Advertisement for orthosearch.org.uk
Results 1 - 20 of 126
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims. The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs. Methods. The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%). Results. For detection and classification, the algorithm was trained on 1,709 radiographs (n = 803), tested on 567 radiographs (n = 244), and subsequently externally validated on 535 radiographs (n = 227). For characterization, healthy shoulders and glenohumeral dislocation were excluded. The overall accuracy for fracture detection was 94% (area under the receiver operating characteristic curve (AUC) = 0.98) and for classification 78% (AUC 0.68 to 0.93). Accuracy to detect greater tuberosity fracture displacement ≥ 1 cm was 35.0% (AUC 0.57). The CNN did not recognize NSAs ≤ 100° (AUC 0.42), nor fractures with ≥ 75% shaft translation (AUC 0.51 to 0.53), or with ≥ 15% articular involvement (AUC 0.48 to 0.49). For all objectives, the model’s performance on the external dataset showed similar accuracy levels. Conclusion. CNNs proficiently rule out proximal humerus fractures on plain radiographs. Despite rigorous training methodology based on CT imaging with multi-rater consensus to serve as the reference standard, artificial intelligence-driven classification is insufficient for clinical implementation. The CNN exhibited poor diagnostic ability to detect greater tuberosity displacement ≥ 1 cm and failed to identify NSAs ≤ 100°, shaft translations, or articular fractures. Cite this article: Bone Joint J 2024;106-B(11):1348–1360


Bone & Joint Open
Vol. 2, Issue 3 | Pages 150 - 163
1 Mar 2021
Flett L Adamson J Barron E Brealey S Corbacho B Costa ML Gedney G Giotakis N Hewitt C Hugill-Jones J Hukins D Keding A McDaid C Mitchell A Northgraves M O'Carroll G Parker A Scantlebury A Stobbart L Torgerson D Turner E Welch C Sharma H

Aims. A pilon fracture is a severe ankle joint injury caused by high-energy trauma, typically affecting men of working age. Although relatively uncommon (5% to 7% of all tibial fractures), this injury causes among the worst functional and health outcomes of any skeletal injury, with a high risk of serious complications and long-term disability, and with devastating consequences on patients’ quality of life and financial prospects. Robust evidence to guide treatment is currently lacking. This study aims to evaluate the clinical and cost-effectiveness of two surgical interventions that are most commonly used to treat pilon fractures. Methods. A randomized controlled trial (RCT) of 334 adult patients diagnosed with a closed type C pilon fracture will be conducted. Internal locking plate fixation will be compared with external frame fixation. The primary outcome and endpoint will be the Disability Rating Index (a patient self-reported assessment of physical disability) at 12 months. This will also be measured at baseline, three, six, and 24 months after randomization. Secondary outcomes include the Olerud and Molander Ankle Score (OMAS), the five-level EuroQol five-dimenison score (EQ-5D-5L), complications (including bone healing), resource use, work impact, and patient treatment preference. The acceptability of the treatments and study design to patients and health care professionals will be explored through qualitative methods. Discussion. The two treatments being compared are the most commonly used for this injury, however there is uncertainty over which is most clinically and cost-effective. The Articular Pilon Fracture (ACTIVE) Trial is a sufficiently powered and rigorously designed study to inform clinical decisions for the treatment of adults with this injury. Cite this article: Bone Jt Open 2021;2(3):150–163


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 150 - 150
1 Jan 2013
Bhatt H Halder S
Full Access

Aim. Treatment for distal third shaft fractures of humerus is very challenging especially if its comminuted and bone is osteopenic. They are commonly treated with plating. Plating has complications of iatrogenic radial nerve palsy. We report our case series of distal third fractures of humerus treated with retrograde Halder Humeral Nail. Materials and methods. Since 1994 to 2010 we have 576 fractures of humerus treated with retrograde Halder Humeral nail. Of these 45 were distal third extra articular fractures of humerus. Average age of patients at the time of surgery was 30.4 years (Range 15–82 years, Median 33 years). Of 45 patients 26 were females and 19 males.3 out of 45 had non union at the time of presentation. The nail was locked distally with one or two screws and proximally with a screw and tripwire. The entry point of the nail was roof of olecranon fossa (contrary to standard retrograde nails where it is an inch above olecranon fossa) This design of nail allows it be used for even very distal fractures. All patients were followed till clinical and radiological signs of union. 1 patient was lost to follow up. Results. Average time to fracture healing was 13.9 weeks (Range 9–36 weeks). There were 2 cases of non union, one healed at 9 months with 2. nd. surgery. The other non union was asymptomatic and did not agree for further surgery. There was one reported case of infection.7 patients had nail removal electively on request. All the patients achieved full range of elbow and shoulder movement. No reported cases of iatrogenic radial nerve palsy. Conclusion. Our results of distal third fractures of humerus treated with retrograde Halder Humeral Nail are excellent. It avoids big exposure as needed in plating and complication of iatrogenic radial nerve palsy


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 44 - 44
1 Nov 2022
Khadabadi N Murrell J Selzer G Moores T Hossain F
Full Access

Abstract. Introduction. We aimed to compare the outcomes of elderly patients with periarticular distal femur or supracondylar periprosthetic fractures treated with either open reduction internal fixation or distal femoral replacement. Methods. A retrospective review of patients over 65 years with AO Type B and C fractures of the distal femur or Su type I and II periprosthetic fractures treated with either a DFR or ORIF was undertaken. Outcomes including Length of Stay, PROMs (Oxford Knee Score and EQ 5D), infection, union, mortality, complication and reoperation rates were assessed. Data on confounding variables were also collected for multivariate analysis. Patients below 65 years and extra articular fractures were excluded. Results. 23 patients (11 in DFR group and 12 in ORIF group) fulfilled inclusion criteria and were included in the analysis. There was no difference between the DFR and ORIF groups with respect to SDI, demographic variables, ASA grade, FCI, preoperative Hb and renal function. There was no difference in 30 day mortality, reoperation rates, 30 day readmission rates and LOS between the two groups. Mean follow up was 12.7 and 15.9 months respectively in the DFR and ORIF groups. At final follow up after accounting for all confounding variables on multivariate analysis, functional outcomes using OKS (adjusted mean: 29.5 vs 15.8) and Health related Quality of Life outcomes using EQ 5D (adjusted mean: 0.453 vs −0.07) were significantly better in the DFR group. Conclusion. DFR for periarticular and periprosthetic distal femoral fractures in the elderly are associated with better patient reported outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 82 - 82
10 Feb 2023
Tetsworth K Green N Barlow G Stubican M Vindenes F Glatt V
Full Access

Tibial pilon fractures are typically the result of high-energy axial loads, with complex intra- articular fractures that are often difficult to reconstruct anatomically. Only nine simultaneous pilon and talus fractures have been published previously, but we hypothesised the chondral surface of the dome is affected more frequently. Data was acquired prospectively from 154 acute distal tibial pilon fractures (AO/OTA 43B/C) in adults. Radiographs, photographs, and intra-operative drawings of each case were utilised to document the presence of any macroscopic injuries of the talus. Detailed 1x1mm maps were created of the injuries in each case and transposed onto a statistical shape model of a talus; this enables the cumulative data to be analysed in Excel. Data was analysed using a Chi-squared test. From 154 cases, 104 were considered at risk and their talar domes were inspected; of these, macroscopic injuries were identified in 55 (52.4%). The prevalence of talar dome injury was greater with B-type fractures (53.5%) than C-type fractures (31.5%) (ρ = .01). Injuries were more common in men than women and presented with different distribution of injuries (ρ = .032). A significant difference in the distribution of injuries was also identified when comparing falls and motor vehicle accidents (ρ = .007). Concomitant injuries to the articular surface of the dome of the talus are relatively common, and this perhaps explains the discordance between the post-operative appearance following internal fixation and the clinical outcomes observed. These injuries were focused on the lateral third of the dome in men and MVAs, whereas women and fall mechanism were more evenly distributed. Surgeons who operatively manage high-energy pilon fractures should consider routine inspection of the talar dome to assess the possibility of associated macroscopic osteochondral injuries


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 29 - 29
2 Jan 2024
Bojan A Procter P Karami P Pioletti D
Full Access

The fixation of articular fractures, with many small osteochondral fragments, is a challenging unmet need where a bone adhesive would be a useful adjunct to standard treatments. Whilst there are no such adhesives in current clinical use, preclinical animal models have demonstrated good healing of bone in unloaded models using an adhesive based on phosphoserine modified calcium phosphate cement (PM-CPC). An ex-vivo human bone core model has shown that this adhesive bonds freshly harvested human bone. To confirm this adhesive is capable of supporting loaded osteochondral fragments a porcine model has been developed initially ex-vivo on the path to an in-vivo study. In this model bone cores, harvested from the medial knee condyle, are glued in place with the adhesive. In-vivo adjacent pairs of bone cores would be replaced with adhesive and a control with conventional pin fixation respectively. As osteochondral bone fragments have both bone and cartilage components, this suggested a dual adhesive strategy in which components designed for each tissue type are used. This concept has been explored in an ex-vivo porcine pilot study presented herewith. At the subchondral bone level, the PM-CPC was used. At the cartilage level, a second adhesive, a methacrylated phosphoserine containing hyaluronic acid (MePHa) hydrogel designed specifically for soft tissues was applied. This is a challenging model as both adhesives have to be used simultaneously in a wet field. The pilot showed that once the subchondral component is glued in place, the PM-CPC adhesive intruding into the cartilage gap can be removed before applying the cartilage adhesive. This enabled the MePHa adhesive to be injected between the cut cartilage edges and subsequently light-cured. This two-stage gluing method is demanding and an in-vivo pilot is necessary to perfect and prove the operative technique. Acknowledgements: The human bone core project was partially financed by Innovation Fund of Västra Götaland Region, Sweden. The MePHa hydrogel work was supported by a Swiss National Fund grant # CR23I3_159301


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 7 - 7
10 Jun 2024
Hill D Davis J
Full Access

Introduction. Tibial Pilon fractures are potentially limb threatening, yet standards of care are lacking from BOFAS and the BOA. The mantra of “span, scan, plan” describes staged management with external fixation to allow soft tissue resuscitation, followed by a planning CT-scan. Our aim was to evaluate how Tibial Pilon fractures are acutely managed. Methods. ENFORCE was a multi-centre retrospective observational study of the acute management of partial and complete articular Tibial Pilon fractures over a three-year period. Mechanism, imaging, fracture classification, time to fracture reduction and cast, and soft tissue damage control details were determined. Results. 656 patients (670 fractures) across 27 centres were reported. AO fracture classifications were: partial articular (n=294) and complete articular (n=376). Initial diagnostic imaging mobilities were: plain radiographs (n=602) and CT-scan (n=54), with all but 38 cases having a planning CT-scan. 526 fractures had a cast applied in the Emergency Department (91 before radiological diagnosis), with the times taken to obtain post cast imaging being: mean 2.7 hours, median 2.3 hours, range 28 mins – 14 hours). 35% (102/294) of partial articular and 57% (216/376) of complete articular (length unstable) fractures had an external fixator applied, all of which underwent a planning CT-scan. Definitive management consisted of: open reduction internal fixation (n=495), fine wire frame (n=86), spanning external fixator (n=25), intramedullary nail (n=25), other (n=18). Conclusion. The management of Tibial Pilon fractures is variable, with prolonged delays in obtaining post cast reduction radiographs, and just over half of length unstable complete articular fractures being managed with the gold standard “span, scan, plan” staged soft tissue resuscitation. A BOFAS endorsed BOAST (British Orthopaedic Association Standard for Trauma) for Tibial Pilon fractures is suggested for standardisation of the acute management of these potentially limb threatening injuries, together with setting them apart from more straightforward ankle fractures


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 47 - 47
1 Apr 2022
Myatt D Stringer H Mason L Fischer B
Full Access

Introduction. Diaphyseal tibial fractures account for approximately 1.9% of adult fractures. Several studies demonstrate a high proportion of diaphyseal tibial fractures have ipsilateral occult posterior malleolus fractures, this ranges from 22–92.3%. Materials and Methods. A retrospective review of a prospectively collected database was performed at Liverpool University Hospitals NHS Foundation Trust between 1/1/2013 and 9/11/2020. The inclusion criteria were patients over 16, with a diaphyseal tibial fracture and who underwent a CT. The articular fracture extension was categorised into either posterior malleolar (PM) or other fracture. Results. 764 fractures were analysed, 300 had a CT. There were 127 intra-articular fractures. 83 (65.4%) cases were PM and 44 were other fractures. On univariate analysis for PM fractures, fibular spiral (p=.016) fractures, no fibular fracture(p=.003), lateral direction of the tibial fracture (p=.04), female gender (p=.002), AO 42B1 (p=.033) and an increasing angle of tibial fracture. On multivariate regression analysis a high angle of tibia fracture was significant. Other fracture extensions were associated with no fibular fracture (p=.002), medial direction of tibia fracture (p=.004), female gender (p=.000), and AO 42A1 (p=.004), 42A2 (p=.029), 42B3 (p=.035) and 42C2 (p=.032). On multivariate analysis, the lateral direction of tibia fracture, and AO classification 42A1 and 42A2 were significant. Conclusions. Articular extension happened in 42.3%. A number of factors were associated with the extension, however multivariate analysis did not create a suitable prediction model. Nevertheless, rotational tibia fractures with a high angle of fracture should have further investigation with a CT


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 145 - 145
1 Sep 2012
Lumsdaine W Enninghorst N Balogh Z
Full Access

The universal availability of CT scanners has led to lower thresholds for imaging despite significant financial costs and radiation exposure. We hypothesized that this recent trend increased the use of CT for upper limb articular fractures and led to more frequent operative management. A 5-year retrospective study (01/07/2005–30/06/2010) was performed on all adult patients with upper extremity articular fractures (AO: 1.1, 1.3, 2.1 and 2.3) admitted to a Level-1 Trauma Centre. Patients were identified from the institutions prospectively maintained AO classification database. A total of 1651 patients with 1735 upper extremity articular fractures were identified. 1131 (65%) fractures were operated on. 556 (32%) fractures had CT imaging, 429 (77%) of these had operative management. 289 (17%) patients had multiple injuries and 168 (10%) received a scan of at least 1 other body region. There was a gradual increase in CT use and operative management 1.1, 1.3 and 2.1 fractures. Operation rates for 2.3 fractures unchanged but CT imaging frequency declined. In patients younger than 55 years operative management remained stable at 71% throughout the 5-year period considering all four regions. Overall CT use was stable at 38%, however scan rates for distal radius decreased but for proximal forearm increased. The operative management of patients older than 55 years has increased significantly from 56% in 2005, to 70% in 2010. The most marked increase was observed in proximal humerus fractures. Except for 2.3 fractures, CT rates showed similar but less pronounced increases. There is no increase in CT usage and operative management in younger upper limb articular fracture patients. CT utilization is even decreasing in distal radius fractures. Older patients are less likely to get CT scanned but there is a significant increase in operative management of their upper limb articular fractures


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 284 - 285
1 Jul 2008
COGNET J EHLINGER M MARSAL C KADOSH V GEAHNA A GOUZOU S SIMON P
Full Access

Purpose of the study: Since 2001, we have used arthroscopy systematically to control the treatment of distal radius fractures. We report our three years experience. Material and methods: Arthroscopic control was used for all patients aged less than 65 admitted to our unit for treatment of an articular fracture of the distal radius. The same operator performed all procedures. Fixation methods were: K-wire pinning, locked plating (Synthes) or a combination of these two methods. The arthro-scope had a 2.4 mm optic. Bony lesions were noted according to the Cataign, Fernandez and AO classifications. The DASH, Green and O’Brien, and PWRE scores were noted. Results: Intraoperative arthroscopic control was performed for 61 patients between November 2001 and November 2004. Mean follow-up was 17 months (range 6–36 months). Arthroscopic exploration revealed: scapholunate ligament tears (n=11), lunotriquetral ligament injuries (n=3), pathological perforations of the triangle complex (n=4), damage to the radial cartilage (n=15), and mirror involvement of the carpal cartilage (n=4). An arthroscopic procedure was necessary to treat a bone or ligament lesion in 28 cases. At last follow-up, the DASH score was 19.3 and the PWRE 37.6. Discussion: Arthroscopic evaluation of articular fractures of the distal radius, a routine practice in English-speaking countries, remains a limited practice in France. There is nevertheless a real advantage of using intraoperative arthroscopy. The particular anatomy of the radial surface makes it impossible to achieve proper assessment on the plain x-ray for a quality reduction of the fracture. Recent ligament injuries are rarely detectable on a wrist x-ray. An intra-articular stair-step or an untreated ligament injury can pave the way to short-term development of osteoarthritic degeneration. Intraoperative arthroscopic control is the only way to diagnosi and treat these osteoligamentary lesions observed in patients with an articular fracture of the distal radius. For us, non use of intraoperative arthroscopy constitutes a lost chance for patients with an articular fracture of the distal radius


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 53 - 53
1 May 2012
Mandziak D
Full Access

Purpose. Intra-articular fractures of the distal radius are common injuries. Their pathogenesis involves a complex combination of forces, including ligament tension, bony compression and shearing, leading to injury patterns that challenge the treating surgeon. The contribution of the radiocarpal and radioulnar ligaments to articular fracture location has not previously been described. Computed tomography (CT) scanning is an important method of evaluating intra-articular distal radius fractures, revealing details missed on plain radiographs and influencing treatment plans. Methods. We retrospectively reviewed CT scans of acute intra-articular distal radius fractures performed in one institution from June 2001 to June 2008. Forty- five of 145 scans were deemed unsuitable due to poor quality or presence of internal fixation in the distal radius, leaving 100 fractures for review. Fracture line locations were mapped to a standardised distal radius model, and statistically analysed in their relationship to ligament attachment zones. Results. Distal radius articular fracture lines are significantly less likely to occur in the regions of ligament attachment. Conversely, fracture lines are more likely to occur in the gaps between major ligament attachments. Conclusion. Articular fracture locations in the distal radius are significantly related to radiocarpal and radioulnar ligament attachments. This may aid treating surgeons in understanding the personality of a fracture and the role of ligamentotaxis in fracture reduction


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 15 - 15
1 Nov 2019
Mishra AN Kapoor SK Chawla P Nagpal P
Full Access

Osteogenic augmentation is required in various orthopaedic conditions. Autograft is the gold standard but has limitations of increased morbidity and limited amount. Bone graft substitutes are costly and limited and don't integrate with host bone. Deep freezed allografts are a viable option, though not widely used in India and there are sparse reports in literature. This paper studies early efficacy of deep freezed bone allografts in treatment of fractures requiring bone graft. This is a prospective descriptive study. Strict inclusion and exclusion criteria as per standard guidelines were followed. We have a in-house facility of gamma irradiated deep freezed allografts available in hospital. 20 patients with comminuted fracture, delayed / malunion / nonunion, depressed intra articular fractures were operated during one year and followed up for at least 24 weeks. Sloof's Criteria was used for assessing osteointegration of grafts. Efficacy was authenticated by observing complications like serous discharge from surgical site, infection (superficial/deep), rejection of graft, clinical and radiological integration of graft, maintenance of articular reduction etc. Allografts have not only accepted well but fractures have healed and bone integration is at various stages. Only one patients got infected (5%). The overall success rate in terms of adequate osteointegration is 95 %. 19 out of 20 patients in our study group had either attained or at various stages of osteointegration and healing. We concluded that deep freezed bone allografts is a viable option in patients with fractures requiring bone grafts, thus give satisfactory surgical outcome, with no serious side effects


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 65 - 65
1 Nov 2018
Hoekzema N
Full Access

Advancements in treating distal humerus fractures. We will review and discuss approaches to the elbow to treat different types of fractures. We will discuss the role of soft tissue structures and how they affect elbow function. During this session, we will review the latest techniques for treating the complex articular fractures of the distal humerus to include capitellar and trochlear fractures. Techniques presented will address fixation, reconstruction, and salvaging of complex distal humerus fractures


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 108 - 108
1 Nov 2021
Manfreda F Gregori P Marzano F Caraffa A Donis A
Full Access

Introduction and Objective. Joint malleolar fractures have been estimated around 9% of all fractures. They are characterized by different both early and late complications. Among the latter, arthrofibrosis and early secondary arthrosis represent the two most common ones. Moreover, these two complications could be considered related to each other. Their real cause is still under investigation, even if residual post-operative hematoma and acute post-traumatic synovitis appear to be the most accredited. Supporting this hypothesis, joint debridement and the evacuation of the post-operative hematoma could represent a possible solution. The aim of this prospective study is to evaluate the role of arthroscopic lavage and debridement during internal fixation in order to prevent late joint complications. Materials and Methods. Sixty consecutive patients who reported dislocated articular ankle fractures with surgical indication of open reduction and internal fixation (ORIF) have been included in this study. 27 patients underwent ORIF surgery associated with arthroscopic washout and debridement, while 33 patients, representing the control group, underwent just internal reduction and osteosynthesis. Patients with pure dislocations, non-articular fractures, polytrauma, previous local trauma, metabolic and connective pathologies were excluded. Follow-up was performed at 40 days (T1), 3 (T2) and 6 months (T3) after trauma for all patients. If necessary, some have been re-evaluated 12 months after the trauma. Efficacy of the treatment was evaluated through the VAS scale, Maryland scale, search for local complications such as dehiscence or infections, and finally radiographic evaluation. T-Student was estimated in order to individuate statistical significance. Results. VAS scale showed higher values for the case group than the control group with mean values of 2.7 and 4.2 at T1 and 2.1 and 3.8 at T2, respectively. At 6 months follow-up, the VAS values resulted similar with 2.6 for the case group and 2.8 for the control group. The same projections were found for the Maryland scale, with values of 61.5 and 40.7 at T1, 80.8 and 68.0 at T2 and 87.8 and 85.0 with no significant differences at T3 respectively. No significant differences were detected for complications or radiographic evaluation. Conclusions. Our study has shown significance differences in terms of pain and time for recovery only in the very short term follow up. Although our study, due to the specific limits, cannot be considered diriment, on the basis of the data, we could hypothesize that the aforementioned hypothesis may remain valid for the non-acute hematoma or that the cause of the arthrofibrosis should be sought somewhere else. However, evidence is low, and further research is needed


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 124 - 124
1 May 2011
Bel J Herzberg G
Full Access

Aims: Internal Fixation of complex calcaneal articular fractures is debated: a perfect and upheld reduction is challenging. Could locked screws calcaneal plates drive back the limits of Internal Fixation instead of initial arthrodesis, involve a faster rehabilitation and improve the results?. Methods: Between 2004 and 2008, 32 patients (26 men, 6 women), sustained 35 complex calcaneal articular fractures. Age: 41.46 [17–71] ±15.99 years. Pre operative TDM: ≥3 displaced articular fragments (Sanders III: 22 and IV: 13). ORIF by the same surgeon, between D4 and D7, through a lateral approach and using an AO LCP. ®. locked screws calcaneal plate. Intra operative X-ray controls, postoperative TDM. Articular re-education at D30. Complete weight bearing at D90. Follow-up until 60 months (X-ray and Kitaoka score). Results: Obtained and upheld anatomical articular reduction -Boehler’s angle, talo and cubo-calcaneal congruence-: (35/35). Bone healing: 8 weeks (21/35) and 12 weeks (14/35). Delayed wound healing -smokers-: (6/35). Anatomical articular upholding after 12 months: (35/35). Plate ruptures at D90 without displacement: (2/35). Walking without crutch after D90: (35/35). Mean follow up: 40 months. Conclusion: Locked screws calcaneal plate used for the fixation of complex articular calcaneal fractures showed no displacement in the primary and secondary healing time. These facts limit the place of initial arthrodesis and streamline the initial recovery process. This may be beneficial for clinical use and the long term follow-up


Bone & Joint 360
Vol. 12, Issue 1 | Pages 23 - 25
1 Feb 2023

The February 2023 Foot & Ankle Roundup360 looks at: Joint inflammatory response in ankle and pilon fractures; Tibiotalocalcaneal fusion with a custom cage; Topical application of tranexamic acid can reduce blood loss in calcaneal fractures; Risk factors for failure of total ankle arthroplasty; Pain catastrophizing: the same as pain forecasting?.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 153 - 153
1 Sep 2012
Faber KJ Pike JM Grewal R Athwal GS King GJ
Full Access

Purpose. Limited information is available regarding the functional outcomes of radial head fractures managed with open reduction and internal fixation (ORIF). The purpose of this study was to determine the functional outcomes of radial head fractures treated with ORIF. Method. Fifty-two patients, with a mean age of 4412 years, who were treated with radial head ORIF were evaluated at a mean of 4.42.4 years. Thirty were isolated radial head fractures (Group A), 13 (Group B) were associated with a complex fracture-dislocation (terrible triad variants), and 5 (Group C) were associated with a proximal ulnar fracture (Monteggia/trans-olecranon variants). Fourty-four were partial articular fractures and 8 were complete articular fractures. Outcomes were assessed with physical and radiographic examination, and validated self-reported questionnaires. Results. The average PREE score (Patient Rated Elbow Evaluation) for Groups A, B, and C were 7.613.1, 12.313.4, and 108.5, respectively. The average MEPI (Mayo Elbow Performance Score) for Groups A, B, and C were 8913, 8511, and 918, respectively. For Groups A, B, and C respectively, the prevalence of radiographic radiocapitellar arthritis was 30%, 46%, and 20%. The average flexion/extension arc for Groups A, B, and C were 7 to 132, 6 to 134, and 10 to 132 respectively. Secondary surgery was performed in 17% of cases, most commonly for decreased motion. Three comminuted fractures failed ORIF and required conversion to radial head arthroplasty. Conclusion. Patients with radial head fractures, including those associated with complex fracture-dislocations, can achieve excellent functional outcomes with low self reported pain and disability when treated with ORIF, despite radiographic evidence of mild post-traumatic arthritis


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 18 - 18
1 May 2018
Williamson M Iliopoulos E Jain A Ebied W Trompeter A
Full Access

Background. There exists no consensus opinion as to the most suitable post-operative rehabilitation and weight bearing status for proximal tibia articular fractures treated with internal fixation using plates and screws. Objectives. The aim of this study is to investigate whether the post-operative weight bearing status is associated with loss of reduction and articular collapse. Study Design and Methods. Data was retrospectively analysed from our prospective database in a major trauma centre. Group I were non-weight bearing for the first six weeks post-operation and Group II were instructed to weight bear fully immediately post-operation. Radiographs were taken day one post-operation, at six weeks and at three months and analysed for fracture displacement and joint depression or loss of fixation. Results. 90 patients were included in the study. The follow up radiographs demonstrated no failure of fixation in either study group. One patient from the weight bearing group had >1mm joint depression (4mm) identified at the first follow up, which did not worsen by the second. Conclusions. This study shows immediate post-operative full weight bearing does not affect the fixation or cause articular collapse up to three months after surgery. We propose that patients should be encouraged to weight bear immediately post-operation


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 526 - 526
1 Nov 2011
Saddiki R Harisboure A Hemery X Ohl X Kabbaj R Dehoux É
Full Access

Purpose of the study: Within the framework of a regional study, we compared the efficacy of pinning using the PY technique and the Kapandji method for the treatment of fractures of the distal radius with posterior displacement. Material and methods: This was a prospective study designed as a phase III randomised therapeutic trial in parallel groups. An open monocentric study with multiple operators compared the PY and Kapandji techniques. Two comparable groups were established: the PY group and the Kapandji group (K) for which we measured: quality of reduction using the radiographic frontal and sagittal radial inclination (FRI and SRI), radial length and inferior radioulnar index. Objective and subjective functional outcome assessed range of motion and the DASH and Jakim scores. The quality of the intra-articular reduction of articular fractures was assessed arthroscopically at the time of implant removal during the sixth week. Results: The series included 97 patients followed for one year. The preoperative FRI was 15.17 with mean posterior shift of −19.2. At one year, the RI was 25.5 in the PY group versus 22.6 in the K group (p=0.009) and the SRI 10.5 in the PY group versus 3.7 in the K group (p=0.04). For fractures with a posteromedian fragment and Gerard-Marchand fractures, the DASH at one year was 2 in the PY group versus 32 in the K group. The Jakim score was 71 in the PY group versus 58 in the K group (p=0.03) for posteromedian fragment fractures. The arthroscopic control at six weeks of articular fractures did not reveal any significant difference in intra-articular reduction. There were no tendon tears in this series. Discussion: This series shows the quality of pin fixation for wrist fractures, comparable with plating. It emphasizes the importance of adapting the type of pinning to the fracture type and the patient. Conclusion: Treatment of fractures of the distal radius with posterior displacement with pin fixation remains a treatment of choice, reserving PY osteosynthesis for fractures with a posteromedian fragment and Gerard-Marchand fractures and Kapandji osteosynthsis for simple Colles fractures


Bone & Joint 360
Vol. 12, Issue 6 | Pages 6 - 12
1 Dec 2023
Vallier HA Breslin MA Taylor LA Hendrickson SB Ollivere B