers were probed using immunofluorescence, flow cytometry for apoptotic maker annexin V, and RT-PCR. Significantly decreased bone mineral density, sparse trabecular morphometry (trabecular volume, thickness, and number), and poor biomechanical properties (maximum force and breaking force) along with low miR-29a expression occurred in aged WT mice. Aging significantly upregulated the expression of senescence markers p16INK4a, p21Waf/Cip1, and p53 in osteoporotic bone in WT mice. Of note, the severity of bone mass and biomechanical strength loss, as well as bone cell senescence, was remarkably compromised in aged miR-29aTg mice. In vitro, knocking down miR-29a accelerated senescent (β-galactosidase activity and senescence markers) and apoptotic reactions (capsas3 activation and TUNEL staining), but reduced mineralized matrix accumulation in osteoblasts. Forced miR-29a expression attenuated inflammatory cytokine-induced aging process and retained osteogenic differentiation capacity. Mechanistically, miR-29a dragged osteoblast senescence through targeting 3′-untranslated region of anti-aging regulator FoxO3 to upregulate that of expression as evident from luciferase activity assessment. Low miR-29a signaling speeds up aging-induced osteoblast dysfunction and osteoporosis development. Gain of miR-29a function interrupts osteoblast senescence and shields bone tissue from age-induced osteoporosis. The robust analysis sheds light to the protective actions of miR-29a to skeletal metabolism and conveys a perspective of miR-29a signaling enhancement beneficial for aged skeletons


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 72 - 72
7 Nov 2023
Khumalo M
Full Access

Low-energy fractures complications are a major public health issue that make osteoporosis even worse. In sub-Saharan Africa, the prevalence of osteoporosis varies from 18.2% to 65.8%. There was no change in bone mineral density between HIV-infected and non-HIV-infected women in Sub-Saharan Africa, where HIV is widespread. Other investigations that demonstrated that HIV-infected people had poor BMD both before and after starting anti-retroviral treatment did not consistently show a low BMD finding. Inflammation-mediated bone remodelling has been associated with low BMD in HIV-infected patients. Antiretroviral Therapy has been demonstrated to exacerbate bone loss in addition to the pre-existing intrinsic risk of developing osteoporosis. Question: Is there loss of bone in HIV-infected patients before initiating ART?. The patients who were HIV-positive and enrolled in the ADVANCE research were retrospectively reviewed on a desk. All of the 1053 individuals in the ADVANCE research had a DXA scan performed to evaluate BMD as part of the initial screening and recruitment approach. The ADVANCE research enrolled HIV-positive people and randomly assigned them to three ART arms. A total of 400 patients were reviewed. Of these 400 records reviewed, 62.3% were female. 80% of the participants were younger than 40 years old, and 3% were older than 50 years. 82% were virally suppressed with less than 50 viral copies. The prevalence of osteopenia was 25.5% and osteoporosis was 2.8%, observed in predominantly African female participants aged between 30 and 39 years. The findings of this study confirm that there is pre-existing bone loss among HIV-infected ART naïve individuals. Approximately 28.3% in our study had clinically confirmed evidence of bone loss and of these, 2.8% of the entire cohort had osteoporosis. Bone loss was most prevalent in black females who are virologically suppressed


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 22 - 22
1 Nov 2022
Tolat A Salam NA Gavai P Desai V
Full Access

Abstract. Introduction. Vitamin D deficiency in the UK is well documented − 30–40% of the population. It is an essential component of calcium metabolism and adequate levels are important for bone healing. Studies have demonstrated an overall prevalence of vitamin D deficiency/insufficiency at 77% in trauma patients aged >18, deficiency alone was 39%. Adequate vitamin D levels have a positive effect on bone mineral density and callus formation at fracture sites. Methods. We conducted a retrospective consecutive case series of all patients aged 0–50 undergoing surgical management for any fracture in October 2021 to March 2022. We assessed if vitamin D levels were checked and if patients were prescribed replacement as per local guidelines. Results. A total of 131 patients were identified, (mean 29 years; 83 male and 48 female). Most cases were upper limb fractures (n=78, 60%), as opposed to lower limb (n=53, 40%). Only 20 (15%) had their levels checked, of which 13 (65%) were insufficient/deficient (10 insufficiency, 2 deficiency, 1 severe deficiency). Of these 13 patients, only 3 (23%) were prescribed replacement therapy. Conclusions. Only a small proportion of patients had their levels checked, however the majority were insufficient/deficient. The prevalence in our study is consistent with larger epidemiology studies, which reflect a higher rate of deficiency in fracture patients compared to the general population. Thus, we propose that all patients in this age group should undergo a vitamin d level check upon time of clerking and this should be accurately treated as per trust guidance


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 152 - 152
1 Sep 2012
Rizal E Watson M Pitto R Cornish J
Full Access

Six week old male Sprague-Dawley rats were administered intravenous clozapine, quetiapine, haloperidol or vehicle once daily for a period of 42 days with access to only high fat diet and their weight was monitored regularly. At the end of the study the rats were killed and the tibiae excised and bone mineral density (BMD) measured with dual X-ray absorptiometry and bone architecture assessed with micro-computed tomography (micro-CT) and associated software. Results were subjected to one-way ANOVA and post hoc Dunnetts multiple comparison test. All treatment groups were compared to control. There were no significant differences in body weight between the different groups at completion of the study. Clozapine treated animals alone showed a significant reduction in bone mineral density (p<0.05) however no differences were seen with haloperidol and quetiapine. Both haloperidol and quetiapine, but not clozapine, treatment showed a significant reduction in the bone to tissue volume ratio (BV/TV) by approximately 23% (p<0.05) and an increase in trabecular number (TbN) by approximately 21% (p<0.05). Trabecular bone architecture parameters for haloperidol and quetiapine, but not clozapine, showed more rod like and disconnected structure as reflected in the increases in structure model index (SMI) of around 15% (p<0.05) and trabecular pattern factor (TbPf) by 22% (p<0.05). This data demonstrates that in rats receiving a high fat diet, haloperidol and quetiapine have an adverse effect on bone micro-architecture without significant change in whole body bone mineral density. Clozapine did not affect bony architecture in a significant manner as reported in our earlier study, though bone mineral density was reduced. Reasons for the different effect of clozapine in this study are still uncertain but may be related to the significant weight loss seen at the end point of the previous study. Causes for osteoporosis and increased fracture risk in schizophrenia may include smoking history, malnutrition, limited sun exposure and compliance. Long term administration of both typical and atypical anti-psychotics may have a negative effect on bone and is a further factor that can influence this risk. An awareness of this relationship is useful in the orthopaedic management of schizophrenic patients