Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_12 | Pages 5 - 5
1 Jun 2016
Nicoll K Downie S Hilley A Breusch S Clift B
Full Access

British national guidelines recommend agents which antagonise factor Xa or warfarin as prophylaxis of venous thromboembolism (VTE) in lower limb arthroplasty. However, they discourage the use of aspirin prophylaxis. We conducted a prospective, multi-centre audit between two national centres, Ninewells Hospital in Dundee and the Royal Infirmary in Edinburgh to compare bleeding and VTE risk. Only Edinburgh routinely uses aspirin as VTE prophylaxis. The study comprises a number of cycles from 2013 to 2015. Consecutive groups of patients were identified prospectively using elective theatre data and information extracted from their case-notes on type of VTE prophylaxis, VTE occurrence, wound complications and length of hospital stay for a period of nine weeks post-operatively. 262 Edinburgh patients and 92 Dundee patients were included. Most Edinburgh patients were prescribed aspirin in hospital and on discharge (188/262, 71.8%), in line with local protocol. In Dundee, dalteparin was most commonly prescribed in hospital (68/92, 73.9%) and rivaroxaban on discharge (57/92, 62.0%). The Edinburgh group had a 1.5% incidence of pulmonary embolus (PE) and a 1% rate of deep venous thrombosis (DVT), 2% had problems with wound haematoma and one patient (0.4%) required a transfusion; no wound washouts were required. In Dundee there was 0% PE, 2% DVT, 5% had problems with haematoma, 3% required transfusion and 2% required washout. There was no difference in length of hospital stay, with a mode of 4 days for both centres. Non-fatal PE was prevented in Dundee patients but possibly at the cost of greater incidence of wound complications


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1053 - 1059
1 Aug 2006
Foss NB Kehlet H

Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss. We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 14 - 14
1 Feb 2014
Allen D Panousis K
Full Access

Patients with a history of venous thromboembolism (VTE) are considered at very high risk for recurrence after lower limb arthroplasty (LLA). However, the chance of a new VTE episode after LLA has not been yet quantified. The aim of this study was to define the incidence of VTE recurrence following knee and hip arthroplasty. The case notes for all LLA patients treated at our hospital from 2009 to 2011 were reviewed. There were 5946 primary and revision LLA operations in total; 118 of these interventions were performed in 106 patients with a history of VTE. This group included 69 females and 37 males with a mean age of 69.9. Routine thromboprophylaxis for LLA patients included mechanical (footpumps & TED stockings) plus chemical prophylaxis using Aspirin 150 mg for 6 weeks. Patients with a VTE history had the same mechanical prophylaxis but received warfarin for 3 months. There were no fatal VTEs within 90 days of surgery. There were 5 episodes (4.2%) of VTE recurrence and specifically 4 PE and one DVT (femoral vein) at 4 months after the operation. Two of the PEs were asymptomatic, diagnosed on CTPA scans being requested for low O2 saturations on routine monitoring. In the group of patients without a VTE history there were 35 VTE episodes (0.6%), indicating a significantly lower rate of VTE (p=0.001) in comparison with the study group. Patients with a history of VTE had a 4.2% chance of having a further VTE. This is seven times greater than the rate among all other patients despite using more aggressive chemoprophylaxis


Bone & Joint Research
Vol. 5, Issue 10 | Pages 512 - 519
1 Oct 2016
Mills L Tsang J Hopper G Keenan G Simpson AHRW

Objectives

A successful outcome following treatment of nonunion requires the correct identification of all of the underlying cause(s) and addressing them appropriately. The aim of this study was to assess the distribution and frequency of causative factors in a consecutive cohort of nonunion patients in order to optimise the management strategy for individual patients presenting with nonunion.

Methods

Causes of the nonunion were divided into four categories: mechanical; infection; dead bone with a gap; and host. Prospective and retrospective data of 100 consecutive patients who had undergone surgery for long bone fracture nonunion were analysed.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1073 - 1078
1 Aug 2008
Little NJ Verma V Fernando C Elliott DS Khaleel A

We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study.

Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality.

We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 vs 40.4 minutes, p < 0.001; and 40.3 vs 54 minutes, p < 0.001, respectively). There was an increased mean blood loss within the DHS group versus the Holland nail group (160 ml vs 78 ml, respectively, p < 0.001). The mean time to mobilisation with a frame was shorter in the Holland nail group (DHS 4.3 days, Holland nail 3.6 days, p = 0.012). More patients needed a post-operative blood transfusion in the DHS group (23 vs seven, p = 0.003) and the mean radiation time was shorter in this group (DHS 0.9 minutes vs Holland nail 1.56 minutes, p < 0.001). The screw of the DHS cut out in two patients, one of whom underwent revision to a Holland nail. There were no revisions in the Holland nail group. All fractures in both groups were united when followed up after one year.

We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1117 - 1122
1 Aug 2005
Fuchs S Heyse T Rudofsky G Gosheger G Chylarecki C

There is a high risk of venous thromboembolism when patients are immobilised following trauma. The combination of low-molecular-weight heparin (LMWH) with graduated compression stockings is frequently used in orthopaedic surgery to try and prevent this, but a relatively high incidence of thromboembolic events remains. Mechanical devices which perform continuous passive motion imitate contractions and increase the volume and velocity of venous flow.

In this study 227 trauma patients were randomised to receive either treatment with the Arthroflow device and LMWH or only with the latter. The Arthroflow device passively extends and plantarflexes the feet. Patients were assessed initially by venous-occlusion plethysmography, compression ultrasonography and continuous wave Doppler, which were repeated weekly without knowledge of the category of randomisation. Those who showed evidence of deep-vein thrombosis underwent venography for confirmation. The incidence of deep-vein thrombosis was 25% in the LMWH group compared with 3.6% in those who had additional treatment with the Arthroflow device (p < 0.001). There were no substantial complications or problems of non-compliance with the Arthroflow device. Logistic regression analysis of the risk factors of deep-vein thrombosis showed high odds ratios for operation (4.1), immobilisation (4.3), older than 40 years of age (2.8) and obesity (2.2).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1340 - 1343
1 Oct 2007
Patil S Gandhi J Curzon I Hui ACW

Stable fractures of the ankle can be successfully treated non-operatively by a below-knee plaster cast. In some centres, patients with this injury are routinely administered low-molecular-weight heparin, to reduce the risk of deep-vein thrombosis (DVT). We have assessed the incidence of DVT in 100 patients in the absence of any thromboprophylaxis. A colour Doppler duplex ultrasound scan was done at the time of the removal of the cast.

Five patients did develop DVT, though none had clinical signs suggestive of it. One case involved the femoral and another the popliteal vein. No patient developed pulmonary embolism. As the incidence of DVT after ankle fractures is low, we do not recommend routine thromboprophylaxis.