Despite considerable legacy issues, Girdlestone's Resection Arthroplasty (GRA) remains a valuable tool in the armoury of the
Abstract. Objectives. Obesity is prevalent with nearly one third of the world's population being classified as obese. Total knee arthroplasty (TKA) is an effective treatment option for high BMI patients achieving similar outcomes to non-obese patients. However, increased rates of aseptic loosening in patients with a high BMI have been reported. In patients with high BMI/body mass there is an increase in strain placed on the implant fixation interfaces. As such component fixation is a potential concern when performing TKA in the obese patient. To address this concern the use of extended tibial stems in cemented implants or cementless fixation have been advocated. Extend tibial stems are thought to improve implant stability reducing the micromotion between interfaces and consequently the risk of aseptic loosening. Cementless implants, once biologic fixation is achieved, effectively integrate into bone eliminating an interface. This retrospective study compared the use of extended tibial stems and cementless implants to conventional cemented implants in high BMI patients. Methods. From a prospectively maintained database of 3239 primary Attune TKA (Depuy, Warsaw, Indiana), obese patients (body mass index (BMI) >30 kg/m²) were retrospectively reviewed. Two groups of patients 1) using a tibial stem extension [n=162] and 2) cementless fixation [n=163] were compared to 3) a control group (n=1426) with a standard tibial stem cemented implant. All operations were performed by or under the direct supervision of specialist
Total knee arthroplasty (TKA) is a common orthopaedic procedure with over 1,500 done in 2016 in Ireland alone. 96% of all TKAs are due to pain in the knee associated with osteoarthritis. According to the UK National Joint Registry (NJR), there is a 0.47%, 1.81%, 2.63% and 4.34% probability risk of undergoing a revision TKA within one, three, five and ten years respectively post-index surgery. A variety of reasons for failure of TKA have been described in the literature including infection, aseptic loosening, pain, instability, implant wear, mal-alignment, osteolysis, dislocation, peri-prosthetic fracture and implant fracture. The NexGen Posterior Stabilised Fixed has NJR revision rates of 0.44%, 1.61% and 2.54% at years one, three and five respectively. A retrospective review was carried out of 350 NexGen TKAs that were performed directly by, or under the supervision of, a fellowship trained
The use of a tourniquet during total knee arthroplasty (TKA) is controversial. Return to function and pain are believed to be affected by the use of a tourniquet. The hypothesis of this study was that use of a tourniquet (T) would delay postoperative functional recovery and increase pain as compared to no tourniquet use (NT). 200 patients were recruited for this prospective, double-blinded, randomized controlled trial. All surgeries were performed by one of two fellowship trained
Successful treatment of periprosthetic joint infection involves surgical intervention and identification of infecting organisms to enable targeted antibiotic therapy. Current guidelines recommend intra-operative culture sampling to include at least 4 tissue samples and for each sample to be taken with a separate instrument. We aimed to review current revision arthroplasty practice for Greater Glasgow, specifically comparing intra-operative sampling technique for infected revision cases with these guidelines. We reviewed the clinical notes of all patients undergoing lower limb revision arthroplasty procedures in Greater Glasgow Hospitals (WIG, GRI, SGH) from July 2013 to August 2014. Demographics of all cases were collected. For revision procedures performed for infection we recorded details of intraoperative samples taken (number, type and sampling technique) and time for samples to reach the laboratory. Results of microbiology cultures were reviewed. Two hundred and fifty five revision arthroplasty procedures (152 hips, 103 knees) were performed in the 12 month study period. Of these 57 (22%) were infected cases (28 hips, 29 knees). These cases were treated by 14
Summary. There is little knowledge in surgeons about the guidelines for prophylactic antibiotics in patients with prosthetic joints when undergoing a dental procedure. This study confirms this and there is need for robust and universal guidelines given the disastrous nature of prosthetic infection. Introduction. Infection as an indication for revision has increased to 12 % of the total revisions (NJR 9. th. report). However, it is next to impossible to find out the cause for a delayed prosthetic infection. With increasing number of arthroplasty procedures, is there a need for prophylactic antibiotics in patients with prostheses?. Methods. At London Knee Meeting 2012, a total of 163 surgeons were asked to take part in a survey. This was to find out if they knew of any existing guidelines for prophylaxis for dental procedures, if there was a need to practice more uniformly, and if they recommend such prophylaxis to their patients routinely. The grade of the surgeon and their experience in years was also noted. Results. Among the 163 surgeons who participated, 102 (62.6%) were
Summary Statement. A prospective randomised evaluation of primary TKA utilizing patient specific instruments demonstrated great accuracy of bone resection, improved sagittal alignment and the potential to improve functional outcomes and reduce operating room costs when compared to standard TKA instrumentation. Introduction. Patient specific instruments (PSI), an alternative to standard total knee arthroplasty (TKA) technology, have been proposed to improve the accuracy of TKA implant placement and post-operative limb alignment. Previous studies have shown mixed results regarding the effectiveness of PSI. The purposes of this study were (1) to evaluate the accuracy of the pre-operative predicted PSI plan compared to intra-operative TKA resection measurements, (2) to compare patient-reported outcome measures of PSI and standard TKA patients, and (3) to compare the incremental cost savings with PSI. Patients and Methods. This randomised, prospective pilot study of 19 patients undergoing primary TKA with a cruciate-retaining cemented prosthesis (NexGen, Zimmer Inc.) was conducted by a single high-volume
The renewed interest in the clinically proven low wear of the metal-on-metal bearing combined with the capacity of inserting a thin walled cementless acetabular component has fostered the reintroduction of hip resurfacing. As in other forms of conservative hip surgery, i.e. pelvic osteotomies and impingement surgery, patient selection will help minimize complications and the need for early reoperation. Patient Selection and Hip Resurfacing. Although hip resurfacing was initially plagued with high failure rates, the introduction of metal on metal bearings as well as hybrid fixation has shown excellent survivorships of 97 to 99% at 4 to 5 years follow-up. However, it is important to critically look at the initial published results. In all of these series there was some form of patient selection. For example, in the Daniel and associates publications, only patients with osteoarthritis with an age less than 55 were included with 79% of patients being male. Treacy and associates stated that: “the operation was offered to men under the age of 65 years and women under the age of 60 years, with normal bone stock judged by plain radiographs and an expectation that they would return to an active lifestyle, including some sports”. However in the materials and methods, although the mean age is 52 years, the range is from 17 to 76 years including some patients with rheumatoid arthritis as well as osteonecrosis. Obviously, some form of patient selection is needed; but how one integrates them is where the Surface Arthroplasty Risk Index (SARI) is useful. With a maximum score of 6, points are assigned accordingly: femoral head cyst >1cm: 2 points; patient weight <82kg: 2 points; previous hip surgery: 1 point; UCLA Activity level >6: 1 point. A SARI score >3 represented a 4 fold increase risk in early failure or adverse radiological changes and with a survivorship of 89% at four years. The SARI index also proved to be relevant in assessing the outcome of the all cemented McMinn resurfacing implant (Corin¯, Circentester, England) at a mean follow-up of 8.7 years. Hips which had failed or with evidence of radiographic failure on the femoral side had a significantly higher SARI score than the remaining hips, 3.9 versus 1.9. Finally, one must consider the underlying diagnosis when evaluating a patient for hip resurfacing. In cases of dysplasia, acetabular deficiencies combined with the inability of inserting screws through the acetabular component may make initial implant stability unpredictable. This deformity in combination with a significant leg length discrepancy or valgus femoral neck could compromise the functional results of surface arthroplasty, and in those situations a stem type total hip replacement may provide a superior functional outcome. In respect to other diagnoses (osteonecrosis, inflammatory arthritis), initial analyses have not demonstrated any particular diagnostic group at greater risk of earlier failure. The only reservation we have is in patients with compromised renal function since metal ions generated from the metal-on-metal bearing are excreted through the urine and the lack of clearance of these ions may lead to excessive levels in the blood. Surgical Technique. Because resurfacing has not been within the training curriculum of orthopaedic surgeons for the last 2 decades, there will most likely be a learning curve in the integration of this implant within clinical practice. This data was confirmed for hip resurfacing when looking at the Canadian Academic Experience where in the first 50 cases of five
Surgeons face a substantial risk of infection because of the occupational exposure to blood-borne pathogens (BBPs) from patients undergoing high-risk orthopaedic procedures. This study aimed to determine the seroprevalence of four BBPs among patients undergoing joint arthroplasty in Shanghai, China. In addition, we evaluated the significance of pre-operative screening by calculating a cost-to-benefit ratio. A retrospective observational study of pre-operative screening for BBPs, including hepatitis B and C viruses (HBV and HCV), human immunodeficiency virus (HIV) and Treponema pallidum (TP), was conducted for sequential patients in the orthopaedic department of a large urban teaching hospital between 01 January 2009 and 30 May 2016. Medical records were analysed to verify the seroprevalence of these BBPs among the patients stratified by age, gender, local origin, type of surgery, history of previous transfusion and marital status.Objectives
Methods
A cadaver study using six pairs of lower limbs was conducted to investigate the accuracy of computer navigation and standard instrumentation for the placement of the Birmingham Hip Resurfacing femoral component. The aim was to place all the femoral components with a stem-shaft angle of 135°. The mean stem-shaft angle obtained in the standard instrumentation group was 127.7° (120° to 132°), compared with 133.3° (131° to 139°) in the computer navigation group (p = 0.03). The scatter obtained with computer-assisted navigation was approximately half that found using the conventional jig. Computer navigation was more accurate and more consistent in its placement of the femoral component than standard instrumentation. We suggest that image-free computer-assisted navigation may have an application in aligning the femoral component during hip resurfacing.
Bone surface strains were measured in cadaver femora during loading prior to and after resurfacing of the hip and total hip replacement using an uncemented, tapered femoral component. In vitro loading simulated the single-leg stance phase during walking. Strains were measured on the medial and the lateral sides of the proximal aspect and the mid-diaphysis of the femur. Bone surface strains following femoral resurfacing were similar to those in the native femur, except for proximal shear strains, which were significantly less than those in the native femur. Proximomedial strains following total hip replacement were significantly less than those in the native and the resurfaced femur. These results are consistent with previous clinical evidence of bone loss after total hip replacement, and provide support for claims of bone preservation after resurfacing arthroplasty of the hip.