Advertisement for orthosearch.org.uk
Results 1 - 20 of 79
Results per page:
Bone & Joint Research
Vol. 12, Issue 5 | Pages 331 - 338
16 May 2023
Szymski D Walter N Krull P Melsheimer O Grimberg A Alt V Steinbrueck A Rupp M

Aims. The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, 9,110 (66.9%) HAs and 4,502 (33.1%) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared with uncemented fixated prosthesis (p = 0.013). In patients with THA no statistical difference between cemented and uncemented prosthesis was registered, however after one year 2.4% of infections were detected in uncemented and 2.1% in cemented THA. In the subpopulation of HA after one year, 1.9% of infections were registered in cemented and 2.8% in uncemented HA. BMI (p = 0.001) and Elixhauser Comorbidity Index (p < 0.003) were identified as risk factors of periprosthetic joint infection (PJI), while in THA cemented prosthesis also demonstrated an increased risk within the first 30 days (hazard ratio (HR) = 2.73; p = 0.010). Conclusion. The rate of infection after intracapsular femoral neck fracture was statistically significantly reduced in patients treated by antibiotic-loaded cemented HA. Particularly for patients with multiple risk factors for the development of a PJI, the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection. Cite this article: Bone Joint Res 2023;12(5):331–338


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 997 - 1002
1 Aug 2020
Leong JW Cook MJ O’Neill TW Board TN

Aims. The aim of this study was to investigate whether the use of antibiotic-loaded bone cement influenced the risk of revision surgery after primary total hip arthroplasty (THA) for osteoarthritis. Methods. The study involved data collected by the National Joint Registry (NJR) for England and Wales, Northern Ireland and the Isle of Man between 1 September 2005 and 31 August 2017. Cox proportional hazards were used to investigate the association between use of antibiotic-loaded bone cement and the risk of revision due to prosthetic joint infection (PJI), with adjustments made for the year of the initial procedure, age at the time of surgery, sex, American Society of Anesthesiologists (ASA) grade, head size, and body mass index (BMI). We looked also at the association between use of antibiotic-loaded bone cement and the risk of revision due to aseptic loosening or osteolysis. Results. The cohort included 418,857 THAs of whom 397,896 had received antibiotic-loaded bone cement and 20,961 plain cement. After adjusting for putative confounding factors, the risk of revision for PJI was lower in those in whom antibiotic-loaded bone cement was used (hazard ration (HR) 0.79; 95% confidence interval (CI) 0.64 to 0.98). There was also a protective effect on the risk of revision due to aseptic loosening or osteolysis, in the period of > 4.1 years after primary THA, HR 0.57, 95% CI 0.45, 0.72. Conclusion. Within the limits of registry analysis, this study showed an association between the use of antibiotic-loaded bone cement and lower rates of revision due to PJI. The findings support the continued use of antibiotic-loaded bone cement in cemented THA. Cite this article: Bone Joint J 2020;102-B(8):997–1002


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 7 - 15
1 Jan 2021
Farhan-Alanie MM Burnand HG Whitehouse MR

Aims. This study aimed to compare the effect of antibiotic-loaded bone cement (ALBC) versus plain bone cement (PBC) on revision rates for periprosthetic joint infection (PJI) and all-cause revisions following primary elective total hip arthroplasty (THA) and total knee arthroplasty (TKA). Methods. MEDLINE, Embase, Web of Science, and Cochrane databases were systematically searched for studies comparing ALBC versus PBC, reporting on revision rates for PJI or all-cause revision following primary elective THA or TKA. A random-effects meta-analysis was performed. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO ID CRD42018107691). Results. Nine studies and one registry report were identified, enabling the inclusion of 371,977 THA and 671,246 TKA. Pooled analysis for THA demonstrated ALBC was protective against revision for PJI compared with PBC (relative risk (RR) 0.66, 95% confidence interval (CI) 0.56 to 0.77; p < 0.001), however, no differences were seen for all-cause revision rate (RR 0.62, 95% CI 0.35 to 1.09; p = 0.100). For TKA, there were no significant differences in revision rates for PJI or all causes between ALBC and PBC (RR 0.92, 95% CI 0.59 to 1.45; p = 0.730, and RR 0.73, 95% CI 0.53 to 1.02; p = 0.060, respectively). Conclusion. ALBC demonstrated a protective effect against revision for PJI compared with PBC in THA with no difference in all-cause revisions. No differences in revision rates for PJI and all-cause revision between ALBC and PBC for TKA were observed. Cite this article: Bone Joint J 2021;103-B(1):7–15


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 21 - 21
1 Jun 2018
Gehrke T
Full Access

Total joint arthroplasty (TJA) is one of the most successful procedures in orthopaedics. Despite the excellent clinical and functional results, periprosthetic joint infection (PJI) following TJA is a feared complication. For instance, the reported PJI rate after primary total knee arthroplasty is about 0.5–1.9%. In general, prevention of periprosthetic joint and surgical site infections is of utmost importance. This can be reduced by strict antisepsis, adequate sterilization of the surgical instruments and meticulous surgical technique. An indisputable role in prevention of SSI in TJA has been the use of peri-operative systemic antibiotic prophylaxis. The most common recommended antibiotics for prophylaxis in TJA are cefazolin or cefuroxime. In contrast, routine use of commercial antibiotic-loaded bone cement (ALBC) in primary total joint arthroplasty is still a concern of open debate. The use of antibiotic-loaded bone cement delivers a high concentration of antibiotics locally and can decrease the infection rate, which is supported by several studies in the literature. In this context, we present the pros of routine use of commercial antibiotic-loaded bone cement


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 22 - 22
1 Jun 2018
Mont M
Full Access

Despite the demonstrated success in revision total joint arthroplasties, the utilization of antibiotic-loaded bone cement in primary total joint arthroplasty remains controversial. Multiple studies have demonstrated several risks associated with the routine use of this technique including: allergic reactions, changing the mechanical properties of the cement, emergence of resistant bacterial strains, systemic toxicity, and the added cost. In addition, evidence shows a currently low rate of periprosthetic joint infections in primary total joint arthroplasty (around 1%) and the theoretical benefit of marginally reducing this rate by using antibiotic-cement may not necessarily justify the associated risks and the added cost. Moreover, most of the primary total hip and an increasing number of primary total knee arthroplasties are cementless, which further raises questions about the routine use of antibiotic-loaded bone cement in primary total joint arthroplasty


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1331 - 1347
1 Nov 2019
Jameson SS Asaad A Diament M Kasim A Bigirumurame T Baker P Mason J Partington P Reed M

Aims. Antibiotic-loaded bone cements (ALBCs) may offer early protection against the formation of bacterial biofilm after joint arthroplasty. Use in hip arthroplasty is widely accepted, but there is a lack of evidence in total knee arthroplasty (TKA). The objective of this study was to evaluate the use of ALBC in a large population of TKA patients. Materials and Methods. Data from the National Joint Registry (NJR) of England and Wales were obtained for all primary cemented TKAs between March 2003 and July 2016. Patient, implant, and surgical variables were analyzed. Cox proportional hazards models were used to assess the influence of ALBC on risk of revision. Body mass index (BMI) data were available in a subset of patients. Results. Of 731 214 TKAs, 15 295 (2.1%) were implanted with plain cement and 715 919 (97.9%) with ALBC. There were 13 391 revisions; 2391 were performed for infection. After adjusting for other variables, ALBC had a significantly lower risk of revision for any cause (hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.77 to 0.93; p < 0.001). ALBC was associated with a lower risk of revision for all aseptic causes (HR 0.85, 95% CI 0.77 to 0.95; p < 0.001) and revisions for infection (HR 0.84, 95% CI 0.67 to 1.01; p = 0.06). The results were similar when BMI was added into the model, and in a subanalysis where surgeons using only ALBC over the entire study period were excluded. Prosthesis survival at ten years for TKAs implanted with ALBC was 96.3% (95% CI 96.3 to 96.4) compared with 95.5% (95% CI 95.0 to 95.9) in those implanted with plain cement. On a population level, where 100 000 TKAs are performed annually, this difference represents 870 fewer revisions at ten years in the ALBC group. Conclusion. After adjusting for a range of variables, ALBC was associated with a significantly lower risk of revision in this registry-based study of an entire nation of primary cemented knee arthroplasties. Using ALBC does not appear to increase midterm implant failure rates. Cite this article: Bone Joint J 2019;101-B:1331–1347


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 144 - 144
1 May 2016
Galasso O Balato G Catania M Gasparini G Mariconda M
Full Access

Introduction. The use of antibiotic-loaded polymethylmethacrylate bone-cement spacers during two-stage exchange procedures is the standard in the treatment of patients with delayed prosthetic joint infection. The real antimicrobial activity of these spacers is unclear because the adherence of bacteria to cement might result in clinical recurrence of infection. The purpose of the study is to evaluate the in vitro formation of Pseudomonas Aeruginosa (PA) and Staphylococcus spp. biofilm on antibiotic-loaded bone cement. Materials and methods. Cement disks (diameter = 6 mm) impregnated with gentamicin and colistin were submerged in bacterial suspensions of Methicillin-resistant Staphylococcus Aureus(MRSA), Staphylococcus epidermidis (SE), and PA. Negative controls (specimen disks without antibiotic) were similarly prepared. Biofilm formation was visualized by confocal scanning laser microscopy (CSLM), after staining the discs with the live/dead BacLight viability stain containing SYTO 9 dye and propidium iodide. Images from five randomly selected areas were acquired for each disc. Sequential optical sections of 2 µm were collected in sequence along the z-axis over the complete thickness of the sample. The resulting stacks of images were analyzed, quantified and rendered into three-dimensional (3D). The biofilm thickness on antibiotic bone cement compared with the controls was automatically evaluated. Results. CSLM showed living bacteria and bacterial biofilm on the surface of all cement disks, either antibiotic-loaded or controls. Mean biofilm thickness on the controls was 29.6 µm for MRSA, 32.3 µm for SE, and 59.7 µm for PA. The 3D rendering showed decrease in the biofilm thickness for all bacterial strains on gentamicin- and colistin-impragnated cement disks as compared with the controls. The incorporation of gentamicin into cement resulted in a 54%, 74%, and 45% reduction in the bacterial biofilm thickness for MRSA, PA and SE, respectively. The use of colistin leaded to a 51 % reduction in the PA biofilm thickness. Conclusion. The bacterial viability and biofilm formation are reduced by adding antibiotics to bone cement but antibiotic-loaded bone cement does not completely inhibit the formation of an infectious biofilm in vitro


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 113 - 113
1 Mar 2009
Lilikakis A Sutcliffe M
Full Access

Introduction: There is extensive literature on the effect of vancomycin on the compression strength of plain cements, none however on antibiotic-loaded cements. The addition of vancomycin to antibiotic-loaded bone cement is common practice in revision joint replacement surgery for infection. The scope of this study was to record the effect of vancomycin addition on the compression strength of antibiotic-loaded bone cement and to compare the results with the international standard (ISO 5833–2) in order to evaluate safety in clinical use. Materials & Methods: The formulations used were Palamed G, containing 0.55g of gentamicin; and Copal, containing 1g of gentamicin and 1g of clindamicin. Vancomycin concentrations of 2.5%, 5% and 10% per powder weight were added. The ISO requirements for the testing procedures were followed. Samples of Palamed G with 5% vancomycin and non-standardised mixing procedures were also tested, as well as samples of both bone cements without vancomycin, as controls. Results: The mean compression strength of plain Palamed G was 91.08 MPa. With the addition of 2.5%, 5% and 10% vancomycin, the mean compression strengths were 79.82, 82.3 and 74.56 MPa respectively, a reduction of 12.36%, 9.64% and 18.13%. The mean strength of the Palamed G specimens with 5% vancomycin and non-standardised mixing was 72.88 MPa, a 19.9% reduction. The mean compression strength of the plain Copal was 86.27 MPa. With the addition of 2.5%, 5% and 10% vancomycin, the mean compression strengths were 76.59, 78.92 and 71.19 MPa respectively, a reduction of 11.22%, 8.52% and 17.48%. Copal with 10% and Palamed G with 5% vancomycin and non-standardised mixing, were the only cements with compression strengths not significantly exceeding the ISO standard of 70 MPa. Conclusion: The addition of up to 5% vancomycin per powder weight to the antibiotic-loaded Copal and 10% to Palamed G bone cements can be considered safe. Care should be given to the mixing procedure of the cement, as it significantly affects its compression strength


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 5 - 5
24 Nov 2023
Szymski D Walter N Krull P Melsheimer O Grimberg A Alt V Steinbrück A Rupp M
Full Access

Aim. The aim of this investigation was to compare risk of infection in both cemented and cementless hemiarthroplasty (HA) as well as total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD) In HA and THA following femoral neck fracture fixation method was divided into cemented and cementless protheses and paired according to age, sex, body mass index (BMI), and the Elixhauser score using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, with 9,110 (66.9 %) HAs and 4502 (33.1 %) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared to cementless fixated prosthesis (p=0.013). In patients with THA no statistical difference between cemented and cementless prothesis was registered, however after one year 2.4 % of infections were detected in cementless and 2.1 % in cemented THA. In the subpopulation of HA after one year 1.9 % of infections were registered in cemented and 2.8 % in cementless HA. BMI (p=0.001) and Elixhauser-Comorbidity-Score (p<0.003) were identified as risk factors of PJI, while in THA also cemented prosthesis demonstrated within the first 30 days an increased risk (HR=2.728; p=0.010). Conclusion. The rate of infection after intracapsular femoral neck fracture was significantly reduced in patients treated by antibiotic-loaded cemented hemiarthroplasty. In particular for patients with multiple risk factors for the development of a PJI the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 70 - 70
1 Jan 2016
Chang Y
Full Access

Objectives. This study is to compare the elution characteristics, antimicrobial activity, and mechanical properties of antibiotic-loaded bone cement (ALBC) loaded with powder antibiotic, powder antibiotic with inert filler (xylitol), or liquid antibiotic, particularly focusing on vancomycin and amphotericin B. Methods. Cement specimens loaded with 2 g of vancomycin or amphotericin B powder (powder group), 2 g of antibiotic powder, and 2 g of xylitol (xylitol group) or 12 ml of antibiotic solution containing 2 g of antibiotic (liquid group) were tested. Results. Vancomycin elution was enhanced by 234% in the liquid group and by 12% in the xylitol group compared with the powder group. Amphotericin B elution was enhanced by 265% in the liquid group and by 65% in the xylitol group compared with the powder group. Based on the disk-diffusion assay, the eluate samples of vancomycin–loaded ALBC of the liquid group exhibited a significantly larger inhibitory zone than samples of the powder or xylitol group. Regarding the amphotericin B–loaded ALBCs, only the eluate samples of the liquid group exhibited a clear inhibitory zone which was not observed in either xylitol nor powder groups. The ultimate compressive strength was significantly reduced in specimens containing liquid antibiotics. Conclusions. Adding vancomycin or amphotericin B antibiotic powder in distilled water before mixing with bone cement can significantly improve the antibiotic-release efficacy than that by loading ALBC with the same dose of antibiotic powder. This simple, and effective method for preparation of ALBCs can significantly improve the antibiotic-release efficacy of ALBCs


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 14 - 14
1 Dec 2015
Lee S Hu C Chang Y
Full Access

The objective of this study was to compare the elution characteristics, antimicrobial activity and mechanical properties of antibiotic-loaded bone cement (ALBC) loaded with powdered antibiotic, powdered antibiotic with inert filler (xylitol), or liquid antibiotic, particularly focusing on vancomycin and amphotericin B. Cement specimens loaded with 2 g of vancomycin or amphotericin B powder (powder group), 2 g of antibiotic powder and 2 g of xylitol (xylitol group) or 12 ml of antibiotic solution containing 2 g of antibiotic (liquid group) were tested. Vancomycin elution was enhanced by 234% in the liquid group and by 12% in the xylitol group compared with the powder group. Amphotericin B elution was enhanced by 265% in the liquid group and by 65% in the xylitol group compared with the powder group. Based on the disk-diffusion assay, the eluate samples of vancomycin-loaded ALBC of the liquid group exhibited a significantly larger inhibitory zone than samples of the powder or the xylitol group. Regarding the ALBCs loaded with amphotericin B, only the eluate samples of the liquid group exhibited a clear inhibitory zone, which was not observed in either the xylitol or the powder groups. The ultimate compressive strength was significantly reduced in specimens containing liquid antibiotics. Adding vancomycin or amphotericin B antibiotic powder in distilled water before mixing with bone cement can significantly improve the efficiency of antibiotic release than can loading ALBC with the same dose of antibiotic powder. This simple and effective method for preparation of ALBCs can significantly improve the efficiency of antibiotic release in ALBCs. We thank H.Y. Hsu for performing the bioassay


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 66 - 66
1 Dec 2019
Berberich C Sanz-Ruiz P
Full Access

Aim

There is an ongoing controversy whether the observed benefit of infection risk reduction by ALBC outweighs the risk of possible antimicrobial resistance development.

Methods

The scientific & clinical literature in PubMed, Medline and Embase has been systematically reviewed with the keywords “antibiotic resistance”, “antibiotic loaded bone cement”, “local antibiotics”, “bacterial colonization” and “joint infection”. In total 28 relevant publications were found with the majority of them reporting laboratory results. Only 7 papers focused on clinical septic situations & patient data


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 175 - 175
1 Mar 2009
Castelli C Ferrari R Munro J Pitto R
Full Access

The aim of this prospective study was to assess safety and effectiveness of Spacer-K, a pre-formed articulating spacer made of gentamicin-impregnated acrylic bone cement. used in two-stage exchange technique for the infected total knee arthroplasty.

32 consecutive patients infected total knee arthroplasty were operated on in two centres. Infection was caused by Coagulase neg. Staphylococcus (21), Staphylococcus aureus (4), and others (4). In 3 case microorganisms were not identified. The mean implantation time of the spacer was 11 weeks (range, 7 to 28 weeks). The rehabilitation program between stages consisted in early range of motion exercises and partial weight-bearing. In one patient removal of the spacer and insertion of a molded cement block with vancomycin was necessary because of insurgence of methicillin-resistant Staphylococcus aureus.

The mean follow-up of 32 knees after removal of the spacer and insertion of the new prosthesis was 40 months (range, 24 to 75 months. The mean Knee Society functional score during spacer management was rated 75 points (range, 41 to 91 points) and was rated 87 points (range, 77 to 97 points) at latest follow-up. Preoperative range of motion improved markedly after removal of the infected prosthesis and insertion of the spacer. Neither breakage nor clinically relevant surface wear were detected. No implant-related complications were observed. Bone stock remained unchanged during the whole management process.

The Spacer-K is safe and effective for the management of the infected total knee arthroplasty.


Background

Antibiotic loaded bone cement (ALBC) is commonly used in cemented total hip arthroplasty (THA) in an attempt to reduce the risk of prosthetic joint infection (PJI). However, its role versus plain cement remains controversial due to the potential risk of developing resistant organisms and potential excess costs incurred from its usage. We investigated the relationship of ALBC and plain cement in affecting outcome of revision surgery after primary THA.

Methodology

We conducted a retrospective study of data collected from National Joint Registry for England and Wales, Northern Ireland and the Isle of Man between 1st September 2005 until 31st August 2017. A logistic regression analysis model was used to investigate the association between ALBC versus plain cement and the odds ratio (OR) for revision, adjusting for age, ASA grade, bearing surfaces, head size and cup and stem fixation. Indications for revision recorded in NJR were considered in separate models.


Bone & Joint Open
Vol. 2, Issue 2 | Pages 72 - 78
1 Feb 2021
Agni NR Costa ML Achten J O’Connor H Png ME Peckham N Dutton SJ Wallis S Milca S Reed M

Aims. Patients receiving cemented hemiarthroplasties after hip fracture have a significant risk of deep surgical site infection (SSI). Standard UK practice to minimize the risk of SSI includes the use of antibiotic-loaded bone cement with no consensus regarding type, dose, or antibiotic content of the cement. This is the protocol for a randomized clinical trial to investigate the clinical and cost-effectiveness of high dose dual antibiotic-loaded cement in comparison to low dose single antibiotic-loaded cement in patients 60 years and over receiving a cemented hemiarthroplasty for an intracapsular hip fracture. Methods. The WHiTE 8 Copal Or Palacos Antibiotic Loaded bone cement trial (WHiTE 8 COPAL) is a multicentre, multi-surgeon, parallel, two-arm, randomized clinical trial. The pragmatic study will be embedded in the World Hip Trauma Evaluation (WHiTE) (ISRCTN 63982700). Participants, including those that lack capacity, will be allocated on a 1:1 basis stratified by recruitment centre to either a low dose single antibiotic-loaded bone cement or a high dose dual antibiotic-loaded bone cement. The primary analysis will compare the differences in deep SSI rate as defined by the Centers for Disease Control and Prevention within 90 days of surgery via medical record review and patient self-reported questionnaires. Secondary outcomes include UK Core Outcome Set for hip fractures, complications, rate of antibiotic prescription, resistance patterns of deep SSI, and resource use (more specifically, cost-effectiveness) up to four months post-randomization. A minimum of 4,920 patients will be recruited to obtain 90% power to detect an absolute difference of 1.5% in the rate of deep SSI at 90 days for the expected 3% deep SSI rate in the control group. Conclusion. The results of this trial will provide evidence regarding clinical and cost-effectiveness between low dose single and high dose dual antibiotic-loaded bone cement, which will inform policy and practice guidelines such as the National Institute for Health and Care Excellence guidance on management of hip fractures. Cite this article: Bone Jt Open 2021;2(2):72–78


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 522 - 529
1 Mar 2021
Nichol T Callaghan J Townsend R Stockley I Hatton PV Le Maitre C Smith TJ Akid R

Aims. The aim of this study was to develop a single-layer hybrid organic-inorganic sol-gel coating that is capable of a controlled antibiotic release for cementless hydroxyapatite (HA)-coated titanium orthopaedic prostheses. Methods. Coatings containing gentamicin at a concentration of 1.25% weight/volume (wt/vol), similar to that found in commercially available antibiotic-loaded bone cement, were prepared and tested in the laboratory for: kinetics of antibiotic release; activity against planktonic and biofilm bacterial cultures; biocompatibility with cultured mammalian cells; and physical bonding to the material (n = 3 in all tests). The sol-gel coatings and controls were then tested in vivo in a small animal healing model (four materials tested; n = 6 per material), and applied to the surface of commercially pure HA-coated titanium rods. Results. The coating released gentamicin at > 10 × minimum inhibitory concentration (MIC) for sensitive staphylococcal strains within one hour thereby potentially giving effective prophylaxis for arthroplasty surgery, and showed > 99% elution of the antibiotic within the coating after 48 hours. There was total eradication of both planktonic bacteria and established bacterial biofilms of a panel of clinically relevant staphylococci. Mesenchymal stem cells adhered to the coated surfaces and differentiated towards osteoblasts, depositing calcium and expressing the bone marker protein, osteopontin. In the in vivo small animal bone healing model, the antibiotic sol-gel coated titanium (Ti)/HA rod led to osseointegration equivalent to that of the conventional HA-coated surface. Conclusion. In this study we report a new sol-gel technology that can release gentamicin from a bioceramic-coated cementless arthroplasty material. In vitro, local gentamicin levels are in excess of what can be achieved by antibiotic-loaded bone cement. In vivo, bone healing in an animal model is not impaired. This, thus, represents a biomaterial modification that may have the potential to protect at-risk patients from implant-related deep infection. Cite this article: Bone Joint J 2021;103-B(3):522–529


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 158 - 162
1 Jun 2020
Griseti Q Jacquet C Sautet P Abdel MP Parratte S Ollivier M Argenson J

Aims. The aim of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement, and smooth titanium alloy to inhibit staphylococci in an in vitro environment, based on the evaluation of the zone of inhibition (ZOI). The hypothesis was that there would be no significant difference in the inhibition of methicillin-sensitive or methicillin-resistant Staphylococcus aureus (MSSA/MRSA) between the two groups. Methods. A total of 30 beads made of three different materials (tantalum/3D porous titanium and smooth titanium alloy) were bathed for one hour in a solution of 1 g vancomycin in 20 ml of sterile water for injection (bath concentration: 50 mg/mL). Ten 1 cm. 3. cylinders of antibiotic-loaded cement were also created by mixing standard surgical cement with 1 g of vancomycin in standardized sterile moulds. The cylinders were then placed on agar plates inoculated with MSSA and MRSA. The ZOIs were measured each day and the cylinders were transferred onto a new inoculated plate. Results. For MSSA and MRSA, no inhibitory effect was found in the control group, and antibiotic-loaded smooth titanium alloy beads showed a short inhibitory effect until day 2. For MSSA, both tantalum and 3D porous titanium beads showed significantly larger mean ZOIs than cement beads (all p < 0.01) each day until day 7 for tantalum and until day 3 for 3D porous titanium. After six days, antibiotic-loaded cement had significantly larger mean ZOIs than the 3D porous titanium (p = 0.027), but no significant difference was found with tantalum (p = 0.082). For MRSA, both tantalum and 3D porous titanium beads had significantly larger mean ZOIs than antibiotic-loaded cement each day until day 6 for tantalum (all p < 0.01) and until day 3 for 3D porous titanium (all p < 0.04). Antibiotic-loaded cement had significantly larger mean ZOIs than tantalum and 3D porous titanium from day 7 to 9 (all p < 0.042). Conclusion. These results show that porous metal implants can deliver local antibiotics over slightly varying time frames based on in vitro analysis. Cite this article: Bone Joint J 2020;102-B(6 Supple A):158–162


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 110 - 110
1 Jun 2018
Gehrke T
Full Access

Periprosthetic joint infection (PJI) is one of the most feared complications following total knee arthroplasty (TKA). Despite improved peri-operative antibiotic management and local antibiotic-loaded bone cement PJI is reported in about 0.5–1.9 % of primary knee replacement. In case of revision knee arthroplasty the infection rate even occurs at about 8–10 %. Depending on an acute or late PJI several surgical methods are used to treat the infection. However, suffering of a late PJI, the only surgical procedure remains the exchange of the TKA in combination with a radical debridement and removal of all foreign material. In order to achieve complete debridement of the joint, the soft tissue must be radically excised. Frequently, the debridement of the posterior capsule causes severe difficulties, therefore it might be necessary to resect the collateral ligaments to be able to reach the posterior parts of the capsule. But this necessitates the use of a higher level of constraint such as a rotating or total hinge and fully cemented long stemmed revision implants. Furthermore, due to the cemented stems, a sufficient amount of antibiotic-loaded cement may be delivered to the bone as topical therapy. Up to now, several studies have shown excellent functional long-term results for hinge knee prostheses after PJI and a very good infection control rate. Advantages of the hinge knee prosthesis in cases of PJI are the opportunity for a complete debridement especially while addressing the posterior capsule after resection of the collateral ligaments and for delivering antibiotic-loaded bone cement at the stems of the prosthesis for topic therapy. Disadvantages are the need for a higher level of constraint and a possible higher blood loss due to the radical debridement


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 83 - 83
1 Aug 2017
Gehrke T
Full Access

Despite the prophylactic use of antibiotics and hygienic strategies, surgical site infection following total joint arthroplasty (TJA) is still a severe and unsolved complication. Since antibiotic-loaded bone cement (ALBC) was introduced by Buchholz in the 1970s, the use of ALBC has been increasingly used for the prevention and treatment of periprosthetic infection (PPI). However, the routine use of ALBC during primary TJA remains controversial. Recent clinical studies have found that ALBC is effective in reducing the risk of PJI following primary TJA. Although ALBC having the advantage of reducing the risk of PJI, the main disadvantages are the possible development of toxicity, antibiotic resistance, allergic reaction, and possible reduction of the mechanical properties of bone cement. Nevertheless, a recent published article demonstrated, that the use of high dose dual-antibiotic impregnated cement reduce significantly the rate of surgical site infections compared to standard low dose single ALBC in the setting of a hip fracture treating with hemiarthroplasty. Furthermore, Sanz-Ruiz et al. presented that the use of ALBC in TJA has favorable cost-efficiency profile. In this context, reasons why surgeons should use antibiotic-loaded bone cement during primary TJA are demonstrated


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 848 - 851
1 Jul 2019
Sautet P Parratte S Mékidèche T Abdel MP Flécher X Argenson J Ollivier M

Aims. The aims of this study were to compare the mean duration of antibiotic release and the mean zone of inhibition between vancomycin-loaded porous tantalum cylinders and antibiotic-loaded bone cement at intervals, and to evaluate potential intrinsic antimicrobial properties of tantalum in an in vitro medium environment against methicillin-sensitive Staphylococcus aureus (MSSA). Materials and Methods. Ten porous tantalum cylinders and ten cylinders of cement were used. The tantalum cylinders were impregnated with vancomycin, which was also added during preparation of the cylinders of cement. The cylinders were then placed on agar plates inoculated with MSSA. The diameter of the inhibition zone was measured each day, and the cylinders were transferred to a new inoculated plate. Inhibition zones were measured with a Vernier caliper and using an automated computed evaluation, and the intra- and interobserver reproducibility were measured. The mean inhibition zones between the two groups were compared with Wilcoxon’s test. Results. MSSA was inhibited for 12 days by the tantalum cylinders and for nine days by the cement cylinders. At day one, the mean zone of inhibition was 28.6 mm for the tantalum and 19.8 mm for the cement group (p < 0.001). At day ten, the mean zone of inhibition was 3.8 mm for the tantalum and 0 mm for the cement group (p < 0.001). The porous tantalum cylinders soaked only with phosphate buffered solution showed no zone of inhibition. Conclusion. Compared with cement, tantalum could release antibiotics for longer. Further studies should assess the advantages of using antibiotic-loaded porous tantalum implants at revision arthroplasty. Cite this article: Bone Joint J 2019;101-B:848–851